Thermal Effect of the Cable-Stayed Bridge Tower 被引量:3
1
作者 Zhang Hai-long, Li Jun, Liu Chang-guo, Jiang Tian-hua, Wei jun School of Civil Engineering and Mechanics, Huazhong University of Science and Technology, Wuhan 430074, Hubei, China 《Wuhan University Journal of Natural Sciences》 CAS 2003年第04A期1121-1125,共5页
This paper studies the thermal effect of the cable-stayed bridge tower based on full time accurate measurement and finite element analysis on Xiantao Hanjiang River Highway Bridge. The measured results and the displac... This paper studies the thermal effect of the cable-stayed bridge tower based on full time accurate measurement and finite element analysis on Xiantao Hanjiang River Highway Bridge. The measured results and the displacement variation of top tower show that the tower rotates periodically when it is exposed in sunshine. But the tower column will not decline when there is no sunshine. In spite of in winter or in summer, the period when the tower column changed smallest is from 0∶00 am to 5∶00 am. The time period when the tower column has maximum deviation lags behind the time when the tower column has maximum temperature difference, and this phenomenon is obvious in winter. The conclusions also have directive value in predicting the tower deformations and their directions in construction control of cable-stayed bridge, and in verifying the finite element program. 展开更多
关键词 bridge tower thermal effect DEFORMATION full time measurement
下载PDF
Investigation the Correlation between Thermal Bridging and Geometries in Concrete Buildings
2
作者 Ali Vaseghi Craig Capano 《Journal of Building Construction and Planning Research》 2023年第4期87-100,共14页
This article focuses on the investigation of the correlation between thermal bridging and various geometric configurations. The article employs QuickField software for conducting three-dimensional steady-state heat tr... This article focuses on the investigation of the correlation between thermal bridging and various geometric configurations. The article employs QuickField software for conducting three-dimensional steady-state heat transfer simulations to investigate the thermal behaviors of diverse geometric shapes. Significantly, this study involves the simulation of four distinct geometries including concrete circular, square, rectangular, and triangular column through an insulated concrete layer while all geometries maintain the consistent surface areas. The simulations yield findings indicating that circular thermal bridging has the best thermal performance, while rectangular thermal bridging displays comparatively the lowest thermal efficiency. Furthermore, the results indicate that alterations in the perimeter of thermal bridge interfaces, while maintaining a constant area, exert a more pronounced influence on the thermal performance of the geometries compared to proportional changes in area while preserving the perimeter. The study’s findings aid building designers and architects in creating more energy-efficient structural and architectural elements by incorporating thermally efficient geometries and forms. . 展开更多
