期刊文献+
共找到2,152篇文章
< 1 2 108 >
每页显示 20 50 100
CORRECTION OF WING INTERFERENCE WITH KALMAN FILTERING IN INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION SPECTROMETRY
1
作者 Jin Fu YANG Zhe Xiu PIAO +2 位作者 Xian Jin ZENG Zhuo Yong ZHANG Xin Hai CHEN 《Chinese Chemical Letters》 SCIE CAS CSCD 1992年第3期193-196,共4页
A Kalman filter was developed for correction of wing interference in ICP-AES.Modeling wing interference theoretically instead of experimentally, the filter can compensate the shift in wavelength position in scans, and... A Kalman filter was developed for correction of wing interference in ICP-AES.Modeling wing interference theoretically instead of experimentally, the filter can compensate the shift in wavelength position in scans, and therefore reduce the effect of the interference on detection limit. 展开更多
关键词 LINE CORRECTION OF WING INTERFERENCE WITH KALMAN FILTERING IN inductively coupled plasma atomic emission SPECTROMETRY LA
下载PDF
A Perspective of Laser Sampling for Inductively Coupled Plasma-Atomic Emission Spectro metry for Rock and Mineral Analysis
2
作者 Lin Shoulin Peng ZhaofengChina University of Geosciences , Wuhan 430074 《Journal of Earth Science》 SCIE CAS CSCD 1992年第1期120-128,共9页
The development of laser sampling for optical emission spectrometry is reviewed . Advantages and limitations of pulsed laser sampling are compared with those of continuous laser sampling . A novel method of laser samp... The development of laser sampling for optical emission spectrometry is reviewed . Advantages and limitations of pulsed laser sampling are compared with those of continuous laser sampling . A novel method of laser sampling of liquid samples for inductively coupled plasma -atomic emission spectrometry has been proposed , and its analytical performance investigated.Experimental results showed that,as a method of sample introduction , laser vaporization of liquid samples enjoyed certain advantages , e.g.,much higher sensitivity, much lower detection limit and reduced sample volume , over solution nebulization . A perspective of the application of laser sampling-inductively coupled plasma - actomic emission spectrometry for rock and mineral analysis is estimated as well. 展开更多
