Inductively coupled plasma optical emission spectrometric approach(1CP-OES) is used to determine the potassium content as principal component in pyrotechnic compositions used for fireworks and firecrackers. Element ...Inductively coupled plasma optical emission spectrometric approach(1CP-OES) is used to determine the potassium content as principal component in pyrotechnic compositions used for fireworks and firecrackers. Element of potassium is conunonly found in potassium nitrate and potassium perchlorate in pyrotechnic compositions in fireworks and firecrackers. Statistical analysis shows that potassium nitrate content in pyrotechnics is between 10% to 60% and the potassium perchlorate content is between 20% to 70%,which counted in the content of potassium element is between 4% to 23%. Concept of this method: considering the weight of the sample is 400rag,constant volume is 1L and the concentration of potassium is between 10 mg/L to 90 mg/L in sample solution, the determination scope of the method for the potassium content would be between 1% to 23%.Further experiments proved that the fitting correlation coefficient of potassium calibration curve is 0.9997 or higher, recovery is 89.15%-100.23%.The allowable differential value is 0.4% between two single tests under repeatable conditions. This method can completely satisfy the requirements of the fireworks and firecrackers industry with high accuracy and good precision.展开更多
Inductively coupled plasma optical emission spectrometric approach(ICP-OES)is used to determine the magnesium and aluminum content as principal components in pyrotechnic compositions used for fireworks and firecrack...Inductively coupled plasma optical emission spectrometric approach(ICP-OES)is used to determine the magnesium and aluminum content as principal components in pyrotechnic compositions used for fireworks and firecrackers. Elements of magnesium and aluminum are commonly found in aluminum powder or magnesium-aluminum alloy powder in pyrotechnic compositions in fireworks and firecrackers. Statistical analysis shows that the magnesium content in pyrotechnics is between 8% to 30% and the aluminum content is between 8% to 35%(roughly).Concept of this method: suppose the weight of the sample is 400rag,constant volume is IL and the concentlation of magnesium and aluminum is between 12mg/L to 160mg/L in sample solution, the determination scope of the method for magnesium and aluminum content would be between 3% to 40%.Further experiments proved that the fitting correlation coefficient of the magnesium calibration curve is 0.9999 or higher, recovery is 101.01% -101.96%.The fitting correlation coefficient of the aluminum calibration curve is 0.9999 or higher, recovery is 99.36%-103.07%. The allowable differential value is 0.4% between two single tests under repeatable conditions. This method can completely satisfy the requirements of the fireworks and firecrackers industry with high accuracy and good precision.展开更多
A method based on the combination of coprecipitation with inductively coupledplasma atomic emission spectrometry (ICP-AES) was developed for the determination of impurities inhigh-purity sodium tungstate. Six elements...A method based on the combination of coprecipitation with inductively coupledplasma atomic emission spectrometry (ICP-AES) was developed for the determination of impurities inhigh-purity sodium tungstate. Six elements (Co, Cu, Fe, Mn, Ni, and Pb) were coprecipitated bylanthanum hydroxide so as to be concentrated and separated from the tungsten matrix. Effects of somefactors on the recoveries of the analytes and on the residual amount of sodium tungstate wereinvestigated, and the optimum conditions for the coprecipitation were proposed. Matrix-matchingcalibration curve method was used for the analysis. It is shown that the elements mentioned abovecan be quantitatively recovered. The detection limits for Co, Cu, Fe, Mn, Ni, and Pb are 0.07, 0.4,0.2, 0.1, 0.6, and 1.3 μg·g^(-1), respectively. The recoveries vary from 92.5% to 108%, and therelative standard deviations (RSDs) are in the range of 3.1%-5.5%.展开更多
An improved analytical method to determine the content of 52 major, minor and trace elements in marine geological samples, using a HF-HCl-HNO_3 acid system with a high-pressure closed digestion method(HPCD), is stud...An improved analytical method to determine the content of 52 major, minor and trace elements in marine geological samples, using a HF-HCl-HNO_3 acid system with a high-pressure closed digestion method(HPCD), is studied by an inductively coupled plasma optical emission spectrometry(ICP-OES) and an inductively coupled plasma mass spectrometry(ICP-MS). The operating parameters of the instruments are optimized, and the optimal analytical parameters are determined. The influences of optical spectrum and mass spectrum interferences, digestion methods and acid systems on the analytical results are investigated. The optimal spectral lines and isotopes are chosen, and internal standard element of rhodium is selected to compensate for