The dynamic load spectrum is one of the most important basis of design and dynamic characteristics analysis of machines. But it is difficult to measure it on many occasions, especially for mining machines, due to thei...The dynamic load spectrum is one of the most important basis of design and dynamic characteristics analysis of machines. But it is difficult to measure it on many occasions, especially for mining machines, due to their bad working circumstances and high cost of measurements. For such situation, the load spectrum has to be obtained by indirect determination methods. A new method to identify the load spectrum, cepstrum analysis method, was presented in this paper. This method can be used to eliminate the filtering influence of transfer function to the response signals so that the load spectrum can be determined indirectly. The experimental and engineering actual examples indicates that this method has the advantages that the calculation is simple and the measurement is easy.展开更多
A method for the determination of iodine based upon compound H2HgI4, formed between I- and Hg1+ in nitric acid and extracted in methyl isobutyl ketone(MIBK), was developed via atomic fluorescence spectrometry(AFS...A method for the determination of iodine based upon compound H2HgI4, formed between I- and Hg1+ in nitric acid and extracted in methyl isobutyl ketone(MIBK), was developed via atomic fluorescence spectrometry(AFS). After the compound is reduced with potassium borohydrid(KBH4), the resultant mercury vapor was injected into the instrument and iodine was, therefore, indirectly determined. Experimental parameters such as the conditions of extraction reagents, aqueous phase acidity, elemental mercury diffusion temperature in a vial and other factors were investigated and optimized. Under the optimum experimental conditions, this method shows a detection limit of 0.038μg/L iodine and a linear relationship between 0.04-20 p.g/L. The method was applied to determining the iodine content in marine duck eggs, kelps, laver and Ganoderma lucidum spirulina, showing a relative standard deviation(RSD) of 2.15% and the recoveries in the range of 98.1%-102.5%.展开更多
A PCV-modified electrode was simply prepared by dip-coating a pyrolytic graphite electrode in a NaAc-HAc buffer solution of PCV. The peak currents of differential pulse voltammograms (DPV) decrease with the addition o...A PCV-modified electrode was simply prepared by dip-coating a pyrolytic graphite electrode in a NaAc-HAc buffer solution of PCV. The peak currents of differential pulse voltammograms (DPV) decrease with the addition of Al and the peak potentials remain the same. The decreasing of Delta i(p) is linear with Al concentration in the range of 1 x 10(-8) similar to 1 x 10(-7) mol/L. The detection limit is 5 x 10(-9) mol/L and the relative standard deviation for 4 x 10(-8) mol/L Al is 2.9% (n=8). No serious interference was found. The determination of Al in water samples is reported.展开更多
Reliable estimation of the ventilation rate(VR)in intensive livestock buildings is necessary for studying building environmental control strategies and predicting indoor air quality and air emissions.As direct air exc...Reliable estimation of the ventilation rate(VR)in intensive livestock buildings is necessary for studying building environmental control strategies and predicting indoor air quality and air emissions.As direct air exchange measurements are time-consuming and expensive,it is environmentally inefficient to measure livestock building VR continuously in practice.Hence,indirect VR estimation methods have been widely used in modelling environmental control and air emissions,and also to measure airflow in the field.The accuracy of indirect measurement methods needs to be evaluated by comparing with direct measurements.In this study,the direct and indirect methods of determining hourly and daily mean VRs were applied to a mechanically-ventilated dairy free stall barn monitored by the 24-month National Air Emissions Monitoring Study.The direct method was used to continuously monitor fan rotational speeds,and differential static pressures,coupled with periodic in-situ fan performance assessments,to calculate the VR.The indirect method consisted of estimating the VR using CO2 concentration measurements and the CO2 mass balance method.The average daily and hourly means(mean±SD)of directly measured barn ventilation rates for two years were(246±73)m3/s and(245±77)m3/s,respectively.The average daily and hourly means(mean±SD)of barn ventilation rates estimated by the CO2 mass balance method were(287±93.4)m3/s and(287±118)m3/s,respectively.Correlation analyses showed a strong correlation between the indirect CO2 mass balance method and direct measurement methods(r=0.93 for daily means and r=0.85 for hourly means).展开更多
By the use of CPB, Cd(Ⅲ) forms a highly sensitive complex with 5-Br-PADAP in aqueous solution, molar absorptivity εis 1. 21 ×105 1. mol-1. cm-1.Trace amount of sulphide can be determined from its effect on the...By the use of CPB, Cd(Ⅲ) forms a highly sensitive complex with 5-Br-PADAP in aqueous solution, molar absorptivity εis 1. 21 ×105 1. mol-1. cm-1.Trace amount of sulphide can be determined from its effect on the complex of Cd (Ⅲ)-5-Br-PADAP-CPB, sulphide in the range 0~3. 2 ×10-6mol dm-3 causes a decrease in absorption, that is a linear function of the concentration, For 13ng cm-3 sulphide, common metal ions such as Na+, K+, Ca2+, Mg2+, Al3+ and anions such as CO (24μg cm-3). S2O (22μg cm-3). PO (20μg cm-3) etc. do not interfere. A method for the indirect determination of sulphide in beer and in dustrial waste water with good selectivity and accuracy is described.展开更多
The indirect voltammetric determination of trace sulfate (2.0×10^(-6)~4.0×10^(-5) mol/L ) with the adsorptive complex wave of lead(Ⅱ)-tetrakis (4-trimethylammonium phenyl) porphyrin (PbTTMAPP) is reported....The indirect voltammetric determination of trace sulfate (2.0×10^(-6)~4.0×10^(-5) mol/L ) with the adsorptive complex wave of lead(Ⅱ)-tetrakis (4-trimethylammonium phenyl) porphyrin (PbTTMAPP) is reported.This method has been used for the analysis of natural waters with satisfactory results.展开更多
文摘The dynamic load spectrum is one of the most important basis of design and dynamic characteristics analysis of machines. But it is difficult to measure it on many occasions, especially for mining machines, due to their bad working circumstances and high cost of measurements. For such situation, the load spectrum has to be obtained by indirect determination methods. A new method to identify the load spectrum, cepstrum analysis method, was presented in this paper. This method can be used to eliminate the filtering influence of transfer function to the response signals so that the load spectrum can be determined indirectly. The experimental and engineering actual examples indicates that this method has the advantages that the calculation is simple and the measurement is easy.
