This article explores the topic of fault diagnosis and maintenance strategies for instrument automation control systems,analyzing them through specific cases.The aim of this research is to improve the stability and re...This article explores the topic of fault diagnosis and maintenance strategies for instrument automation control systems,analyzing them through specific cases.The aim of this research is to improve the stability and reliability of the system by conducting a thorough investigation of faults and maintenance in instrument automation control systems.By doing so,this research hopes to provide a strong guarantee for the smooth progress of industrial production.展开更多
Influence produced by the heat effect at work of the laser instrument crystal of the semiconductor, the text designs a kind of temperature control system to the crystal of the laser instrument, using the thought and m...Influence produced by the heat effect at work of the laser instrument crystal of the semiconductor, the text designs a kind of temperature control system to the crystal of the laser instrument, using the thought and method of the classical control theory to analyze this temperature control system, and establishes mathematics model. According to mathematics model the text demonstrated the system at S field and time- area, and proposed optimizing basis to the total mark of proportion and differential parameter to con- troller PID, thus proposed a kind of temperature control scheme. And the thermostatically system is simulated by MATLAB.展开更多
Threshold decision is an important function of nuclear instrument control system based on physical parameters threshold decision. Because the conventional decision methods lack correlation with time and conditions, by...Threshold decision is an important function of nuclear instrument control system based on physical parameters threshold decision. Because the conventional decision methods lack correlation with time and conditions, by analyzing the existing methods, some optimized methods are adopted. Considering safety, those methods are improved in data processing algorithms, floating threshold with multiple values, association with specific working condition, etc. These measures im- prove the nuclear instrument control system in fault tolerance and fault diagnosis, especially, the shutdown number of nucle- ar power plant decreases.展开更多
A new concept called intelligent virtual control (IVC), which can be drivenby measuring functions, is put forward. This small 'intelligent measurement instrument unit (IMIU)',carrying with functions of instrum...A new concept called intelligent virtual control (IVC), which can be drivenby measuring functions, is put forward. This small 'intelligent measurement instrument unit (IMIU)',carrying with functions of instrument, consists of different types of intelligent virtualinstrument (IVI) through individual components together as building blocks and can be displayeddirectly on the computer screen. This is a new concept of measuring instrument, and also animportant breakthrough after virtual instrument (VI). Virtual control makes instrument resourcesobtain further exploitation. It brings about a fundamental change to the design and manufacturingmode. The instrument therefore, can not only be produced directly inside a PC, but the product isinvolved in the 'green product' system. So far, all the present digital instruments will grow to bereplaced by intelligent control with green characteristics.展开更多
BACKGROUND Magnetically controlled growing rods(MCGR) are a novel treatment option for early onset scoliosis(EOS). Although the complication profile with MCGR use has been reviewed, these reviews do not take into acco...BACKGROUND Magnetically controlled growing rods(MCGR) are a novel treatment option for early onset scoliosis(EOS). Although the complication profile with MCGR use has been reviewed, these reviews do not take into account important implants modifications, termed iterations, that were made due to early on postoperative complications is not well reported or understood.AIM To assess the effect of MCGR implant iterations on post-operative complications in EOS.METHODS A systematic review was performed to identify studies investigating MCGR specifically for the treatment of EOS, refined to those reporting the implant iteration, specifically the incorporation of the keeper plate to the implant design.Articles with mixed implant iteration usage were excluded. Complications following surgery were recorded as well as potential risk factors and compared between implant cohorts.RESULTS Although 20 articles were identified for inclusion, 5 included mixed implant iteration leaving a total of 271 patients identified through 15 clinical studies thatmet inclusion criteria. The average follow-up was 25.4-mo. Pre-keeper plate implants were utilized in 3 studies with a total of 49 patients. Overall, 115(42.4%)post-operative