Addressing the challenges of passive Radio Frequency Identification(RFID)indoor localization technology in Non-Line-of-Sight(NLoS)and multipath environments,this paper presents an innovative approach by introducing a ...Addressing the challenges of passive Radio Frequency Identification(RFID)indoor localization technology in Non-Line-of-Sight(NLoS)and multipath environments,this paper presents an innovative approach by introducing a combined technology integrating an improved Kalman Filter with Space Domain Phase Difference of Arrival(SD-PDOA)and Received Signal Strength Indicator(RSSI).This methodology utilizes the distinct channel characteristics in multipath and NLoS contexts to effectively filter out interference and accurately extract localization information,thereby facilitating high precision and stability in passive RFID localization.The efficacy of this approach is demonstrated through detailed simulations and empirical tests conducted on a custom-built experimental platform consisting of passive RFID tags and an R420 reader.The findings are significant:in NLoS conditions,the four-antenna localization system achieved a notable localization accuracy of 0.25 m at a distance of 5 m.In complex multipath environments,this system achieved a localization accuracy of approximately 0.5 m at a distance of 5 m.When compared to conventional passive localization methods,our proposed solution exhibits a substantial improvement in indoor localization accuracy under NLoS and multipath conditions.This research provides a robust and effective technical solution for high-precision passive indoor localization in the Internet of Things(IoT)system,marking a significant advancement in the field.展开更多
The path loss analysis model based on 5 rays in vacancy indoor environment is proposed. The relationship between multipath overlapping and the path loss is analyzed mathematically. Time-domain technique is introduced ...The path loss analysis model based on 5 rays in vacancy indoor environment is proposed. The relationship between multipath overlapping and the path loss is analyzed mathematically. Time-domain technique is introduced to compute reflection coefficient in a very short time interval. A 5 rays path loss calculation method, which is satisfactory accurate, is developed. 5 typical environments are involved to analyze and generalize the common path loss characteristics in vacancy indoor environment. The simulation result shows that the path loss can be characterized as 3 zones with different path loss exponent as distance between transmitter and receiver increasing.展开更多
With 1 185 pi eces of questionnaire, it is found that in China, people take fresh air, odor, e tc., as well as indoor air temperature, humidity, as the most important indoor a ir parameters. It is also found that ther...With 1 185 pi eces of questionnaire, it is found that in China, people take fresh air, odor, e tc., as well as indoor air temperature, humidity, as the most important indoor a ir parameters. It is also found that there is a significant sensitivity differen ce in indoor environment between southerners and northerners in China. People fr om different regions have different demands for their working and living environ ment. Therefore, as a good design of air conditioning system, it is strongly rec ommended that the different demands of people from different regions should be t aken into consideration.展开更多
Over 100 human thermal indices have been developed to predict the combined thermal impact on the body.In principle,these indices based on energy thermal budget equations should not only be the most complex but also be...Over 100 human thermal indices have been developed to predict the combined thermal impact on the body.In principle,these indices based on energy thermal budget equations should not only be the most complex but also be the most accurate.However,the simple indices based on algebraic or statistical models[e.g.,the wet-bulb globe temperature(WBGT)]continue to be the most popular.A new heat stress index,the enthalpy dry-bulb temperature(EnD)for indoor environments is developed and validated in this study.The EnD index is unique in that it uses the air specific enthalpy,not the wet-bulb temperature,to measure the latent heat transfer from the skin to the surrounding environment.Theoretically,the EnD index can be treated as the equivalent temperature based on the convective heat transfer coefficient h_(c).Comparison is made between the EnD index and the widely used WBGT index based on the experimental data taken from three independent studies available in the scientific literature.The results show that the EnD index can reduce the overestimation of the dry-bulb air temperature and thus reduce heat stress in most cases,especially for hot and humid environments.It can be concluded that the EnD index has the potential to replace the WBGT index as the standard heat stress index in the future.展开更多
To explore the thermal responses under the non-thermal equilibrium cold environmental conditions,a laboratory study was conducted in climate chamber.The local skin temperatures and thermal sensation of 20 subjects wer...To explore the thermal responses under the non-thermal equilibrium cold environmental conditions,a laboratory study was conducted in climate chamber.The local skin temperatures and thermal sensation of 20 subjects were recorded at 10 min intervals for 90 min under air temperatures of 7.4,9.1,11 and 15 °C.The results show that both local skin temperatures and mean skin temperature decrease not only with the drop of ambient air temperature but also with the exposure time.Local thermal sensation and overall the thermal sensation have the similar temperature-varying and time-varying characteristics.Predicted mean vote(PMV) model cannot correctly predict the thermal sensation under non-thermal equilibrium cold environment.The correlation between local thermal sensation and local skin temperatures shows that thermal sensation is closely related to skin temperature.Skin temperature is an effective indicator of thermal sensation.A linear relationship model between overall thermal sensation and mean skin temperature,considering both ambient temperature and exposure time,was established in the non-thermal equilibrium cold environment,which makes the evaluation of thermal sensation more objective.展开更多
