期刊文献+
共找到45篇文章
< 1 2 3 >
每页显示 20 50 100
Integrated device for multiscale series vibration reduction and energy harvesting 被引量:1
1
作者 Jihou YANG Weixing ZHANG Xiaodong YANG 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI CSCD 2023年第12期2227-2242,共16页
A multi-degree-of-freedom device is proposed,which can achieve efficient vibration reduction as the main objective and energy harvesting as the secondary purpose.The device comprises a multiscale nonlinear vibration a... A multi-degree-of-freedom device is proposed,which can achieve efficient vibration reduction as the main objective and energy harvesting as the secondary purpose.The device comprises a multiscale nonlinear vibration absorber(NVA)and piezoelectric components.Energy conversion and energy measurement methods are used to evaluate the device performance from multiple perspectives.Research has shown that this device can efficiently transfer transient energy from the main structure and convert a portion of transient energy into electrical energy.Main resonance and higher-order resonance are the main reasons for efficient energy transfer.The device can maintain high vibration reduction performance even when the excitation amplitude changes over a large range.Compared with the single structures with and without precompression,the multiscale NVA-piezoelectric device offers significant vibration reduction advantages.In addition,there are significant differences in the parameter settings of the two substructures for vibration reduction and energy harvesting. 展开更多
关键词 integrated device nonlinear vibration reduction energy harvesting transient vibration energy principle
下载PDF
Enhancement of electroluminescent properties of organic optoelectronic integrated device by doping phosphorescent dye 被引量:1
2
作者 雷疏影 钟建 +2 位作者 周殿力 朱方云 邓朝旭 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第11期434-440,共7页
Organic optoelectronic integrated devices(OIDs) with ultraviolet(UV) photodetectivity and different color emitting were constructed by using a thermally activated delayed fluorescence(TADF) material 4, 5-bis(ca... Organic optoelectronic integrated devices(OIDs) with ultraviolet(UV) photodetectivity and different color emitting were constructed by using a thermally activated delayed fluorescence(TADF) material 4, 5-bis(carbazol-9-yl)-1, 2-dicyanobenzene(2 CzPN) as host. The OIDs doping with typical red phosphorescent dye [tris(1-phenylisoquinoline)iridium(Ⅲ), Ir(piq)3], orange phosphorescent dye {bis[2-(4-tertbutylphenyl)benzothiazolato-N,C-(2')]iridium(acetylacetonate),(tbt)2 Ir(acac)}, and blue phosphorescent dye [bis(2, 4-di-fluorophenylpyridinato)-tetrakis(1-pyrazolyl)borate iridium(Ⅲ), FIr6] were investigated and compared. The(tbt)2 Ir(acac)-doped orange device showed better performance than those of red and blue devices, which was ascribed to more effective energy transfer. Meanwhile, at a low dopant concentration of 3 wt.%, the(tbt)2 Ir(acac)-doped OIDs showed the maximum luminance, current efficiency, power efficiency of 70786 cd/m^2, 39.55 cd/A, and 23.92 lm/W, respectively, and a decent detectivity of 1.07 × 10^11 Jones at a bias of -2 V under the UV-350 nm illumination. This work may arouse widespread interest in constructing high efficiency and luminance OIDs based on doping phosphorescent dye. 展开更多
关键词 organic optoelectronic integrated device thermally activated delayed fluorescence host phosphorescent dye high luminance
下载PDF
Development of an Integrated Disposable Device for SARSCoV-2 Nucleic Acid Extraction and Detection
3
作者 Jing Ma Yanzhe Hao +11 位作者 Meiling Hou Xiaoshan Zhang Jingduan Liu Haodi Meng Jiangbo Chang Xuejun Ma Jihua Liu Qingjie Ying Xianhua Wang Hongxia Li Yuxi Cao Xiaoguang Zhang 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2024年第6期639-646,共8页
Objective To develop a highly sensitive and rapid nucleic acid detection method for the severe acute respiratory syndrome coronavirus 2(SARS-CoV-2).Methods We designed,developed,and manufactured an integrated disposab... Objective To develop a highly sensitive and rapid nucleic acid detection method for the severe acute respiratory syndrome coronavirus 2(SARS-CoV-2).Methods We designed,developed,and manufactured an integrated disposable device for SARS-CoV-2 nucleic acid extraction and detection.The precision of the liquid transfer and temperature control was tested.A comparison between our device and a commercial kit for SARS-Cov-2 nucleic acid extraction was performed using real-time fluorescence reverse transcription polymerase chain reaction(RT-PCR).The entire process,from SARS-CoV-2 nucleic acid extraction to amplification,was evaluated.Results The precision of the syringe transfer volume was 19.2±1.9μL(set value was 20),32.2±1.6(set value was 30),and 57.2±3.5(set value was 60).Temperature control in the amplification tube was measured at 60.0±0.0℃(set value was 60)and 95.1±0.2℃(set value was 95)respectively.SARS-Cov-2 nucleic acid extraction yield through the device was 7.10×10^(6) copies/mL,while a commercial kit yielded 2.98×10^(6) copies/mL.The mean time to complete the entire assay,from SARS-CoV-2 nucleic acid extraction to amplification detection,was 36 min and 45 s.The detection limit for SARS-CoV-2 nucleic acid was 250 copies/mL.Conclusion The integrated disposable devices may be used for SARS-CoV-2 Point-of-Care test(POCT). 展开更多
关键词 An integrated disposable device SARS-Cov-2 Nucleic acid detection
下载PDF
High-sensitivity integrated devices based on surface plasmon resonance for sensing applications 被引量:3
4
