期刊文献+
共找到1,260篇文章
< 1 2 63 >
每页显示 20 50 100
Copper Release Kinetics and Ageing of Insulation Paper in Oil-Immersed Transformers 被引量:3
1
作者 Olena Sevastyanova Bogdan Pasalskiy Boris Zhmud 《Engineering(科研)》 2015年第8期514-529,共16页
The paper provides a general overview of chemical processes leading to the degradation of oil-paper insulation in oil-immersed electrical current transformers. Previous knowledge available in literature is complemente... The paper provides a general overview of chemical processes leading to the degradation of oil-paper insulation in oil-immersed electrical current transformers. Previous knowledge available in literature is complemented by new results placing a specific emphasis on the physicochemical factors which affect the copper release in the insulation oil and the oil oxidation kinetics. It is demonstrated that various ageing processes interact with each other, with one or another process dominating under specific conditions. Comprehensive but disjoint studies focusing on separate sub-processes may produce rather misleading results, and occasionally, lie behind rather irrelevant quality demands imposed on the insulating liquids. 展开更多
关键词 TRANSFORMER OIL insulating OIL COPPER CORROSION PAPER DEGRADATION ageing
下载PDF
Accelerated Aging Experiment and Remaining Lifetime Analysis of Insulation for CXF Type Cable on Vessels 被引量:4
2
作者 WANG Hexun JI Yulong +2 位作者 LIU Gaishi GUO Yang SUN Yuqing 《高电压技术》 EI CAS CSCD 北大核心 2013年第8期1886-1892,共7页
关键词 电缆绝缘层 老化实验 船用电缆 剩余寿命 XF型 寿命分析 船只 数学模型
下载PDF
DC Insulation Parameter Characteristics of XLPE in the Course of Its Aging
3
作者 WANGHong-xin CHENGShu-kang +2 位作者 WENXi-shan YAOHong-yu CHENYun-ping 《Wuhan University Journal of Natural Sciences》 EI CAS 2005年第2期421-425,共5页
This paper deals with the experimental study on the correlation betweeninsulation resistance (R) and direct current (DC) component (i_(de)) and corresponding aging degreeof insulation in the course of the aging within... This paper deals with the experimental study on the correlation betweeninsulation resistance (R) and direct current (DC) component (i_(de)) and corresponding aging degreeof insulation in the course of the aging within cross linked polyethylene (XLPE) insulation. Theaging tests were performed on a section of 10 kV transmission XLPE cable by means of water needlemethod, and _R was measured by DC voltage superimposed method, R and i_(de) were found to besignificantly dependent on the correspondingaging degree of insulation in the course of aging ofXLPE, and different kind of aging stage has different characteristics. Beside, there are generallysimilar regularity but different amplitude in the course of aging of XLPE insulation in differentelectrolyte, and the various electrochemical tree were found on the surface of aging XLPE cableimmersed in CuSO_4, solution. Therefore, according to the changing regularity of the DCcharacteristic parameters i. e. R and i_(de) within XLPE insulation judging the aging degree of XLPEinsulation will be an effective method. 展开更多
关键词 XLPE aging insulation resistance DC component
下载PDF
THE APPLICATION OF STATISTICAL PARAMETERS OF PHASE RESOLVED PD DISTRIBUTION TO AGING EXTENT ASSESSMENT OF LARGE GENERATOR INSULATION
4
作者 谢恒堃 乐波 +1 位作者 孙翔 宋建成 《Journal of Pharmaceutical Analysis》 SCIE CAS 2003年第1期1-5,65,共6页
Objective To investigate the characteristic parameters employed to describe the aging extent of stator insulation of large generator and study the aging laws. Methods Multi stress aging tests of model generator sta... Objective To investigate the characteristic parameters employed to describe the aging extent of stator insulation of large generator and study the aging laws. Methods Multi stress aging tests of model generator stator bar specimens were performed and PD measurements were conducted using digital PD detector with frequency range from 40?kHz to 400?kHz at different aging stage. Results From the test results of model specimens it was found that the skewness of phase resolved PD distribution might be taken as the characterization parameters for aging extent assessment of generator insulation. Furthermore, the measurement results of actual generator stator bars showed that the method based on statistical parameters of PD distributions are prospective for aging extent assessment and residual lifetime estimation of large generator insulation. Conclusion Statistical parameters of phase resolved PD distribution was proposed for aging extent assessment of large generator insulation. 展开更多
