An improved analytical method to determine the content of 52 major, minor and trace elements in marine geological samples, using a HF-HCl-HNO_3 acid system with a high-pressure closed digestion method(HPCD), is stud...An improved analytical method to determine the content of 52 major, minor and trace elements in marine geological samples, using a HF-HCl-HNO_3 acid system with a high-pressure closed digestion method(HPCD), is studied by an inductively coupled plasma optical emission spectrometry(ICP-OES) and an inductively coupled plasma mass spectrometry(ICP-MS). The operating parameters of the instruments are optimized, and the optimal analytical parameters are determined. The influences of optical spectrum and mass spectrum interferences, digestion methods and acid systems on the analytical results are investigated. The optimal spectral lines and isotopes are chosen, and internal standard element of rhodium is selected to compensate for matrix effects and analytical signals drifting. Compared with the methods of an electric heating plate digestion and a microwave digestion, a high-pressure closed digestion method is optimized with less acid, complete digestion,less damage for digestion process. The marine geological samples are dissolved completely by a HF-HCl-HNO_3 system, the relative error(RE) for the analytical results are all less than 6.0%. The method detection limits are 2–40μg/g by the ICP-OES, and 6–80 ng/g by ICP-MS. The methods are used to determine the marine sediment reference materials(GBW07309, GBW07311, GBW07313), rock reference materials(GBW07103, GBW07104,GBW07105), and cobalt-rich crust reference materials(GBW07337, GBW07338, GBW07339), the obtained analytical results are in agreement with the certified values, and both of the relative standard deviation(RSD) and the relative error(RE) are less than 6.0%. The analytical method meets the requirements for determining 52 elements contents of bulk marine geological samples.展开更多
A An analytical method using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) for rapid simultaneous determination of 24 elements (Be, Mg, A1, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Ge, As, Se, ...A An analytical method using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) for rapid simultaneous determination of 24 elements (Be, Mg, A1, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Ge, As, Se, Mo, Ag, Cd, Sn Sb, Ba, Pt, Au, and Pb) in high purity cobalt was described. Sample digestions were performed in closed microwave vessels using HNO3 and HCI. The matrix effects because of the presence of excess HCI and Co were evaluated. The usefulness of high mass resolution for overcoming some spectral interference was demonstrated. The optimum conditions for the determination were tested and discussed. The standard addition method was employed for quantitative analysis. The detection limits were 0.016-1.50 ].tg·g^-1, the recovery ratios were 92.2%-111.2%, and the RSD was less than 3.6%. The method was accurate, quick, and convenient. It was applied to the determination of trace impurities in high purity cobalt with satisfactory results.展开更多
[ Objective] To study the effects of different pretreatment methods on determination of microelement in feed and thus find the best pre treatment method for each microetement, t Method] The samples (concentrated feed...[ Objective] To study the effects of different pretreatment methods on determination of microelement in feed and thus find the best pre treatment method for each microetement, t Method] The samples (concentrated feeding stuff and fodder) were pretreated through throe methods, that is, dry incineration method, HNOs HCIO, wetdecomposition method and microwave digestion method. Then the content of seven kinds of mi croelement (AI, Ca, Cu, Fe, Mn, Se and Zn) was determined by inductively coupled plasma atomic emission spectrometer (ICPAES). I Result] These three methods were all suitable for the determination of Cu, Mn and Zn in concentrated feeding stuff and the determination of Cu and Ca in fodder. The content of Cu and Ca was higher in fodder detected by HNO3 HCIO, wetdecomposition method. The microwave digestion method was suitable for the determination of AI and Ca in concentrated feeding stuff and the determination of AI, Fe, Mn and Zn in fodder. The dry incinera tion method was fit for the determination of Fe in concentrated feeding stuff. [ Condusionl The content of different microelements should be deter mined after the feed is treated with different Ioretreatment methods.展开更多