关键词 thermal bridging Heat Flux Building Energy Building Envelope Concrete Building
下载PDF
Analysis of Thermal Bridge Impact in a Hotel Building for the Eight Brazilian Bioclimatic Zones
3
作者 Eduardo Grala da Cunha Beatriz Echenique Gioielli 《Journal of Civil Engineering and Architecture》 2015年第4期393-400,共8页
关键词 气候区 热桥 生物 巴西 钢筋混凝土 大厦 酒店 结构体系
下载PDF
Thermal Bridges Impact on Energy Consumption in Residential Buildings Considering the Brazilian Bioclimatic Zoning
4
作者 Eduardo Grala da Cunha Julye Ramalho de Freitas +2 位作者 Beatriz Echenique Gioielli Rodrigo Karini Leitzke Letiane Beninca 《Journal of Civil Engineering and Architecture》 2016年第10期1114-1130,共17页
下载PDF
An integrated computational method for calculating dynamic thermal bridges of building facades in tropical countries
5
作者 Miktha Farid Alkadri Muhammad Rafif Cahyadi Agung Francesco De Luca 《Frontiers of Architectural Research》 CSCD 2024年第1期201-218,共18页
Identifying thermal bridges on building façades has been a great challenge for architects,especially during the conceptual design stage.This is not only due to the complexity of parameters when calculating therma... Identifying thermal bridges on building façades has been a great challenge for architects,especially during the conceptual design stage.This is not only due to the complexity of parameters when calculating thermal bridges,but also lack of feature integration between building energy simulation(BES)tools and the actual building conditions.For example,existing BES tools predominantly calculate thermal bridges only in steady state without considering the temperature dynamic behaviour of building outdoors.Consequently,relevant features such as thermal delay,decrement factor,and operative temperature are often neglected,and this can lead to miscalculation of energy consumption.This study then proposes an integrated method to calculate dynamic thermal bridges under transient conditions by incorporating field observations and computational simulations of thermal bridges.More specifically,the proposed method employs several measurement tools such as HOBO data logger to record the actual conditions of indoor and outdoor room temperature and thermal cameras to identify the surface temperature of selected building junctions.The actual datasets are then integrated with the simulation workflow developed in BES tools.This study ultimately enables architects not only to identify potential thermal bridges on existing building façades but also to support material and geometric exploration in early design phase. 展开更多
关键词 thermal bridges Dynamic calculation thermal delay Cooling load Computational design method
原文传递
Formation Process of Intermittent Molten Bridge Between Au-Plated Contacts at Super Low Breaking Velocity 被引量:2
6
作者 任万滨 常成 陈宇 《Plasma Science and Technology》 SCIE EI CAS CSCD 2016年第3期236-240,共5页