关键词 continuous laser sampling complete laser vaporization of samples inductively coupled plasma-atomic emission spectrometry solid sample liquid sample rock and mineral analysis .
下载PDF
Diagnostics of Argon Inductively Coupled Plasma and Dielectric Barrier Discharge Plasma by Optical Emission Spectroscopy
3
作者 张家良 俞世吉 +1 位作者 马滕才 邓新绿 《Plasma Science and Technology》 SCIE EI CAS CSCD 2001年第4期883-890,共8页
An experimental setup was built up to carry out radio frequency (RF) inductively coupled plasma (ICP) and dielectric barrier discharge (DBD), and to depict the optical emission spectra (OES) of the discharges. OES fro... An experimental setup was built up to carry out radio frequency (RF) inductively coupled plasma (ICP) and dielectric barrier discharge (DBD), and to depict the optical emission spectra (OES) of the discharges. OES from argon ICP and DBD plasmas in visible and near ultraviolet region were measured. For argon ICP, the higher RF power input (higher than 500 W for our machine), the higher degree of argon plasma ionization. But that doesn't mean a higher mean electron energy. With the increase in the power input, the mean electron energy increases slightly, whereas the density of electron increases apparently On the contrary, argon DBD discharge behaves in the manner of a pulsed DC discharge on optical emission spectroscopy and V-I characteristics. DBD current is composed of a series of pulses equally spaced in temporal domain. The Kinetics of DBD emission strength is mainly governed by the frequency of the current pulse. 展开更多
关键词 In ICP Diagnostics of Argon inductively coupled plasma and Dielectric Barrier Discharge plasma by Optical emission spectroscopy
下载PDF
基体匹配-电感耦合等离子体原子发射光谱(ICP-AES)法测定砂岩型铀矿中的铀硅等主量元素
4
作者 吴领军 梁亚丽 +4 位作者 马琳 阿丽莉 杨珍 贺攀红 吴培源 《中国无机分析化学》 北大核心 2025年第2期241-248,共8页