complications were identified, with 87% defined as major. The addition of the keeper plate significantly decreased the rate of post-operative complications per study(35.7% vs 80.6%, P = 0.036), and the rate of distraction failure(8.1% vs 40.8%, P = 0.02). Unplanned reoperation occurred in 69(26.7%)patients but was not different between implant iteration cohorts(25.5% without keeper plate vs 27.1% with keeper plate, P = 0.92).CONCLUSION MCGR for EOS has a cumulative complication rate of 42.4% but this is significantly reduced to 35.7% when reviewing only keeper-plate enabled implants. However, 25% of published articles included mixed implant iterations.Future studies should discern between implants iterations when reporting on the usage of MCGR for EOS.展开更多
The existence of linear quadratic optimal control of ship automatic steering instruments is studied. Firstly, the sufficient conditions for the quadratic integrability of the solutions of linear second order time-vari...The existence of linear quadratic optimal control of ship automatic steering instruments is studied. Firstly, the sufficient conditions for the quadratic integrability of the solutions of linear second order time-variant differential equations are developed. Secondly, the optimal control form of the ship automatic steering instrument is obtained by using the dynamic programming method, which guarantees a minimal ship sway range, during long-distance navigation, by using as little energy as possible. Finally, based on the above mentioned sufficient conditions, the conditions for the realization of optimal control are obtained, which provides a foundation for choosing the weighted coefficients for optimal control in engineering.展开更多
In this paper,the network reliability of an actual digital instrument and control system (DICS) network is analyzed by using GO-FLOW methodology (GFM).The evaluations of common-cause failure (CCF) and uncertainty are ...In this paper,the network reliability of an actual digital instrument and control system (DICS) network is analyzed by using GO-FLOW methodology (GFM).The evaluations of common-cause failure (CCF) and uncertainty are incorporated.Three significant CCF groups (real time servers,gateways,reactor protection system) and three typical time intervals (10 min,1 h,and 24 h) are selected in the analysis.It is concluded that the network contribution of CCF accounts for over 68% of the system failure probability.The result indicates that GFM is suitable for the network reliability analysis.展开更多
Objectives Most medical instruments are designed for diagnosis purpose but very few for clinical treatment. Our research aim is to design and develop a cardiovascular automatic feedback control instrument (CAFCI) fo...Objectives Most medical instruments are designed for diagnosis purpose but very few for clinical treatment. Our research aim is to design and develop a cardiovascular automatic feedback control instrument (CAFCI) for rescuing the critical patients with abnormal blood pressure. Methods The CAFCI was designed on the basis of abundant clinical experiences and on successful mathematic modeling of our blood pressure, pulmonary experimental data. The capillary wedge pressure, and rates of heart beat were measured and inputted into a computer and drugs were chosen by a doctor through a user-friendly interface with the computer. The responses to medication were rapidly acquired and feed back to the computer by automatic detection system in a close-loop system. every 7.5 sec in order to dosage The data were refreshed regulate the speed and of the medications that were given. Results The experimental results with ten dogs showed that the CAFCI system took samples promptly and accurately so that the targeted blood pressure could be reached reliably based on our input parameters and our designing requirements. Conclusions Since the dependability and accuracy of the CAFCI system are much superior to that of the traditional method, its clinical application to rescue the critical patient warrants evaluation in the future.展开更多
This paper aims to explain main ageing stressors and effects on instrumentation and control (I&C) components followed by ageing management strategies through developed design such as using freewheeling diode to el...This paper aims to explain main ageing stressors and effects on instrumentation and control (I&C) components followed by ageing management strategies through developed design such as using freewheeling diode to eliminate relays contact ageing due to inductive loads, or through traditional practices and new online monitoring where I&C components can be checked and assessed remotely while the plant is operating. It also includes some recommendations for obsolescence management for special I&C components like microcontrollers and programmable logic controllers (PLCs).展开更多
