期刊文献+
共找到158篇文章
< 1 2 8 >
每页显示 20 50 100
Conductivity effects during the transition from collisionless to collisional regimes in cylindrical inductively coupled plasmas 被引量:1
1
作者 Wei YANG Fei GAO Younian WANG 《Plasma Science and Technology》 SCIE EI CAS CSCD 2022年第5期118-133,共16页
A numerical model is developed to study the conductivity effects during the transition from collisionless to collisional regimes in cylindrical inductively coupled argon plasmas at pressures of 0.1-20 Pa.The model con... A numerical model is developed to study the conductivity effects during the transition from collisionless to collisional regimes in cylindrical inductively coupled argon plasmas at pressures of 0.1-20 Pa.The model consists of electron kinetics module,electromagnetics module,and global model module.It allows for self-consistent description of non-local electron kinetics and collisionless electron heating in terms of the conductivity of homogeneous hot plasma.Simulation results for non-local conductivity case are compared with predictions for the assumption of local conductivity case.Electron densities and effective electron temperatures under non-local and local conductivities show obvious differences at relatively low pressures.As increasing pressure,the results under the two cases of conductivities tend to converge,which indicates the transition from collisionless to collisional regimes.At relatively low pressures the local negative power absorption is predicted by non-local conductivity case but not captured by local conductivity case.The two-dimensional(2D)profiles of electron current density and electric field are coincident for local conductivity case in the pressure range of interest,but it roughly holds true for non-local conductivity case at very high pressure.In addition,an effective conductivity with consideration of non-collisional stochastic heating effect is introduced.The effective conductivity almost reproduces the electron density and effective electron temperature for the non-local conductivity case,but does not capture the non-local relation between electron current and electric field as well as the local negative power absorption that is observed for nonlocal conductivity case at low pressures. 展开更多
关键词 inductively coupled plasmas conductivity effects electron kinetics plasma parameters electromagnetic wave characteristics ELECTRODYNAMICS
下载PDF
Effect of Sample Matrix on Radial and Axial Profiles of Ion Abundance in Inductively Coupled Plasma Mass Spectrometry
2
作者 Clarisse Mariet Francine Carrot Mélanie Moskura 《American Journal of Analytical Chemistry》 2011年第7期739-751,共13页
In inductively coupled plasma mass spectrometry (ICP-MS) analysis, only a few options are available to deal with non-spectroscopic interferences. Considering that diluting the sample is impractical for traces analysis... In inductively coupled plasma mass spectrometry (ICP-MS) analysis, only a few options are available to deal with non-spectroscopic interferences. Considering that diluting the sample is impractical for traces analysis, other alternatives must be employed. Traditionally, the method of standard additions is used to correct the matrix effect but it is a time consuming method. Others methods involves separation techniques. Another way to overcome matrix interferences is to understand the mechanism involved and adjust plasma viewing conditions to reduce or eliminate the effect. In this study, the effect of various concomitant elements in ICP-MS was assessed by measuring the distribution of selected singly charged analyte ions (Al, V, Cr, Mn, Ni, Co, Cu, Zn, As, In, Ba, La, Ce, Pb), doubly charged ions (La, Ce, Ba and Pb) and oxides ions (BaO) in the presence of concomitant elements spanning a mass range from 23 (Na) to 133 (Cs) u.m.a. and different ionization energies. Concomitant elements are alkali metals, alkaline earth metals and Si. Analyte ion suppression was observed while moving the ICP across and away from the sampling interface with or without a single concomitant element. Matrix effect measures were