砂岩型铀矿样品按传统石墨坩埚碱熔方法,受坩埚和熔剂的影响,熔融物容易在坩埚内壁粘附,很难完全将熔融物导出溶解定容,致使检测结果偏低,且过程复杂冗长。选择无水偏硼酸锂为熔剂,石墨坩埚内铺垫石墨粉于马弗炉内1000℃熔融样品20 min... 砂岩型铀矿样品按传统石墨坩埚碱熔方法,受坩埚和熔剂的影响,熔融物容易在坩埚内壁粘附,很难完全将熔融物导出溶解定容,致使检测结果偏低,且过程复杂冗长。选择无水偏硼酸锂为熔剂,石墨坩埚内铺垫石墨粉于马弗炉内1000℃熔融样品20 min,超声溶解制备砂岩型铀矿样品溶液,采用三通进样,并对标准溶液系列进行基体匹配绘制校准曲线,测定了样品中U、Si等主量元素。优化了样品熔融时间、温度、偏硼酸锂用量等条件,三通进样考察了共存待测主量元素硅对其他元素的影响,采用基体匹配法消除基体影响,确定元素分析谱线,对砂岩型铀矿国家标准物质及实际样品进行测定,各元素测定结果与标准值相符,相对偏差RE在-3.0%~2.8%,方法精密度RSD在1.2%~3.2%,样品加标回收率在97.3%~104%,方法检出限为0.60~51.69μg/g,满足分析测试要求,为砂岩型铀矿元素的分析检测提供了测量范围宽、快速、准确的检测方法。 展开更多
关键词 无水偏硼酸锂 电感耦合等离子体原子发射光谱法 砂岩型铀矿 基体匹配 主量元素
下载PDF
碱熔-电感耦合等离子体原子发射光谱法(ICP-AES)法测定锡矿中的锡、硅、锌、铜、铁、铅、砷、铋、锑
5
作者 郑程 陈雯 +2 位作者 周峰 毛林夏 张鸟飞 《中国无机分析化学》 北大核心 2025年第2期264-270,共7页
为解决锡矿石主次元素常规分析法流程长、过程复杂、成本高、仅能单元素测定等问题,通过考察熔剂种类、混合溶剂比例、熔剂与试样质量比例、熔样温度、熔样时间等条件,建立了电感耦合等离子体原子发射光谱法(ICP-AES)法同时测定锡矿中... 为解决锡矿石主次元素常规分析法流程长、过程复杂、成本高、仅能单元素测定等问题,通过考察熔剂种类、混合溶剂比例、熔剂与试样质量比例、熔样温度、熔样时间等条件,建立了电感耦合等离子体原子发射光谱法(ICP-AES)法同时测定锡矿中锡、硅、锌、铜、铁、铅、砷、铋、锑等9种主次元素的方法。实验表明,采用混合熔剂(四硼酸锂∶偏硼酸锂为1∶4)与试样质量比为20∶1,在铂坩埚中1050℃熔融60 min,60 mL盐酸(1+2)溶液中加热浸取,各元素标准工作曲线的线性相关系数均大于0.9999,方法检出限为0.004~0.08μg/mL,测定标准物质的相对标准偏差在1.0%~5.5%,相对误差在0~9.2%。方法检出限低、精密度好、准确度高,能够满足难溶锡矿中多种元素的同时测定。 展开更多
关键词 锡矿 碱熔 四硼酸锂 偏硼酸锂 电感耦合等离子体原子发射光谱法(icp-aes)
下载PDF
Elemental Content in Brown Rice by Inductively Coupled Plasma Atomic Emission Spectroscopy Reveals the Evolution of Asian Cultivated Rice 被引量:4
6
作者 Yawen Zeng Luxiang Wang +4 位作者 Juan Du Jiafu Liu Shuming Yang Xiaoying Pu Fenghui Xiao 《Journal of Integrative Plant Biology》 SCIE CAS CSCD 2009年第5期466-475,共10页
The phylogenetic relationship for classification traits and eight mineral elements in brown rice (Oryza sativa L.) from Yunnan Province in China was carried out using microwave assisted digestion followed by inducti... The phylogenetic relationship for classification traits and eight mineral elements in brown rice (Oryza sativa L.) from Yunnan Province in China was carried out using microwave assisted digestion followed by inductively coupled plasma atomic emission spectroscopy, and the analytical procedures were carefully controlled and validated. In general, the results show that the mean levels of K, Ca, Mg, Fe and Cu in brown rice for 789 accessions of rice landraces was distinctly lower than that of improved cultivars. They further demonstrate that Ca plays