A novel thickness measurement method for surface insulation coating of silicon steel based on NIR spectrometry is explored.The NIR spectra of insulation coating of silicon steel were collected by acousto-optic tunable...A novel thickness measurement method for surface insulation coating of silicon steel based on NIR spectrometry is explored.The NIR spectra of insulation coating of silicon steel were collected by acousto-optic tunable filter(AOTF) NIR spectrometer.To make full use of the effective information of NIR spectral data,discrete binary particle swarm optimization(DBPSO) algorithm was used to select the optimal wavelength variates.The new spectral data,composed of absorbance at selected wavelengths,were used to create the thickness quantitative analysis model by kernel partial least squares(KPLS) algorithm coupled with Boosting.The results of contrast experiments showed that the Boosting-KPLS model could efficiently improve the analysis accuracy and speed.It indicates that Boosting-KPLS is a more accurate and robust analysis method than KPLS for NIR spectral analysis.The maximal and minimal absolute error of 30 testing samples is respectively-0.02 μm and 0.19 μm,and the maximal relative error is 14.23%.These analysis results completely meet the practical measurement need.展开更多
The in-situ measurement of sound reflection and airborne sound insulation characteristics of a noise barrier in Europe are currently performed following the CEN/TS 1793-5 European standard guidelines (last revision pu...The in-situ measurement of sound reflection and airborne sound insulation characteristics of a noise barrier in Europe are currently performed following the CEN/TS 1793-5 European standard guidelines (last revision published in 2003 [1]). After some years a large number of barriers measured, the original method has been significantly enhanced and validated in the frame of the EU funded QUIESST project, WP3 [2]. The sound reflection measurement method has been improved using a square 9-microphone grid not rigidly connected to the loudspeaker, an optimized alignment algorithm of free-field and reflected impulse responses, including fractional step shifts and least squares estimation of the best relative position, and a correction for geometrical divergence and sound source directivity. Each single measurement is then validated by means of the Reduction Factor calculation. The airborne sound insulation measurement method has not been markedly changed since 2003, because the procedure is robust and easily applicable as it is, but some problems may still be encountered when measuring highly insulating noise barriers, due to a poor signal to noise ratio of the transmitted impulse response. In those cases it is difficult to realize just after the measurement whether the obtained data are valid or not. A method, applicable on site, to overcome this problem is described here. It is based on the Signal to Noise Ratio estimation of critical parts of the acquired impulse responses and gives a strong validation criterion.展开更多
Ash dense(non-soluble sediment density,NSDD) is attached to the insulator surface material that can't dissolve in water,it is divided by the result of surface area and used for quantitative content of insulator su...Ash dense(non-soluble sediment density,NSDD) is attached to the insulator surface material that can't dissolve in water,it is divided by the result of surface area and used for quantitative content of insulator surface non-soluble residues. Based on high voltage measurement,surface of outer insulation of ash can be used for the product line insulator pollution situation and determine whether it is able to withstand a variety of adverse factors. This paper proposes a method based on BH1750 FVI light intensity sensor for ash dense measurement.展开更多
Objective In order to find early latent faults and prevent catastrophic failures, diagnosis of insulation condition by measuring technique of partial discharge(PD) in gas insulated switchgear (GIS) is applied in this ...Objective In order to find early latent faults and prevent catastrophic failures, diagnosis of insulation condition by measuring technique of partial discharge(PD) in gas insulated switchgear (GIS) is applied in this paper, which is one of the most basic ways for diagnosis of insulation condition. Methods Ultra high frequency(UHF) PD detection method by using internal sensors has been proved efficient, because it may avoid the disturbance of corona, but the sensor installation of this method will be limited by the structure and operation condition of GIS. There are some of electromagnetic (E-M) waves leak from the place of insulation spacer, therefore, the external sensors UHF measuring PD technique is applied, which isn't limited by the operation condition of GIS. Results This paper analyzes propagated electromagnetic (E-M) waves of partial discharge pulse excited by using the finite-difference time-domain (FDTD) method. The signal collected at the outer point is more complex than that of the inner point, and the signals' amplitude of outer is about half of the inner, because it propagates through spacer and insulation slot. Set up UHF PD measuring system. The typical PD in 252kV GIS bus bar was measured using PD detection UHF technique with external sensors. Finally, compare the results of UHF measuring technique using external sensors with the results of FDTD method simulation and the traditional IEC60270 method detection. Conclusion The results of experiment shows that the UHF technique can realize the diagnosis of insulation condition, the results of FDTD method simulation and the result UHF method detection can demonstrate each other, which gives references to further researches and application for UHF PD measuring technique.展开更多
In view of long-term transformer insulation resistance and dielectric loss measurement, measurement and according to the national standard formula conversion values are not completely consistent, in this paper, a vari...In view of long-term transformer insulation resistance and dielectric loss measurement, measurement and according to the national standard formula conversion values are not completely consistent, in this paper, a variety of transformers are studied, and the applicable scope of the conversion formula is discussed emphatically, combined with the test results are analyzed of transformer insulation resistance value to temperature and oiliness and dielectric loss tangent to temperature and oiliness, and puts forward suggestions on how to improve the insulation performance of transformer.展开更多
基金National High Technology Research and Development Program of China(2009AA04Z131)Natural Science Foundation of China (50877056)
文摘A novel thickness measurement method for surface insulation coating of silicon steel based on NIR spectrometry is explored.The NIR spectra of insulation coating of silicon steel were collected by acousto-optic tunable filter(AOTF) NIR spectrometer.To make full use of the effective information of NIR spectral data,discrete binary particle swarm optimization(DBPSO) algorithm was used to select the optimal wavelength variates.The new spectral data,composed of absorbance at selected wavelengths,were used to create the thickness quantitative analysis model by kernel partial least squares(KPLS) algorithm coupled with Boosting.The results of contrast experiments showed that the Boosting-KPLS model could efficiently improve the analysis accuracy and speed.It indicates that Boosting-KPLS is a more accurate and robust analysis method than KPLS for NIR spectral analysis.The maximal and minimal absolute error of 30 testing samples is respectively-0.02 μm and 0.19 μm,and the maximal relative error is 14.23%.These analysis results completely meet the practical measurement need.