realised, firstly, to highlight the relation between the signal extinction of an analyte and the masse of the concomitant element, and secondly to highlight the relation between the removal of the analyte signal and the first ionization energy of the element of matrix. A dependence upon both the mass of the matrix element and the mass of the analyte was observed. The suppression seems increased with increasing matrix element mass and decreased with increasing analyte mass. The effect of the mass of the matrix element was the more significant of the two factors. If space-charge effects were found to be significant for matrix elements of much lower mass, it seems diffusion also played an active part for heavier matrix elements. Finally, some evidence was found for a shift in ion-atom equilibrium for dications and for energy demand regarding oxides. 展开更多
关键词 MATRIX effects Easily Ionized Elements inductively coupled plasma Mass SPECTROMETRY Spatial PROFILING
下载PDF
<i>In Situ</i>Analysis of Copper Alloys by Femtosecond Laser Ablation Inductively Coupled Plasma Mass Spectrometry: Constrains on Matrix Effects
3
作者 Germán Velásquez Anastassia Y. Borisova +1 位作者 Sandrine Baron Luc Robbiola 《American Journal of Analytical Chemistry》 2018年第3期150-161,共12页
Direct analysis of copper-base alloys using laser ablation techniques is an increasingly common procedure in cultural heritage studies. However, main discussions remain focused on the possibility of using non-matrix m... Direct analysis of copper-base alloys using laser ablation techniques is an increasingly common procedure in cultural heritage studies. However, main discussions remain focused on the possibility of using non-matrix matched external reference materials. To evaluate the occurrence of matrix effects during in situ microanalysis of copper-base materials, using near infrared femtosecond laser ablation techniques (NIR fs-LA-ICP-MS), two bronzes, i.e., (Sn-Zn)-ternary and (Sn)-binary copper-matrix reference materials, as well as a reference synthetic glass (NIST-SRM-610) have been analyzed. The results have been compared to data obtained on a sulfide-matrix reference material. Similar values in relative sensitivity averages of 63Cu, 118Sn and 66Zn, as well as in 118Sn/63Cu and 66Zn/63Cu ratios were obtained, for all analyzed matrix types, i.e., copper-base-, silicate-, and sulfide-reference materials. Consequently, it is possible to determinate major and minor element concentrations in copper alloys, i.e., Cu, Sn and Zn, using silicate and sulfide reference materials as external calibrators, without any matrix effect and over a wide range of concentrations (from wt.% to ppm). Equally, Cu, Sn and Zn concentrations can be precisely determined in sulfides using homogeneous alloys (reference) materials as an external calibrator. Thus, it is possible to determine Cu, Sn and Zn in copper-base materials and their ore minerals, mostly sulfides, in a single analytical session, without requiring specific external calibrators for each matrix type. In contrast, immiscible elements in copper matrix, such as Pb and Fe show notable differences in their relative sensitivity values and ratios for different matrix-materials analyzed, implying that matrix-matched external calibrations remain to be applied for their trace quantification. 展开更多
关键词 Copper Alloys Reference Material Matrix effect In-Situ Metal Determinations NEAR-INFRARED Femtosecond Laser Ablation-inductively coupled plasma-Mass SPECTROMETRY (NIR fs-LA-ICP-MS)
下载PDF
Quantification of trace amounts of impurities in high purity cobalt by high resolution inductively coupled plasma mass spectrometry 被引量:10
4
作者 XIE Hualin HUANG Kelong +1 位作者 NIE Xidu TANG Yougen 《Rare Metals》 SCIE EI CAS CSCD 2007年第3期286-291,共6页
