The energy efficiency design of the exterior wall in the buildings of the hot summer and cold winter zone of China should consider the heat prevention in summer and the heat insulation in winter. The self-insulation o...The energy efficiency design of the exterior wall in the buildings of the hot summer and cold winter zone of China should consider the heat prevention in summer and the heat insulation in winter. The self-insulation of the exterior?wall is a more feasible design to satisfy the energy efficiency of buildings in the?zone. However, the systematic research is urgently needed for the self-insulation of the exterior wall in the hot summer and cold winter zone of China. The paper tested the thermal performance of the common non-clay materials such as shale sintered hollow brick, sand autoclaved aerated concrete block, etc. by means of indoor experiments. The energy efficiency effect of the common materials was verified using dynamic calculation soft PKPM and several constitutions of exterior wall with different main bricks and insulation materials on the heat bridge were simulated, too. Besides, the tests of the thermal performance of exterior wall in real constructions were carried out to testify the practical effect of the recommended constitutions of exterior wall with different main bricks and insulation materials on the heat bridge. The conclusions are: the physical and thermal properties of the six non-clay wall material are better than the clay porous brick;the thermal performance of the non-clay brick can be improved obviously through the rational arrangement of the holes;shale sintered hollow brick after increasing the holes and rationalizing the hole arrangement and sand autoclaved aerated concrete block are recommended for buildings in the hot summer and cold winter area of China. The dynamic calculation results show that the thermal performances?of the non-clay materials are all satisfied with the energy efficiency;The heat transfer coefficient of the exterior wall with composition?③,?in which?the main wall was sand autoclaved aerated concrete block and the material on the heat bridge was sand autoclaved aerated concrete plate, is the smallest among the three recommended compositions.展开更多
This paper mainly uses the method of numerical simulation, and study thermal insulation and energy saving characteristics on the exterior walls of the building and analyze the optimal layout scheme of building exterio...This paper mainly uses the method of numerical simulation, and study thermal insulation and energy saving characteristics on the exterior walls of the building and analyze the optimal layout scheme of building exterior wall and thermal insulation system. Finally, the paper study optimal thickness of insulation materials. The paper elaborate scheme of the existing building energy-saving for exterior wall and the scope of application, the system structure and the construction technology. The results showed that: extruded benzene board that can be used for exterior insulation, frame structure filled with wall preferred ceramsite hollow block. The paper can provides reference selection of insulation for building external wall energy-saving transformation scheme.展开更多
In order to solve the problem of poor thermal insulation in the current wood-plastic building,two kinds of structural wood wall integrated with wood plastic composite(WPC)are designed,and the thermal insulation perfor...In order to solve the problem of poor thermal insulation in the current wood-plastic building,two kinds of structural wood wall integrated with wood plastic composite(WPC)are designed,and the thermal insulation performances of the walls are studied.The results show that the WPC integrated wall with frame-shear structure has a good stability,and the excellent performance of the WPC can be fully realized.Wall studs and wall panels are important factors affecting the thermal performance of the walls.Wood plastic materials can meet the thermal performance requirements of the walls.The single-layer frame walls and double-layer frame walls integrated with the WPC both have a good thermal performance.According to‘Design Standard for Energy Efficiency of Public Buildings(GB 50189-2015)’,the heat transfer coefficient of the single-layer frame wall integrated with 20 mm thick WPC wall boards and WPC wall studs is 0.414 W/(m^(2)•K),which can meet the standard of wall thermal levelⅡt and is suitable for cold areas.The heat transfer coefficient of the double-layer frame wall integrated with 50 mm thick WPC wall panel and WPC wall studs is 0.207 W/(m^(2)•K),which can meet the standard of wall thermal levelⅠt and is suitable for severe cold areas.展开更多
The energy efficiency of a building depends on building envelope performance.The results presented in this paper are the first of a long-term building envelope research project at the Alternative Village at the Univer...The energy efficiency of a building depends on building envelope performance.The results presented in this paper are the first of a long-term building envelope research project at the Alternative Village at the University of Manitoba in Winnipeg,Manitoba,Canada.Five test buildings were constructed using the following systems:two wood frames with fiberglass batt insulation and dense pack cellulose,one polyurethane structural insulated panels(PUR SIP),and two with the Stay in place PVC concrete form building system using 102mm and 204mm of concrete externally insulated with 102mm of expanded polystyrene foam.All of the buildings had a common foundation and roof system with a footprint of 23.8 m2.Blower door tests were conducted to determine air tightness.Each structure was heated with an electrical resistance heater and maintained at a constant internal temperature.The thermal gradient through the wall and power consumption were monitored.The study period discussed in this report represents the main heating season from October 2011 to April 2012 consisting of 209 days.Based on the power consumption,the PUR SIP consumed the least at 2498 kWh,while the 204 mm Stay in place PVC concrete form building used the most at 2898 kWh for the same time period.The thermal gradient through the cross section of the wood frame structures was compared through the cavity insulation and at the stud.It was found that the cellulose building provided better thermal resistance along the stud when compared to the fiberglass batt insulation.展开更多