The article describes the digital instrumentation and control system for unit 5 & 6 of YangJiang NPP, involving the overall I & C (instrumentation and control) structure, the basic requirements and independent ver...The article describes the digital instrumentation and control system for unit 5 & 6 of YangJiang NPP, involving the overall I & C (instrumentation and control) structure, the basic requirements and independent verification and validation. Advanced I & C systems for YangJiang NPPs have to meet increasing demands for safety and availability. Additionally, the specific requirements coming from the nuclear qualification have to be fulfilled.展开更多
僵尸网络(Botnet)是一种从传统恶意代码形态进化而来的新型攻击方式,为攻击者提供了隐匿、灵活且高效的一对多命令与控制信道(Command and Control channel,C&C)机制,可以控制大量僵尸主机实现信息窃取、分布式拒绝服务攻击和垃圾...僵尸网络(Botnet)是一种从传统恶意代码形态进化而来的新型攻击方式,为攻击者提供了隐匿、灵活且高效的一对多命令与控制信道(Command and Control channel,C&C)机制,可以控制大量僵尸主机实现信息窃取、分布式拒绝服务攻击和垃圾邮件发送等攻击目的。该文提出一种与僵尸网络结构和C&C协议无关,不需要分析数据包的特征负载的僵尸网络检测方法。该方法首先使用预过滤规则对捕获的流量进行过滤,去掉与僵尸网络无关的流量;其次对过滤后的流量属性进行统计;接着使用基于X-means聚类的两步聚类算法对C&C信道的流量属性进行分析与聚类,从而达到对僵尸网络检测的目的。实验证明,该方法高效准确地把僵尸网络流量与其他正常网络流量区分,达到从实际网络中检测僵尸网络的要求,并且具有较低的误判率。展开更多
Abstract In this paper, a cascade acceleration feedback control (AFC) enhanced by a disturbance observa- tion and compensation (DOC) method is proposed to improve the tracking precision of telescope systems. Teles...Abstract In this paper, a cascade acceleration feedback control (AFC) enhanced by a disturbance observa- tion and compensation (DOC) method is proposed to improve the tracking precision of telescope systems. Telescope systems usually suffer some uncertain disturbances, such as wind load, nonlinear friction and other unknown disturbances. To ensure tracking precision, an acceleration feedback loop which can in- crease the stiffness of such a system is introduced. Moreover, to further improve the tracking precision, we introduce the DOC method which can accurately estimate the disturbance and compensate it. Furthermore, the analysis of tracking accuracy used by this method is proposed. Finally, a few comparative experimental results show that the proposed control method has excellent performance for reducing the tracking error of a telescope system.展开更多
Wide collection on the historic records of the climatic changes and flood events is performed in the Yangtze Delta. Man-Kendall (MK) method is applied to explore the changing trends of the time series of the flood dis...Wide collection on the historic records of the climatic changes and flood events is performed in the Yangtze Delta. Man-Kendall (MK) method is applied to explore the changing trends of the time series of the flood discharge and the maximum high summer temperature. The research results indicate that the flood magnitudes increased during the transition from the medieval warm interval into the early Little Ice Age. Fluctuating climate changes of the Little Ice Age characterized by arid climate events followed by the humid and cold climate conditions give rise to the frequent flood hazards. Low-lying terrain made the study region prone to the flood hazards, storm tide and typhoon. MK analysis reveals that the jumping point of the time series of the flood discharge changes occurred in the mid-1960s, that of the maximum summer temperature changes in the mid-1990s, and the exact jump point in 1993. The flood discharge changes are on negative trend before the 1990s, they are on positive tendency after the 1990s; the maximum high summer temperature changes are on negative trend before the 1990s and on positive tendency after the 1990s. These results indicate that the trend of flood discharge matches that of the maximum high summer temperature in the Yangtze Delta. The occurrence probability of the maximum high summer temperature will be increasing under the climatic warming scenario and which will in turn increase the occurrence probability of the flood events. More active solar action epochs and the higher sea surface temperature index (SST index) of the south Pacific Ocean area lying between 4 o N-4 o S and 150 o W-90 o W correspond to increased annual precipitation, flood discharge and occurrence frequency of floods in the Yangtze Delta. This is partly because the intensified solar activities and the higher SST index give rise to accelerated hydrological circulation from ocean surface to the continent, resulting in increased precipitation on the continent.展开更多
Servo pressure pulse testing equipment uses servo-hydraulic technology to build the model of hydraulic system. By improving measurement and control system, the equipment accomplishes signal acquisition, data processin...Servo pressure pulse testing equipment uses servo-hydraulic technology to build the model of hydraulic system. By improving measurement and control system, the equipment accomplishes signal acquisition, data processing and process con- trol. LabVIEW and programmable logic controller (PLC) are used to carry out the hardware configuration and software de- velopment. The system can communicate between LabVIEW and PLC by virtual instrumentation software architecture (VI- SA) and run automatically in accordance with setting commands. Therefore, accuracy and performance of the equipment are improved.展开更多