A An analytical method using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) for rapid simultaneous determination of 24 elements (Be, Mg, A1, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Ge, As, Se, ... A An analytical method using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) for rapid simultaneous determination of 24 elements (Be, Mg, A1, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Ge, As, Se, Mo, Ag, Cd, Sn Sb, Ba, Pt, Au, and Pb) in high purity cobalt was described. Sample digestions were performed in closed microwave vessels using HNO3 and HCI. The matrix effects because of the presence of excess HCI and Co were evaluated. The usefulness of high mass resolution for overcoming some spectral interference was demonstrated. The optimum conditions for the determination were tested and discussed. The standard addition method was employed for quantitative analysis. The detection limits were 0.016-1.50 ].tg·g^-1, the recovery ratios were 92.2%-111.2%, and the RSD was less than 3.6%. The method was accurate, quick, and convenient. It was applied to the determination of trace impurities in high purity cobalt with satisfactory results. 展开更多
关键词 high resolution inductively coupled plasma mass spectrometry high purity cobalt trace impurities matrix effect standard addition method
下载PDF
Determination of trace elements in high purity nickel by high resolution inductively coupled plasma mass spectrometry 被引量:11
5
作者 聂西度 梁逸曾 +1 位作者 唐有根 谢华林 《Journal of Central South University》 SCIE EI CAS 2012年第9期2416-2420,共5页
The contents ofMg, Al, Si, Ti, Cr, Mn, Fe, Co, Cu, Ga, As, Se, Cd, Sb, Pb and Bi in high purity nickel were determined by high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). The sample was diss... The contents ofMg, Al, Si, Ti, Cr, Mn, Fe, Co, Cu, Ga, As, Se, Cd, Sb, Pb and Bi in high purity nickel were determined by high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). The sample was dissolved in HNO3 and HCI by microwave digestion. Most of the spectral interferences could be avoided by measuring in the high resolution mode. The matrix effects because of the presence of excess HC1 and nickel were evaluated. Correction for matrix effects was made using Sc, Rh and T1 as internal standards. The optimum conditions for the determination were tested and discussed. The detection limits range from 0.012 to 1.76 ~tg/g depending on the type of elements. The applicability of the proposed method is also validated by the analysis of high purity nickel reference material (NIST SRM 671). The relative standard deviation (RSD) is less than 3.3%. Results for determination of trace elements in high purity nickel were presented. 展开更多
关键词 high resolution inductively coupled plasma mass spectrometry high purity nickel trace element matrix effect internal standard
下载PDF
Quantification of Trace Amounts of Impurities in High Purity Cobalt by High Resolution Inductively Coupled Plasma Mass Spectrometry 被引量:3
6
作者 Hua Lin XIE Xi Du NIE You Gen TANG 《Chinese Chemical Letters》 SCIE CAS CSCD 2006年第8期1077-1080,共4页
An analytical method using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) for rapid simultaneous determination of Be, Mg, Al, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Ge, As, Se, Mo, Ag, Cd, Sn, ... An analytical method using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) for rapid simultaneous determination of Be, Mg, Al, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Ge, As, Se, Mo, Ag, Cd, Sn, Sb, Ba, Pt, Au and Pb in high purity cobalt was described. Sample digestions were performed in closed microwave vessels using HNO3 and HCl. The matrix effects due to the presence of excess HCl and Co were evaluated. The usefulness of high mass resolution for overcoming some spectral interference was demonstrated. The optimum conditions for the determination was tested and discussed. Correction for matrix effects, Sc, Rh and Bi were used as internal standards. The detection limits is 0.003-0.57 μg/g, the recovery ratio is 92.2%-111.2%, and the RSD is less than 3.6%. The method is accurate, quick and convenient. It has been applied to the determination of trace impurities in high purity cobalt with satisfactory results. 展开更多
关键词 High resolution inductively coupled plasma mass spectrometry high purity cobalt trace impurities matrix effect spectral interference internal standards.