This paper presents the molten bridge behaviors of Au-plated material at super low breaking velocity conditions by introducing our new designed test rig. The typical waveforms of the contact voltage and contact force ... This paper presents the molten bridge behaviors of Au-plated material at super low breaking velocity conditions by introducing our new designed test rig. The typical waveforms of the contact voltage and contact force during breaking are investigated under the load of 5- 25 V/0.2-1 A and velocity of 25-150 nm/s. It is shown that the intermittent molten bridge is formed from the competition of multitude contact a-spots for current distribution and the solid- liquid mixing characteristics of a molten bridge. Also, it is proved that the bridge is not composed by the completed melted metal by using FEM thermal simulation and the voltage-temperature relation. The observed surface morphology reveals that the scattered and stacked melted regions are attributed to the intermittent bridge. Finally, the effects of breaking velocity and electrical load on bridge length and duration are also analyzed. 展开更多
关键词 molten bridge contact a-spot breaking velocity thermal simulation
下载PDF
Study on the Temperature of the Bridge Wire in the Initiator Used in Nuclear Explosion Valve 被引量:1
7
作者 Lan Shi An-Min Yang +2 位作者 Ying-Chun Zhang Yuan-He Wang Zhanying Li 《American Journal of Analytical Chemistry》 2016年第12期908-917,共10页
This paper established the mathematical model of bridge wire temperature rise under direct current condition and gave the solution. It computed bridge wire temperature by using the thermal-electric coupling method pro... This paper established the mathematical model of bridge wire temperature rise under direct current condition and gave the solution. It computed bridge wire temperature by using the thermal-electric coupling method provided by ANSYS-Workbench finite element analysis software. In the end, the temperature bridge wire applied to different electric current was measured by the infrared thermal imaging temperature measurement method. The result shows that the ANSYS simulation results are in agreement with the theoretical calculation and the experimental results. It is feasible to compute bridge wire temperature of initiator by using ANSYS-Workbench software, and it is an important method to analyze complex structure of pyrotechnics. 展开更多
关键词 bridge Wire Temperature ANSYS-Workbench thermal-Electric Coupling Infrared thermal Imaging
下载PDF
Numerical calculation on solar temperature field of a cable-stayed bridge with U-shaped section on high-speed railway 被引量:3
8
作者 刘文硕 戴公连 饶少臣 《Journal of Central South University》 SCIE EI CAS 2014年第8期3345-3352,共8页
Based on transient temperature field theory of heat conduction,the solar temperature field calculation model of U-shape sectioned high-speed railway cable-stayed bridge under actions of concrete beams and ballast was ... Based on transient temperature field theory of heat conduction,the solar temperature field calculation model of U-shape sectioned high-speed railway cable-stayed bridge under actions of concrete beams and ballast was established.Using parametric programming language,finite element calculation modules considering climate conditions,bridge site,structure dimension and