文摘The energy efficiency design of the exterior wall in the buildings of the hot summer and cold winter zone of China should consider the heat prevention in summer and the heat insulation in winter. The self-insulation of the exterior?wall is a more feasible design to satisfy the energy efficiency of buildings in the?zone. However, the systematic research is urgently needed for the self-insulation of the exterior wall in the hot summer and cold winter zone of China. The paper tested the thermal performance of the common non-clay materials such as shale sintered hollow brick, sand autoclaved aerated concrete block, etc. by means of indoor experiments. The energy efficiency effect of the common materials was verified using dynamic calculation soft PKPM and several constitutions of exterior wall with different main bricks and insulation materials on the heat bridge were simulated, too. Besides, the tests of the thermal performance of exterior wall in real constructions were carried out to testify the practical effect of the recommended constitutions of exterior wall with different main bricks and insulation materials on the heat bridge. The conclusions are: the physical and thermal properties of the six non-clay wall material are better than the clay porous brick;the thermal performance of the non-clay brick can be improved obviously through the rational arrangement of the holes;shale sintered hollow brick after increasing the holes and rationalizing the hole arrangement and sand autoclaved aerated concrete block are recommended for buildings in the hot summer and cold winter area of China. The dynamic calculation results show that the thermal performances?of the non-clay materials are all satisfied with the energy efficiency;The heat transfer coefficient of the exterior wall with composition?③,?in which?the main wall was sand autoclaved aerated concrete block and the material on the heat bridge was sand autoclaved aerated concrete plate, is the smallest among the three recommended compositions.
文摘This paper mainly uses the method of numerical simulation, and study thermal insulation and energy saving characteristics on the exterior walls of the building and analyze the optimal layout scheme of building exterior wall and thermal insulation system. Finally, the paper study optimal thickness of insulation materials. The paper elaborate scheme of the existing building energy-saving for exterior wall and the scope of application, the system structure and the construction technology. The results showed that: extruded benzene board that can be used for exterior insulation, frame structure filled with wall preferred ceramsite hollow block. The paper can provides reference selection of insulation for building external wall energy-saving transformation scheme.
文摘In order to solve the problem of poor thermal insulation in the current wood-plastic building,two kinds of structural wood wall integrated with wood plastic composite(WPC)are designed,and the thermal insulation performances of the walls are studied.The results show that the WPC integrated wall with frame-shear structure has a good stability,and the excellent performance of the WPC can be fully realized.Wall studs and wall panels are important factors affecting the thermal performance of the walls.Wood plastic materials can meet the thermal performance requirements of the walls.The single-layer frame walls and double-layer frame walls integrated with the WPC both have a good thermal performance.According to‘Design Standard for Energy Efficiency of Public Buildings(GB 50189-2015)’,the heat transfer coefficient of the single-layer frame wall integrated with 20 mm thick WPC wall boards and WPC wall studs is 0.414 W/(m^(2)•K),which can meet the standard of wall thermal levelⅡt and is suitable for cold areas.The heat transfer coefficient of the double-layer frame wall integrated with 50 mm thick WPC wall panel and WPC wall studs is 0.207 W/(m^(2)•K),which can meet the standard of wall thermal levelⅠt and is suitable for severe cold areas.
文摘The energy efficiency of a building depends on building envelope performance.The results presented in this paper are the first of a long-term building envelope research project at the Alternative Village at the University of Manitoba in Winnipeg,Manitoba,Canada.Five test buildings were constructed using the following systems:two wood frames with fiberglass batt insulation and dense pack cellulose,one polyurethane structural insulated panels(PUR SIP),and two with the Stay in place PVC concrete form building system using 102mm and 204mm of concrete externally insulated with 102mm of expanded polystyrene foam.All of the buildings had a common foundation and roof system with a footprint of 23.8 m2.Blower door tests were conducted to determine air tightness.Each structure was heated with an electrical resistance heater and maintained at a constant internal temperature.The thermal gradient through the wall and power consumption were monitored.The study period discussed in this report represents the main heating season from October 2011 to April 2012 consisting of 209 days.Based on the power consumption,the PUR SIP consumed the least at 2498 kWh,while the 204 mm Stay in place PVC concrete form building used the most at 2898 kWh for the same time period.The thermal gradient through the cross section of the wood frame structures was compared through the cavity insulation and at the stud.It was found that the cellulose building provided better thermal resistance along the stud when compared to the fiberglass batt insulation.