下载PDF
Trace amounts of impurities in electrolytic manganese metal by sector field inductively coupled plasma mass spectrometry 被引量:2
7
作者 聂西度 梁逸曾 +1 位作者 唐有根 谢华林 《Journal of Central South University》 SCIE EI CAS 2013年第12期3385-3390,共6页
An analytical method, using sector field inductively coupled plasma mass spectrometry (SF-ICP-MS) for rapid simultaneous determination of Be, Na, Mg, Si, Ca, Ti, V, Cr, Fe, Co, Ni, Cu, Zn, As, Sn, Sb, Pb and Bi in e... An analytical method, using sector field inductively coupled plasma mass spectrometry (SF-ICP-MS) for rapid simultaneous determination of Be, Na, Mg, Si, Ca, Ti, V, Cr, Fe, Co, Ni, Cu, Zn, As, Sn, Sb, Pb and Bi in electrolytic manganese metal, was described. At the beginning, the samples were decomposed by HNO3 and H2504, and then analyzed by SF-ICP-MS. Most of the spectral interferences could be avoided by measuring in different mass resolution modes. The matrix effects due to the excess of sulfuric acid and Mn were evaluated. Correction of matrix effects was conducted by using the internal standard elements. The optimum condition for the determination was investigated and discussed. The detection limit is in the range of 0.001-0.169 gg/L. The current method is applied to the determination of trace impurities in electrolytic manganese metal. And experiments show that good results can be obtained much faster, more accurately and conveniently by current method. 展开更多
关键词 sector field inductively coupled plasma mass spectrometry electrolytic manganese IMPURITIES spectral interferences matrix effects
下载PDF
Two-Dimensional Self-Consistent Kinetic Model for Solenoidal Inductively Coupled Plasma 被引量:1
8
作者 毛明 戴忠玲 王友年 《Plasma Science and Technology》 SCIE EI CAS CSCD 2007年第1期30-34,共5页
A two-dimensional self-consistent kinetic model was developed to study the influence of the various factors on the electron energy distribution function. These factors include gas pressure the driving frequency, the ... A two-dimensional self-consistent kinetic model was developed to study the influence of the various factors on the electron energy distribution function. These factors include gas pressure the driving frequency, the radius and length of the inductively coupled plasma equipment, the amplitude of the radio-frequency coil current, and the number of turns of rf coils. The spatial profiles of the rf electric field and power density have also been calculated under the same parameters. Numerical results show that the electron energy distribution functions are significantly modified and the spatial profiles of the rf electric field and rf power density are also demonstrated. 展开更多
关键词 TWO-DIMENSIONAL inductively coupled plasma electron energy distribution power deposition
下载PDF
Effectiveness of Radiofrequency Inductively Coupled Plasma Sources for Space Propulsion 被引量:1
9
作者 V. A. Riaby P E. Masherov +1 位作者 V. A. Obukhov V. P. Savinov 《高电压技术》 EI CAS CSCD 北大核心 2013年第9期2077-2088,共12页
Evolution of geometric forms of antenna coils for radiofrequency(RF)inductively coupled plasma(ICP)sources is analyzed.Top effectiveness of flat ICPSs generating plasma"tablet"is shown.Especially effective a... Evolution of geometric forms of antenna coils for radiofrequency(RF)inductively coupled plasma(ICP)sources is analyzed.Top effectiveness of flat ICPSs generating plasma"tablet"is shown.Especially effective are ICPSs using antenna coils enhanced with ferromagnetic cores(FMICPS).It is found that the design of flat ICPSs is simpler and more convenient for the arrangement of plasma diagnostics in comparison with ICPSs of other geometries.Effective flat FMICPS models of different diameters ranging from 10 cm to 100cm are considered.Recommendations are given for development engineers dealing with ICPS devices in general and with radio frequency ion thrusters(RITs)in particular. 展开更多
