An improved analytical method to determine the content of 52 major, minor and trace elements in marine geological samples, using a HF-HCl-HNO_3 acid system with a high-pressure closed digestion method(HPCD), is stud...An improved analytical method to determine the content of 52 major, minor and trace elements in marine geological samples, using a HF-HCl-HNO_3 acid system with a high-pressure closed digestion method(HPCD), is studied by an inductively coupled plasma optical emission spectrometry(ICP-OES) and an inductively coupled plasma mass spectrometry(ICP-MS). The operating parameters of the instruments are optimized, and the optimal analytical parameters are determined. The influences of optical spectrum and mass spectrum interferences, digestion methods and acid systems on the analytical results are investigated. The optimal spectral lines and isotopes are chosen, and internal standard element of rhodium is selected to compensate for matrix effects and analytical signals drifting. Compared with the methods of an electric heating plate digestion and a microwave digestion, a high-pressure closed digestion method is optimized with less acid, complete digestion,less damage for digestion process. The marine geological samples are dissolved completely by a HF-HCl-HNO_3 system, the relative error(RE) for the analytical results are all less than 6.0%. The method detection limits are 2–40μg/g by the ICP-OES, and 6–80 ng/g by ICP-MS. The methods are used to determine the marine sediment reference materials(GBW07309, GBW07311, GBW07313), rock reference materials(GBW07103, GBW07104,GBW07105), and cobalt-rich crust reference materials(GBW07337, GBW07338, GBW07339), the obtained analytical results are in agreement with the certified values, and both of the relative standard deviation(RSD) and the relative error(RE) are less than 6.0%. The analytical method meets the requirements for determining 52 elements contents of bulk marine geological samples.展开更多
An experimental setup was built up to carry out radio frequency (RF) inductively coupled plasma (ICP) and dielectric barrier discharge (DBD), and to depict the optical emission spectra (OES) of the discharges. OES fro...An experimental setup was built up to carry out radio frequency (RF) inductively coupled plasma (ICP) and dielectric barrier discharge (DBD), and to depict the optical emission spectra (OES) of the discharges. OES from argon ICP and DBD plasmas in visible and near ultraviolet region were measured. For argon ICP, the higher RF power input (higher than 500 W for our machine), the higher degree of argon plasma ionization. But that doesn't mean a higher mean electron energy. With the increase in the power input, the mean electron energy increases slightly, whereas the density of electron increases apparently On the contrary, argon DBD discharge behaves in the manner of a pulsed DC discharge on optical emission spectroscopy and V-I characteristics. DBD current is composed of a series of pulses equally spaced in temporal domain. The Kinetics of DBD emission strength is mainly governed by the frequency of the current pulse.展开更多
Inductively coupled plasma optical emission spectrometric approach(1CP-OES) is used to determine the potassium content as principal component in pyrotechnic compositions used for fireworks and firecrackers. Element ...Inductively coupled plasma optical emission spectrometric approach(1CP-OES) is used to determine the potassium content as principal component in pyrotechnic compositions used for fireworks and firecrackers. Element of potassium is conunonly found in potassium nitrate and potassium perchlorate in pyrotechnic compositions in fireworks and firecrackers. Statistical analysis shows that potassium nitrate content in pyrotechnics is between 10% to 60% and the potassium perchlorate content is between 20% to 70%,which counted in the content of potassium element is between 4% to 23%. Concept of this method: considering the weight of the sample is 400rag,constant volume is 1L and the concentration of potassium is between 10 mg/L to 90 mg/L in sample solution, the determination scope of the method for the potassium content would be between 1% to 23%.Further experiments proved that the fitting correlation coefficient of potassium calibration curve is 0.9997 or higher, recovery is 89.15%-100.23%.The allowable differential value is 0.4% between two single tests under repeatable conditions. This method can completely satisfy the requirements of the fireworks and firecrackers industry with high accuracy and good precision.展开更多