an important role in the differentiation of subspecies indica-japonica, especially to enhance adaptation of cold stress, and that five mineral elements in brown rice enhance the eurytopicity from landrace to improved cultivar. Hierarchical cluster analysis, using average linkage from SPSS software based on eight mineral elements in brown rice, showed that Yunnan rice could be grouped into rice landrace and improved cultivar, with the rice landrace being further clustered into five subgroups, and that, interestingly, purple rice does not cluster with either of the groups. Our present data confirm that indica is the closest relative of late rice and white rice, and that they constitute rice landraces together, whereas japonica is the closest relatives of non-nuda, early-mid and glutinous rice. It is further shown that japonica, non-nuda, early-mid, glutinous, white and red rice might be more primitive than indica, nuda, late, non-glutinous and purple rice, respectively. 展开更多
关键词 brown rice core collection inductively coupled plasma atomic emission spectroscopy mineral element phylogenetic relationship
原文传递
Optical Emission Spectroscopic Studies of ICP Ar Plasma
7
作者 齐雪莲 任春生 +1 位作者 张健 马腾才 《Plasma Science and Technology》 SCIE EI CAS CSCD 2007年第5期578-581,共4页
The ion line of 434.8 nm and atom line of 419.8 nm of Ar plasma produced by an inductively coupled plasma (ICP) were measured by optical emission spectroscopy and the influences from the working gas pressure, radio-... The ion line of 434.8 nm and atom line of 419.8 nm of Ar plasma produced by an inductively coupled plasma (ICP) were measured by optical emission spectroscopy and the influences from the working gas pressure, radio-frequency (RF) power and different positions in the discharge chamber on the line intensities were investigated in this study. It was found that the intensity of Ar atom line increased firstly and then saturated with the increase of the pressure. The line intensity of Ar^+, on the other hand, reached a maximum value and then decreased along with the pressure. The intensity of the line in an RF