Microcontroller <span><span><span style="font-family:;" "="">is </span></span></span><span><span><span style="font-family:;" "...Microcontroller <span><span><span style="font-family:;" "="">is </span></span></span><span><span><span style="font-family:;" "="">widely</span></span></span><span><span><span style="font-family:;" "=""> </span></span></span><span><span><span style="font-family:;" "="">used in the intelligent life of modern society. Intelligent development based</span></span></span><span><span><span style="font-family:;" "=""> </span></span></span><span><span><span style="font-family:;" "="">on Microcontroller to solve the actual needs of people</span></span></span><span><span><span style="font-family:;" "="">’</span></span></span><span><span><span style="font-family:;" "="">s life, work, study and</span></span></span><span><span><span style="font-family:;" "=""> </span></span></span><span><span><span style="font-family:;" "="">other fields is the core of Microcontroller application.</span></span></span><span><span><span style="font-family:;" "=""> </span></span></span><span><span><span style="font-family:;" "="">Therefore, it is a task for researchers to understand the structure and performance of microcontroller, develop software, and be familiar with the method and process of intelligent development based on microcontroller. And with that in mind</span></span></span><span><span><span style="font-family:;" "="">, t</span></span></span><span><span><span style="font-family:;" "="">his paper designs and produces a physical hardware system for indoor environment detection based on STM32 microcontroller. The system can detect the light intensity, temperature and humidity, and CO gas concentration in the indoor environment;and the data is integrated and processed by the STM32 microcontroller to display the current parameter values of each quantity in the indoor environment on a 3.5-inch resistive screen;at the same time, the PC can also log in to the OneNET cloud platform through the web page, and display the light intensity, temperature and humidity, and CO gas concentration values in the indoor environment in real time in the device created by OneNET for real-time viewing. The system can also display the light intensity, temperature and humidity, and CO gas concentration values in the indoor environment in real time. The hardware system has been tested and tested to achieve its function.</span></span></span>展开更多
For the rural housing in Yanbian region in winter,the indoor thermal environment is bad but the energy consumption is high.And in order to solve the problem,the life particularities of the local residents,such as the ...For the rural housing in Yanbian region in winter,the indoor thermal environment is bad but the energy consumption is high.And in order to solve the problem,the life particularities of the local residents,such as the inhabitation custom and the different living ways,were analyzed.The comfortable temperature felt by the local residents was surveyed and summarized according to different age's stage.The subjective comfortable temperature was calculated by using the thermal comfort formula set up by D.A.Mcintyre.The result shows that the comfortable temperature between the survey and the calculation is different.After analyzing the survey and the result calculations,the range of local indoor comfortable temperature was given,which provides a reference basis for calculating the thermal comfort and energy efficiency as well as designing green rural houses.展开更多
Material is the substance foundation and carrier of indoor environment, and it is the premise and guarantee to realize the excellent indoor environment. It contains physical and sensory properties. In recent years, th...Material is the substance foundation and carrier of indoor environment, and it is the premise and guarantee to realize the excellent indoor environment. It contains physical and sensory properties. In recent years, the material design in indoor environment tends to be more rational, it not only pursues the external performance of material, but also pays more attention to the health and emotional of residents on the basis of scientific and rational use of its properties. This paper based on some scientific methods of literature study, field survey and case study combs the new trends of material design and analyses specific performance and application of materials in development. It is expected that the research can enrich the theory of contemporary material design and provide valuable reference for future material and interior environment design.展开更多
In this study, the indoor environmental quality (IEQ) in air conditioned residential buildings in a dry desert climate is examined from the perspective of occupants via two aspects: thermal comfort and indoor air qual...In this study, the indoor environmental quality (IEQ) in air conditioned residential buildings in a dry desert climate is examined from the perspective of occupants via two aspects: thermal comfort and indoor air quality. The study presents statistical data about the domestic-occupant thermal comfort sensations together with data describing the indoor air quality in Kuwaiti residential buildings. With respect to the latter, the overall IEQ acceptance using two measurements namely: physical measurements and subjective information collected via questionnaires, was used to evaluate 111 occupants living in twenty five air-conditioned residential buildings in the state of Kuwait. The operative temperature based on Actual Mean Vote (AMV) and Predicted Mean Vote (PMV) was identified using linear regression analysis of responses on the ASHRAE seven-point thermal sensation scale and was found to be 25.2°C and 23.3°C, respectively, in the summer season. Indoor air quality (IAQ) with respect to carbon dioxide concentration level was compared with the acceptable limits of international standards, i.e. ASHRAE Standard 62.1 [1]. The proposed overall IEQ acceptance findings in residential buildings show CO2 concentration level between 909 and 1250 ppm. However, this may be considered a higher level of CO2 concentration, which may require increasing ventilation rate through window operation or mechanical ventilation.展开更多