关键词 partial discharge statistical parameters stator insulation multi stress aging
下载PDF
Insulation Diagnosis of Service Aged XLPE Power Cables Using Statistical Analysis and Fuzzy Inference 被引量:1
5
作者 LIU Fei JIANG Pingkai +2 位作者 LEI Qingquan ZHANG Li SU Wenqun 《高电压技术》 EI CAS CSCD 北大核心 2013年第8期1932-1940,共9页
Cables that have been in service for over 20 years in Shanghai, a city with abundant surface water, failed more frequently and induced different cable accidents. This necessitates researches on the insulation aging st... Cables that have been in service for over 20 years in Shanghai, a city with abundant surface water, failed more frequently and induced different cable accidents. This necessitates researches on the insulation aging state of cables working in special circumstances. We performed multi-parameter tests with samples from about 300 cable lines in Shanghai. The tests included water tree investigation, tensile test, dielectric spectroscopy test, thermogravimetric analysis (TGA), fourier transform infrared spectroscopy (FTIR), and electrical aging test. Then, we carried out regression analysis between every two test parameters. Moreover, through two-sample t-Test and analysis of va- riance (ANOVA) of each test parameter, we analyzed the influences of cable-laying method and sampling section on the degradation of cable insulation respectively. Furthermore, the test parameters which have strong correlation in the regression analysis or significant differ- ences in the t-Test or ANOVA analysis were determined to be the ones identifying the XLPE cable insulation aging state. The thresholds for distinguishing insulation aging states had been also obtained with the aid of statistical analysis and fuzzy clustering. Based on the fuzzy in- ference, we established a cable insulation aging diagnosis model using the intensity transfer method. The results of regression analysis indicate that the degradation of cable insulation accelerates as the degree of in-service aging increases. This validates the rule that the in- crease of microscopic imperfections in solid material enhances the dielectric breakdown strength. The results of the two-sample t-Test and the ANOVA indicate that the direct-buried cables are more sensitive to insulation degradation than duct cables. This confirms that the tensile strength and breakdown strength are reliable functional parameters in cable insulation evaluations. A case study further indicates that the proposed diagnosis model based on the fuzzy inference can reflect the comprehensive aging state of cable insulation well, and that the cable service time has no correlation with the insulation aging state. 展开更多
关键词 交联聚乙烯绝缘电力电缆 模糊推理 统计分析 诊断服务 傅立叶变换红外光谱 电缆绝缘层 老化状态 电击穿强度
下载PDF
Comparative Evaluation of the Thermal Aging of Solid Insulation in Mineral Oil and Methyl Ester of Palm Kernel Oil
6
作者 Gerard Ombick Boyekong Ghislain Mengata Mengounou Adolphe Moukengue Imano 《Journal of Power and Energy Engineering》 2021年第5期166-183,共18页
The purpose of this work is to determine the impact of thermal aging on the dielectric and physicochemical properties of the oil/paper mixed insulation. We performed a comparative analysis of dielectric paper dipped i... The purpose of this work is to determine the impact of thermal aging on the dielectric and physicochemical properties of the oil/paper mixed insulation. We performed a comparative analysis of dielectric paper dipped in two cooling fluids: palm kernel oil methyl ester (MEPKO) and mineral oil (MO). Two types of dielectric paper were used: Thermally Upgraded Kraft paper (TUK) and Nomex-910 paper (NP-910). An accelerated aging test was realized at 110<span style="white-space:nowrap;">°</span>C during a total of 96 hours. Samples of oil and paper were collected after 0, 48, 72 and 96 hours for analyses purposes. The analyses performed included the measurement of the Breakdown voltage (BDV) of the dielectric papers, the Total Acid Number (TAN) and the Decay Dissolved Products (DDP) of the liquid dielectrics. The BDV of NP-910 is greater than the BDV of TUK. Concerning the type of oil, the BDV of dielectric papers impregnated with MEPKO is greater than the BDV of similar papers impregnated with MO, indicating a better preservation of paper when dipped in methyl esters. The analyses of TAN and DDP revealed that Nomex-910 improves the oxidation stability of MO, but reduces the oxidation stability of MEPKO. These results prove that methyl esters can be used as a substitute to replace mineral oils in power transformers. Furthermore, they show that NP can be used mainly in areas of transformer where solid insulation is subjected to high thermal and electrical stress, and TUK other places where solid insulation is required. Such combination could assure money savings and a better preservation of the oil viscosity. 展开更多