Inductively coupled plasma optical emission spectrometric approach(ICP-OES)is used to determine the magnesium and aluminum content as principal components in pyrotechnic compositions used for fireworks and firecrack...Inductively coupled plasma optical emission spectrometric approach(ICP-OES)is used to determine the magnesium and aluminum content as principal components in pyrotechnic compositions used for fireworks and firecrackers. Elements of magnesium and aluminum are commonly found in aluminum powder or magnesium-aluminum alloy powder in pyrotechnic compositions in fireworks and firecrackers. Statistical analysis shows that the magnesium content in pyrotechnics is between 8% to 30% and the aluminum content is between 8% to 35%(roughly).Concept of this method: suppose the weight of the sample is 400rag,constant volume is IL and the concentlation of magnesium and aluminum is between 12mg/L to 160mg/L in sample solution, the determination scope of the method for magnesium and aluminum content would be between 3% to 40%.Further experiments proved that the fitting correlation coefficient of the magnesium calibration curve is 0.9999 or higher, recovery is 101.01% -101.96%.The fitting correlation coefficient of the aluminum calibration curve is 0.9999 or higher, recovery is 99.36%-103.07%. The allowable differential value is 0.4% between two single tests under repeatable conditions. This method can completely satisfy the requirements of the fireworks and firecrackers industry with high accuracy and good precision.展开更多
The ion line of 434.8 nm and atom line of 419.8 nm of Ar plasma produced by an inductively coupled plasma (ICP) were measured by optical emission spectroscopy and the influences from the working gas pressure, radio-...The ion line of 434.8 nm and atom line of 419.8 nm of Ar plasma produced by an inductively coupled plasma (ICP) were measured by optical emission spectroscopy and the influences from the working gas pressure, radio-frequency (RF) power and different positions in the discharge chamber on the line intensities were investigated in this study. It was found that the intensity of Ar atom line increased firstly and then saturated with the increase of the pressure. The line intensity of Ar^+, on the other hand, reached a maximum value and then decreased along with the pressure. The intensity of the line in an RF discharge also demonstrated a jumping mode and a hysteresis phenomenon with the RF power. When the RF power increased to 400 W, the discharge jumped from the E-mode to the H-mode where the line intensity of Ar atom demonstrated a sudden increase, while the intensity of Ar^+ ion only changed slightly. If the RF power decreased from a high value, e.g., 1000 W, the discharge would jump from the H-mode back to the E-mode at a power of 300 W. At this time the intensities of Ar and Ar^+ lines would also decrease sharply. It was also noticed in this paper that the intensity of the ion line depended on the detective location in the chamber, namely at the bottom of the chamber the line was more intense than that in the middle of the chamber, but less intense than at the top, which is considered to be related to the capacitance coupling ability of the ICP plasma in different discharge areas.展开更多
Dry etching of 6H silicon carbide (6H-SiC) wafers in a C4Fs/Ar dual-frequency capacitively coupled plasma (DF-CCP) was investigated. Atomic force microscopy (AFM) and X-ray photoelectron spectroscopy (XPS) wer...Dry etching of 6H silicon carbide (6H-SiC) wafers in a C4Fs/Ar dual-frequency capacitively coupled plasma (DF-CCP) was investigated. Atomic force microscopy (AFM) and X-ray photoelectron spectroscopy (XPS) were used to measure the SiC surface structure and compositions, respectively. Optical emission spectroscopy (OES) was used to measure the relative concentration of F radicals in the plasma. It was found that the roughness of the etched SiC surface and the etching rate are directly related to the power of low-frequency (LF) source. At lower LF power, a smaller surface roughness and a lower etching rate are obtained due to weak bombardment of low energy ions on the SiC wafers. At higher LF power the etching rate can be efficiently increased, but the surface roughness increases too. Compared with other plasma dry etching methods, the DF-CCP can effectively inhibit CχFγ films' deposition, and reduce surface residues.展开更多
Low pressure argon dual-frequency (DF) capacitively coupled plasma (CCP) is generated by using different frequency configurations, such as 13.56/2, 27/2, 41/2, and 60/2 MHz. Characteristics of the plasma are inves...Low pressure argon dual-frequency (DF) capacitively coupled plasma (CCP) is generated by using different frequency configurations, such as 13.56/2, 27/2, 41/2, and 60/2 MHz. Characteristics of the plasma are investigated by using a floating double electrical probe and optical emission spectroscopy (OES). It is shown that in the DF-CCPs, the electron temperature Te decreases with the increase in exciting frequency, while the onset of 2 MHz induces a sudden increase in Te and the electron density increases basically with the increase in low frequency (LF) power. The intensity of 750.4 nm emission line increases with the LF power in the case of 13.56/2 MHz, while different tendencies of line intensity with the LF power appear for other configurations. The reason for this is also discussed.展开更多