For the well-known 3G mobile communications standard UMTS, four different service classes have been specified. Considering two turbo decoding algorithms, like SOVA and log-MAP, it would be desirable to use an efficien...For the well-known 3G mobile communications standard UMTS, four different service classes have been specified. Considering two turbo decoding algorithms, like SOVA and log-MAP, it would be desirable to use an efficient turbo decoder. In this paper this decoder is shown to adapt dynamically to different service scenarios, considering parameters like performance and complexity for indoor/low range outdoor operating en-vironment. The scenarios show that for streaming service class real-time class applications the proposed de-coding algorithm depends on data rate;for the majority of scenarios SOVA is proposed, whereas log-MAP is optimal for increased data rates and medium-sized frames. On the other hand, conversational service class real-time applications cannot be established. For the majority of non real-time applications (interactive and background service classes) either algorithm can be used, while log-MAP is proposed for medium data rates and frame lengths.展开更多
In this study, indoor quality and environmental comfort were investigated in secondaiy school buildings located in the State of Kuwait. Comfort variables such as temperature and relative humidity (thermal comfort), no...In this study, indoor quality and environmental comfort were investigated in secondaiy school buildings located in the State of Kuwait. Comfort variables such as temperature and relative humidity (thermal comfort), noise (acoustic comfort), illumination (visual comfort), as well as allocated classroom floor area per student (spatial comfort) were measured. Data was collected over a 7-month period on a spot basis during school hours in student-occupied classrooms at 46 selected schools. The measured data was then compared to international guidelines and standards related to indoor environment quality. The data for noise and allocated space were shown to be in the comfort ranges in all the schools. However, 11% of the schools are not adequately illuminated, 33% had temperatures not within the recommended limits, and 22% of the schools had humidity levels either higher or lower than the recommended levels. Also, 9% of the schools had low illummation readings. In addition, during the data monitoring, a survey was conducted by which the student occupants completed a questionnaire so that subjective and objective evaluations could be compared. The findings of the questionnaire displayed significant correlations between the measured data and some ailments and other corr^laints experienced by the students. Ultimately, the results found in this research will provide a baseHne for comparison with future indoor environment quality assessments in buildings. Furthermore, recommendations are suggested in order to improve the environmental quality problems encountered in some of the schools, which may be beneficial for policymakers, facilities managers, and design engineers.展开更多
The aim of this work was to analyze the effect of the magnetic field generated by the household appliances on the airborne microbial surrounding these equipment located on indoor environments with particular interest ...The aim of this work was to analyze the effect of the magnetic field generated by the household appliances on the airborne microbial surrounding these equipment located on indoor environments with particular interest in the environmental fungi.A simultaneous environmental study was carried out in locals of three different geographical places of Havana,Cuba,which have televisions,computers and an electric generator.The air samples were made by a sedimentation method using Malt Extract Agar.The concentration of total aerobic mesophilic as well as fungi and yeasts were determined in rainy and little rainy seasons by applying as factors:exposure time of dishes(5 to 60 min)and distance to the wall(0 and 1 m)at a height of 1 m above the floor.The predominant fungal genera were Cladosporium,Penicillium and Aspergillus.In the dishes that were placed at 0 and 0.5 m from the emitting sources were observed that some bacteria colonies formed inhibition halos,a great diversity of filamentous fungi and an increase in the mycelium pigmentation as well as the pigments excretion.In the rainy season,the highest amounts of fungi were obtained in all samples.In the little rain season the count of the Gram-negative bacilli increased three times the Gram-positive cocci.展开更多
After the analysis of ecological significance and function of indoor plants decorations in the library,it considers that plants can help to reduce air pollution and purify reading environment and are beneficial to rea...After the analysis of ecological significance and function of indoor plants decorations in the library,it considers that plants can help to reduce air pollution and purify reading environment and are beneficial to reader's physical and psychological health.It emphasizes that plants decorations in the library should follow ecological,aesthetic,practical and economic principle.Then,the selection and arrangement of plant species have been analyzed for different positions in the library.展开更多