关键词 Oil/Paper Mixed insulation Methyl Ester Thermal aging Breakdown Voltage Oxidation Stability
下载PDF
Aging Effect on Characteristics of Oil Impregnated Insulation Paper for Power Transformers
7
作者 Loai S. Nasrat Nesrine Kassem Nadia Shukry 《Engineering(科研)》 2013年第1期1-7,共7页
This paper deals with experimental investigations of the electrical and physical properties of oil impregnated insulation paper for power transformers at different temperatures. The ac breakdown voltage, tensile stren... This paper deals with experimental investigations of the electrical and physical properties of oil impregnated insulation paper for power transformers at different temperatures. The ac breakdown voltage, tensile strength and water content of insulation papers impregnated in mineral oil for different time periods were investigated. The effect of insulation paper thickness on the electrical and mechanical properties has also been studied. The results showed that the breakdown voltage and the tensile strength decreased with increasing the time of immersion of insulation paper in oil at room temperature, at 5℃ and at -12℃. Also, the thermal aging effect on the characteristic of insulation paper has been studied. It was found that high temperatures affect the breakdown voltage and the tensile strength to a great extent. 展开更多
关键词 insulation Paper Power TRANSFORMERS aging BREAKDOWN Voltage TENSILE Strength Water Content
下载PDF
(Ag,Cu)/TiO_(2)汽车玻璃隔热膜的制备与表征
8
作者 王宁 时方晓 《广州化工》 CAS 2024年第7期69-72,共4页
利用磁控溅射技术制备由金属(Ag,Cu)膜、介质层TiO_(2)膜组成的双层汽车玻璃隔热膜样品。利用单因素分析法考察了溅射时间、溅射功率和Ar溅射流量三个因素对(Ag,Cu)/TiO_(2)汽车玻璃隔热膜透光隔热性能的影响。实验结果表明,在在本底真... 利用磁控溅射技术制备由金属(Ag,Cu)膜、介质层TiO_(2)膜组成的双层汽车玻璃隔热膜样品。利用单因素分析法考察了溅射时间、溅射功率和Ar溅射流量三个因素对(Ag,Cu)/TiO_(2)汽车玻璃隔热膜透光隔热性能的影响。实验结果表明,在在本底真空度3×10^(-3) Pa,溅射气压2.1 Pa条件下,靶基距均为70 mm时,金属(Ag,Cu)膜溅射时间18 s,溅射功率80 W,Ar溅射流量20 sccm;介质层TiO_(2)膜溅射时间50 min,溅射功率115 W,溅射流量25 sccm时,(Ag,Cu)/TiO_(2)汽车玻璃隔热膜的透光隔热性能最佳。 展开更多
关键词 (ag Cu)/TiO_(2)膜 汽车玻璃 隔热性能 透光率
下载PDF
Comprehensive evaluation of the transformer oil-paper insulation state based on RF-combination weighting and an improved TOPSIS method 被引量:7
9
作者 Fugen Song Shichao Tong 《Global Energy Interconnection》 EI CAS CSCD 2022年第6期654-665,共12页
The accurate identification of the oil-paper insulation state of a transformer is crucial for most maintenance strategies.This paper presents a multi-feature comprehensive evaluation model based on combination weighti... The accurate identification of the oil-paper insulation state of a transformer is crucial for most maintenance strategies.This paper presents a multi-feature comprehensive evaluation model based on combination weighting and an improved technique for order of preference by similarity to ideal solution(TOPSIS)method to perform an objective and scientific evaluation of the transformer oil-paper insulation state.Firstly,multiple aging features are extracted from the recovery voltage polarization spectrum and the extended Debye equivalent circuit owing to the limitations of using a single feature for evaluation.A standard evaluation index system is then established by using the collected time-domain dielectric spectrum data.Secondly,this study implements the per-unit value concept to integrate the dimension of the index matrix and calculates the objective weight by using the random forest algorithm.Furthermore,it combines the weighting model to overcome the drawbacks of the single weighting method by using the indicators and considering the subjective experience of experts and the random forest algorithm.Lastly,the enhanced TOPSIS approach is used to determine the insulation quality of an oil-paper transformer.A verification example demonstrates that the evaluation model developed in this study can efficiently and accurately diagnose the insulation status of transformers.Essentially,this study presents a novel approach for the assessment of transformer oil-paper insulation. 展开更多