discharge also demonstrated a jumping mode and a hysteresis phenomenon with the RF power. When the RF power increased to 400 W, the discharge jumped from the E-mode to the H-mode where the line intensity of Ar atom demonstrated a sudden increase, while the intensity of Ar^+ ion only changed slightly. If the RF power decreased from a high value, e.g., 1000 W, the discharge would jump from the H-mode back to the E-mode at a power of 300 W. At this time the intensities of Ar and Ar^+ lines would also decrease sharply. It was also noticed in this paper that the intensity of the ion line depended on the detective location in the chamber, namely at the bottom of the chamber the line was more intense than that in the middle of the chamber, but less intense than at the top, which is considered to be related to the capacitance coupling ability of the ICP plasma in different discharge areas. 展开更多
关键词 optical emission spectroscopy inductively coupled plasma spectral line intensity AR
下载PDF
ICP-AES法和原子荧光法检测硫熏处理对山药中重金属的影响 被引量:1
8
作者 刘亚群 陈良辉 +6 位作者 张勇 张慷 孙延杰 谢耀庆 张泽坤 郑玉忠 张振霞 《现代食品》 2024年第11期147-151,163,共6页
目的:研究硫黄熏蒸对山药中重金属含量的影响,为评估硫黄熏蒸的安全性及山药加工工艺提供科学依据。方法:选取13批不同产地的硫黄对山药进行熏蒸处理,使用微波消解法对样品进行前处理,并通过电感耦合等离子体原子发射光谱法与原子荧光... 目的:研究硫黄熏蒸对山药中重金属含量的影响,为评估硫黄熏蒸的安全性及山药加工工艺提供科学依据。方法:选取13批不同产地的硫黄对山药进行熏蒸处理,使用微波消解法对样品进行前处理,并通过电感耦合等离子体原子发射光谱法与原子荧光光谱分析法定量分析硫黄及熏蒸前后山药中汞(Hg)、砷(As)、铜(Cu)、镉(Cd)和铅(Pb)的含量。结果:13批硫黄中Pb、As、Hg含量偏高。硫黄熏蒸后,山药中Pb含量普遍上升,且部分样品中As、Hg和Cu含量亦有增加。结论:硫黄熏蒸可能导致重金属元素从硫黄迁移到山药中,因此应制定严格的硫黄熏蒸工艺规范,确保山药的安全性和质量,减少对人体健康的潜在风险。 展开更多
关键词 硫黄熏蒸 山药 重金属 电感耦合等离子体发射光谱法 原子荧光法
下载PDF
电感耦合等离子体原子发射光谱(ICP-AES)法测定石煤钒矿石中钒、铁、钛的含量 被引量:3
9
作者 严慧 戴长文 +3 位作者 叶明 王干珍 汤行 邓飞跃 《中国无机分析化学》 北大核心 2024年第3期324-329,共6页
研究一种快速准确测定石煤钒矿石中钒、铁、钛含量的方法对石煤钒矿检测行业的发展和石煤钒矿资源的开发利用、综合评价具有重要的意义。试样经过氧化钠在650℃完全熔融后保持1~3 min,取出冷却,热水浸提,盐酸酸化,定容稀释,选择V 292.40... 研究一种快速准确测定石煤钒矿石中钒、铁、钛含量的方法对石煤钒矿检测行业的发展和石煤钒矿资源的开发利用、综合评价具有重要的意义。试样经过氧化钠在650℃完全熔融后保持1~3 min,取出冷却,热水浸提,盐酸酸化,定容稀释,选择V 292.402 nm、Fe 259.940 nm、Ti 334.941 nm为分析谱线,利用电感耦合等离子体原子发射光谱法(ICP-AES),建立了石煤钒矿石中同时测定钒、铁、钛含量的方法。优化了钒、铁、钛元素的分析谱线和背景校正模式,采用全程序样品空白稀释配制的校准曲线消除盐度钠基影响;研究了坩埚、熔剂种类、直接碱熔与灼烧-碱熔前处理方式、酸度效应的影响。结果表明:方法检出限为0.009%~0.019%,定量限为0.027%~0.057%;铁、钛、钒3种元素浓度在0.10~30.0μg/mL时,校准曲线线性回归方程的相关系数均大于0.9999;采用国家一级标准物质(GBW07876、GBW07877、GBW07878)进行验证,相对标准偏差(RSD,n=12)为0.49%~0.87%,且测定值与标准值吻合。方法具有快速简便、精密度好、准确度高、同时测定钒、铁、钛等优点,满足石煤钒矿石化学分析检测需求,且可为石煤钒矿化学分析标准方法的建立提供技术支撑。 展开更多