This paper proposes a simple collisional-radiative model to characterise capacitively coupled argon plasmas driven by conventional radio frequency in combination with optical emission spectroscopy and Langmuir probe m...This paper proposes a simple collisional-radiative model to characterise capacitively coupled argon plasmas driven by conventional radio frequency in combination with optical emission spectroscopy and Langmuir probe measurements. Two major processes are considered in this model, electron-impact excitation and the spontaneous radiative decay. The diffusion loss term, which is found to be important for the two metastable states (4s[3/2]2, 4s'[1/2]0), is also taken into account. Behaviours of representative metastable and radiative states are discussed. Two emission lines (located at 696.5 nm and 750.4 nm) are selected and intensities are measured to obtain populated densities of the corresponding radiative states in the argon plasma. The calculated results agree well with that measured by Langmuir probe, indicating that the current model combined with optical emission spectroscopy is a candidate tool for electron density and temperature measurement in radio frequency capacitively coupled discharges.展开更多
The phylogenetic relationship for classification traits and eight mineral elements in brown rice (Oryza sativa L.) from Yunnan Province in China was carried out using microwave assisted digestion followed by inducti...The phylogenetic relationship for classification traits and eight mineral elements in brown rice (Oryza sativa L.) from Yunnan Province in China was carried out using microwave assisted digestion followed by inductively coupled plasma atomic emission spectroscopy, and the analytical procedures were carefully controlled and validated. In general, the results show that the mean levels of K, Ca, Mg, Fe and Cu in brown rice for 789 accessions of rice landraces was distinctly lower than that of improved cultivars. They further demonstrate that Ca plays an important role in the differentiation of subspecies indica-japonica, especially to enhance adaptation of cold stress, and that five mineral elements in brown rice enhance the eurytopicity from landrace to improved cultivar. Hierarchical cluster analysis, using average linkage from SPSS software based on eight mineral elements in brown rice, showed that Yunnan rice could be grouped into rice landrace and improved cultivar, with the rice landrace being further clustered into five subgroups, and that, interestingly, purple rice does not cluster with either of the groups. Our present data confirm that indica is the closest relative of late rice and white rice, and that they constitute rice landraces together, whereas japonica is the closest relatives of non-nuda, early-mid and glutinous rice. It is further shown that japonica, non-nuda, early-mid, glutinous, white and red rice might be more primitive than indica, nuda, late, non-glutinous and purple rice, respectively.展开更多
[ Objective] To study the effects of different pretreatment methods on determination of microelement in feed and thus find the best pre treatment method for each microetement, t Method] The samples (concentrated feed...[ Objective] To study the effects of different pretreatment methods on determination of microelement in feed and thus find the best pre treatment method for each microetement, t Method] The samples (concentrated feeding stuff and fodder) were pretreated through throe methods, that is, dry incineration method, HNOs HCIO, wetdecomposition method and microwave digestion method. Then the content of seven kinds of mi croelement (AI, Ca, Cu, Fe, Mn, Se and Zn) was determined by inductively coupled plasma atomic emission spectrometer (ICPAES). I Result] These three methods were all suitable for the determination of Cu, Mn and Zn in concentrated feeding stuff and the determination of Cu and Ca in fodder. The content of Cu and Ca was higher in fodder detected by HNO3 HCIO, wetdecomposition method. The microwave digestion method was suitable for the determination of AI and Ca in concentrated feeding stuff and the determination of AI, Fe, Mn and Zn in fodder. The dry incinera tion method was fit for the determination of Fe in concentrated feeding stuff. [ Condusionl The content of different microelements should be deter mined after the feed is treated with different Ioretreatment methods.展开更多