关键词 Combined weight method Random forest algorithm insulation aging assessment Oil-paper insulation Time-domain eigenvalue
下载PDF
A New Method for the Aging Evaluation of Oil-Paper Insulation Using η-Butanol and Methanol
10
作者 Jianyi Wang Yuanxiang Zhou +3 位作者 Jun Liu Zhaowei Wang Song Bai Jiayu Lu 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2024年第2期717-726,共10页
To improve the accuracy and efficiency of the aging life prediction and assessment of transformer oil-paper insulation,and to make up for the deficiencies of traditional characterizers,such as 2-furfural,carbon monoxi... To improve the accuracy and efficiency of the aging life prediction and assessment of transformer oil-paper insulation,and to make up for the deficiencies of traditional characterizers,such as 2-furfural,carbon monoxide,and carbon dioxide,a method for the simultaneous determination of methanol,ethanol,n−propanol,and η-butanol in oil with a single injection is established by headspace-gas chromatography-mass spectrometry.The measured results show that the determination limits of the four alcohol characterizers can be controlled to 10μg/kg level.Based on this method,the change patterns of the above four alcohols with thermal aging time and degree of polymerization are obtained through thermal aging experimental research.Ethanol,η-propanol,and η-butanol in oil indicate nearly linear correlations with thermal aging time and degree of polymerization,similar to that of methanol.By analyzing 52 sets of measured data of 500 kV EHV transformers in operation,η-butanol is found to have excellent performance,and a new method to evaluate the aging state of oil-paper insulation employing η-butanol and methanol is proposed along with the aging attention value model.The measured data of 500 kV EHV transformers in operation indicate that the combination of η-butanol and methanol as the preferred characterizers can effectively compensate for the shortcoming of traditional characterizers in the early stages of aging,and the feasibility of the method is verified.Two possible pathways for the generation of η-butanol by cellulose cleavage during the aging of oil-paper are proposed from the chemical structure of cellulose. 展开更多
关键词 aging characterization determination method METHANOL η-butanol oil-paper insulation 500 kV transformers
原文传递
Online Loss Parameters Diagnosis Device Development of Power Cable Insulation
11
作者 Jie Chen Chenying Li +2 位作者 Libin Hu Jingying Cao Xiao Tan 《Energy and Power Engineering》 2017年第4期216-223,共8页
In southern China, power cable lines often running in water, and the state of XLPE insulation is difficult to detection effectively. This paper studied loss parameters online diagnosis technology of power cable insula... In southern China, power cable lines often running in water, and the state of XLPE insulation is difficult to detection effectively. This paper studied loss parameters online diagnosis technology of power cable insulation. An online loss parameters diagnosis device was development, which consists of current comparator, voltage controlled current source (VCCS), standard capacitor, GPRS wireless transmission system, control system and the data processing unit. 108 cables were detected using this device, and it was found out that one cable appeared to middle aging and eight cables appeared to slight aging. The butterfly water trees were observed in middle aging cable, which prove the effectiveness of online testing in the loss current measurement. 展开更多
关键词 LOSS Parameters Power CABLE insulation Onlinetesting aging
下载PDF
Fractal Dimension Analysis Based Aging State Assessment of Insulating Paper with Surface Microscopic Images
12
作者 Shuaibing Li Jiaqi Cui Yongqiang Kang 《Computer Modeling in Engineering & Sciences》 SCIE EI 2022年第5期1083-1099,共17页
The insulating paper of the transformer is affected by many factors during the operation,meanwhile,the surface texture of the paper is easy to change.To explore the relationship between the aging state and surface tex... The insulating paper of the transformer is affected by many factors during the operation,meanwhile,the surface texture of the paper is easy to change.To explore the relationship between the aging state and surface texture change of insulating paper,firstly,the thermal aging experiment of insulating paper is carried out,and the insulating paper samples with different aging times are obtained.After then,the images of the aged insulating paper samples are