There are a large number of wooden-plank wall dwellings, a kind of traditional house with regional characteristics, existing in Chongqing area. We chose a typical house in Chongqing as the subject and measured it duri...There are a large number of wooden-plank wall dwellings, a kind of traditional house with regional characteristics, existing in Chongqing area. We chose a typical house in Chongqing as the subject and measured it during summer to research the situation of the indoor thermal comfort of wooden-plank wall dwellings. Based on the particularity of local residents' living habit and the characteristics of the local buildings, we analyzed the data of the field measurement and evaluated the thermal environment with APMV. The results show that the indoor thermal comfort of wooden-plank wall dwellings in summer is improved mainly by natural ventilation.展开更多
Objective:To discuss the effect of lesser-known potential risk factors,such as bedroom showers,on the prevalence of allergic rhinitis.Methods:A cross-sectional,population-based study was performed using both survey an...Objective:To discuss the effect of lesser-known potential risk factors,such as bedroom showers,on the prevalence of allergic rhinitis.Methods:A cross-sectional,population-based study was performed using both survey and fungal culturing in southern Taiwan.There were 998 participants enrolled in the survey,and 513 sets of fungal culture obtained.With score for allergic rhinitis(SFAR) more than 7,the patient was defined to have allergic rhinitis.Risks of allergic rhinitis were calculated as odds ratios for various predicted risk factors by logistic regression.Correlation between predicted risk factors and fungal level were examined with linear regression.Results:The adjusted odds ratio of frequently using bedroom shower to having allergic rhinitis was 1.572(95% confidence interval:1.090-2.265),and 0.962 for people with older age to have AR(95% confidence interval:0.949-0.976).As to the 24-hour fungal level,the standardized coefficient was 0.254 for frequent use of bedroom shower,and 0.106 for window open hours.Conclusions:Use of bedroom shower is a potential risk factor for allergic rhinitis development.展开更多
High concentrations of environmental fungi in the archives repositories are dangerous for the documents preserved in those places and for the workers'health.The aims of this work were to evaluate the behavior of t...High concentrations of environmental fungi in the archives repositories are dangerous for the documents preserved in those places and for the workers'health.The aims of this work were to evaluate the behavior of the fungal concentration and diversity in the indoor air of repositories of 3 archives located in Havana,Cuba,and to demonstrate the potential risk that these taxa represent for the documentary heritage preserved in these institutions.The indoor and outdoor environments were sampled with a biocollector.From the I/O ratios,it was evident that two of the studied archives were not contaminated,while one of them did show contamination despite having temperature and relative humidity values very similar to the other two.Aspergillus,Penicillium and Cladosporium were the predominant genera in the indoor environments.New finds for archival environments were the genera Harposporium and Scolecobasidium.The principal species classified ecologically as abundant were C.cladosporioides and P.citrinum.They are known as opportunistic pathogenic fungi.All the analyzed taxa excreted acids,the most of them degraded cellulose,starch and gelatin while about 48%excreted different pigments.But 33%of them showed the highest biodeteriogenic potential,evidencing that they are the most dangerous for the documentary collections.展开更多
Wireless sensor network(WSN)positioning has a good effect on indoor positioning,so it has received extensive attention in the field of positioning.Non-line-of sight(NLOS)is a primary challenge in indoor complex enviro...Wireless sensor network(WSN)positioning has a good effect on indoor positioning,so it has received extensive attention in the field of positioning.Non-line-of sight(NLOS)is a primary challenge in indoor complex environment.In this paper,a robust localization algorithm based on Gaussian mixture model and fitting polynomial is proposed to solve the problem of NLOS error.Firstly,fitting polynomials are used to predict the measured values.The residuals of predicted and measured values are clustered by Gaussian mixture model(GMM).The LOS probability and NLOS probability are calculated according to the clustering centers.The measured values are filtered by Kalman filter(KF),variable parameter unscented Kalman filter(VPUKF)and variable parameter particle filter(VPPF)in turn.The distance value processed by KF and VPUKF and the distance value processed by KF,VPUKF and VPPF are combined according to probability.Finally,the maximum likelihood method is used to calculate the position coordinate estimation.Through simulation comparison,the proposed algorithm has better positioning accuracy than several comparison algorithms in this paper.And it shows strong robustness in strong NLOS environment.展开更多