In this work,we investigated the discharge characteristics and heating mechanisms of argon helicon plasma in different wave coupled modes with and without blue core.Spatially resolved spectroscopy and emission intensi...In this work,we investigated the discharge characteristics and heating mechanisms of argon helicon plasma in different wave coupled modes with and without blue core.Spatially resolved spectroscopy and emission intensity of argon atom and ion lines were measured via local optical emission spectroscopy,and electron density was measured experimentally by an RFcompensated Langmuir probe.The relation between the emission intensity and the electron density was obtained and the wavenumbers of helicon and’Trivelpiece-Gould’(TG)waves were calculated by solving the dispersion relation in wave modes.The results show that at least two distinct wave coupled modes appear in argon helicon plasma at increasing RF power,i.e.blue core(or BC)mode with a significant bright core of blue lights and a normal wave(NW)mode without blue core.The emission intensity of atom line 750.5 nm(lArⅠ750.5nm)is related to the electron density and tends to be saturated in wave coupled modes due to the neutral depletion,while the intensity of ion line 480.6 nm(IArⅡ480.6nm)is a function of the electron density and temperature,and increases dramatically as the RF power is increased.Theoretical analysis shows that TG waves are strongly damped at the plasma edge in NW and/or BC modes,while helicon waves are the dominant mechanism of power deposition or central heating of electrons in both modes.The formation of BC column mainly depends on the enhanced central electron heating by helicon waves rather than TG waves since the excitation of TG waves would be suppressed in this special anti-resonance region.展开更多
Laser induced breakdown Spectroscopy(LIBS)was applied for the elemental analysis and exposure of the heavy metals in betel leaves in air.Pulsed Nd∶YAG(1064 nm)in conjunction with a suitable detector(LIBS 2000+,Ocean ...Laser induced breakdown Spectroscopy(LIBS)was applied for the elemental analysis and exposure of the heavy metals in betel leaves in air.Pulsed Nd∶YAG(1064 nm)in conjunction with a suitable detector(LIBS 2000+,Ocean Optics,Inc)having the optical resolution of 0.06 nm was used to record the emission spectra from 220 to 720 nm.Elements like Al,Ba,Ca,Cr,Cu,P,Fe,K,Mg,Mn,Na,P,S,Sr,and Zn were found to present in the samples.The relative abundances of the observed elements were calculated through standard calibration curve method,integrated intensity ratio method,and weight percentage LIBS approach.LIBS findings were validated by comparing its results with the results obtained using a typical analytical technique of Inductively Coupled plasma-optical emission spectroscopy(ICP-OES).Limit of detection(LOD)of the LIBS system was also estimated for heavy metals.The experience gain through this work implies that LIBS could be highly applicable for testing the quality and purity of food products.展开更多
基金The China Ocean Mineral Resources Research and Development Association Research Program of the State Oceanic Administration of China under contract No.DY125-13-R-07the National Natural Science Foundation of China under contract Nos 41322036 and 41230960+1 种基金the Shandong Provincial Natural Science Foundation of China under contract No.ZR2014DP009the Special Basic Research Funds for Central Public Research Institutes for The First Institute of Oceanography,State Oceanic Administration of China under contract Nos GY0213G06 and GY02-2012G35
文摘An improved analytical method to determine the content of 52 major, minor and trace elements in marine geological samples, using a HF-HCl-HNO_3 acid system with a high-pressure closed digestion method(HPCD), is studied by an inductively coupled plasma optical emission spectrometry(ICP-OES) and an inductively coupled plasma mass spectrometry(ICP-MS). The operating parameters of the instruments are optimized, and the optimal analytical parameters are determined. The influences of optical spectrum and mass spectrum interferences, digestion methods and acid systems on the analytical results are investigated. The optimal spectral lines and isotopes are chosen, and internal standard element of rhodium is selected to compensate for matrix effects and analytical signals drifting. Compared with the methods of an electric heating plate digestion and a microwave digestion, a high-pressure closed digestion method is optimized with less acid, complete digestion,less damage for digestion process. The marine geological samples are dissolved completely by a HF-HCl-HNO_3 system, the relative error(RE) for the analytical results are all less than 6.0%. The method detection limits are 2–40μg/g by the ICP-OES, and 6–80 ng/g by ICP-MS. The methods are used to determine the marine sediment reference materials(GBW07309, GBW07311, GBW07313), rock reference materials(GBW07103, GBW07104,GBW07105), and cobalt-rich crust reference materials(GBW07337, GBW07338, GBW07339), the obtained analytical results are in agreement with the certified values, and both of the relative standard deviation(RSD) and the relative error(RE) are less than 6.0%. The analytical method meets the requirements for determining 52 elements contents of bulk marine geological samples.