关键词 电感耦合等离子体 等离子体源 空间推进 射频 等离子体诊断 几何形式 ICPS 离子推进器
下载PDF
Inductively Coupled Plasma Mass Spectrometry as a Reference Method to Evaluate Serum Calcium Measurement Bias and the Commutability of Processed Materials during Routine Measurements 被引量:2
10
作者 Hai-Jian Zhao Meng-Lei Ge +6 位作者 Yin Yan Tian-Jiao Zhang Jie Zeng Wei-Yan Zhou Yu-Fei Wang Qing-Hui Meng Chuan-Bao Zhang 《Chinese Medical Journal》 SCIE CAS CSCD 2018年第13期1584-1590,共7页
Background: Measuring total serum calcium is important for the diagnosis of diseases. Currently, results from commercial kits for calcium measurement are variable. Generally, the performance of serum calcium measurem... Background: Measuring total serum calcium is important for the diagnosis of diseases. Currently, results from commercial kits for calcium measurement are variable. Generally, the performance of serum calcium measurements is monitored by external quality assessment (EQA) or proficiency testing schemes. However, the commutability of the EQA samples and calibrators is often unknown, which limits the effectiveness of EQA schemes. The aim of this study was to evaluate the bias of serum calcium measurements and the commutability of processed materials. Methods: Inductively coupled plasma mass spectrometry was applied as a comparative method, and 14 routine methods were chosen as test methods. Forty-eight serum samples from individual patients and 25 processed materials were quantified. A scatter plot was generated from patient samples, and 95% prediction intervals were calculated to evaluate the commutability of the processed materials and measurement bias at three concentration levels was used to determine the accuracy of routine assays. Results: All assays showed high precision (total coefficient of variation [CV] 〈2.26%) and correlation coefficients (r 〉 0.99). For all assays, the mean bias for the 48 patient samples ranged from 0.13 mmol/L to 0.00 mmol/L (-5.61 0.01%), and the ranges for the three concentrations were 0.10-0.04 mmoUL (-5.71-2.35%), -0.14-0.01 mmol/L (-5.80-0.30%), and -0.19-0.04 mmol/L (-6.24-1.22%). The EQA samples, calibrators, and animal sera exhibited matrix effects in some assays; human serum pools were commutable in all assays; certificate reference materials were commutable in most assays, and only GBW09152 exhibited a matrix effect in one assay: and aqueous reference materials exhibited matrix effects in most assays. Conclusions: Biases for most assays were within the acceptable range, although the accuracy of some assays needs improvement. Human serum pools prepared from patient samples were commutable, and the other tested materials exhibited a matrix effect. 展开更多
关键词 Calibration Bias COMMUTABILITY inductively coupled plasma Mass Spectrometry Matrix effect Serum Calcium
原文传递
Power transfer efficiency in an air-breathing radio frequency ion thruster
11
作者 黄高煌 李宏 +1 位作者 高飞 王友年 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第7期430-438,共9页
Due to a series of challenges such as low-orbit maintenance of satellites, the air-breathing electric propulsion has got widespread attention. Commonly, the radio frequency ion thruster is favored by low-orbit mission... Due to a series of challenges such as low-orbit maintenance of satellites, the air-breathing electric propulsion has got widespread attention. Commonly, the radio frequency ion thruster is favored by low-orbit missions due to its high specific impulse and efficiency. In this paper, the power transfer efficiency of the radio frequency ion thruster with different gas compositions is studied experimentally, which is obtained by measuring the radio frequency power and current of the antenna coil with and without discharge operation. The results show that increasing the turns of antenna coils can