Currently,people pay more and more attention to the transitional resettlement of victims after various natural disasters.There is an urgent need for a large number of temporary houses to resettle the victims after nat...Currently,people pay more and more attention to the transitional resettlement of victims after various natural disasters.There is an urgent need for a large number of temporary houses to resettle the victims after natural disasters.Disaster-relief temporary houses(DTHs)played an important role in the post-disaster resettlement in the past,which can not only be produced on a large scale,but also can be quickly and conveniently erected,which were the main means to solve the problem of transitional resettlement.However,due to their temporary nature,there was no extra energy consuming system installed in the DTHs generally.Hence the indoor thermal environment inside the DTHs was severe in summer.In this study,combined with the field experimental tests of the DTHs in Wenchuan Earthquake and Lushan Earthquake and the experimental study of the full-size DTH,it found that the thermal environment inside the DTH was intolerably high in summer.It had negative impact on victims.In order to improve the thermal environment inside DTHs during post-disaster period which lacked of extra energy resources,this study used the method of combining phase change materials(PCMs)with walls of the DTH to explore its feasibility and effectiveness.The results showed that PCMs could effectively improve the thermal environment inside the DTH in summer.Furthermore,the difference of the composite positions between PCMs and the wall affected the improvement effect.The energy release rate of the PCMs assembly system(PAS)varied according to the positions of the PCMs.展开更多
基金supported in part by the Joint Project of National Natural Science Foundation of China(U22B2004,62371106)in part by China Mobile Research Institute&X-NET(Project Number:2022H002)+6 种基金in part by the Pre-Research Project(31513070501)in part by National Key R&D Program(2018AAA0103203)in part by Guangdong Provincial Research and Development Plan in Key Areas(2019B010141001)in part by Sichuan Provincial Science and Technology Planning Program of China(2022YFG0230,2023YFG0040)in part by the Fundamental Enhancement Program Technology Area Fund(2021-JCJQ-JJ-0667)in part by the Joint Fund of ZF and Ministry of Education(8091B022126)in part by Innovation Ability Construction Project for Sichuan Provincial Engineering Research Center of Communication Technology for Intelligent IoT(2303-510109-04-03-318020).
文摘Addressing the challenges of passive Radio Frequency Identification(RFID)indoor localization technology in Non-Line-of-Sight(NLoS)and multipath environments,this paper presents an innovative approach by introducing a combined technology integrating an improved Kalman Filter with Space Domain Phase Difference of Arrival(SD-PDOA)and Received Signal Strength Indicator(RSSI).This methodology utilizes the distinct channel characteristics in multipath and NLoS contexts to effectively filter out interference and accurately extract localization information,thereby facilitating high precision and stability in passive RFID localization.The efficacy of this approach is demonstrated through detailed simulations and empirical tests conducted on a custom-built experimental platform consisting of passive RFID tags and an R420 reader.The findings are significant:in NLoS conditions,the four-antenna localization system achieved a notable localization accuracy of 0.25 m at a distance of 5 m.In complex multipath environments,this system achieved a localization accuracy of approximately 0.5 m at a distance of 5 m.When compared to conventional passive localization methods,our proposed solution exhibits a substantial improvement in indoor localization accuracy under NLoS and multipath conditions.This research provides a robust and effective technical solution for high-precision passive indoor localization in the Internet of Things(IoT)system,marking a significant advancement in the field.
基金This project was supported by the key programof the Nationed Natural Science Foundation of China (60432040)
文摘The path loss analysis model based on 5 rays in vacancy indoor environment is proposed. The relationship between multipath overlapping and the path loss is analyzed mathematically. Time-domain technique is introduced to compute reflection coefficient in a very short time interval. A 5 rays path loss calculation method, which is satisfactory accurate, is developed. 5 typical environments are involved to analyze and generalize the common path loss characteristics in vacancy indoor environment. The simulation result shows that the path loss can be characterized as 3 zones with different path loss exponent as distance between transmitter and receiver increasing.
文摘With 1 185 pi eces of questionnaire, it is found that in China, people take fresh air, odor, e tc., as well as indoor air temperature, humidity, as the most important indoor a ir parameters. It is also found that there is a significant sensitivity differen ce in indoor environment between southerners and northerners in China. People fr om different regions have different demands for their working and living environ ment. Therefore, as a good design of air conditioning system, it is strongly rec ommended that the different demands of people from different regions should be t aken into consideration.
文摘Over 100 human thermal indices have been developed to predict the combined thermal impact on the body.In principle,these indices based on energy thermal budget equations should not only be the most complex but also be the most accurate.However,the simple indices based on algebraic or statistical models[e.g.,the wet-bulb globe temperature(WBGT)]continue to be the most popular.A new heat stress index,the enthalpy dry-bulb temperature(EnD)for indoor environments is developed and validated in this study.The EnD index is unique in that it uses the air specific enthalpy,not the wet-bulb temperature,to measure the latent heat transfer from the skin to the surrounding environment.Theoretically,the EnD index can be treated as the equivalent temperature based on the convective heat transfer coefficient h_(c).Comparison is made between the EnD index and the widely used WBGT index based on the experimental data taken from three independent studies available in the scientific literature.The results show that the EnD index can reduce the overestimation of the dry-bulb air temperature and thus reduce heat stress in most cases,especially for hot and humid environments.It can be concluded that the EnD index has the potential to replace the WBGT index as the standard heat stress index in the future.