Recently, it has become clear that mild abnormal glucose tolerance increases the incidence of perinatal maternalinfant complications, and so the definition and diagnostic criteria of gestational diabetes mellitus(GDM)...Recently, it has become clear that mild abnormal glucose tolerance increases the incidence of perinatal maternalinfant complications, and so the definition and diagnostic criteria of gestational diabetes mellitus(GDM) have been changed. Therefore, in patients with GDM and pregnant women with diabetes mellitus, even stricter glycemic control than before is required to reduce the incidence of perinatal maternal-infant complications. Strict glycemic control cannot be attained without an indicator of glycemic control; this review proposes a reliable indicator. The gold standard indicator of glycemic control in patients with diabetes mellitus is hemoglobin A1c(Hb A1c); however, we have demonstrated that Hb A1 c does not reflect glycemic control accurately during pregnancy because of iron deficiency. It has also become clear that glycated albumin, another indicator of glycemic control, is not influenced by iron deficiency and therefore might be a better indicator of glycemic control in patients with GDM and pregnant women with diabetes mellitus. However, largepopulation epidemiological studies are necessary in order to confirm our proposal. Here, we outline the most recent findings about the indicators of glycemic control during pregnancy including fructosamine and 1,5-anhydroglucitol.展开更多
BACKGROUND: Hemodialysis (HD) patients are at high risk of infection by hepatitis B virus (HBV) or hepatitis C virus (HCV). The present study was designed to determine the impact of quality control measures on the pre...BACKGROUND: Hemodialysis (HD) patients are at high risk of infection by hepatitis B virus (HBV) or hepatitis C virus (HCV). The present study was designed to determine the impact of quality control measures on the prevention of transmission of blood-borne viruses. METHODS: A total of 6182 adult maintenance HD patients from all HD units in Zhejiang Province were recruited on January 1, 2007. The baseline demographic and clinical characteristics were recorded and all patients were followed up until death or survival at 4 years later. The Quality Control Standards of Hemodialysis were gradually implemented in HD units. The HBV or HCV seroconversion rates of the recruited patients were calculated and compared every year during the observation period. RESULTS: The prevalence of HBV was 8.3% at the beginning of the study, and 6.6% for HCV. With the implementation of the HD quality control measures, the HBV seroconversion rate tended to decrease year by year (χ 2 =6.620, P=0.085), and the HCV seroconversion rate decreased significantly (χ 2 =10.41, P=0.015). Compared with the data in 2007, the HBV seroconversion rate (χ 2 =4.204, P=0.040, relative risk ratio 0.393, 95% CI 0.156-0.991) and the HCV seroconversion rate (χ 2 =7.373, P=0.007, relative risk ratio 0.386, 95% CI 0.189-0.787) decreased significantly in 2010. CONCLUSION: Quality control measures for HD decreased the seroconversion rates of HBV or HCV in HD patients, showing that updated quality control measures reduce the risk for transmission of blood-borne viruses in the HD population.展开更多
Two sets of super-synchronization speed control assemblies for two 80 MVA motor-generator units have been developed successfully in order to satisfy the demand of the toroidal field system in the HL-2A tokamak. Based ...Two sets of super-synchronization speed control assemblies for two 80 MVA motor-generator units have been developed successfully in order to satisfy the demand of the toroidal field system in the HL-2A tokamak. Based on the three-phase logical no-circumfluence a.c./a.c. cycloconverter, the speeds of two 2500 kW double fed drive motors have been regulated by means of the vector control technology. The maximum operating speed of each motor- generator unit has been raised from 1488 rpm (revolutions per minute) to 1650 rpm and the released energy of each unit during a pulsed discharge can reach 500 MJ. As a result, the toroidal field system has the capacity to provide 2.8 tesla (T) in HL-2A experiments.展开更多
文摘This article explores the topic of fault diagnosis and maintenance strategies for instrument automation control systems,analyzing them through specific cases.The aim of this research is to improve the stability and reliability of the system by conducting a thorough investigation of faults and maintenance in instrument automation control systems.By doing so,this research hopes to provide a strong guarantee for the smooth progress of industrial production.