文摘The in-situ measurement of sound reflection and airborne sound insulation characteristics of a noise barrier in Europe are currently performed following the CEN/TS 1793-5 European standard guidelines (last revision published in 2003 [1]). After some years a large number of barriers measured, the original method has been significantly enhanced and validated in the frame of the EU funded QUIESST project, WP3 [2]. The sound reflection measurement method has been improved using a square 9-microphone grid not rigidly connected to the loudspeaker, an optimized alignment algorithm of free-field and reflected impulse responses, including fractional step shifts and least squares estimation of the best relative position, and a correction for geometrical divergence and sound source directivity. Each single measurement is then validated by means of the Reduction Factor calculation. The airborne sound insulation measurement method has not been markedly changed since 2003, because the procedure is robust and easily applicable as it is, but some problems may still be encountered when measuring highly insulating noise barriers, due to a poor signal to noise ratio of the transmitted impulse response. In those cases it is difficult to realize just after the measurement whether the obtained data are valid or not. A method, applicable on site, to overcome this problem is described here. It is based on the Signal to Noise Ratio estimation of critical parts of the acquired impulse responses and gives a strong validation criterion.
文摘Ash dense(non-soluble sediment density,NSDD) is attached to the insulator surface material that can't dissolve in water,it is divided by the result of surface area and used for quantitative content of insulator surface non-soluble residues. Based on high voltage measurement,surface of outer insulation of ash can be used for the product line insulator pollution situation and determine whether it is able to withstand a variety of adverse factors. This paper proposes a method based on BH1750 FVI light intensity sensor for ash dense measurement.
文摘Objective In order to find early latent faults and prevent catastrophic failures, diagnosis of insulation condition by measuring technique of partial discharge(PD) in gas insulated switchgear (GIS) is applied in this paper, which is one of the most basic ways for diagnosis of insulation condition. Methods Ultra high frequency(UHF) PD detection method by using internal sensors has been proved efficient, because it may avoid the disturbance of corona, but the sensor installation of this method will be limited by the structure and operation condition of GIS. There are some of electromagnetic (E-M) waves leak from the place of insulation spacer, therefore, the external sensors UHF measuring PD technique is applied, which isn't limited by the operation condition of GIS. Results This paper analyzes propagated electromagnetic (E-M) waves of partial discharge pulse excited by using the finite-difference time-domain (FDTD) method. The signal collected at the outer point is more complex than that of the inner point, and the signals' amplitude of outer is about half of the inner, because it propagates through spacer and insulation slot. Set up UHF PD measuring system. The typical PD in 252kV GIS bus bar was measured using PD detection UHF technique with external sensors. Finally, compare the results of UHF measuring technique using external sensors with the results of FDTD method simulation and the traditional IEC60270 method detection. Conclusion The results of experiment shows that the UHF technique can realize the diagnosis of insulation condition, the results of FDTD method simulation and the result UHF method detection can demonstrate each other, which gives references to further researches and application for UHF PD measuring technique.
文摘In view of long-term transformer insulation resistance and dielectric loss measurement, measurement and according to the national standard formula conversion values are not completely consistent, in this paper, a variety of transformers are studied, and the applicable scope of the conversion formula is discussed emphatically, combined with the test results are analyzed of transformer insulation resistance value to temperature and oiliness and dielectric loss tangent to temperature and oiliness, and puts forward suggestions on how to improve the insulation performance of transformer.