基金Project(50838009) supported by the National Natural Science Foundation of China
文摘To explore the thermal responses under the non-thermal equilibrium cold environmental conditions,a laboratory study was conducted in climate chamber.The local skin temperatures and thermal sensation of 20 subjects were recorded at 10 min intervals for 90 min under air temperatures of 7.4,9.1,11 and 15 °C.The results show that both local skin temperatures and mean skin temperature decrease not only with the drop of ambient air temperature but also with the exposure time.Local thermal sensation and overall the thermal sensation have the similar temperature-varying and time-varying characteristics.Predicted mean vote(PMV) model cannot correctly predict the thermal sensation under non-thermal equilibrium cold environment.The correlation between local thermal sensation and local skin temperatures shows that thermal sensation is closely related to skin temperature.Skin temperature is an effective indicator of thermal sensation.A linear relationship model between overall thermal sensation and mean skin temperature,considering both ambient temperature and exposure time,was established in the non-thermal equilibrium cold environment,which makes the evaluation of thermal sensation more objective.
文摘Microcontroller <span><span><span style="font-family:;" "="">is </span></span></span><span><span><span style="font-family:;" "="">widely</span></span></span><span><span><span style="font-family:;" "=""> </span></span></span><span><span><span style="font-family:;" "="">used in the intelligent life of modern society. Intelligent development based</span></span></span><span><span><span style="font-family:;" "=""> </span></span></span><span><span><span style="font-family:;" "="">on Microcontroller to solve the actual needs of people</span></span></span><span><span><span style="font-family:;" "="">’</span></span></span><span><span><span style="font-family:;" "="">s life, work, study and</span></span></span><span><span><span style="font-family:;" "=""> </span></span></span><span><span><span style="font-family:;" "="">other fields is the core of Microcontroller application.</span></span></span><span><span><span style="font-family:;" "=""> </span></span></span><span><span><span style="font-family:;" "="">Therefore, it is a task for researchers to understand the structure and performance of microcontroller, develop software, and be familiar with the method and process of intelligent development based on microcontroller. And with that in mind</span></span></span><span><span><span style="font-family:;" "="">, t</span></span></span><span><span><span style="font-family:;" "="">his paper designs and produces a physical hardware system for indoor environment detection based on STM32 microcontroller. The system can detect the light intensity, temperature and humidity, and CO gas concentration in the indoor environment;and the data is integrated and processed by the STM32 microcontroller to display the current parameter values of each quantity in the indoor environment on a 3.5-inch resistive screen;at the same time, the PC can also log in to the OneNET cloud platform through the web page, and display the light intensity, temperature and humidity, and CO gas concentration values in the indoor environment in real time in the device created by OneNET for real-time viewing. The system can also display the light intensity, temperature and humidity, and CO gas concentration values in the indoor environment in real time. The hardware system has been tested and tested to achieve its function.</span></span></span>
基金Supported by National Natural Science Foundation of China(50378023)
文摘For the rural housing in Yanbian region in winter,the indoor thermal environment is bad but the energy consumption is high.And in order to solve the problem,the life particularities of the local residents,such as the inhabitation custom and the different living ways,were analyzed.The comfortable temperature felt by the local residents was surveyed and summarized according to different age's stage.The subjective comfortable temperature was calculated by using the thermal comfort formula set up by D.A.Mcintyre.The result shows that the comfortable temperature between the survey and the calculation is different.After analyzing the survey and the result calculations,the range of local indoor comfortable temperature was given,which provides a reference basis for calculating the thermal comfort and energy efficiency as well as designing green rural houses.
基金Sponsored by the phased results of 2015 Hubei Education Department Social Sciences Key Programs(15D010)
文摘Material is the substance foundation and carrier of indoor environment, and it is the premise and guarantee to realize the excellent indoor environment. It contains physical and sensory properties. In recent years, the material design in indoor environment tends to be more rational, it not only pursues the external performance of material, but also pays more attention to the health and emotional of residents on the basis of scientific and rational use of its properties. This paper based on some scientific methods of literature study, field survey and case study combs the new trends of material design and analyses specific performance and application of materials in development. It is expected that the research can enrich the theory of contemporary material design and provide valuable reference for future material and interior environment design.