文摘Influence produced by the heat effect at work of the laser instrument crystal of the semiconductor, the text designs a kind of temperature control system to the crystal of the laser instrument, using the thought and method of the classical control theory to analyze this temperature control system, and establishes mathematics model. According to mathematics model the text demonstrated the system at S field and time- area, and proposed optimizing basis to the total mark of proportion and differential parameter to con- troller PID, thus proposed a kind of temperature control scheme. And the thermostatically system is simulated by MATLAB.
基金Research Project of Hunan Province Education Department(No.14C0972)
文摘Threshold decision is an important function of nuclear instrument control system based on physical parameters threshold decision. Because the conventional decision methods lack correlation with time and conditions, by analyzing the existing methods, some optimized methods are adopted. Considering safety, those methods are improved in data processing algorithms, floating threshold with multiple values, association with specific working condition, etc. These measures im- prove the nuclear instrument control system in fault tolerance and fault diagnosis, especially, the shutdown number of nucle- ar power plant decreases.
基金This project is supported by National Natural Science Foundation of China(No.50135050).
文摘A new concept called intelligent virtual control (IVC), which can be drivenby measuring functions, is put forward. This small 'intelligent measurement instrument unit (IMIU)',carrying with functions of instrument, consists of different types of intelligent virtualinstrument (IVI) through individual components together as building blocks and can be displayeddirectly on the computer screen. This is a new concept of measuring instrument, and also animportant breakthrough after virtual instrument (VI). Virtual control makes instrument resourcesobtain further exploitation. It brings about a fundamental change to the design and manufacturingmode. The instrument therefore, can not only be produced directly inside a PC, but the product isinvolved in the 'green product' system. So far, all the present digital instruments will grow to bereplaced by intelligent control with green characteristics.
文摘BACKGROUND Magnetically controlled growing rods(MCGR) are a novel treatment option for early onset scoliosis(EOS). Although the complication profile with MCGR use has been reviewed, these reviews do not take into account important implants modifications, termed iterations, that were made due to early on postoperative complications is not well reported or understood.AIM To assess the effect of MCGR implant iterations on post-operative complications in EOS.METHODS A systematic review was performed to identify studies investigating MCGR specifically for the treatment of EOS, refined to those reporting the implant iteration, specifically the incorporation of the keeper plate to the implant design.Articles with mixed implant iteration usage were excluded. Complications following surgery were recorded as well as potential risk factors and compared between implant cohorts.RESULTS Although 20 articles were identified for inclusion, 5 included mixed implant iteration leaving a total of 271 patients identified through 15 clinical studies thatmet inclusion criteria. The average follow-up was 25.4-mo. Pre-keeper plate implants were utilized in 3 studies with a total of 49 patients. Overall, 115(42.4%)post-operative complications were identified, with 87% defined as major. The addition of the keeper plate significantly decreased the rate of post-operative complications per study(35.7% vs 80.6%, P = 0.036), and the rate of distraction failure(8.1% vs 40.8%, P = 0.02). Unplanned reoperation occurred in 69(26.7%)patients but was not different between implant iteration cohorts(25.5% without keeper plate vs 27.1% with keeper plate, P = 0.92).CONCLUSION MCGR for EOS has a cumulative complication rate of 42.4% but this is significantly reduced to 35.7% when reviewing only keeper-plate enabled implants. However, 25% of published articles included mixed implant iterations.Future studies should discern between implants iterations when reporting on the usage of MCGR for EOS.