effectively improve the radio frequency power transfer efficiency, which is due to the improvement of Q factor. In pure N_2 discharge,with the increase of radio frequency power, the radio frequency power transfer efficiency first rises rapidly and then exhibits a less steep increasing trend. The radio frequency power transfer efficiency increases with the increase of gas pressure at relatively high power, while declines rapidly at relatively low power. In N_(2)/O_(2) discharge, increasing the N_(2) content at high power can improve the radio frequency power transfer efficiency, but the opposite was observed at low power. In order to give a better understanding of these trends, an analytic solution in limit cases is utilized, and a Langmuir probe was employed to measure the electron density. It is found that the evolution of radio frequency power transfer efficiency can be well explained by the variation of plasma resistance, which is related to the electron density and the effective electron collision frequency. 展开更多
关键词 radio frequency ion thruster inductively coupled plasma power transfer efficiency analytic solution
下载PDF
Power characteristics of multiple inductively coupled RF discharges inside a metallic chamber
12
作者 Dane LOJEN Rok ZAPLOTNIK +2 位作者 Miran MOZETIC Alenka VESEL Gregor PRIMC 《Plasma Science and Technology》 SCIE EI CAS CSCD 2022年第1期70-76,共7页
The characteristics of an innovative configuration of multiple radiofrequency(RF)coils immersed in a large metallic chamber are presented.Water-cooled copper coils were mounted within the slits of double-walled glass ... The characteristics of an innovative configuration of multiple radiofrequency(RF)coils immersed in a large metallic chamber are presented.Water-cooled copper coils were mounted within the slits of double-walled glass tubes,which were immersed into a stainless-steel chamber.The coils were connected in parallel to a gamma-type matching network,powered by an RF generator operating at industrial frequency.Adjustable leads enabled optimisation of the line impedances and thus uniformly distributed RF power across the four coils.Transitions from E-to H-mode and vice versa were measured for all coils at various oxygen pressures between 5 and 25 Pa.A uniform plasma was sustained in H-mode at the absorbed power threshold,which increased monotonously with increasing pressure in the metallic chamber.All coils exhibit the same E-to H-mode transition hysteresis and need the same amount of power for transitioning from E-to H-mode.The setup enables maintaining uniform plasma in virtually any number of coils at high power without the risk of arcing and without the dead volume typical for a classical configuration with coils mounted outside the metallic chamber. 展开更多
关键词 inductively coupled plasma large-area plasma E-to H-mode transition high power
下载PDF
Three-dimensional discharge simulation of inductively coupled plasma (ICP) etching reactor 被引量:2
13
作者 AN YiRan LU YiJia +1 位作者 LI DongSan CHEN YaoSong 《Science China(Technological Sciences)》 SCIE EI CAS 2008年第6期674-682,共9页
More and more importance has been attached to inductively coupled plasma (ICP) in semiconductor manufacture. For a deep understanding of the plasma discharge process in the etching reactor, this study made a three-dim... More and more importance has been attached to inductively coupled plasma (ICP) in semiconductor manufacture. For a deep understanding of the plasma discharge process in the etching reactor, this study made a three-dimensional simulation on the Ar plasma discharge process with the commercial software CFD-ACE, which is according to the real experiment conditions and data supplied by North Microelec-tronic Corporation. The error of the simulation results is in the range of ±20% with credibility. The numerical results show that the three-dimentional spatial distribu-tion of electron density is reduced from the chamber center to the wall. The distri-bution of electron density, electron temperature and power deposition is related to the shape and placement of the coil. 展开更多
