This study explores the potentials of employing an Organic Rankine Cycle (ORC) system with variable inlet guide vanes (VIV) turbine geometry designed on a GT-Suite platform for effective exhaust heat recovery (EHR) ap...This study explores the potentials of employing an Organic Rankine Cycle (ORC) system with variable inlet guide vanes (VIV) turbine geometry designed on a GT-Suite platform for effective exhaust heat recovery (EHR) application onboard passenger vehicles. The ORC model simulation was based on vehicle speed mode using R245fa as working fluid to assess the thermal performance of the ORC system when utilizing modified turbine geometry. Interestingly, the model achieved a very improved performance in contrast to the model without a modified turbine configuration. The results revealed the average 2.32 kW ORC net output, 4.93% thermal efficiency, 6.1% mechanical efficiency, and 5.0% improved brake specific fuel consumption (BSFC) for the developed model. As determined by the performance indicators, these promising results from the model study show the prospect of EHR technology application in the transportation sector for reduction in exhaust emissions and fuel savings.展开更多
To get the sustainable society, the hydropower with not only the large but also the small/mini/micro capacities has been paid attention to in the power generation. The cross flow turbine can work effectively at the co...To get the sustainable society, the hydropower with not only the large but also the small/mini/micro capacities has been paid attention to in the power generation. The cross flow turbine can work effectively at the comparatively low head and/or low discharge, then the runner and the turbine profile has been optimizing. In this paper, the model turbine was prepared in accordance with the traditional design, and the performance and the flow condition were investigated experimentally at the various operating conditions. The hydraulic efficiency is doubtlessly maximal while the guide vane is at the normal/design position, and deteriorates in the lower discharges adjusted by the guide vane. Such deteriorations are brought from the unacceptable flow conditions in the inlet nozzle. To improve the efficiency dramatically in the lower discharge, the guide vane installed in the inlet nozzle was equipped with the current plate, and the fruitful effects of the plate on the efficiency were confirmed experimentally.展开更多
Exhaust gas recirculation control(EGRC),an inlet air heating technology,can be utilized in combination with inlet/variable guide vane control(IGV/VGVC) and fuel flow control(FFC) to regulate the load,thereby effective...Exhaust gas recirculation control(EGRC),an inlet air heating technology,can be utilized in combination with inlet/variable guide vane control(IGV/VGVC) and fuel flow control(FFC) to regulate the load,thereby effectively improving the part-load(i.e.,off-design) performance of the gas turbine combined cycle(GTCC).In this study,the E-,F-,and H-Class EGR-GTCC design and off-design system models were established and validated to perform a comparative analysis of the part-load performance under the EGR-IGV-FFC and conventional IGV-FFC strategies in the E/F/H-Class GTCC.Results show that EGR-IGV-FFC has considerable potential for the part-load performance enhancement and can show a higher combined cycle efficiency than IGV-FFC in the E-,F-,and H-Class GTCCs.However,the part-load performance improvement in the corresponding GTCC was weakened for the higher class of the gas turbine because of the narrower load range of EGR action and the deterioration of the gas turbine performance.Furthermore,EGR-IGV-FFC was inferior to IGV-FFC in improving the performance at loads below 50% for the H-Class GTCC.The results obtained in this paper could help guide the application of EGR-IGV-FFC to enhance the part-load performance of various classes of GTCC systems.展开更多
A new hydraulic design method of three-dimensional guide vane for centrifugal pump is proposed on the assumption that the fluid at the outlet of guide vane satisfies the uniform velocity moment condition.The geometry ...A new hydraulic design method of three-dimensional guide vane for centrifugal pump is proposed on the assumption that the fluid at the outlet of guide vane satisfies the uniform velocity moment condition.The geometry of blade is controlled by the distributed rule of blade angles along the meridional streamline which is described by a fourth-order polynomial.Experiment results demonstrate that the designed guide vane can overcome the drawback of two-dimensional guide vane,enlarge the high efficiency scope and improve the hydraulic performance of centrifugal pump on the off-design operation conditions.In comparison with the performance of the centrifugal pump without inlet guide vane,the peak value of efficiency can be enhanced by 2.13% after the three-dimensional guide vane was being installed.The three-dimensional entire flow field of the centrifugal pump with inlet guide vane is simulated,and the basic principle and mechanism of inlet guide vane pre-whirl regulation are analyzed.The validity of design method has been proved.展开更多