基金supported by National Nature Science Foundation of P.R.China(No.69974032).
文摘The existence of linear quadratic optimal control of ship automatic steering instruments is studied. Firstly, the sufficient conditions for the quadratic integrability of the solutions of linear second order time-variant differential equations are developed. Secondly, the optimal control form of the ship automatic steering instrument is obtained by using the dynamic programming method, which guarantees a minimal ship sway range, during long-distance navigation, by using as little energy as possible. Finally, based on the above mentioned sufficient conditions, the conditions for the realization of optimal control are obtained, which provides a foundation for choosing the weighted coefficients for optimal control in engineering.
基金Supported by Nuclear Safety Research Association and Tohoku University for Nuclear Researchers Exchange Program 2010National High Technology and Development Program ("863"Program)of China(No.2007AA041009)
文摘In this paper,the network reliability of an actual digital instrument and control system (DICS) network is analyzed by using GO-FLOW methodology (GFM).The evaluations of common-cause failure (CCF) and uncertainty are incorporated.Three significant CCF groups (real time servers,gateways,reactor protection system) and three typical time intervals (10 min,1 h,and 24 h) are selected in the analysis.It is concluded that the network contribution of CCF accounts for over 68% of the system failure probability.The result indicates that GFM is suitable for the network reliability analysis.
文摘Objectives Most medical instruments are designed for diagnosis purpose but very few for clinical treatment. Our research aim is to design and develop a cardiovascular automatic feedback control instrument (CAFCI) for rescuing the critical patients with abnormal blood pressure. Methods The CAFCI was designed on the basis of abundant clinical experiences and on successful mathematic modeling of our blood pressure, pulmonary experimental data. The capillary wedge pressure, and rates of heart beat were measured and inputted into a computer and drugs were chosen by a doctor through a user-friendly interface with the computer. The responses to medication were rapidly acquired and feed back to the computer by automatic detection system in a close-loop system. every 7.5 sec in order to dosage The data were refreshed regulate the speed and of the medications that were given. Results The experimental results with ten dogs showed that the CAFCI system took samples promptly and accurately so that the targeted blood pressure could be reached reliably based on our input parameters and our designing requirements. Conclusions Since the dependability and accuracy of the CAFCI system are much superior to that of the traditional method, its clinical application to rescue the critical patient warrants evaluation in the future.
文摘This paper aims to explain main ageing stressors and effects on instrumentation and control (I&C) components followed by ageing management strategies through developed design such as using freewheeling diode to eliminate relays contact ageing due to inductive loads, or through traditional practices and new online monitoring where I&C components can be checked and assessed remotely while the plant is operating. It also includes some recommendations for obsolescence management for special I&C components like microcontrollers and programmable logic controllers (PLCs).
文摘The article describes the digital instrumentation and control system for unit 5 & 6 of YangJiang NPP, involving the overall I & C (instrumentation and control) structure, the basic requirements and independent verification and validation. Advanced I & C systems for YangJiang NPPs have to meet increasing demands for safety and availability. Additionally, the specific requirements coming from the nuclear qualification have to be fulfilled.