collected and pre-processed.The pre-processing effect is verified by constructing and calculating the gray surface of the sample.Secondly,the texture features of the insulating paper image are extracted by box dimension and multifractal spectrum.Based on that,the extreme learning machine(ELM)is taken as the classification tool with texture features and aging time as the input and output,to train the algorithm and construct the corresponding relationship between the texture feature and the aging time.After then,the insulating paper with unknown aging time is predicted with a trained ELMalgorithm.The numerical test results show that the texture features extracted from the fractal dimension of the micro image can effectively characterize the aging state of insulating paper,the average accuracy can reach 91.6%.It proves that the fractal dimension theory can be utilized for assessing the aging state of insulating paper for onsite applications. 展开更多
关键词 insulating paper aging state fractal dimension box dimension multifractal spectrum
下载PDF
Space Charge Characteristics of Oil-paper Insulation with New Paper and Aged Oil 被引量:1
13
作者 MU Haibao WANG Da +4 位作者 WANG Shiqiang TIAN Jie LI Yuan WEI Yanhui ZHANG Guanjun 《高电压技术》 EI CAS CSCD 北大核心 2013年第8期1865-1872,共8页
Oil-paper compound insulation has been widely used in power transformers for quite a long time because of its good performances. The insulation gradually degrades under combined thermal, electrical and chemical stress... Oil-paper compound insulation has been widely used in power transformers for quite a long time because of its good performances. The insulation gradually degrades under combined thermal, electrical and chemical stresses during routine operations, mainly because of space charges inside. This work investigated the space charge characteristics in oil-paper insulation under oil aging circumstance. New trans- former oil samples are thermally aged to obtain different aging states, and their physical and chemical properties are analyzed. New Kraft papers are dried in vacuum and fully immersed in these different aged oil samples, and three kinds of oil-paper samples are obtained. We use the pulsed electro-acoustic (PEA) method to measure space charge under both DC voltage-on and voltage-off conditions at room temperature. The effect of oil aging state on characteristics of space charge injection, accumulation, and decay is analyzed and discussed. The results show that comparing with the DC voltage-off condition, more charges are injected into samples at the interface of electrode and dielectric when DC voltage is on. When the oil-aged state gets worse, more charges are induced at both cathode and anode, more space charges are accumulated in the bulk, the area of negative charges is larger, and local electric field is distorted more seriously. Moreover, for the voltage-off condition, aged oil is good for space charge decay, and trapped positive space charges decay faster than trapped negative charges. 展开更多
关键词 空间电荷 油纸绝缘 电荷特性 老年 老化状态 直流电压 衰减特性 电荷积累
下载PDF
Aging Characteristics and Influencing Factors of the Sheds of Composite Insulators in Karst Regions of China
14
作者 Wei Zhao Miao Jiang +1 位作者 Jun Dong Lee Li 《Energy Engineering》 EI 2021年第6期1755-1766,共12页
In recent years,more and more high-voltage overhead transmission lines were built passing through the karst regions in southwestern China.This type of special landform seems to have an adverse effect on the aging of t... In recent years,more and more high-voltage overhead transmission lines were built passing through the karst regions in southwestern China.This type of special landform seems to have an adverse effect on the aging of the sheds of the line suspension composite insulators,which may lead to unexpected flashover and line tripping.In order to find out the particularity of the aging characteristics of insulators operating in the karst regions,samples in operation were selected from both the karst regions and the flatlands.Hydrophobicity,amount of surface contamination,and contaminant composition of the sheds were studied,then a comparison of performance between the two was made,and the possible influencing factors that cause such differences were discussed.The results show that the overall aging of the sheds of the composite insulators operating at the karst regions is more aggravated,which is caused by the combined influence of factors including the special