The valuation of the hydraulic performance of a centrifugal pump with pre-whirl regulation of the inlet guide vanes was studied experimentally by varying the pre-whirl angle from -60° to 60° with distances b...The valuation of the hydraulic performance of a centrifugal pump with pre-whirl regulation of the inlet guide vanes was studied experimentally by varying the pre-whirl angle from -60° to 60° with distances between the inlet guide vanes and the impeller inlet of 280 mm, 380 mm and 460 mm. The efficiency-flow curves and the characteristic curves were obtained for the pump for various operation conditions. The experiment results demonstrated that the pre-whirl regulation widened the high efficiency zone and improved the hydraulic performance for off-design conditions with the proper pre-whirl angle. The axial distance between the inlet guide vanes and the impeller inlet influenced the pre-whirl regulation effect of the inlet guide vanes with the best pre-whirl regulation effect obtained for an axial distance of 380 mm. These results showed that an appropriate axial distance between the inlet guide vanes and the impeller inlet can improve the fluid flow at the impeller entrance with pre-whirl regulation for centrifugal pumps.展开更多
Effects of the inlet guide vanes on the static characteristics, aerodynamic noise and internal flow characteristics of a small axial flow fan are studied in this work. The inlet guide vanes with different outlet angle...Effects of the inlet guide vanes on the static characteristics, aerodynamic noise and internal flow characteristics of a small axial flow fan are studied in this work. The inlet guide vanes with different outlet angle are designed, which are mounted on the casing and located at the upstream of the impeller of the prototype fan. Both steady and unsteady flow simulations arc performed. The steady flow is simulated by the calculations of Navier-Stokes equa- tions coupled with RNG k-epsilon turbulence model, while the unsteady flow is computed with large eddy simu- lation. According to the theoretical analysis, the inlet guide vanes with outlet angle of 60° are regarded as the op- timal inlet guide vanes. The static characteristic experiment is carried out in a standard test rig and the aerody- namic noise is tested in a semi-anechoic room. Then, performances of the fan with optimal inlet guide vanes are compared with those of the prototype fan. The results show that there is reasonable agreement between the simu- lation results and the experimental data. It is found that the static characteristics of small axial flow fan is im- proved obviously after installing the optimal inlet guide vanes. Meanwhile, the optimal inlet guide vanes have effect on reducing noise at the near field, but have little effect on the noise at the far field.展开更多
This paper describes the improvement of leading edge film cooling effectiveness for a turbine inlet guide vane by using fan-shaped film cooling holes. The modification details are presented in comparison with the base...This paper describes the improvement of leading edge film cooling effectiveness for a turbine inlet guide vane by using fan-shaped film cooling holes. The modification details are presented in comparison with the base-line configuration of cylindrical holes. Numerical simulations were carried out for the base-line and modified configurations by using CFX, in which the k-ε turbulence model and scalable wall function were chosen. Contours of adiabatic film cooling effectiveness on the blade surfaces and span-wise distributions of film cooling effectiveness downstream the rows of cooling holes interested for the different cooling configurations were compared and discussed. It is showed that with the use of fan-shaped cooling holes around the leading edge, the adiabatic film cooling effectiveness can be enhanced considerably. In comparison with the cylindrical film cooling holes, up to 40% coolant mass flow can be saved by using fan-shaped cooling holes to obtain the comparable film cooling effectiveness for the studied inlet guide vane.展开更多
The inlet attack angle of rotor blade reasonably can be adjusted with the change of the stagger angle of inlet guide vane (IGV); so the efficiency of each condition will be affected. For the purpose to improve the eff...The inlet attack angle of rotor blade reasonably can be adjusted with the change of the stagger angle of inlet guide vane (IGV); so the efficiency of each condition will be affected. For the purpose to improve the efficiency, the DSP (Digital Signal Processor) controller is designed to adjust the stagger angle of IGV automatically in order to optimize the efficiency at any operating condition. The A/D signal collection includes inlet static pressure, outlet static pressure, outlet total pressure, rotor speed and torque signal, the efficiency can be calculated in the DSP, and the angle signal for the stepping motor which control the IGV will be sent out from the D/A. Experimental investigations are performed in a three-stage, low-speed axial compressor with variable inlet guide vanes. It is demonstrated that the DSP designed can well adjust the stagger angle of IGV online, the efficiency under different conditions can be optimized. This establishment of DSP online adjustment scheme may provide a practical solution for improving performance of multi-stage axial flow compressor when its operating condition is varied.展开更多
文摘This study explores the potentials of employing an Organic Rankine Cycle (ORC) system with variable inlet guide vanes (VIV) turbine geometry designed on a GT-Suite platform for effective exhaust heat recovery (EHR) application onboard passenger vehicles. The ORC model simulation was based on vehicle speed mode using R245fa as working fluid to assess the thermal performance of the ORC system when utilizing modified turbine geometry. Interestingly, the model achieved a very improved performance in contrast to the model without a modified turbine configuration. The results revealed the average 2.32 kW ORC net output, 4.93% thermal efficiency, 6.1% mechanical efficiency, and 5.0% improved brake specific fuel consumption (BSFC) for the developed model. As determined by the performance indicators, these promising results from the model study show the prospect of EHR technology application in the transportation sector for reduction in exhaust emissions and fuel savings.