material thermophysical properties were compiled.Six standard day cycles with the strongest yearly radiation among the bridge sites were selected for sectional solar temperature field calculation and temperature distributions under different temperature-sensitive parameters were compared.The results show that under the influence of sunshine,U-shape section of the beam shows obvious nonlinear distribution characteristics and the maximum cross-section temperature difference is more than 21 °C; the ballast significantly reduces sunshine temperature difference of the beam and temperature peak of the bottom margin lags with the increase of ballast thickness; the maximum cross-section vertical temperature gradient appears in summer while large transverse temperature difference appears in winter. 展开更多
关键词 温度场计算 U形截面 高速铁路 太阳能 斜拉桥 数值计算 垂直温度梯度 混凝土梁
下载PDF
Simulation of Temperature Field in Original Segment of Concrete Box-Girder Bridge
9
作者 徐丰 徐雯 王波 《Journal of Southwest Jiaotong University(English Edition)》 2009年第2期102-108,共7页
Temperature field and its variation with time are necessary for analyzing the thermo-mechanical performance of mass concrete structures at their early ages. This paper carries out a temperature field simulation analys... Temperature field and its variation with time are necessary for analyzing the thermo-mechanical performance of mass concrete structures at their early ages. This paper carries out a temperature field simulation analysis for an original segment of a real box girder bridge with the finite element software ANSYS. Two representative exothermic rate models are used to describe the heat- releasing process caused by the cement hydration in concrete. The exothermic rate model that conforms to reality more closely is recognized by comparing the simulation results with the data gathered from the optical fiber temperature sensors pre-embedded in the original segment. The air temperature and wind velocity that constitute thermal boundary conditions are determined in the light of the local meteorological department and correlative research achievements of recent years. Moreover, the consideration for the steel formwork acting as a barrier to heat loss is also proved to be beneficial to improve the simulation effect. 展开更多
关键词 Concrete box-girder bridge Original segment thermal analysis Hydration heat Numerical simulation
下载PDF
Eliminating Fastener Thermal Bridging in Low Slope Roofs: Energy Efficiency Savings versus Installation Costs
10
作者 Thomas J. Taylor 《Open Journal of Energy Efficiency》 2020年第2期94-110,共17页
Low-slope roofing assemblies include a wide range of insulation and single ply membrane attachment methods. Previous studies have shown that mechanical attachment using metal fasteners leads to significant thermal bri... Low-slope roofing assemblies include a wide range of insulation and single ply membrane attachment methods. Previous studies have shown that mechanical attachment using metal fasteners leads to significant thermal bridging and consequent loss of insulation value and reduction of long term thermal efficiency. This