关键词 过氧化钠 碱熔 石煤钒矿 电感耦合等离子体原子发射光谱法
下载PDF
电感耦合等离子体原子发射光谱(ICP-AES)法与EDTA滴定法联用测定含白云岩矿石中氟化钙
10
作者 鲁海妍 谢海东 +2 位作者 魏子茜 管美玲 罗海祥 《中国无机分析化学》 CAS 北大核心 2024年第7期954-962,共9页
氟化钙的测定目前较多采用的是国家标准方法GB/T 5195.1—2017和DZG93-05非金属矿萤石分析规程两种方法,前者测定范围≥60%,后者测定范围>3%。两种方法各有优缺点,然而却都无法满足矿石中含有白云岩时的测定。对于萤石矿与白云岩共... 氟化钙的测定目前较多采用的是国家标准方法GB/T 5195.1—2017和DZG93-05非金属矿萤石分析规程两种方法,前者测定范围≥60%,后者测定范围>3%。两种方法各有优缺点,然而却都无法满足矿石中含有白云岩时的测定。对于萤石矿与白云岩共存样品,直接采用国家标准方法,测定结果偏高,行业标准方法测定的精密度和准确度也很难达到要求。通过对方法进行优化,在样品中加入含钙冰乙酸分离碳酸钙,过滤残渣用混合酸分解后,直接取澄清液在Ca 317.933 nm处,使用电感耦合等离子体原子发射光谱法(ICP-AES)测定氟化钙含量,根据测定结果,将氟化钙质量分数大于15%的样品用EDTA滴定法再次测定。按照实验方法测定实际样品,两种方法测定结果的相对标准偏差(RSD,n=11)分别为1.9%和0.77%,加标回收率为97.9%~102%,可满足含白云岩矿石中氟化钙的准确测定。 展开更多
关键词 氟化钙 白云岩 电感耦合等离子体原子发射光谱法(icp-aes) EDTA滴定法
下载PDF
碱熔-标准物质法-电感耦合等离子体原子发射光谱(ICP-AES)法测定硅酸盐岩中10种主量元素 被引量:1
11
作者 李佳 谢小敏 +3 位作者 刘俊玲 高婧 黄文静 张雷 《中国无机分析化学》 北大核心 2024年第3期292-298,共7页
硅酸盐岩元素的准确测定是其地球化学分析研究的基础,其主量元素含量通常可以采用电感耦合等离子体原子发射光谱(ICP-AES)法测定,但其测定方法的系统性研究相对缺乏,尤其是样品前处理和基体干扰的有效消除两方面。前处理过程中,考察不... 硅酸盐岩元素的准确测定是其地球化学分析研究的基础,其主量元素含量通常可以采用电感耦合等离子体原子发射光谱(ICP-AES)法测定,但其测定方法的系统性研究相对缺乏,尤其是样品前处理和基体干扰的有效消除两方面。前处理过程中,考察不同熔剂用量对硅酸盐岩样品的分解能力,发现当熔剂与样品比例达到6∶1后,熔珠为纯色透明,经稀硝酸提取后溶液澄清,确定了硅酸盐岩前处理时熔剂与样品的最佳配比。测定过程中,通过考察基体匹配法和标准物质法两种基体干扰消除方法对测定结果的影响,发现当采用与岩性一致或者接近的标准物质绘制校准工作曲线时,基体干扰消除效果更好,更适用于测定硅酸盐岩10种主量元素含量。据此,建立了硅酸盐岩经偏硼酸锂熔融,稀硝酸振荡提取处理,以标准物质法绘制校准工作曲线,采用ICP-AES法同时测定SiO_(2)、Fe_(2)O_(3)、Al_(2)O_(3)、CaO、K_(2)O、MgO、Na_(2)O、TiO_(2)、P_(2)O_(5)、MnO 10种成分含量的方法。对岩石标准物质GBW07107进行分析测定,方法的相对标准偏差(RSD)为0.17%~0.75%,方法检出限为0.001%~0.016%,满足硅酸盐岩样品元素定量分析的要求,而且操作简单快速,环境污染小,适用于大批量样品分析。 展开更多
关键词 硅酸盐岩 主量元素 电感耦合等离子体原子发射光谱法 偏硼酸锂碱熔 基体干扰消除
下载PDF
超声消解ICP-AES测定铝合金中硅元素含量
12
作者 孔胜男 许实 《计量学报》 CSCD 北大核心 2024年第5期755-760,共6页
建立了超声密闭消解-电感耦合等离子体发射光谱法测定铝合金中硅元素含量的分析方法。通过优化样品前处理条件,对超声强度、密闭条件、超声温度、超声时间及酸的浓度进行筛选,选择合适的分析谱线,测定了铝合金中等含量硅。对不同硅含量... 建立了超声密闭消解-电感耦合等离子体发射光谱法测定铝合金中硅元素含量的分析方法。通过优化样品前处理条件,对超声强度、密闭条件、超声温度、超声时间及酸的浓度进行筛选,选择合适的分析谱线,测定了铝合金中等含量硅。对不同硅含量的铝合金ZLD105,ZBY5291,ZBY5091进行了精密度及准确度实验,其相对标准偏差(S_(RSD))在0.3%~0.7%,加标回收率在98.9%~101.0%。该方法分析成本低、快速、准确、方便,完全可应用于实际样品测试。 展开更多