文摘To get the sustainable society, the hydropower with not only the large but also the small/mini/micro capacities has been paid attention to in the power generation. The cross flow turbine can work effectively at the comparatively low head and/or low discharge, then the runner and the turbine profile has been optimizing. In this paper, the model turbine was prepared in accordance with the traditional design, and the performance and the flow condition were investigated experimentally at the various operating conditions. The hydraulic efficiency is doubtlessly maximal while the guide vane is at the normal/design position, and deteriorates in the lower discharges adjusted by the guide vane. Such deteriorations are brought from the unacceptable flow conditions in the inlet nozzle. To improve the efficiency dramatically in the lower discharge, the guide vane installed in the inlet nozzle was equipped with the current plate, and the fruitful effects of the plate on the efficiency were confirmed experimentally.
基金financial support from the Fundamental Research Project in the Chinese National Sciences and Technology Major Project (Grant No.2017-1-0002-0002)。
文摘Exhaust gas recirculation control(EGRC),an inlet air heating technology,can be utilized in combination with inlet/variable guide vane control(IGV/VGVC) and fuel flow control(FFC) to regulate the load,thereby effectively improving the part-load(i.e.,off-design) performance of the gas turbine combined cycle(GTCC).In this study,the E-,F-,and H-Class EGR-GTCC design and off-design system models were established and validated to perform a comparative analysis of the part-load performance under the EGR-IGV-FFC and conventional IGV-FFC strategies in the E/F/H-Class GTCC.Results show that EGR-IGV-FFC has considerable potential for the part-load performance enhancement and can show a higher combined cycle efficiency than IGV-FFC in the E-,F-,and H-Class GTCCs.However,the part-load performance improvement in the corresponding GTCC was weakened for the higher class of the gas turbine because of the narrower load range of EGR action and the deterioration of the gas turbine performance.Furthermore,EGR-IGV-FFC was inferior to IGV-FFC in improving the performance at loads below 50% for the H-Class GTCC.The results obtained in this paper could help guide the application of EGR-IGV-FFC to enhance the part-load performance of various classes of GTCC systems.
基金supported by the National Natural Science Foundation of China(Grant No.50776052)the National High-tech R&D Program of China(863Program)(Grant No.2008AA05Z201)
文摘A new hydraulic design method of three-dimensional guide vane for centrifugal pump is proposed on the assumption that the fluid at the outlet of guide vane satisfies the uniform velocity moment condition.The geometry of blade is controlled by the distributed rule of blade angles along the meridional streamline which is described by a fourth-order polynomial.Experiment results demonstrate that the designed guide vane can overcome the drawback of two-dimensional guide vane,enlarge the high efficiency scope and improve the hydraulic performance of centrifugal pump on the off-design operation conditions.In comparison with the performance of the centrifugal pump without inlet guide vane,the peak value of efficiency can be enhanced by 2.13% after the three-dimensional guide vane was being installed.The three-dimensional entire flow field of the centrifugal pump with inlet guide vane is simulated,and the basic principle and mechanism of inlet guide vane pre-whirl regulation are analyzed.The validity of design method has been proved.