study calculates the costs associated with mechanical attachment in terms of lost insulation value, increased long-term energy costs, and the material and labor costs associated with installation of these common systems. Energy efficiency reductions using metal fasteners were modeled for eight US cities in a range of climate zones. From the data, it was possible to calculate target costs (labor plus materials) that would make adhered systems cost effective. There are many options available to adhere single ply roof system components, such as solvent-based adhesives and low-rise urethane foams, together with different application approaches such as broom, spray, and ribbon methods. The cost targets derived in this study can help optimize the use of such materials and application methods such that the thermal bridging due to fasteners could be substantially reduced or eliminated. 展开更多
关键词 Energy Efficiency thermal bridging Roof Assemblies
下载PDF
SFCC现场导热系数与温度场实测及预测方法研究
11
作者 牛艳伟 匡笑艳 +2 位作者 郑军涛 党王辉 汤颖颖 《建筑材料学报》 EI CAS CSCD 北大核心 2024年第3期245-252,282,共9页
为确定钢纤维页岩陶粒混凝土(SFCC)现场实际的导热系数,与桥面板施工同步制作了不同钢纤维体积分数的SFCC试件,采用热板法进行测定,校核并扩展了导热系数预测公式,并且对高温沥青摊铺时SFCC桥面板的温度场进行了实测和数值模拟.结果表明... 为确定钢纤维页岩陶粒混凝土(SFCC)现场实际的导热系数,与桥面板施工同步制作了不同钢纤维体积分数的SFCC试件,采用热板法进行测定,校核并扩展了导热系数预测公式,并且对高温沥青摊铺时SFCC桥面板的温度场进行了实测和数值模拟.结果表明:环境湿度为67%时,SFCC的实测导热系数为0.915~1.409 W/(m·K),增加钢纤维体积分数可提高SFCC导热系数;考虑湿度和钢纤维影响后的扩展Maxwell公式预测值与实测值吻合良好;高温沥青摊铺时桥面板SFCC混凝土内的温度梯度可达20.5℃,超过规范日温差,采用数值模拟可有效计算桥面板温度场. 展开更多
关键词 钢纤维 页岩陶粒混凝土 组合桥面 导热系数 高温沥青摊铺温度场
下载PDF
预制内外复合保温模壳拼装墙体热工性能研究
12
作者 王洪镇 张笑笑 +4 位作者 杨永恒 王璟 褚文斌 高潇 李雨泽 《混凝土与水泥制品》 2024年第4期70-76,共7页
为探究预制内外复合保温模壳拼装墙体结构中的卡板连接件对墙体热工性能的影响,通过热工理论计算、试验研究、ANSYS有限元热分析模拟软件3种方法,对比分析了无连接件、不同数量连接件以及双面抹灰不同条件下墙体的传热系数。结果表明:... 为探究预制内外复合保温模壳拼装墙体结构中的卡板连接件对墙体热工性能的影响,通过热工理论计算、试验研究、ANSYS有限元热分析模拟软件3种方法,对比分析了无连接件、不同数量连接件以及双面抹灰不同条件下墙体的传热系数。结果表明:在无连接件条件下,实际墙体热工试验测试值与热工理论计算值的误差较小;连接件数量越多,热桥效应越明显,墙体的热工性能越差;采用有限元模拟软件对墙体进行热工设计结果较精确,可作为设计依据;研究结果可为模壳拼装墙体在超低能耗建筑的应用及能耗分析提供借鉴。 展开更多
关键词 内外复合保温模壳 卡板连接件 拼装墙体 热桥效应 传热系数
下载PDF
基于瞬态热桥法的固体材料导热系数测量及其不确定度的评定
13
作者 周逸 潘永杲 +3 位作者 闵琪涛 邱萍 姚建 李峻 《计量学报》 CSCD 北大核心 2024年第5期654-665,共12页
在Hammerschmidt建立瞬态热桥(THB)法理论的基础上,改进了恒定输入电流模式下导热系数解析模型和修正模型,对THB测量传感器进行了结构设计和仿真验证。搭建了测量范围为0.01~150 W/(m·K)的实验装置,并对修正模型进行了测量验证。... 在Hammerschmidt建立瞬态热桥(THB)法理论的基础上,改进了恒定输入电流模式下导热系数解析模型和修正模型,对THB测量传感器进行了结构设计和仿真验证。搭建了测量范围为0.01~150 W/(m·K)的实验装置,并对修正模型进行了测量验证。对聚苯乙烯、有机玻璃和45号钢等7种固体材料进行了实验测量,对测量结果进行了不确定度的评定,并与不同仪器的测量结果进行了比较。结果表明,实验装置的测量重复性优于1.7%,与参考值的相对偏差在±5%以内,经评定测量结果的相对扩展不确定度为U_(rel)=2.94%(k=2)。 展开更多
关键词 热物性参数 导热系数 瞬态热桥法 仿真验证 测量比较 不确定度评定
下载PDF
超低能耗建筑悬挑构件热桥隔断措施研究
14
作者 王宇飞 叶云磊 +2 位作者 邵志兵 黄山 徐晗 《建筑施工》 2024年第6期962-965,共4页
相较于常规建筑,超低能耗建筑对围护系统的保温性能有着更严格的要求,其中,围护系统热桥控制是实现超低能耗建筑的关键措施。在围护系统保温构造设计时,由于悬挑构件隔断了保温层,成为热桥集中的部位,为削弱或消除此部位热桥,通常采用... 相较于常规建筑,超低能耗建筑对围护系统的保温性能有着更严格的要求,其中,围护系统热桥控制是实现超低能耗建筑的关键措施。在围护系统保温构造设计时,由于悬挑构件隔断了保温层,成为热桥集中的部位,为削弱或消除此部位热桥,通常采用保温材料包覆悬挑构件的方式进行处理,但此方式存在工期影响严重及成本增量大的弊端,随着超低能耗建筑的推广,更多形式的热桥隔断措施在实际工程中得到了应用。结合常见的超低能耗建筑悬挑构件热桥隔断措施,从施工角度及隔热性能方面进行研究分析,以供同类工程借鉴。 展开更多
关键词 超低能耗 悬挑构件 热桥 隔热措施
下载PDF
寒冷A区超低能耗建筑围护结构热桥部位的节能设计策略——以烟台飞龙集团有限公司创新研发中心为例 被引量:2
15
作者 徐静 张肖 +2 位作者 秦桂明 王丽 李孟庭 《烟台大学学报(自然科学与工程版)》 2024年第1期118-124,共7页