关键词 化学计量 超声封闭消解 电感耦合等离子体发射光谱仪 铝合金
下载PDF
ICP-AES法测定钛合金用AlVSnCuFe中间合金中常量元素含量
13
作者 徐兴 杨平平 +1 位作者 刘雷雷 周恺 《钛工业进展》 CAS 2024年第5期38-41,共4页
采用电感耦合等离子体原子发射光谱仪(ICP-AES),在最佳仪器参数情况下,通过对溶解酸种类、称样量与定容体积、分析谱线、短时稳定性、共存元素干扰、工作曲线等进行研究,优化了试验条件,建立了钛合金用AlVSnCuFe中间合金中常量元素含量... 采用电感耦合等离子体原子发射光谱仪(ICP-AES),在最佳仪器参数情况下,通过对溶解酸种类、称样量与定容体积、分析谱线、短时稳定性、共存元素干扰、工作曲线等进行研究,优化了试验条件,建立了钛合金用AlVSnCuFe中间合金中常量元素含量的ICP-AES测定方法。该方法中Al和V元素测定范围为10.00%~50.00%,Fe和Cu元素测定范围为2.00%~10.00%,Sn元素测定范围为4.00%~20.00%;加标回收率为97.5%~103.2%,精密度(RSD)不大于2.5%。该方法具有检测准确度和稳定性好、效率高等特点,有效解决了AlVSnCuFe中间合金中常量元素的检测问题。 展开更多
关键词 钛合金 中间合金 AlVSnCuFe 电感耦合等离子体原子发射光谱法
下载PDF
湿法消解-电感耦合等离子体原子发射光谱(ICP-AES)法测定水凝胶中Mg的含量
14
作者 张芬芬 刘晓云 杨明 《中国无机分析化学》 CAS 北大核心 2024年第4期479-483,共5页
为了准确测定水凝胶样品中的金属元素含量,以Mg为例,通过优化电感耦合等离子体原子发射光谱(ICP-AES)仪参数,考察硝酸及硝酸-高氯酸湿法消解以及硝酸-微波消解法对于样品消解程度的不同,建立了湿法消解-ICP-AES法测定水凝胶中Mg绝对含... 为了准确测定水凝胶样品中的金属元素含量,以Mg为例,通过优化电感耦合等离子体原子发射光谱(ICP-AES)仪参数,考察硝酸及硝酸-高氯酸湿法消解以及硝酸-微波消解法对于样品消解程度的不同,建立了湿法消解-ICP-AES法测定水凝胶中Mg绝对含量的方法。结果表明,在110℃下用硝酸消解2 h与硝酸-高氯酸(1∶1)以及硝酸-微波消解得到的溶液相比,Mg含量几乎没有明显差别。在选定条件下,方法的日内和日间精密度良好,相对标准偏差(RSD,n=3)分别为0.38%和1.2%;加标回收率为97.6%~98.2%。方法准确、适用、可靠,适用于水凝胶中Mg的绝对含量测定,可为水凝胶中金属元素的定量分析提供一种借鉴。 展开更多
关键词 湿法消解 电感耦合等离子体原子发射光谱(icp-aes)法 水凝胶 Mg
下载PDF
ICP-AES法测定含银铅铋合金锭中7种杂质元素
15
作者 任利华 白灵 +1 位作者 郭亚梅 田卫 《中国标准化》 2024年第19期296-299,共4页
待测样品加入(1+1)硝酸溶解完全后,通过选择合适的称样量和待测试液稀释比消除铅铋的基体干扰。通过试验选择了分析谱线及其他仪器分析条件,在选定的仪器条件下,建立了电感耦合等离子体原子发射光谱法(ICP-AES)测定试液中镍、铜、铁、... 待测样品加入(1+1)硝酸溶解完全后,通过选择合适的称样量和待测试液稀释比消除铅铋的基体干扰。通过试验选择了分析谱线及其他仪器分析条件,在选定的仪器条件下,建立了电感耦合等离子体原子发射光谱法(ICP-AES)测定试液中镍、铜、铁、钴、锌、锑、硒7种杂质元素的分析方法。各元素工作曲线相关系数均大于0.999,同时对各元素进行了方法检出限、样品的精密度和加标回收试验,各元素的相对标准偏差为0.41%~8.57%,回收率为98.0%~106.9%,该方法简便、快速,可以满足含银铅铋合金锭中各杂质元素的测定要求。 展开更多
关键词 含银铅铋合金锭 电感耦合等离子体原子发射光谱法 杂质元素
下载PDF
ICP-AES测定稀土强化黑色二氧化钛中镧铈钇的方法研究
16
作者 陈小毅 王勇 +5 位作者 李子敬 孙浩 李国伟 张远琴 刘洪琼 吴立平 《科技资讯》 2024年第13期240-244,共5页