基金supported by the National Natural Science Foundation of China (Grant No. 51176088)the National Basic Research Program of China ("973" Project) (Grant No. 2009CB724304) the General Financial Grant from the China Postdoctoral Science Foundation (Grant No. 2011M500315)
文摘The valuation of the hydraulic performance of a centrifugal pump with pre-whirl regulation of the inlet guide vanes was studied experimentally by varying the pre-whirl angle from -60° to 60° with distances between the inlet guide vanes and the impeller inlet of 280 mm, 380 mm and 460 mm. The efficiency-flow curves and the characteristic curves were obtained for the pump for various operation conditions. The experiment results demonstrated that the pre-whirl regulation widened the high efficiency zone and improved the hydraulic performance for off-design conditions with the proper pre-whirl angle. The axial distance between the inlet guide vanes and the impeller inlet influenced the pre-whirl regulation effect of the inlet guide vanes with the best pre-whirl regulation effect obtained for an axial distance of 380 mm. These results showed that an appropriate axial distance between the inlet guide vanes and the impeller inlet can improve the fluid flow at the impeller entrance with pre-whirl regulation for centrifugal pumps.
基金supported by National Natural Science Foundation of China No.51276172Public Welfare Technology Application Projects of Zhejiang Province NO.2015C31002Open Foundation of Zhejiang Provincial Top Key Academic Discipline of Mechanical Engineering and ZSTUMEOIA04 and 2013TD18
文摘Effects of the inlet guide vanes on the static characteristics, aerodynamic noise and internal flow characteristics of a small axial flow fan are studied in this work. The inlet guide vanes with different outlet angle are designed, which are mounted on the casing and located at the upstream of the impeller of the prototype fan. Both steady and unsteady flow simulations arc performed. The steady flow is simulated by the calculations of Navier-Stokes equa- tions coupled with RNG k-epsilon turbulence model, while the unsteady flow is computed with large eddy simu- lation. According to the theoretical analysis, the inlet guide vanes with outlet angle of 60° are regarded as the op- timal inlet guide vanes. The static characteristic experiment is carried out in a standard test rig and the aerody- namic noise is tested in a semi-anechoic room. Then, performances of the fan with optimal inlet guide vanes are compared with those of the prototype fan. The results show that there is reasonable agreement between the simu- lation results and the experimental data. It is found that the static characteristics of small axial flow fan is im- proved obviously after installing the optimal inlet guide vanes. Meanwhile, the optimal inlet guide vanes have effect on reducing noise at the near field, but have little effect on the noise at the far field.
基金supported by the National 973 Program of China through grant number 2007CB210108
文摘This paper describes the improvement of leading edge film cooling effectiveness for a turbine inlet guide vane by using fan-shaped film cooling holes. The modification details are presented in comparison with the base-line configuration of cylindrical holes. Numerical simulations were carried out for the base-line and modified configurations by using CFX, in which the k-ε turbulence model and scalable wall function were chosen. Contours of adiabatic film cooling effectiveness on the blade surfaces and span-wise distributions of film cooling effectiveness downstream the rows of cooling holes interested for the different cooling configurations were compared and discussed. It is showed that with the use of fan-shaped cooling holes around the leading edge, the adiabatic film cooling effectiveness can be enhanced considerably. In comparison with the cylindrical film cooling holes, up to 40% coolant mass flow can be saved by using fan-shaped cooling holes to obtain the comparable film cooling effectiveness for the studied inlet guide vane.
基金supported by National Basic Research Program of China 2007CB210104National Natural Science Foundation of China with projects No.51010007.and No.50736007
文摘The inlet attack angle of rotor blade reasonably can be adjusted with the change of the stagger angle of inlet guide vane (IGV); so the efficiency of each condition will be affected. For the purpose to improve the efficiency, the DSP (Digital Signal Processor) controller is designed to adjust the stagger angle of IGV automatically in order to optimize the efficiency at any operating condition. The A/D signal collection includes inlet static pressure, outlet static pressure, outlet total pressure, rotor speed and torque signal, the efficiency can be calculated in the DSP, and the angle signal for the stepping motor which control the IGV will be sent out from the D/A. Experimental investigations are performed in a three-stage, low-speed axial compressor with variable inlet guide vanes. It is demonstrated that the DSP designed can well adjust the stagger angle of IGV online, the efficiency under different conditions can be optimized. This establishment of DSP online adjustment scheme may provide a practical solution for improving performance of multi-stage axial flow compressor when its operating condition is varied.