matrix effects and analytical signals drifting. Compared with the methods of an electric heating plate digestion and a microwave digestion, a high-pressure closed digestion method is optimized with less acid, complete digestion,less damage for digestion process. The marine geological samples are dissolved completely by a HF-HCl-HNO_3 system, the relative error(RE) for the analytical results are all less than 6.0%. The method detection limits are 2–40μg/g by the ICP-OES, and 6–80 ng/g by ICP-MS. The methods are used to determine the marine sediment reference materials(GBW07309, GBW07311, GBW07313), rock reference materials(GBW07103, GBW07104,GBW07105), and cobalt-rich crust reference materials(GBW07337, GBW07338, GBW07339), the obtained analytical results are in agreement with the certified values, and both of the relative standard deviation(RSD) and the relative error(RE) are less than 6.0%. The analytical method meets the requirements for determining 52 elements contents of bulk marine geological samples.展开更多
A Kalman filter was developed for correction of wing interference in ICP-AES.Modeling wing interference theoretically instead of experimentally, the filter can compensate the shift in wavelength position in scans, and...A Kalman filter was developed for correction of wing interference in ICP-AES.Modeling wing interference theoretically instead of experimentally, the filter can compensate the shift in wavelength position in scans, and therefore reduce the effect of the interference on detection limit.展开更多
The development of laser sampling for optical emission spectrometry is reviewed . Advantages and limitations of pulsed laser sampling are compared with those of continuous laser sampling . A novel method of laser samp...The development of laser sampling for optical emission spectrometry is reviewed . Advantages and limitations of pulsed laser sampling are compared with those of continuous laser sampling . A novel method of laser sampling of liquid samples for inductively coupled plasma -atomic emission spectrometry has been proposed , and its analytical performance investigated.Experimental results showed that,as a method of sample introduction , laser vaporization of liquid samples enjoyed certain advantages , e.g.,much higher sensitivity, much lower detection limit and reduced sample volume , over solution nebulization . A perspective of the application of laser sampling-inductively coupled plasma - actomic emission spectrometry for rock and mineral analysis is estimated as well.展开更多
文摘Inductively coupled plasma optical emission spectrometric approach(1CP-OES) is used to determine the potassium content as principal component in pyrotechnic compositions used for fireworks and firecrackers. Element of potassium is conunonly found in potassium nitrate and potassium perchlorate in pyrotechnic compositions in fireworks and firecrackers. Statistical analysis shows that potassium nitrate content in pyrotechnics is between 10% to 60% and the potassium perchlorate content is between 20% to 70%,which counted in the content of potassium element is between 4% to 23%. Concept of this method: considering the weight of the sample is 400rag,constant volume is 1L and the concentration of potassium is between 10 mg/L to 90 mg/L in sample solution, the determination scope of the method for the potassium content would be between 1% to 23%.Further experiments proved that the fitting correlation coefficient of potassium calibration curve is 0.9997 or higher, recovery is 89.15%-100.23%.The allowable differential value is 0.4% between two single tests under repeatable conditions. This method can completely satisfy the requirements of the fireworks and firecrackers industry with high accuracy and good precision.
文摘Inductively coupled plasma optical emission spectrometric approach(ICP-OES)is used to determine the magnesium and aluminum content as principal components in pyrotechnic compositions used for fireworks and firecrackers. Elements of magnesium and aluminum are commonly found in aluminum powder or magnesium-aluminum alloy powder in pyrotechnic compositions in fireworks and firecrackers. Statistical analysis shows that the magnesium content in pyrotechnics is between 8% to 30% and the aluminum content is between 8% to 35%(roughly).Concept of this method: suppose the weight of the sample is 400rag,constant volume is IL and the concentlation of magnesium and aluminum is between 12mg/L to 160mg/L in sample solution, the determination scope of the method for magnesium and aluminum content would be between 3% to 40%.Further experiments proved that the fitting correlation coefficient of the magnesium calibration curve is 0.9999 or higher, recovery is 101.01% -101.96%.The fitting correlation coefficient of the aluminum calibration curve is 0.9999 or higher, recovery is 99.36%-103.07%. The allowable differential value is 0.4% between two single tests under repeatable conditions. This method can completely satisfy the requirements of the fireworks and firecrackers industry with high accuracy and good precision.