为响应“双碳”背景下实现节能减排降碳绿色转型的需求,结合烟台飞龙集团有限公司创新研发中心项目的实践,探讨并提出了适合寒冷A区超低能耗建筑发展的围护结构热桥部位的节点优化策略,有利于解决普通节能建筑的典型通用节点设计与超低... 为响应“双碳”背景下实现节能减排降碳绿色转型的需求,结合烟台飞龙集团有限公司创新研发中心项目的实践,探讨并提出了适合寒冷A区超低能耗建筑发展的围护结构热桥部位的节点优化策略,有利于解决普通节能建筑的典型通用节点设计与超低能耗建筑节点设计之间的不适配问题。 展开更多
关键词 “双碳” 超低能耗建筑 围护结构 建筑热桥
下载PDF
基于BP神经网络的混凝土箱梁最大温度梯度预测
16
作者 王凯 张勇 +3 位作者 刘建磊 何旭辉 蔡陈之 黄石基 《铁道科学与工程学报》 EI CAS CSCD 北大核心 2024年第2期837-850,共14页
混凝土箱梁受到太阳辐射、大气温度波动等多种气象因素的综合作用,结构内部会产生显著的非均匀温度分布。截面内温度梯度可能会导致桥梁结构产生过大的温度应力与温度变形,影响桥梁结构的安全性和耐久性。本文旨在探究气象因素对混凝土... 混凝土箱梁受到太阳辐射、大气温度波动等多种气象因素的综合作用,结构内部会产生显著的非均匀温度分布。截面内温度梯度可能会导致桥梁结构产生过大的温度应力与温度变形,影响桥梁结构的安全性和耐久性。本文旨在探究气象因素对混凝土箱梁温度场的影响机理,并提出一种能精确预测中国多区域混凝土箱梁截面最大温度梯度的方法。首先建立了日照条件下混凝土箱梁温度场计算模型,将2 a以上气象资料作为输入条件,对多个地区混凝土箱梁温度场长期变化进行了仿真模拟,并对混凝土箱梁截面温度梯度的长期变化趋势进行了分析。然后利用主成分分析(PCA)确定了混凝土箱梁截面最大温度梯度预测模型所需的输入参数。最后利用遗传算法优化的BP神经网络建立预测混凝土箱梁竖向、横向温度梯度的网络模型,并与混凝土箱梁截面温度梯度进行比较。结果分析表明BP神经网络模型可以精确地预测混凝土箱梁最大温度梯度,预测值平均绝对误差(AAE)均小于0.9℃,均方根误差(RMSE)均小于1.2℃,决定系数(R^(2))均大于0.9。基于当地气象条件,本文利用经典的BP神经网络模型所建立的预测模型对中国不同地区的混凝土箱梁截面最大温度梯度均能给出准确的预测,为混凝土箱梁设计和施工阶段的最大温度梯度的计算提供一种高效的方法。 展开更多
关键词 桥梁工程 日照温度作用 BP神经网络 混凝土箱梁 温度梯度
下载PDF
基于升降轨SAR数据的连续箱梁桥精细变形
17
作者 魏恋欢 王啸天 +1 位作者 敖萌 李鑫 《东北大学学报(自然科学版)》 EI CAS CSCD 北大核心 2024年第3期391-400,共10页
针对桥梁精细变形监测问题,提出一种考虑由温度引起的桥梁变形(简称温度变形)的升降轨合成孔径雷达(synthetic aperture radar,SAR)数据融合方法.首先,以连续箱梁桥为研究对象,分别使用升降轨SAR数据集,基于小基线子集干涉测量法(small ... 针对桥梁精细变形监测问题,提出一种考虑由温度引起的桥梁变形(简称温度变形)的升降轨合成孔径雷达(synthetic aperture radar,SAR)数据融合方法.首先,以连续箱梁桥为研究对象,分别使用升降轨SAR数据集,基于小基线子集干涉测量法(small baseline subsets interferometric SAR,SBAS-InSAR)提取视线向(line-of-sight,LOS)变形;然后,利用最小二乘法构建温度变形模型,分离周期性温度变形与长期性趋势变形;最后,结合桥梁结构特征,基于时空插值和奇异值分解方法实现升降轨数据融合,提取温度变形、纵桥向(即桥梁延伸方向)及垂直向趋势变形,分析桥梁变形机制及变形成因.结果表明,该方法可提取精确的桥梁温度变形及三维变形,为桥梁健康监测提供可靠的方法支撑. 展开更多
关键词 小基线子集 连续箱梁桥 温度变形建模 数据融合 三维变形
下载PDF
连接件对夹心墙板热性能和能耗的影响
18
作者 宋润钊 董宪章 +2 位作者 王津津 郑旭 高涛 《低温建筑技术》 2024年第2期1-4,共4页
为解决连接件因热桥现象而产生大量能耗问题,又能为连接件设计提供研究基础,文中采用有限元模拟方法,研究了不同连接件材料、类型对夹心墙板热性能和五个热工区能耗的影响。结果表明热桥影响随连接件断桥尺寸的增加而降低,连接件产生的... 为解决连接件因热桥现象而产生大量能耗问题,又能为连接件设计提供研究基础,文中采用有限元模拟方法,研究了不同连接件材料、类型对夹心墙板热性能和五个热工区能耗的影响。结果表明热桥影响随连接件断桥尺寸的增加而降低,连接件产生的能耗主要受连接件属性和环境影响。研究结论有助于区分热桥影响和能耗差异,对指导连接件的工程应用具有较大价值。 展开更多
关键词 夹心墙板 热桥现象 热工区能耗
下载PDF
线传热系数ψ浅析
19
作者 易嘉 《建筑节能(中英文)》 CAS 2024年第2期58-64,共7页
结构性热桥的线传热系数ψ是在建筑热工设计中的一个关键参数,但设计规范对其阐述较为概括,因此,有必要对其做进一步解析,方能使工程师或研究人员更深刻地理解其内涵。结合相关规范标准,采用计算机节能设计软件分析模拟,对线传热系数取... 结构性热桥的线传热系数ψ是在建筑热工设计中的一个关键参数,但设计规范对其阐述较为概括,因此,有必要对其做进一步解析,方能使工程师或研究人员更深刻地理解其内涵。结合相关规范标准,采用计算机节能设计软件分析模拟,对线传热系数取值的算法及其合理性进行探讨。选取一个实际工程案例,通过对比窗洞口以及外墙空调机搁板两种主要线性热桥的取值变化,发现对于具有大量线性热桥的建筑,线传热系数的微小改变将对建筑的整体能耗产生不可忽视的影响,进而展示了该系数在建筑热工设计中所起到的重要作用,为工程设计中正确拟定线传热系数ψ的取值提供有价值的参考和借鉴。 展开更多
关键词 热桥 线传热系数 工程设计
下载PDF
寒冷地区热湿耦合下墙体热桥的模拟研究
20
作者 李会敏 王海涛 +1 位作者 魏家骅 李建 《节能》 2024年第6期10-13,共4页
在寒冷地区气候条件下,通过COMSOL Multiphysics模拟软件建立热湿耦合模型,对钢筋混凝土柱红砖砌体墙所形成柱墙角热桥进行模拟研究。结果表明,湿传递的作用比只有传热作用的墙体内表面温度低,在实际工况下不能忽略湿传递对建筑材料导... 在寒冷地区气候条件下,通过COMSOL Multiphysics模拟软件建立热湿耦合模型,对钢筋混凝土柱红砖砌体墙所形成柱墙角热桥进行模拟研究。结果表明,湿传递的作用比只有传热作用的墙体内表面温度低,在实际工况下不能忽略湿传递对建筑材料导热系数的影响。由于热桥的影响使围护结构的热通量增加19.6%,热桥的影响区域为距离最不利点0.4 m左右,在相同保温板厚度时,外保温比内保温墙体内表面温度高,保温效果更好。随着保温板厚度的增加,墙体内表温度升高,墙体内表面热通量降低。为了降低冬季房间供暖能耗,可以通过对热桥外保温来解决墙体结露现象。 展开更多
关键词 热湿耦合传递 热桥效应 露点温度 热湿模拟
下载PDF