文摘In this study, the indoor environmental quality (IEQ) in air conditioned residential buildings in a dry desert climate is examined from the perspective of occupants via two aspects: thermal comfort and indoor air quality. The study presents statistical data about the domestic-occupant thermal comfort sensations together with data describing the indoor air quality in Kuwaiti residential buildings. With respect to the latter, the overall IEQ acceptance using two measurements namely: physical measurements and subjective information collected via questionnaires, was used to evaluate 111 occupants living in twenty five air-conditioned residential buildings in the state of Kuwait. The operative temperature based on Actual Mean Vote (AMV) and Predicted Mean Vote (PMV) was identified using linear regression analysis of responses on the ASHRAE seven-point thermal sensation scale and was found to be 25.2°C and 23.3°C, respectively, in the summer season. Indoor air quality (IAQ) with respect to carbon dioxide concentration level was compared with the acceptable limits of international standards, i.e. ASHRAE Standard 62.1 [1]. The proposed overall IEQ acceptance findings in residential buildings show CO2 concentration level between 909 and 1250 ppm. However, this may be considered a higher level of CO2 concentration, which may require increasing ventilation rate through window operation or mechanical ventilation.
文摘For the well-known 3G mobile communications standard UMTS, four different service classes have been specified. Considering two turbo decoding algorithms, like SOVA and log-MAP, it would be desirable to use an efficient turbo decoder. In this paper this decoder is shown to adapt dynamically to different service scenarios, considering parameters like performance and complexity for indoor/low range outdoor operating en-vironment. The scenarios show that for streaming service class real-time class applications the proposed de-coding algorithm depends on data rate;for the majority of scenarios SOVA is proposed, whereas log-MAP is optimal for increased data rates and medium-sized frames. On the other hand, conversational service class real-time applications cannot be established. For the majority of non real-time applications (interactive and background service classes) either algorithm can be used, while log-MAP is proposed for medium data rates and frame lengths.
文摘In this study, indoor quality and environmental comfort were investigated in secondaiy school buildings located in the State of Kuwait. Comfort variables such as temperature and relative humidity (thermal comfort), noise (acoustic comfort), illumination (visual comfort), as well as allocated classroom floor area per student (spatial comfort) were measured. Data was collected over a 7-month period on a spot basis during school hours in student-occupied classrooms at 46 selected schools. The measured data was then compared to international guidelines and standards related to indoor environment quality. The data for noise and allocated space were shown to be in the comfort ranges in all the schools. However, 11% of the schools are not adequately illuminated, 33% had temperatures not within the recommended limits, and 22% of the schools had humidity levels either higher or lower than the recommended levels. Also, 9% of the schools had low illummation readings. In addition, during the data monitoring, a survey was conducted by which the student occupants completed a questionnaire so that subjective and objective evaluations could be compared. The findings of the questionnaire displayed significant correlations between the measured data and some ailments and other corr^laints experienced by the students. Ultimately, the results found in this research will provide a baseHne for comparison with future indoor environment quality assessments in buildings. Furthermore, recommendations are suggested in order to improve the environmental quality problems encountered in some of the schools, which may be beneficial for policymakers, facilities managers, and design engineers.
基金the Ministry of Science,Technology and Environment,Cuba(PCA-2118025001)。
文摘The aim of this work was to analyze the effect of the magnetic field generated by the household appliances on the airborne microbial surrounding these equipment located on indoor environments with particular interest in the environmental fungi.A simultaneous environmental study was carried out in locals of three different geographical places of Havana,Cuba,which have televisions,computers and an electric generator.The air samples were made by a sedimentation method using Malt Extract Agar.The concentration of total aerobic mesophilic as well as fungi and yeasts were determined in rainy and little rainy seasons by applying as factors:exposure time of dishes(5 to 60 min)and distance to the wall(0 and 1 m)at a height of 1 m above the floor.The predominant fungal genera were Cladosporium,Penicillium and Aspergillus.In the dishes that were placed at 0 and 0.5 m from the emitting sources were observed that some bacteria colonies formed inhibition halos,a great diversity of filamentous fungi and an increase in the mycelium pigmentation as well as the pigments excretion.In the rainy season,the highest amounts of fungi were obtained in all samples.In the little rain season the count of the Gram-negative bacilli increased three times the Gram-positive cocci.
文摘After the analysis of ecological significance and function of indoor plants decorations in the library,it considers that plants can help to reduce air pollution and purify reading environment and are beneficial to reader's physical and psychological health.It emphasizes that plants decorations in the library should follow ecological,aesthetic,practical and economic principle.Then,the selection and arrangement of plant species have been analyzed for different positions in the library.
基金Funded by National Key Technology Research and Development Program of the Ministry of Science and Technology of China During the“12th Five Year Plan”(2013BAJ11B04)Funding Project for fundamental and Frontier Science of the Chongqing Science&Technology Commission(cstc2014jcyj A90024)
文摘There are a large number of wooden-plank wall dwellings, a kind of traditional house with regional characteristics, existing in Chongqing area. We chose a typical house in Chongqing as the subject and measured it during summer to research the situation of the indoor thermal comfort of wooden-plank wall dwellings. Based on the particularity of local residents' living habit and the characteristics of the local buildings, we analyzed the data of the field measurement and evaluated the thermal environment with APMV. The results show that the indoor thermal comfort of wooden-plank wall dwellings in summer is improved mainly by natural ventilation.