基金This work is supported by the National Science Foundation of China No.19835030.
文摘An experimental setup was built up to carry out radio frequency (RF) inductively coupled plasma (ICP) and dielectric barrier discharge (DBD), and to depict the optical emission spectra (OES) of the discharges. OES from argon ICP and DBD plasmas in visible and near ultraviolet region were measured. For argon ICP, the higher RF power input (higher than 500 W for our machine), the higher degree of argon plasma ionization. But that doesn't mean a higher mean electron energy. With the increase in the power input, the mean electron energy increases slightly, whereas the density of electron increases apparently On the contrary, argon DBD discharge behaves in the manner of a pulsed DC discharge on optical emission spectroscopy and V-I characteristics. DBD current is composed of a series of pulses equally spaced in temporal domain. The Kinetics of DBD emission strength is mainly governed by the frequency of the current pulse.
文摘Inductively coupled plasma optical emission spectrometric approach(1CP-OES) is used to determine the potassium content as principal component in pyrotechnic compositions used for fireworks and firecrackers. Element of potassium is conunonly found in potassium nitrate and potassium perchlorate in pyrotechnic compositions in fireworks and firecrackers. Statistical analysis shows that potassium nitrate content in pyrotechnics is between 10% to 60% and the potassium perchlorate content is between 20% to 70%,which counted in the content of potassium element is between 4% to 23%. Concept of this method: considering the weight of the sample is 400rag,constant volume is 1L and the concentration of potassium is between 10 mg/L to 90 mg/L in sample solution, the determination scope of the method for the potassium content would be between 1% to 23%.Further experiments proved that the fitting correlation coefficient of potassium calibration curve is 0.9997 or higher, recovery is 89.15%-100.23%.The allowable differential value is 0.4% between two single tests under repeatable conditions. This method can completely satisfy the requirements of the fireworks and firecrackers industry with high accuracy and good precision.
文摘Inductively coupled plasma optical emission spectrometric approach(ICP-OES)is used to determine the magnesium and aluminum content as principal components in pyrotechnic compositions used for fireworks and firecrackers. Elements of magnesium and aluminum are commonly found in aluminum powder or magnesium-aluminum alloy powder in pyrotechnic compositions in fireworks and firecrackers. Statistical analysis shows that the magnesium content in pyrotechnics is between 8% to 30% and the aluminum content is between 8% to 35%(roughly).Concept of this method: suppose the weight of the sample is 400rag,constant volume is IL and the concentlation of magnesium and aluminum is between 12mg/L to 160mg/L in sample solution, the determination scope of the method for magnesium and aluminum content would be between 3% to 40%.Further experiments proved that the fitting correlation coefficient of the magnesium calibration curve is 0.9999 or higher, recovery is 101.01% -101.96%.The fitting correlation coefficient of the aluminum calibration curve is 0.9999 or higher, recovery is 99.36%-103.07%. The allowable differential value is 0.4% between two single tests under repeatable conditions. This method can completely satisfy the requirements of the fireworks and firecrackers industry with high accuracy and good precision.
基金supported by National Natural Science Foundation of China (Nos.50277003,10505005)
文摘The ion line of 434.8 nm and atom line of 419.8 nm of Ar plasma produced by an inductively coupled plasma (ICP) were measured by optical emission spectroscopy and the influences from the working gas pressure, radio-frequency (RF) power and different positions in the discharge chamber on the line intensities were investigated in this study. It was found that the intensity of Ar atom line increased firstly and then saturated with the increase of the pressure. The line intensity of Ar^+, on the other hand, reached a maximum value and then decreased along with the pressure. The intensity of the line in an RF discharge also demonstrated a jumping mode and a hysteresis phenomenon with the RF power. When the RF power increased to 400 W, the discharge jumped from the E-mode to the H-mode where the line intensity of Ar atom demonstrated a sudden increase, while the intensity of Ar^+ ion only changed slightly. If the RF power decreased from a high value, e.g., 1000 W, the discharge would jump from the H-mode back to the E-mode at a power of 300 W. At this time the intensities of Ar and Ar^+ lines would also decrease sharply. It was also noticed in this paper that the intensity of the ion line depended on the detective location in the chamber, namely at the bottom of the chamber the line was more intense than that in the middle of the chamber, but less intense than at the top, which is considered to be related to the capacitance coupling ability of the ICP plasma in different discharge areas.