关键词 inductively coupled plasma ELECTRON density ELECTRON temperature power deposition
原文传递
Balmer H_α,H_β and H_γ Spectral Lines Intensities in High-Power RF Hydrogen Plasmas 被引量:1
14
作者 王松柏 雷光玖 +1 位作者 刘东平 杨思泽 《Plasma Science and Technology》 SCIE EI CAS CSCD 2014年第3期219-222,共4页
Hα(Balmer-alpha), Hβ (Balmer-beta) and Hγ (Balmer-gamma) spectral line inten- sities in atomic hydrogen plasma are investigated by using a high-power RF source. The intensities of the Hα, Hβ and Hγ spectra... Hα(Balmer-alpha), Hβ (Balmer-beta) and Hγ (Balmer-gamma) spectral line inten- sities in atomic hydrogen plasma are investigated by using a high-power RF source. The intensities of the Hα, Hβ and Hγ spectral lines are detected by increasing the input power (0-6 kW) of ICPs (inductively coupled plasmas). With the increase of net input power, the intensity of Hα im- proves rapidly (0-2 kW), and then reaches its dynamic equilibrium; the intensities of Hβ can be divided into three processes: obvious increase (0-2 kW), rapid increase (2-4 kW), almost constant (4-6 kW); while the intensities of Hγ increase very slowly. The energy levels of the excited hydro- gen atoms and the splitting energy levels produced by an obvious Stark effect play an important role in the results. 展开更多
关键词 Keywords: high-power RF (radio frequency) source ICPs inductively coupled plasmas) and spectral lines intensity Boltzmann distribution law Stark effect transitionprobability
下载PDF
Self-consistent Kinetic Description of the Low-Pressure Solenoidal Inductively Coupled Argon Discharge
15
作者 毛明 王友年 《Plasma Science and Technology》 SCIE EI CAS CSCD 2005年第1期2640-2644,共5页
Using an one-dimensional slab model, we have studied the electron energy distribution, the anomalous skin effect, and power absorption in the solenoidal-inductively-coupled argon discharge under low pressures (≤ 1.33... Using an one-dimensional slab model, we have studied the electron energy distribution, the anomalous skin effect, and power absorption in the solenoidal-inductively-coupled argon discharge under low pressures (≤ 1.33 Pa). The electron energy distribution function and rf electromagnetic field in the plasma are determined self-consistently by the linearized Bolztmann equation incorporating with the Maxwell equations. The numerical results show that, at low pressures, the electron energy distribution function exhibits a non-Maxwellian distribution with a long high-energy tail. The anomalous skin effect is greatly enhanced under low pressures and the negative power absorption is also obtained. 展开更多
关键词 inductively coupled plasma electron energy distribution anomalous skin effect power absorption
下载PDF
The effect of discharge conditions of ICP etching reactor on plasma parameters
16
作者 Yijia Lu Yaosong Chen Yiran An LTCS, College of Engineering, Peking University,100871 Beijing, China 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2009年第6期769-776,共8页
This study investigated the inductively coupled plasma etching reactor and RF coils developed by North Microelectronic Corporation. Full three dimensional simulations were made at different discharge conditions. The s... This study investigated the inductively coupled plasma etching reactor and RF coils developed by North Microelectronic Corporation. Full three dimensional simulations were made at different discharge conditions. The simulations examined and compared the distribution and non-uniformity of several plasma parameters at a fixed position upon the wafer at different pressures and coil currents. These parameters included electron density, electron temperature and power deposition. The results demonstrate that the electron density, power deposition and uniformity increase with either higher pressure or stronger coil currents, while the electron temperature decreases at this condition. Coil number increase can reduce the non-uniformity of parameters in the spatial distribution. The linear relationship between power deposition and electron density does not always exist. The comparison between simulation results and experiment results is also presented in the paper. 