采用HF-HNO_(3)混合酸作为消解试剂,选择Y(360.073 nm)、La(408.672 nm)、Ce(413.380 nm)为分析线,建立了电感耦合等离子体原子发射光谱法测定稀土强化黑色二氧化钛中La、Ce、Y这3种稀土元素的方法。通过系列实验,探讨了样品消解条件、... 采用HF-HNO_(3)混合酸作为消解试剂,选择Y(360.073 nm)、La(408.672 nm)、Ce(413.380 nm)为分析线,建立了电感耦合等离子体原子发射光谱法测定稀土强化黑色二氧化钛中La、Ce、Y这3种稀土元素的方法。通过系列实验,探讨了样品消解条件、基体效应、共存元素干扰,分析谱线选择等对待测元素测定的影响。结果表明:当试样溶液中待测元素浓度低于5.0 mg/L时,基体钛对待测元素有影响,须采用基体匹配消除影响;共存元素干扰实验表明,当各共存元素溶液低于200 mg/L时,互不干扰测定。各元素方法检出限如下:La为0.0009%,Ce为0.0013%,Y为0.0004%,回收率为97.8%~102.6%,变异系数CV值为0.56%~3.19%;该方法用于测定稀土强化黑色二氧化钛中各稀土元素测定结果与理论值基本一致,测定结果准确可靠。 展开更多
关键词 电感耦合等离子体发射光谱法 稀土强化黑色二氧化钛
下载PDF
基于ICP-AES的岩石中锌元素含量分析与特征研究
17
作者 郭瑾 《世界有色金属》 2024年第17期196-198,共3页
锌作为地壳中常见的元素之一,其在地球科学中的分布和行为长期以来一直是研究的焦点。锌的地球化学特性使其在多种地质过程中扮演重要角色,同时也是许多生态系统和工业应用中的关键元素。随着分析技术的发展,ICP-AES已成为分析岩石中微... 锌作为地壳中常见的元素之一,其在地球科学中的分布和行为长期以来一直是研究的焦点。锌的地球化学特性使其在多种地质过程中扮演重要角色,同时也是许多生态系统和工业应用中的关键元素。随着分析技术的发展,ICP-AES已成为分析岩石中微量元素含量的主要方法之一。该技术以其高灵敏度、准确性和多元素分析能力,为研究岩石中锌元素含量提供了强有力的工具。本文利用ICP-AES技术系统地分析了不同类型岩石中的锌元素含量,并探讨其地质意义。 展开更多
关键词 电感耦合等离子体 原子发射光谱法 岩石 锌元素 含量 特征
下载PDF
ICP-AES法测定废电路板中铅锌镍和锡的方法探讨
18
作者 钱玲 《山西化工》 CAS 2024年第4期88-89,92,共3页
主要研究了适用于废电路板中铅、锌、镍和锡含量的测定方法。采用将废电路板样品进行破碎和风选,样品经制备后为金属和非金属两种材质,用盐酸和过氧化氢作为溶解剂,将待测组分全部溶解,酒石酸掩蔽干扰离子,在盐酸(10%)介质下利用电感耦... 主要研究了适用于废电路板中铅、锌、镍和锡含量的测定方法。采用将废电路板样品进行破碎和风选,样品经制备后为金属和非金属两种材质,用盐酸和过氧化氢作为溶解剂,将待测组分全部溶解,酒石酸掩蔽干扰离子,在盐酸(10%)介质下利用电感耦合等离子体原子发射光谱仪测定待测元素含量。该方法操作简便快捷,方法检出限满足最低浓度要求,测量范围广,准确度高,精密度好。试验样品加标回收率在89.7%~99.8%,相对标准偏差在0.47%~1.58%。 展开更多
关键词 电感耦合等离子体原子发射光谱法 废电路板 测定 方法探讨
下载PDF
探讨ICP-AES法在测定多金属矿石银铅锌含量中的应用
19
作者 田晓燕 《世界有色金属》 2024年第19期196-198,共3页
多金属矿石是工业和技术发展的重要资源,其中铜、铅、锌的含量对于矿石的价值和加工过程具有重要影响。传统的元素分析方法往往费时、复杂,难以应对复杂矿石样品的分析需求。感应耦合等离子体原子发射光谱法(ICP-AES)以其高灵敏度、快... 多金属矿石是工业和技术发展的重要资源,其中铜、铅、锌的含量对于矿石的价值和加工过程具有重要影响。传统的元素分析方法往往费时、复杂,难以应对复杂矿石样品的分析需求。感应耦合等离子体原子发射光谱法(ICP-AES)以其高灵敏度、快速响应和准确度高的特点,为多元素同时分析提供了有效手段。本文旨在探究ICP-AES在多金属矿石中铜、铅、锌含量测定中的应用效果,通过优化样品处理方法和分析流程,旨在提高分析的准确性和可靠性。 展开更多
关键词 电感耦合等离子体发射光谱法 多金属矿石 含量
下载PDF
ICP-AES法测定焊锡中金属银的研究分析
20
作者 何龙波 马萍 刘雅如 《广州化工》 CAS 2024年第8期29-30,59,共3页
本文综述了电感耦合等离子体-原子发射光谱法在测定焊锡中金属银元素的工作原理,文章从待测样品前处理方法、样品制备过程、实验条件、以及数据分析方法四个方面分析了影响电感耦合等离子体-原子发射光谱法检测结果准确度的因素,并提出... 本文综述了电感耦合等离子体-原子发射光谱法在测定焊锡中金属银元素的工作原理,文章从待测样品前处理方法、样品制备过程、实验条件、以及数据分析方法四个方面分析了影响电感耦合等离子体-原子发射光谱法检测结果准确度的因素,并提出了相应的提高准确度的改进措施,并在高级算法方面对电感耦合等离子体-原子发射光谱法测定焊锡中金属银的未来发展进行了展望。 展开更多
关键词 电感耦合等离子体-原子发射光谱法 焊锡 银元素 预测
下载PDF
上一页 1 2 108 下一页 到第
使用帮助 返回顶部