topography,climate,and pollution in the area.The strong wind crossing the col will bring about the mutual scraping on the edges and stress concentration at the root of the sheds,leaving scratches and root cracks;the infiltration from these rupture of acid liquid,if any,will accelerate the aging and corroding of the internal silicone rubber material;moreover,the carbonates enriched on the surface of the sheds will gradually transform into more corrosive sulfates in an acidic environment,leading to further deterioration and chalking of the sheds of the insulators.The research work in this paper can provide guidance for the current operation and maintenance of composite insulators in the karst areas,as well as having important reference values for the layout design and insulation configuration of transmission lines to be built across karst landforms in the future. 展开更多
关键词 Composite insulator silicone rubber aging characteristics karst region CONTAMINATION CARBONATE
下载PDF
ING1基因沉默后通过抑制Caspase 2调节胃腺癌AGS细胞凋亡 被引量:1
15
作者 何向民 娄毅 +1 位作者 宋清斌 李建华 《中国肿瘤临床》 CAS CSCD 北大核心 2012年第17期1273-1276,共4页
目的:探讨RNA干扰沉默ING1基因表达对胃腺癌细胞AGS细胞凋亡的影响机制。方法:将体外合成的ING1基因特异性的siRNA利用脂质体2 000转染到胃腺癌细胞AGS,应用流式细胞技术和TUNEL技术检测ING1基因表达沉默对AGS细胞凋亡的影响应用荧光定... 目的:探讨RNA干扰沉默ING1基因表达对胃腺癌细胞AGS细胞凋亡的影响机制。方法:将体外合成的ING1基因特异性的siRNA利用脂质体2 000转染到胃腺癌细胞AGS,应用流式细胞技术和TUNEL技术检测ING1基因表达沉默对AGS细胞凋亡的影响应用荧光定量PCR技术和Western blot技术检测转染后40 hAGS细胞中ING1、Caspase 2和Caspase 3的表达。结果:转染后40 h,体外合成的siRNA对AGS细胞的ING1表达抑制作用明显。转染前凋亡率为(11.06±0.97)%,转染40 h后凋亡率为(6.70±0.41)%,转染前后凋亡率的改变差异有统计学意义(P<0.05)。转染后40 h AGS细胞中ING1、Caspase 2和Caspase 3的mRNA相对表达分别为0.170 7±0.06,0.125±0.03和0.999±0.10。转染后40 hAGS细胞中ING1、Caspase 2和Caspase 3的蛋白质水平改变的趋势与mRNA水平一致。结论:RNA干扰沉默ING1基因表达后,AGS细胞中Caspase 2表达明显下调,ING1基因沉默后通过抑制Caspase 2调节胃腺癌细胞AGS细胞凋亡。 展开更多
关键词 RNA干扰agS细胞ing1凋亡Caspase
下载PDF
Electrical Aging Phenomena of Power Cables Aged by Switching Impulses 被引量:3
16
作者 L. Cao A. Zanwar S. Grzybowski 《高电压技术》 EI CAS CSCD 北大核心 2013年第8期1911-1918,共8页
Due to the insufficient information regarding the aging phenomenon of cables caused by switching impulses, we aged 15 kV XLPE and EPR cable samples by 10 000 switching impulses in experiments and tested them. Plus in ... Due to the insufficient information regarding the aging phenomenon of cables caused by switching impulses, we aged 15 kV XLPE and EPR cable samples by 10 000 switching impulses in experiments and tested them. Plus in order to compare the aging phenome- non under multi-stress conditions, additional EPR cable samples were aged by rated AC voltage and current with switching impulses superimposed. We used measurements of partial discharge parameters to monitor the cables’ conditions during their aging process, and the AC breakdown voltages measurement to evaluate the cables after aging. Moreover, the Fourier transform infrared (FTIR) spectroscopy measurements revealed the changes of insulation materials after aging. The measurement results confirm that the accelerated aging of cable samples had taken place. The impacts of each individual aging factor are shown through the selected measurements and comparison. The study also helps to assess the reliability of the XLPE and EPR cables under similar condition while serving in power systems. 展开更多
关键词 老化现象 开关脉冲 交联聚乙烯电缆 电源线 交联聚乙烯绝缘 电力系统可靠性 电气 交流击穿电压
下载PDF
Application of time-temperature superposition method in thermal aging life prediction of shipboard cables
17
作者 邓文东 CHEN Yi-yuan 《Journal of Chongqing University》 CAS 2014年第4期142-150,共9页
The life of shipboard cables will decrease due to the complex aging processes. In terms of the safety perspective, remaining life prediction of the cable is essential to maintain a reliable operation. In this paper, f... The life of shipboard cables will decrease due to the complex aging processes. In terms of the safety perspective, remaining life prediction of the cable is essential to maintain a reliable operation. In this paper, firstly, based on Arrhenius equation, residual life of new styrene-butadiene cable is calculated; result indicates that the degradation rate which changes with time is proportional to thermal temperature. Then second order dynamic model is adopted into the residual life prediction, combined with the time-temperature superposition method(TTSP), and a new residual life model is proposed. According to the accelerated thermal aging experiment data and Arrhenius equation, TTSP method demonstrates to be an efficient way for life prediction, and life at normal temperature can be estimated by this model. In order to monitor the state of styrene-butadiene cable more accurately, an improved residual life model based on equivalent environment temperature of cable is proposed, and life of cable under real operation is analyzed. Result indicates that this model is credible and reliable, and it provides an important theoretical base for residual life of cables. 展开更多