展开更多
关键词 inductively coupled plasma. Electron densityElectron temperature ~ power deposition - RF coils
下载PDF
电感耦合等离子体发射光谱法测定土壤中有效磷的不确定度评价
17
作者 韩梅 韩文红 +3 位作者 张伯研 贾娜 张威 孔祥科 《四川环境》 2024年第3期162-166,共5页
为准确测定土壤中有效磷的含量,采用电感耦合等离子体光谱仪进行测定,并对测定过程中相关因素引起的不确定度进行评定。整个实验过程中不确定度来源主要包括以下5个方面:(1)样品称量时引入的不确定度u(m);(2)加入浸提液时浸提液体积V引... 为准确测定土壤中有效磷的含量,采用电感耦合等离子体光谱仪进行测定,并对测定过程中相关因素引起的不确定度进行评定。整个实验过程中不确定度来源主要包括以下5个方面:(1)样品称量时引入的不确定度u(m);(2)加入浸提液时浸提液体积V引入的不确定度u(V);(3)标准溶液配置时引入的不确定度u(C_(s));(4)标准曲线拟合引入的不确定度u(C0);(5)样品测量重复性引入的不确定度u(R)。结果表明,样品测量重复性、标准溶液配置、标准曲线拟合在整个实验中引入的不确定度影响较大。因此,在实际样品测定过程中,一定要注意对结果有影响的不确定度因素,加强质量控制,使结果准确可靠。 展开更多
关键词 电感耦合等离子体发射光谱法 土壤 有效磷 不确定度
下载PDF
ICP-QQQ-MS法分析婴幼儿谷物辅助食品中镉含量的干扰及其校正 被引量:1
18
作者 蔡玮 赵博 +4 位作者 赵少雷 陈欢欢 李潇 逯海 韦超 《食品科学》 EI CAS CSCD 北大核心 2024年第14期234-239,共6页
建立三重串联四极杆电感耦合等离子体质谱(inductively coupled plasma triple quadrupole mass spectrometry,ICP-QQQ-MS)法测定婴幼儿谷物辅助食品中镉(Cd)含量的方法。研究单四极杆氦气碰撞模式(SQ-He)、串联四极杆氦气碰撞模式(QQQ-... 建立三重串联四极杆电感耦合等离子体质谱(inductively coupled plasma triple quadrupole mass spectrometry,ICP-QQQ-MS)法测定婴幼儿谷物辅助食品中镉(Cd)含量的方法。研究单四极杆氦气碰撞模式(SQ-He)、串联四极杆氦气碰撞模式(QQQ-He)、串联四极杆氧气反应模式(QQQ-O_(2))3种碰撞/反应模式下质谱测量中存在的各类干扰,并进行逐一分析、消除。结果显示,抗基体、抗氧化物和多原子离子干扰能力均为QQQ-O_(2)>QQQ-He>SQ-He,采用QQQ-O_(2)模式联合标准加入法可获得更为准确的干扰消除效果。通过引入干扰校正方程,有效解决由于同量异位素锡(Sn)干扰导致的Cd同位素丰度比与天然丰度比不一致问题。QQQ-O_(2)模式下同位素稀释质谱法与标准加入法测量Cd的结果等效一致,证明婴幼儿谷物辅助食品中Cd测量时受到的基体效应和质谱干扰被有效消除。所建方法为使用ICP-QQQ-MS准确测定复杂基体样品中Cd提供重要参考。 展开更多
关键词 三重串联四极杆电感耦合等离子体质谱 质谱干扰 同位素稀释质谱 基体效应
下载PDF
基于ICP的Ar等离子体干法刻蚀Ti/Ni/Ag薄膜
19
作者 黄梦茹 卢林红 +2 位作者 郭丰杰 马奎 杨发顺 《半导体技术》 CAS 北大核心 2024年第10期893-898,共6页
在电感耦合等离子体(ICP)刻蚀工艺中,选择合适的刻蚀条件对Ti/Ni/Ag薄膜的刻蚀至关重要。使用氩气(Ar)作为刻蚀气体,研究了射频偏压功率、气体体积流量、腔体压强、刻蚀时间等多个参数对功率芯片背面Ti/Ni/Ag薄膜刻蚀深度的影响,并优化... 在电感耦合等离子体(ICP)刻蚀工艺中,选择合适的刻蚀条件对Ti/Ni/Ag薄膜的刻蚀至关重要。使用氩气(Ar)作为刻蚀气体,研究了射频偏压功率、气体体积流量、腔体压强、刻蚀时间等多个参数对功率芯片背面Ti/Ni/Ag薄膜刻蚀深度的影响,并优化刻蚀工艺参数。实验结果表明,调节射频偏压功率和Ar体积流量可以显著影响刻蚀速率,进而对薄膜的微结构进行有效调控。通过优化工艺参数,在射频偏压功率300 W、Ar体积流量40 cm^(3)/min、腔体压强1.2 Pa、刻蚀时间50 min下,芯片Ti/Ni/Ag薄膜的刻蚀深度达到283.25μm,有效提升了刻蚀效率和刻蚀精度。 展开更多
关键词 Ti/Ni/Ag薄膜 电感耦合等离子体(ICP) 刻蚀深度 AR 射频偏压功率
下载PDF
Evaluation of a gate-first process for AlGaN/GaN metal-oxide-semiconductor heterostructure field-effect transistors with low ohmic annealing temperature 被引量:1
20
作者 李柳暗 张家琦 +1 位作者 刘扬 敖金平 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第3期445-447,共3页
In this paper, TiN/A1Ox gated A1GaN/GaN metal-oxide-semiconductor heterostructure field-effect transistors (MOS- HFETs) were fabricated for gate-first process evaluation. By employing a low temperature ohmic process... In this paper, TiN/A1Ox gated A1GaN/GaN metal-oxide-semiconductor heterostructure field-effect transistors (MOS- HFETs) were fabricated for gate-first process evaluation. By employing a low temperature ohmic process, ohmic contact can be obtained by annealing at 600 ℃ with the contact resistance approximately 1.6 Ω.mm. The ohmic annealing process also acts as a post-deposition annealing on the oxide film, resulting in good device performance. Those results demonstrated that the TiN/A1Ox gated MOS-HFETs with low temperature ohmic process can be applied for self-aligned gate AIGaN/GaN MOS-HFETs. 展开更多
关键词 metal-oxide-semiconductor heterostructure field-effect transistors low temperature ohmic pro-cess inductively coupled plasma
下载PDF
上一页 1 2 8 下一页 到第
使用帮助 返回顶部