文摘僵尸网络(Botnet)是一种从传统恶意代码形态进化而来的新型攻击方式,为攻击者提供了隐匿、灵活且高效的一对多命令与控制信道(Command and Control channel,C&C)机制,可以控制大量僵尸主机实现信息窃取、分布式拒绝服务攻击和垃圾邮件发送等攻击目的。该文提出一种与僵尸网络结构和C&C协议无关,不需要分析数据包的特征负载的僵尸网络检测方法。该方法首先使用预过滤规则对捕获的流量进行过滤,去掉与僵尸网络无关的流量;其次对过滤后的流量属性进行统计;接着使用基于X-means聚类的两步聚类算法对C&C信道的流量属性进行分析与聚类,从而达到对僵尸网络检测的目的。实验证明,该方法高效准确地把僵尸网络流量与其他正常网络流量区分,达到从实际网络中检测僵尸网络的要求,并且具有较低的误判率。
基金supported by the Quantum Communication Project,one of the Strategic Pilot Projects,Chinese Academy of Sciences
文摘Abstract In this paper, a cascade acceleration feedback control (AFC) enhanced by a disturbance observa- tion and compensation (DOC) method is proposed to improve the tracking precision of telescope systems. Telescope systems usually suffer some uncertain disturbances, such as wind load, nonlinear friction and other unknown disturbances. To ensure tracking precision, an acceleration feedback loop which can in- crease the stiffness of such a system is introduced. Moreover, to further improve the tracking precision, we introduce the DOC method which can accurately estimate the disturbance and compensate it. Furthermore, the analysis of tracking accuracy used by this method is proposed. Finally, a few comparative experimental results show that the proposed control method has excellent performance for reducing the tracking error of a telescope system.
基金Sino-France Cooperation Foundation (PRA E02-07) The key project of CAS+3 种基金No.KZCX3-SW-331 National Natural Science Foundation of China No.40271112 Foundation of Key Laboratory of Flood and Waterlogging and Wet Land Agriculture of Hubei Province
文摘Wide collection on the historic records of the climatic changes and flood events is performed in the Yangtze Delta. Man-Kendall (MK) method is applied to explore the changing trends of the time series of the flood discharge and the maximum high summer temperature. The research results indicate that the flood magnitudes increased during the transition from the medieval warm interval into the early Little Ice Age. Fluctuating climate changes of the Little Ice Age characterized by arid climate events followed by the humid and cold climate conditions give rise to the frequent flood hazards. Low-lying terrain made the study region prone to the flood hazards, storm tide and typhoon. MK analysis reveals that the jumping point of the time series of the flood discharge changes occurred in the mid-1960s, that of the maximum summer temperature changes in the mid-1990s, and the exact jump point in 1993. The flood discharge changes are on negative trend before the 1990s, they are on positive tendency after the 1990s; the maximum high summer temperature changes are on negative trend before the 1990s and on positive tendency after the 1990s. These results indicate that the trend of flood discharge matches that of the maximum high summer temperature in the Yangtze Delta. The occurrence probability of the maximum high summer temperature will be increasing under the climatic warming scenario and which will in turn increase the occurrence probability of the flood events. More active solar action epochs and the higher sea surface temperature index (SST index) of the south Pacific Ocean area lying between 4 o N-4 o S and 150 o W-90 o W correspond to increased annual precipitation, flood discharge and occurrence frequency of floods in the Yangtze Delta. This is partly because the intensified solar activities and the higher SST index give rise to accelerated hydrological circulation from ocean surface to the continent, resulting in increased precipitation on the continent.
基金High Level Talented Person Funded Project of Hebei Province(No.C2013005003)Excellent Experts for Going Abroad Training Program of Hebei Province(No.10215601D)
文摘Servo pressure pulse testing equipment uses servo-hydraulic technology to build the model of hydraulic system. By improving measurement and control system, the equipment accomplishes signal acquisition, data processing and process con- trol. LabVIEW and programmable logic controller (PLC) are used to carry out the hardware configuration and software de- velopment. The system can communicate between LabVIEW and PLC by virtual instrumentation software architecture (VI- SA) and run automatically in accordance with setting commands. Therefore, accuracy and performance of the equipment are improved.
