Based on analyzing the induced signals from the double-grids of an ionization chamber, the electron-drift time between the two grids is determined and the electron-drift velocity is derived. A waveform digitizer is em...Based on analyzing the induced signals from the double-grids of an ionization chamber, the electron-drift time between the two grids is determined and the electron-drift velocity is derived. A waveform digitizer is employed to record pulses from the two grids of the ionization chamber. The electron-drift velocity is measured as a function of the reduced electric field E/p for eight different ratios of Ar+CH4 mixtures. By analyzing the experimental data of this study, self-consistency of experimental data is achieved, and formulae for calculating electron-drift velocity in any ratio of Ar+CH4 mixtures are obtained.展开更多
Beam dynamics and rf designs of a 104 MHz ladder type IH-RFQ (L-IH-RFQ) accelerator are finished at Peking University for the acceleration of 14C+ from 40 keV to 500 keV. As a specific feature, the output beam ener...Beam dynamics and rf designs of a 104 MHz ladder type IH-RFQ (L-IH-RFQ) accelerator are finished at Peking University for the acceleration of 14C+ from 40 keV to 500 keV. As a specific feature, the output beam energy spread is as low as 0.6% achieved with the internal discrete bunching method, which makes potential applications of RFQ feasible, such as accelerator mass spectrometry and ion implantation. Tolerances of the beam dynamics design are studied by means of changing the input beam parameters, and the results are quite satisfying. On the other hand, the L-IH-RFQ structure is employed, taking advantage of its mechanical stability and the absence of inter-electrode voltage asymmetry. Radio-frequency properties are studied and optimized for reducing power loss with Microwave Studio (MWS). Tuning of the field flatness and frequency is investigated in principle.展开更多
Accelerator mass spectrometry (AMS) is one of the most promising methods to detect minute amounts of 182Hf. However, the sensitivity of 5×10^-11 for ^182Hf/180Hf obtained previously by the AMS method at China I...Accelerator mass spectrometry (AMS) is one of the most promising methods to detect minute amounts of 182Hf. However, the sensitivity of 5×10^-11 for ^182Hf/180Hf obtained previously by the AMS method at China Institute of Atomic Energy (CIAE) cannot meet the requirement of some applications. We present some new improvements of measurement method for AMS measurement of 182Hf at the CIAE HI?13 tandem accelerator system. As a result, a sensitivity of 1.0×10^-11 for 182Hf/180Hf is achieved.展开更多
A 30-MeV femto-second electron linac is built at the Shanghai Institute of Applied Physics, which can produce high power, coherent THz undulator radiation. We report the experimental facility and measurement of the po...A 30-MeV femto-second electron linac is built at the Shanghai Institute of Applied Physics, which can produce high power, coherent THz undulator radiation. We report the experimental facility and measurement of the power, frequency spectrum. First experiments show the averaged power at THz to be about 20mW.展开更多
An experimental measurement of radiatively heated iron plasma transmission spectra was performed on Shenguang II laser facility. In the measurement, the self?emission spectrum, the backlighting spectrum, and the abso...An experimental measurement of radiatively heated iron plasma transmission spectra was performed on Shenguang II laser facility. In the measurement, the self?emission spectrum, the backlighting spectrum, and the absorption spectrum were imaged with a flat filed grating and recorded on a gated micro channel plate detector to obtain the time-resolved transmission spectra in the range 10-20 ? (approximately 0.6-1.3 keV). Experimental results are compared with the calculation results of an unsolved transition array (UTA) code. The time-dependent relative shift in the positions of the 2p-3d transmission array is interpreted in terms of the plasma temperature variations.展开更多
For heating the tokamak plasma effectively, the ion source must be capable of producing ions with high proton ratio. The proton ratio, which is found to be more than 65.6% at the ion current of 19.6A with the extracti...For heating the tokamak plasma effectively, the ion source must be capable of producing ions with high proton ratio. The proton ratio, which is found to be more than 65.6% at the ion current of 19.6A with the extraction voltage of 39.6 k V, is measured with an image spectrograph by Doppler shift effect of Balmer-α-radiation spectrum emitted from fast hydrogen particles. The tendency of proton ratio with the ion density in experiment is almost the same as the mode devised by Zhang et al. Okumura et al. only gave the affection of the plasma volume and ion loss area on the proton ratio, but the relationship between the ion density in chamber and the proton ratio was not presented. We give the relationship.展开更多
Specific activity of primordial radionuclides and associated radiation hazards due to 40K, 226Ra, and 232Th have been measured in backed red brick samples, collected from five highly populated areas of the North West ...Specific activity of primordial radionuclides and associated radiation hazards due to 40K, 226Ra, and 232Th have been measured in backed red brick samples, collected from five highly populated areas of the North West Frontier Province of Pakistan. For the detection, analysis and data acquisition, a high purity germanium detector was used. Associated external doses were calculated using a Monte Carlo neutron photon transport code. A theoretical model to determine the gamma dose rate at 1 m height from the floor, made of bricks, was employed for the calculation of mass attenuation coefficient and self-absorption in the floor for the gamma energies of these radionuclides and their progeny. Monte Carlo simulation shows that in this study the floor, having more than an effective thickness of 15 cm, contributes very little to the external gamma dose rate. The values of the external dose rate and annual effective dose are found to be much lower than the world average as well as from other countries of the world.展开更多
基金Supported by the National Natural Science Foundation of China under Grant Nos 10875006 and 10811120014, and China Nuclear Data Center.