基金supported by National Natural Science Foundation of China (Nos. 10975105, 11275136, 10975106, 11175126, 11204266 and 11075114) the National Magnetic Confinement Fusion Science Program of China (Nos. 2010GB106000, 2010GB106009), the Open Project of State Key Laboratory of Functional Materials for Information and Qing Lan Project, a Project Funded by the Priority Academic Program Development of Jiangsu Higher Education Institutions and the Program for graduates Research & Innovation in University of Jiangsu Province, China (No. CX10B-031Z)
文摘Dry etching of 6H silicon carbide (6H-SiC) wafers in a C4Fs/Ar dual-frequency capacitively coupled plasma (DF-CCP) was investigated. Atomic force microscopy (AFM) and X-ray photoelectron spectroscopy (XPS) were used to measure the SiC surface structure and compositions, respectively. Optical emission spectroscopy (OES) was used to measure the relative concentration of F radicals in the plasma. It was found that the roughness of the etched SiC surface and the etching rate are directly related to the power of low-frequency (LF) source. At lower LF power, a smaller surface roughness and a lower etching rate are obtained due to weak bombardment of low energy ions on the SiC wafers. At higher LF power the etching rate can be efficiently increased, but the surface roughness increases too. Compared with other plasma dry etching methods, the DF-CCP can effectively inhibit CχFγ films' deposition, and reduce surface residues.
基金supported by National Natural Science Foundation of China (Nos. 10635010, 10775103)
文摘Low pressure argon dual-frequency (DF) capacitively coupled plasma (CCP) is generated by using different frequency configurations, such as 13.56/2, 27/2, 41/2, and 60/2 MHz. Characteristics of the plasma are investigated by using a floating double electrical probe and optical emission spectroscopy (OES). It is shown that in the DF-CCPs, the electron temperature Te decreases with the increase in exciting frequency, while the onset of 2 MHz induces a sudden increase in Te and the electron density increases basically with the increase in low frequency (LF) power. The intensity of 750.4 nm emission line increases with the LF power in the case of 13.56/2 MHz, while different tendencies of line intensity with the LF power appear for other configurations. The reason for this is also discussed.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.10635010 and 10775103)
文摘This paper proposes a simple collisional-radiative model to characterise capacitively coupled argon plasmas driven by conventional radio frequency in combination with optical emission spectroscopy and Langmuir probe measurements. Two major processes are considered in this model, electron-impact excitation and the spontaneous radiative decay. The diffusion loss term, which is found to be important for the two metastable states (4s[3/2]2, 4s'[1/2]0), is also taken into account. Behaviours of representative metastable and radiative states are discussed. Two emission lines (located at 696.5 nm and 750.4 nm) are selected and intensities are measured to obtain populated densities of the corresponding radiative states in the argon plasma. The calculated results agree well with that measured by Langmuir probe, indicating that the current model combined with optical emission spectroscopy is a candidate tool for electron density and temperature measurement in radio frequency capacitively coupled discharges.