基金Supported by National Natural Science Foundation of China,No.81302593,No.81271848 and No.81101589the Grant of Beijing Nova Program of China,No.Z121107002512071+1 种基金the National Key Basic Research Program of China,No.2009CB522507the National Grand Program on Key Infectious Disease,No.2009ZX10005-017 and No.2012ZX10002007
文摘AIM: To investigate the risk factors for liver-related mortality in chronic hepatitis C (CHC) patients.
文摘Recently, it has become clear that mild abnormal glucose tolerance increases the incidence of perinatal maternalinfant complications, and so the definition and diagnostic criteria of gestational diabetes mellitus(GDM) have been changed. Therefore, in patients with GDM and pregnant women with diabetes mellitus, even stricter glycemic control than before is required to reduce the incidence of perinatal maternal-infant complications. Strict glycemic control cannot be attained without an indicator of glycemic control; this review proposes a reliable indicator. The gold standard indicator of glycemic control in patients with diabetes mellitus is hemoglobin A1c(Hb A1c); however, we have demonstrated that Hb A1 c does not reflect glycemic control accurately during pregnancy because of iron deficiency. It has also become clear that glycated albumin, another indicator of glycemic control, is not influenced by iron deficiency and therefore might be a better indicator of glycemic control in patients with GDM and pregnant women with diabetes mellitus. However, largepopulation epidemiological studies are necessary in order to confirm our proposal. Here, we outline the most recent findings about the indicators of glycemic control during pregnancy including fructosamine and 1,5-anhydroglucitol.
基金supported by grants from Zhejiang Health Bureau (2008B073)Zhejiang Education Bureau (Y200909640)
文摘BACKGROUND: Hemodialysis (HD) patients are at high risk of infection by hepatitis B virus (HBV) or hepatitis C virus (HCV). The present study was designed to determine the impact of quality control measures on the prevention of transmission of blood-borne viruses. METHODS: A total of 6182 adult maintenance HD patients from all HD units in Zhejiang Province were recruited on January 1, 2007. The baseline demographic and clinical characteristics were recorded and all patients were followed up until death or survival at 4 years later. The Quality Control Standards of Hemodialysis were gradually implemented in HD units. The HBV or HCV seroconversion rates of the recruited patients were calculated and compared every year during the observation period. RESULTS: The prevalence of HBV was 8.3% at the beginning of the study, and 6.6% for HCV. With the implementation of the HD quality control measures, the HBV seroconversion rate tended to decrease year by year (χ 2 =6.620, P=0.085), and the HCV seroconversion rate decreased significantly (χ 2 =10.41, P=0.015). Compared with the data in 2007, the HBV seroconversion rate (χ 2 =4.204, P=0.040, relative risk ratio 0.393, 95% CI 0.156-0.991) and the HCV seroconversion rate (χ 2 =7.373, P=0.007, relative risk ratio 0.386, 95% CI 0.189-0.787) decreased significantly in 2010. CONCLUSION: Quality control measures for HD decreased the seroconversion rates of HBV or HCV in HD patients, showing that updated quality control measures reduce the risk for transmission of blood-borne viruses in the HD population.
基金the Tenth-Five-Year Nuclear Energy Development of the Commission of Science and TechnologyNational Defense Industry of the China National Nuclear Corporation
文摘Two sets of super-synchronization speed control assemblies for two 80 MVA motor-generator units have been developed successfully in order to satisfy the demand of the toroidal field system in the HL-2A tokamak. Based on the three-phase logical no-circumfluence a.c./a.c. cycloconverter, the speeds of two 2500 kW double fed drive motors have been regulated by means of the vector control technology. The maximum operating speed of each motor- generator unit has been raised from 1488 rpm (revolutions per minute) to 1650 rpm and the released energy of each unit during a pulsed discharge can reach 500 MJ. As a result, the toroidal field system has the capacity to provide 2.8 tesla (T) in HL-2A experiments.