文摘Based on analyzing the induced signals from the double-grids of an ionization chamber, the electron-drift time between the two grids is determined and the electron-drift velocity is derived. A waveform digitizer is employed to record pulses from the two grids of the ionization chamber. The electron-drift velocity is measured as a function of the reduced electric field E/p for eight different ratios of Ar+CH4 mixtures. By analyzing the experimental data of this study, self-consistency of experimental data is achieved, and formulae for calculating electron-drift velocity in any ratio of Ar+CH4 mixtures are obtained.
基金Supported by the National Natural Science Foundation of China under Grant No 10775009.
文摘Beam dynamics and rf designs of a 104 MHz ladder type IH-RFQ (L-IH-RFQ) accelerator are finished at Peking University for the acceleration of 14C+ from 40 keV to 500 keV. As a specific feature, the output beam energy spread is as low as 0.6% achieved with the internal discrete bunching method, which makes potential applications of RFQ feasible, such as accelerator mass spectrometry and ion implantation. Tolerances of the beam dynamics design are studied by means of changing the input beam parameters, and the results are quite satisfying. On the other hand, the L-IH-RFQ structure is employed, taking advantage of its mechanical stability and the absence of inter-electrode voltage asymmetry. Radio-frequency properties are studied and optimized for reducing power loss with Microwave Studio (MWS). Tuning of the field flatness and frequency is investigated in principle.
基金Supported by the Foundation of China Academy of Engineering Physics under Grant No 10576040, and the National Natural Science Foundation of China under Grant No 10705054.
文摘Accelerator mass spectrometry (AMS) is one of the most promising methods to detect minute amounts of 182Hf. However, the sensitivity of 5×10^-11 for ^182Hf/180Hf obtained previously by the AMS method at China Institute of Atomic Energy (CIAE) cannot meet the requirement of some applications. We present some new improvements of measurement method for AMS measurement of 182Hf at the CIAE HI?13 tandem accelerator system. As a result, a sensitivity of 1.0×10^-11 for 182Hf/180Hf is achieved.
文摘A 30-MeV femto-second electron linac is built at the Shanghai Institute of Applied Physics, which can produce high power, coherent THz undulator radiation. We report the experimental facility and measurement of the power, frequency spectrum. First experiments show the averaged power at THz to be about 20mW.
基金Supported by the National Natural Science Foundation of China under Grant Nos 10734140, 10874156 and 10875109.
文摘An experimental measurement of radiatively heated iron plasma transmission spectra was performed on Shenguang II laser facility. In the measurement, the self?emission spectrum, the backlighting spectrum, and the absorption spectrum were imaged with a flat filed grating and recorded on a gated micro channel plate detector to obtain the time-resolved transmission spectra in the range 10-20 ? (approximately 0.6-1.3 keV). Experimental results are compared with the calculation results of an unsolved transition array (UTA) code. The time-dependent relative shift in the positions of the 2p-3d transmission array is interpreted in terms of the plasma temperature variations.
文摘For heating the tokamak plasma effectively, the ion source must be capable of producing ions with high proton ratio. The proton ratio, which is found to be more than 65.6% at the ion current of 19.6A with the extraction voltage of 39.6 k V, is measured with an image spectrograph by Doppler shift effect of Balmer-α-radiation spectrum emitted from fast hydrogen particles. The tendency of proton ratio with the ion density in experiment is almost the same as the mode devised by Zhang et al. Okumura et al. only gave the affection of the plasma volume and ion loss area on the proton ratio, but the relationship between the ion density in chamber and the proton ratio was not presented. We give the relationship.
文摘Specific activity of primordial radionuclides and associated radiation hazards due to 40K, 226Ra, and 232Th have been measured in backed red brick samples, collected from five highly populated areas of the North West Frontier Province of Pakistan. For the detection, analysis and data acquisition, a high purity germanium detector was used. Associated external doses were calculated using a Monte Carlo neutron photon transport code. A theoretical model to determine the gamma dose rate at 1 m height from the floor, made of bricks, was employed for the calculation of mass attenuation coefficient and self-absorption in the floor for the gamma energies of these radionuclides and their progeny. Monte Carlo simulation shows that in this study the floor, having more than an effective thickness of 15 cm, contributes very little to the external gamma dose rate. The values of the external dose rate and annual effective dose are found to be much lower than the world average as well as from other countries of the world.