基金The China Ocean Mineral Resources Research and Development Association Research Program of the State Oceanic Administration of China under contract No.DY125-13-R-07the National Natural Science Foundation of China under contract Nos 41322036 and 41230960+1 种基金the Shandong Provincial Natural Science Foundation of China under contract No.ZR2014DP009the Special Basic Research Funds for Central Public Research Institutes for The First Institute of Oceanography,State Oceanic Administration of China under contract Nos GY0213G06 and GY02-2012G35
文摘An improved analytical method to determine the content of 52 major, minor and trace elements in marine geological samples, using a HF-HCl-HNO_3 acid system with a high-pressure closed digestion method(HPCD), is studied by an inductively coupled plasma optical emission spectrometry(ICP-OES) and an inductively coupled plasma mass spectrometry(ICP-MS). The operating parameters of the instruments are optimized, and the optimal analytical parameters are determined. The influences of optical spectrum and mass spectrum interferences, digestion methods and acid systems on the analytical results are investigated. The optimal spectral lines and isotopes are chosen, and internal standard element of rhodium is selected to compensate for matrix effects and analytical signals drifting. Compared with the methods of an electric heating plate digestion and a microwave digestion, a high-pressure closed digestion method is optimized with less acid, complete digestion,less damage for digestion process. The marine geological samples are dissolved completely by a HF-HCl-HNO_3 system, the relative error(RE) for the analytical results are all less than 6.0%. The method detection limits are 2–40μg/g by the ICP-OES, and 6–80 ng/g by ICP-MS. The methods are used to determine the marine sediment reference materials(GBW07309, GBW07311, GBW07313), rock reference materials(GBW07103, GBW07104,GBW07105), and cobalt-rich crust reference materials(GBW07337, GBW07338, GBW07339), the obtained analytical results are in agreement with the certified values, and both of the relative standard deviation(RSD) and the relative error(RE) are less than 6.0%. The analytical method meets the requirements for determining 52 elements contents of bulk marine geological samples.
基金the Natural Science Foundation of Hunan Province, China (No. 05JJ40017).
文摘A An analytical method using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) for rapid simultaneous determination of 24 elements (Be, Mg, A1, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Ge, As, Se, Mo, Ag, Cd, Sn Sb, Ba, Pt, Au, and Pb) in high purity cobalt was described. Sample digestions were performed in closed microwave vessels using HNO3 and HCI. The matrix effects because of the presence of excess HCI and Co were evaluated. The usefulness of high mass resolution for overcoming some spectral interference was demonstrated. The optimum conditions for the determination were tested and discussed. The standard addition method was employed for quantitative analysis. The detection limits were 0.016-1.50 ].tg·g^-1, the recovery ratios were 92.2%-111.2%, and the RSD was less than 3.6%. The method was accurate, quick, and convenient. It was applied to the determination of trace impurities in high purity cobalt with satisfactory results.
文摘[ Objective] To study the effects of different pretreatment methods on determination of microelement in feed and thus find the best pre treatment method for each microetement, t Method] The samples (concentrated feeding stuff and fodder) were pretreated through throe methods, that is, dry incineration method, HNOs HCIO, wetdecomposition method and microwave digestion method. Then the content of seven kinds of mi croelement (AI, Ca, Cu, Fe, Mn, Se and Zn) was determined by inductively coupled plasma atomic emission spectrometer (ICPAES). I Result] These three methods were all suitable for the determination of Cu, Mn and Zn in concentrated feeding stuff and the determination of Cu and Ca in fodder. The content of Cu and Ca was higher in fodder detected by HNO3 HCIO, wetdecomposition method. The microwave digestion method was suitable for the determination of AI and Ca in concentrated feeding stuff and the determination of AI, Fe, Mn and Zn in fodder. The dry incinera tion method was fit for the determination of Fe in concentrated feeding stuff. [ Condusionl The content of different microelements should be deter mined after the feed is treated with different Ioretreatment methods.