基金Supported by the National Natural Science Foundation of China (30660092)the Cooperation Program between Province and Zhejiang University from Yunnan Provincial Scientific and Technology Department (2006YX12)the Yunnan Introduction and Foster Talent Program (2005PY01-14)
文摘The phylogenetic relationship for classification traits and eight mineral elements in brown rice (Oryza sativa L.) from Yunnan Province in China was carried out using microwave assisted digestion followed by inductively coupled plasma atomic emission spectroscopy, and the analytical procedures were carefully controlled and validated. In general, the results show that the mean levels of K, Ca, Mg, Fe and Cu in brown rice for 789 accessions of rice landraces was distinctly lower than that of improved cultivars. They further demonstrate that Ca plays an important role in the differentiation of subspecies indica-japonica, especially to enhance adaptation of cold stress, and that five mineral elements in brown rice enhance the eurytopicity from landrace to improved cultivar. Hierarchical cluster analysis, using average linkage from SPSS software based on eight mineral elements in brown rice, showed that Yunnan rice could be grouped into rice landrace and improved cultivar, with the rice landrace being further clustered into five subgroups, and that, interestingly, purple rice does not cluster with either of the groups. Our present data confirm that indica is the closest relative of late rice and white rice, and that they constitute rice landraces together, whereas japonica is the closest relatives of non-nuda, early-mid and glutinous rice. It is further shown that japonica, non-nuda, early-mid, glutinous, white and red rice might be more primitive than indica, nuda, late, non-glutinous and purple rice, respectively.
文摘[ Objective] To study the effects of different pretreatment methods on determination of microelement in feed and thus find the best pre treatment method for each microetement, t Method] The samples (concentrated feeding stuff and fodder) were pretreated through throe methods, that is, dry incineration method, HNOs HCIO, wetdecomposition method and microwave digestion method. Then the content of seven kinds of mi croelement (AI, Ca, Cu, Fe, Mn, Se and Zn) was determined by inductively coupled plasma atomic emission spectrometer (ICPAES). I Result] These three methods were all suitable for the determination of Cu, Mn and Zn in concentrated feeding stuff and the determination of Cu and Ca in fodder. The content of Cu and Ca was higher in fodder detected by HNO3 HCIO, wetdecomposition method. The microwave digestion method was suitable for the determination of AI and Ca in concentrated feeding stuff and the determination of AI, Fe, Mn and Zn in fodder. The dry incinera tion method was fit for the determination of Fe in concentrated feeding stuff. [ Condusionl The content of different microelements should be deter mined after the feed is treated with different Ioretreatment methods.
基金National Natural Science Foundation of China(No.11975047)。
文摘In this work,we investigated the discharge characteristics and heating mechanisms of argon helicon plasma in different wave coupled modes with and without blue core.Spatially resolved spectroscopy and emission intensity of argon atom and ion lines were measured via local optical emission spectroscopy,and electron density was measured experimentally by an RFcompensated Langmuir probe.The relation between the emission intensity and the electron density was obtained and the wavenumbers of helicon and’Trivelpiece-Gould’(TG)waves were calculated by solving the dispersion relation in wave modes.The results show that at least two distinct wave coupled modes appear in argon helicon plasma at increasing RF power,i.e.blue core(or BC)mode with a significant bright core of blue lights and a normal wave(NW)mode without blue core.The emission intensity of atom line 750.5 nm(lArⅠ750.5nm)is related to the electron density and tends to be saturated in wave coupled modes due to the neutral depletion,while the intensity of ion line 480.6 nm(IArⅡ480.6nm)is a function of the electron density and temperature,and increases dramatically as the RF power is increased.Theoretical analysis shows that TG waves are strongly damped at the plasma edge in NW and/or BC modes,while helicon waves are the dominant mechanism of power deposition or central heating of electrons in both modes.The formation of BC column mainly depends on the enhanced central electron heating by helicon waves rather than TG waves since the excitation of TG waves would be suppressed in this special anti-resonance region.
文摘Laser induced breakdown Spectroscopy(LIBS)was applied for the elemental analysis and exposure of the heavy metals in betel leaves in air.Pulsed Nd∶YAG(1064 nm)in conjunction with a suitable detector(LIBS 2000+,Ocean Optics,Inc)having the optical resolution of 0.06 nm was used to record the emission spectra from 220 to 720 nm.Elements like Al,Ba,Ca,Cr,Cu,P,Fe,K,Mg,Mn,Na,P,S,Sr,and Zn were found to present in the samples.The relative abundances of the observed elements were calculated through standard calibration curve method,integrated intensity ratio method,and weight percentage LIBS approach.LIBS findings were validated by comparing its results with the results obtained using a typical analytical technique of Inductively Coupled plasma-optical emission spectroscopy(ICP-OES).Limit of detection(LOD)of the LIBS system was also estimated for heavy metals.The experience gain through this work implies that LIBS could be highly applicable for testing the quality and purity of food products.