文摘Objective:To discuss the effect of lesser-known potential risk factors,such as bedroom showers,on the prevalence of allergic rhinitis.Methods:A cross-sectional,population-based study was performed using both survey and fungal culturing in southern Taiwan.There were 998 participants enrolled in the survey,and 513 sets of fungal culture obtained.With score for allergic rhinitis(SFAR) more than 7,the patient was defined to have allergic rhinitis.Risks of allergic rhinitis were calculated as odds ratios for various predicted risk factors by logistic regression.Correlation between predicted risk factors and fungal level were examined with linear regression.Results:The adjusted odds ratio of frequently using bedroom shower to having allergic rhinitis was 1.572(95% confidence interval:1.090-2.265),and 0.962 for people with older age to have AR(95% confidence interval:0.949-0.976).As to the 24-hour fungal level,the standardized coefficient was 0.254 for frequent use of bedroom shower,and 0.106 for window open hours.Conclusions:Use of bedroom shower is a potential risk factor for allergic rhinitis development.
文摘High concentrations of environmental fungi in the archives repositories are dangerous for the documents preserved in those places and for the workers'health.The aims of this work were to evaluate the behavior of the fungal concentration and diversity in the indoor air of repositories of 3 archives located in Havana,Cuba,and to demonstrate the potential risk that these taxa represent for the documentary heritage preserved in these institutions.The indoor and outdoor environments were sampled with a biocollector.From the I/O ratios,it was evident that two of the studied archives were not contaminated,while one of them did show contamination despite having temperature and relative humidity values very similar to the other two.Aspergillus,Penicillium and Cladosporium were the predominant genera in the indoor environments.New finds for archival environments were the genera Harposporium and Scolecobasidium.The principal species classified ecologically as abundant were C.cladosporioides and P.citrinum.They are known as opportunistic pathogenic fungi.All the analyzed taxa excreted acids,the most of them degraded cellulose,starch and gelatin while about 48%excreted different pigments.But 33%of them showed the highest biodeteriogenic potential,evidencing that they are the most dangerous for the documentary collections.
基金supported by the National Natural Science Foundation of China under Grant No.62273083 and No.61973069Natural Science Foundation of Hebei Province under Grant No.F2020501012。
文摘Wireless sensor network(WSN)positioning has a good effect on indoor positioning,so it has received extensive attention in the field of positioning.Non-line-of sight(NLOS)is a primary challenge in indoor complex environment.In this paper,a robust localization algorithm based on Gaussian mixture model and fitting polynomial is proposed to solve the problem of NLOS error.Firstly,fitting polynomials are used to predict the measured values.The residuals of predicted and measured values are clustered by Gaussian mixture model(GMM).The LOS probability and NLOS probability are calculated according to the clustering centers.The measured values are filtered by Kalman filter(KF),variable parameter unscented Kalman filter(VPUKF)and variable parameter particle filter(VPPF)in turn.The distance value processed by KF and VPUKF and the distance value processed by KF,VPUKF and VPPF are combined according to probability.Finally,the maximum likelihood method is used to calculate the position coordinate estimation.Through simulation comparison,the proposed algorithm has better positioning accuracy than several comparison algorithms in this paper.And it shows strong robustness in strong NLOS environment.
文摘Currently,people pay more and more attention to the transitional resettlement of victims after various natural disasters.There is an urgent need for a large number of temporary houses to resettle the victims after natural disasters.Disaster-relief temporary houses(DTHs)played an important role in the post-disaster resettlement in the past,which can not only be produced on a large scale,but also can be quickly and conveniently erected,which were the main means to solve the problem of transitional resettlement.However,due to their temporary nature,there was no extra energy consuming system installed in the DTHs generally.Hence the indoor thermal environment inside the DTHs was severe in summer.In this study,combined with the field experimental tests of the DTHs in Wenchuan Earthquake and Lushan Earthquake and the experimental study of the full-size DTH,it found that the thermal environment inside the DTH was intolerably high in summer.It had negative impact on victims.In order to improve the thermal environment inside DTHs during post-disaster period which lacked of extra energy resources,this study used the method of combining phase change materials(PCMs)with walls of the DTH to explore its feasibility and effectiveness.The results showed that PCMs could effectively improve the thermal environment inside the DTH in summer.Furthermore,the difference of the composite positions between PCMs and the wall affected the improvement effect.The energy release rate of the PCMs assembly system(PAS)varied according to the positions of the PCMs.