For uniform tube inner coating of non-conductive thin films, the double-ended coaxial magnetron pulsed plasma (DCMPP) method was investigated. In this study, coating of TiN and TiO2 was performed. It was clearly shown...For uniform tube inner coating of non-conductive thin films, the double-ended coaxial magnetron pulsed plasma (DCMPP) method was investigated. In this study, coating of TiN and TiO2 was performed. It was clearly shown that the extended anode effect was strongly influenced by the electric resistance of the coated thin films on the inner surface of an insulator tube. Additionally, high frequency (100 kHz) was better for relatively high plasma density. On the other hand, in the case of titanium oxide deposition, negative ion productions drastically decrease the deposition rate and the shifting velocity of plasma main position for coated TiO2 films.展开更多
As a new spraying technology used in the remanufacturing engineering, electro-thermal explosion spraying holds a lot of advantages. Electro-thermal explosion spraying coating aliquation phenomena are reduced and non-c...As a new spraying technology used in the remanufacturing engineering, electro-thermal explosion spraying holds a lot of advantages. Electro-thermal explosion spraying coating aliquation phenomena are reduced and non-crystal, micro-crystal and millimicron-crystal and other microstructure are formed. The corrosion-resistance ability of electro-thermal explosion spraying coating in high temperature environment was surveyed respectively. SEM equipped with EDS was employed to analyze the microstructure of spraying coating before and after corrosion. The corrosion-resistance mechanism of the spraying coating was discussed.展开更多
Pencil hardness testing,electrochemical impedance spectroscopy,scanning electron microscopy,and scanning Kelvin probe microscopy were used to study the local corrosion characteristics of a graphene-oxide-modified inne...Pencil hardness testing,electrochemical impedance spectroscopy,scanning electron microscopy,and scanning Kelvin probe microscopy were used to study the local corrosion characteristics of a graphene-oxide-modified inner coating.The effect of chloride concentration on the corrosion of the damaged inner coating was studied.The effects of chloride ions on damaged internal coatings and graphene-oxide-modified internal coatings were investigated.It was proposed to add graphene oxide into the epoxy coating to effectively inhibit the metal corrosion at the breakage.Because of the existence of graphene oxide(GO),the modified coating had a better physical property and had the effective infiltration of H2O and Cl^- into the coating.The results showed that graphene oxide coatings can give X80 steel better corrosion resistance in sodium chloride solution.展开更多
Low alloy steels are widely used in bridges,construction,chemical and various equipment and metal components due to their low cost and excellent mechanical strength.Information in the literature related to the prepara...Low alloy steels are widely used in bridges,construction,chemical and various equipment and metal components due to their low cost and excellent mechanical strength.Information in the literature related to the preparation,advantages and disadvantages,and applications along with research progress of various types of protective coatings suitable for low-alloy steel surfaces is reviewed,while a conclusive and comparative analysis is also afforded to the numerous factors influencing the protective ability of coatings.The characteristics of coatings drawn from the latest published literature are discussed and suggest that the modification of traditional metal coatings and the development of new organic coatings under the consideration of environmental protection,low cost,simplicity and large-scale industrial application are simultaneously proceeding,which holds promise for improving the understanding of corrosion protection in related fields and helps to address some of the limitations identified with more conventional coating techniques.展开更多
文摘For uniform tube inner coating of non-conductive thin films, the double-ended coaxial magnetron pulsed plasma (DCMPP) method was investigated. In this study, coating of TiN and TiO2 was performed. It was clearly shown that the extended anode effect was strongly influenced by the electric resistance of the coated thin films on the inner surface of an insulator tube. Additionally, high frequency (100 kHz) was better for relatively high plasma density. On the other hand, in the case of titanium oxide deposition, negative ion productions drastically decrease the deposition rate and the shifting velocity of plasma main position for coated TiO2 films.
文摘As a new spraying technology used in the remanufacturing engineering, electro-thermal explosion spraying holds a lot of advantages. Electro-thermal explosion spraying coating aliquation phenomena are reduced and non-crystal, micro-crystal and millimicron-crystal and other microstructure are formed. The corrosion-resistance ability of electro-thermal explosion spraying coating in high temperature environment was surveyed respectively. SEM equipped with EDS was employed to analyze the microstructure of spraying coating before and after corrosion. The corrosion-resistance mechanism of the spraying coating was discussed.
基金Project(51674212)supported by the National Natural Science Foundation of China。
文摘Pencil hardness testing,electrochemical impedance spectroscopy,scanning electron microscopy,and scanning Kelvin probe microscopy were used to study the local corrosion characteristics of a graphene-oxide-modified inner coating.The effect of chloride concentration on the corrosion of the damaged inner coating was studied.The effects of chloride ions on damaged internal coatings and graphene-oxide-modified internal coatings were investigated.It was proposed to add graphene oxide into the epoxy coating to effectively inhibit the metal corrosion at the breakage.Because of the existence of graphene oxide(GO),the modified coating had a better physical property and had the effective infiltration of H2O and Cl^- into the coating.The results showed that graphene oxide coatings can give X80 steel better corrosion resistance in sodium chloride solution.
基金This paper is supported by Key Scientific Research Project in Shanxi Province(Grant Nos.201903D111008 and 202003D111001)National Natural Science Foundation of China(Grant No.52071227)+4 种基金Fundamental Research Program of Shanxi Province(Grant No.202103021223293)Scientific and Technological Innovation Programs of Higher Education Institutions in Shanxi(Grant No.2021L306)Scientific Research Fund of Taiyuan University of Science and Technology(Grant No.20202044)Award Fund for Outstanding Doctors in Shanxi Province(Grant No.20212041)Postgraduate Education Innovation Project of Shanxi Province(Grant Nos.2022Y686 and 2022Y684).
文摘Low alloy steels are widely used in bridges,construction,chemical and various equipment and metal components due to their low cost and excellent mechanical strength.Information in the literature related to the preparation,advantages and disadvantages,and applications along with research progress of various types of protective coatings suitable for low-alloy steel surfaces is reviewed,while a conclusive and comparative analysis is also afforded to the numerous factors influencing the protective ability of coatings.The characteristics of coatings drawn from the latest published literature are discussed and suggest that the modification of traditional metal coatings and the development of new organic coatings under the consideration of environmental protection,low cost,simplicity and large-scale industrial application are simultaneously proceeding,which holds promise for improving the understanding of corrosion protection in related fields and helps to address some of the limitations identified with more conventional coating techniques.