文摘A method based on the combination of coprecipitation with inductively coupledplasma atomic emission spectrometry (ICP-AES) was developed for the determination of impurities inhigh-purity sodium tungstate. Six elements (Co, Cu, Fe, Mn, Ni, and Pb) were coprecipitated bylanthanum hydroxide so as to be concentrated and separated from the tungsten matrix. Effects of somefactors on the recoveries of the analytes and on the residual amount of sodium tungstate wereinvestigated, and the optimum conditions for the coprecipitation were proposed. Matrix-matchingcalibration curve method was used for the analysis. It is shown that the elements mentioned abovecan be quantitatively recovered. The detection limits for Co, Cu, Fe, Mn, Ni, and Pb are 0.07, 0.4,0.2, 0.1, 0.6, and 1.3 μg·g^(-1), respectively. The recoveries vary from 92.5% to 108%, and therelative standard deviations (RSDs) are in the range of 3.1%-5.5%.
基金The China Ocean Mineral Resources Research and Development Association Research Program of the State Oceanic Administration of China under contract No.DY125-13-R-07the National Natural Science Foundation of China under contract Nos 41322036 and 41230960+1 种基金the Shandong Provincial Natural Science Foundation of China under contract No.ZR2014DP009the Special Basic Research Funds for Central Public Research Institutes for The First Institute of Oceanography,State Oceanic Administration of China under contract Nos GY0213G06 and GY02-2012G35
文摘An improved analytical method to determine the content of 52 major, minor and trace elements in marine geological samples, using a HF-HCl-HNO_3 acid system with a high-pressure closed digestion method(HPCD), is studied by an inductively coupled plasma optical emission spectrometry(ICP-OES) and an inductively coupled plasma mass spectrometry(ICP-MS). The operating parameters of the instruments are optimized, and the optimal analytical parameters are determined. The influences of optical spectrum and mass spectrum interferences, digestion methods and acid systems on the analytical results are investigated. The optimal spectral lines and isotopes are chosen, and internal standard element of rhodium is selected to compensate for matrix effects and analytical signals drifting. Compared with the methods of an electric heating plate digestion and a microwave digestion, a high-pressure closed digestion method is optimized with less acid, complete digestion,less damage for digestion process. The marine geological samples are dissolved completely by a HF-HCl-HNO_3 system, the relative error(RE) for the analytical results are all less than 6.0%. The method detection limits are 2–40μg/g by the ICP-OES, and 6–80 ng/g by ICP-MS. The methods are used to determine the marine sediment reference materials(GBW07309, GBW07311, GBW07313), rock reference materials(GBW07103, GBW07104,GBW07105), and cobalt-rich crust reference materials(GBW07337, GBW07338, GBW07339), the obtained analytical results are in agreement with the certified values, and both of the relative standard deviation(RSD) and the relative error(RE) are less than 6.0%. The analytical method meets the requirements for determining 52 elements contents of bulk marine geological samples.
文摘A Kalman filter was developed for correction of wing interference in ICP-AES.Modeling wing interference theoretically instead of experimentally, the filter can compensate the shift in wavelength position in scans, and therefore reduce the effect of the interference on detection limit.
文摘The development of laser sampling for optical emission spectrometry is reviewed . Advantages and limitations of pulsed laser sampling are compared with those of continuous laser sampling . A novel method of laser sampling of liquid samples for inductively coupled plasma -atomic emission spectrometry has been proposed , and its analytical performance investigated.Experimental results showed that,as a method of sample introduction , laser vaporization of liquid samples enjoyed certain advantages , e.g.,much higher sensitivity, much lower detection limit and reduced sample volume , over solution nebulization . A perspective of the application of laser sampling-inductively coupled plasma - actomic emission spectrometry for rock and mineral analysis is estimated as well.