文摘A method for the determination of iodine based upon compound H2HgI4, formed between I- and Hg1+ in nitric acid and extracted in methyl isobutyl ketone(MIBK), was developed via atomic fluorescence spectrometry(AFS). After the compound is reduced with potassium borohydrid(KBH4), the resultant mercury vapor was injected into the instrument and iodine was, therefore, indirectly determined. Experimental parameters such as the conditions of extraction reagents, aqueous phase acidity, elemental mercury diffusion temperature in a vial and other factors were investigated and optimized. Under the optimum experimental conditions, this method shows a detection limit of 0.038μg/L iodine and a linear relationship between 0.04-20 p.g/L. The method was applied to determining the iodine content in marine duck eggs, kelps, laver and Ganoderma lucidum spirulina, showing a relative standard deviation(RSD) of 2.15% and the recoveries in the range of 98.1%-102.5%.
文摘A PCV-modified electrode was simply prepared by dip-coating a pyrolytic graphite electrode in a NaAc-HAc buffer solution of PCV. The peak currents of differential pulse voltammograms (DPV) decrease with the addition of Al and the peak potentials remain the same. The decreasing of Delta i(p) is linear with Al concentration in the range of 1 x 10(-8) similar to 1 x 10(-7) mol/L. The detection limit is 5 x 10(-9) mol/L and the relative standard deviation for 4 x 10(-8) mol/L Al is 2.9% (n=8). No serious interference was found. The determination of Al in water samples is reported.
文摘Reliable estimation of the ventilation rate(VR)in intensive livestock buildings is necessary for studying building environmental control strategies and predicting indoor air quality and air emissions.As direct air exchange measurements are time-consuming and expensive,it is environmentally inefficient to measure livestock building VR continuously in practice.Hence,indirect VR estimation methods have been widely used in modelling environmental control and air emissions,and also to measure airflow in the field.The accuracy of indirect measurement methods needs to be evaluated by comparing with direct measurements.In this study,the direct and indirect methods of determining hourly and daily mean VRs were applied to a mechanically-ventilated dairy free stall barn monitored by the 24-month National Air Emissions Monitoring Study.The direct method was used to continuously monitor fan rotational speeds,and differential static pressures,coupled with periodic in-situ fan performance assessments,to calculate the VR.The indirect method consisted of estimating the VR using CO2 concentration measurements and the CO2 mass balance method.The average daily and hourly means(mean±SD)of directly measured barn ventilation rates for two years were(246±73)m3/s and(245±77)m3/s,respectively.The average daily and hourly means(mean±SD)of barn ventilation rates estimated by the CO2 mass balance method were(287±93.4)m3/s and(287±118)m3/s,respectively.Correlation analyses showed a strong correlation between the indirect CO2 mass balance method and direct measurement methods(r=0.93 for daily means and r=0.85 for hourly means).
文摘By the use of CPB, Cd(Ⅲ) forms a highly sensitive complex with 5-Br-PADAP in aqueous solution, molar absorptivity εis 1. 21 ×105 1. mol-1. cm-1.Trace amount of sulphide can be determined from its effect on the complex of Cd (Ⅲ)-5-Br-PADAP-CPB, sulphide in the range 0~3. 2 ×10-6mol dm-3 causes a decrease in absorption, that is a linear function of the concentration, For 13ng cm-3 sulphide, common metal ions such as Na+, K+, Ca2+, Mg2+, Al3+ and anions such as CO (24μg cm-3). S2O (22μg cm-3). PO (20μg cm-3) etc. do not interfere. A method for the indirect determination of sulphide in beer and in dustrial waste water with good selectivity and accuracy is described.
文摘The indirect voltammetric determination of trace sulfate (2.0×10^(-6)~4.0×10^(-5) mol/L ) with the adsorptive complex wave of lead(Ⅱ)-tetrakis (4-trimethylammonium phenyl) porphyrin (PbTTMAPP) is reported.This method has been used for the analysis of natural waters with satisfactory results.