关键词 insulated cable thermal aging Arrhenius equation TTSP residual life
下载PDF
Influence of Vegetable Oil on the Thermal Aging Rate of Kraft Paper and its Mechanism 被引量:4
18
作者 YANG Lijun DENG Bangfei +2 位作者 LIAO Ruijin SUN Caixin ZHU Mengzhao 《高电压技术》 EI CAS CSCD 北大核心 2012年第8期2059-2067,共9页
关键词 局部放电 射频信号 放电量 高电压技术
下载PDF
Improvement on Condition Assessment Model for Oil-paper Insulation 被引量:1
19
作者 LA Yuan SHI Xuetao +4 位作者 CAO Wen HE Baosheng KE Chunjun WU Kai LONG Hongyu 《高电压技术》 EI CAS CSCD 北大核心 2013年第8期1974-1980,共7页
Identification of the aging condition and the failure probability of oil-paper insulation in transformer is important for improving the reliability of electric power transmission system and applying life cycle cost (L... Identification of the aging condition and the failure probability of oil-paper insulation in transformer is important for improving the reliability of electric power transmission system and applying life cycle cost (LCC) management to electrical equipment. Based on data obtained in a series of multi-accelerated-aging experiments, two approaches for calculating failure probability of oil-paper insulation were compared in aspects of degree of polymerization (DP) and condition ranking. In the experiments, mineral oil and cellulose paper are sub- jected to electrical and thermal stresses, and several parameters, including dissolved gases’ volume fraction, furfural content, moisture content, and degree of polymerization, are measured after the aging process. Results show that weight of carbon oxide, which has a close relationship with cellulose paper degradation, is much higher in DP model than in condition ranking model. Moreover, it is concluded that DP model is more practically accurate than condition ranking model, because aging of cellulose paper rather than mineral oil is the key and critical factor of oil-paper insulation aging. 展开更多
关键词 油纸绝缘 评估模型 绝缘状态 老化实验 寿命周期成本 电力传输系统 失效概率 纤维素
下载PDF
Intelligent Diagnostic Method for Ageing Analysis of Transformer
20
作者 Anil Kumar Kori Arvind Kumar Sharma Ashok Kumar Singh Bhadoriya 《Energy and Power Engineering》 2012年第2期53-58,共6页
The fuzzy method is proposed for ageing analysis of transformer. The fuzzy controller is used for various input and one output, strictly depends on the number of membership function and there rule base and the type of... The fuzzy method is proposed for ageing analysis of transformer. The fuzzy controller is used for various input and one output, strictly depends on the number of membership function and there rule base and the type of the defuzzification method. The ageing of transformers is influenced by short term and long term over loads, number and intensity of short circuits, incidence of lightning, and internal faults. The recent development of various techniques for detecting the incipient fault conditions have been improved to some extent;the life expectancy of transformers by resorting to corrective actions in time. The ageing behavior is likely to be different for different types of transformers. The life span of the transformer, thus depends initially on the design and quality of manufacture and later on service conditions and maintenance standard, these factors vary considerably and affect the useful span of service life which therefore needs to be taken into account for residual life assessment. During the natural ageing of transformers, the insulation of winding deteriorates. Cellulose insulation degrades due to heating or electrical breakdown which is dissolved in oil. Hence, the chemical analysis of the Transformer oil gives evidence of changes that are taking place in the winding insulation during operation. Deterioration in transformer cellulose decreases both its electrical and mechanical strength. In this paper a novel fuzzy based algorithm has been implemented on three samples of power transformer oil. 展开更多
关键词 TRANSFORMER Oil Paper insulation Electrical BREAKDOWN ageing ANALYSIS Fuzzy LOGIC CONTROLLER
下载PDF
上一页 1 2 63 下一页 到第
使用帮助 返回顶部