作者 MAHMOUD H.ELSHORBAGY ALEXER CUADRADO JAVIER ALDA 《Photonics Research》 SCIE EI 2017年第6期173-180,共8页
A metallic nanostructured array that scatters radiation toward a thin metallic layer generates surface plasmon resonances for normally incident light. The location of the minimum of the spectral reflectivity serves to... A metallic nanostructured array that scatters radiation toward a thin metallic layer generates surface plasmon resonances for normally incident light. The location of the minimum of the spectral reflectivity serves to detect changes in the index of refraction of the medium under analysis. The normal incidence operation eases its integration with optical fibers. The geometry of the arrangement and the material selection are changed to optimize some performance parameters as sensitivity, figure of merit, field enhancement, and spectral width. This optimization takes into account the feasibility of the fabrication. The evaluated results of sensitivity(1020 nm/RIU)and figure of merit(614 RIU^(-1)) are competitive with those previously reported. 展开更多
关键词 High-sensitivity integrated devices based on surface plasmon resonance for sensing applications
原文传递
Creating Distinctive Connections between Multifunctional Microwave Circuits and Mobile-Terminal Radio-Frequency Integrated Chips Using Integrated Passive Device Technology
5
作者 Yongle Wu Mengdan Kong +1 位作者 Zheng Zhuang Weimin Wang 《China Communications》 SCIE CSCD 2021年第8期121-132,共12页
In this review,the advanced microwave devices based on the integrated passive device(IPD)technology are expounded and discussed in detail,involving the performance breakthroughs and circuit innovations.Then,the develo... In this review,the advanced microwave devices based on the integrated passive device(IPD)technology are expounded and discussed in detail,involving the performance breakthroughs and circuit innovations.Then,the development trend of IPD-based multifunctional microwave circuits is predicted further by analyzing the current research hot spots.This paper discusses a distinctive research area for microwave circuits and mobile-terminal radio-frequency integrated chips. 展开更多
关键词 CHIPS integrated passive device(IPD) MULTIFUNCTIONAL microwave circuit
下载PDF
Reliability analysis for vertical integration of protection,measurement,merge unit,and intelligent terminal device 被引量:1
6
作者 Ying Li Weiquan Wang +3 位作者 Liang Zhang Zhujian Liang Zhenli Xu Yuansheng Liang 《Global Energy Interconnection》 EI CSCD 2023年第6期772-784,共13页
The reliability analysis of vertically integrated protection devices is crucial for designing International Electrotechnical Commission(IEC)61850-based substations.This paper presents the hardware architecture of a fo... The reliability analysis of vertically integrated protection devices is crucial for designing International Electrotechnical Commission(IEC)61850-based substations.This paper presents the hardware architecture of a four-inone vertically integrated device and the information transmission path of each function based on the functional information transmission chain of protection devices,measurement and control devices,merging units,and intelligent terminals.Additionally,a reliability analysis model of the protection device and its protection system is constructed using the fault tree analysis method while considering the characteristics of each module of the vertically integrated device.The stability probability of the protection system in each state is analyzed by combining the state-transfer equations of line and busbar protection with a Markov chain.Finally,the failure rate and availability of the protection device and its protection system are calculated under different ambient temperatures using a 110 kV intelligent substation as an example.The sensitivity of each device module is analyzed. 展开更多
关键词 Vertical integration of secondary system device Reliability of secondary system IEC 61850-based substation Relay protection
下载PDF
Device Physics Research for Submicron and Deep Submicron Space Microelectronics Devices and Integrated Circuits
7
作者 Huang Chang, Yang Yinghua, Yu Shan, Zhang Xing, Xu Jun, Lu Quan, Chen Da 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 1992年第4期3-4,6-2,共4页
Device physics research for submicron and deep submicron space microelectronics devices and integrated circuits will be described in three topics.1.Thin film submicron and deep submicron SOS / CMOS devices and integra... Device physics research for submicron and deep submicron space microelectronics devices and integrated circuits will be described in three topics.1.Thin film submicron and deep submicron SOS / CMOS devices and integrated circuits.2.Deep submicron LDD CMOS devices and integrated circuits.3.C band and Ku band microwave GaAs MESFET and III-V compound hetrojunction HEM T and HBT devices and integrated circuits. 展开更多
关键词 GaAs MESFET CMOS device Physics Research for Submicron and Deep Submicron Space Microelectronics devices and integrated Circuits MOSFET length
下载PDF
Integrated separation-electrochemical detection device based on wood column for online identification of enantiomer
8
作者 Junli Guo Yuanfei Xue +4 位作者 Chenxi Zhao Junjian Zhao Zhida Gao Ye Mei Yan-Yan Song 《Nano Research》 SCIE EI CSCD 2024年第3期1893-1901,共9页
Chiral chemicals have attracted significant interest in the pharmaceutical industry,yet the separation methods to get pure enantiomers from racemic mixture are still challenging.To date,the separation of enantiomers s... Chiral chemicals have attracted significant interest in the pharmaceutical industry,yet the separation methods to get pure enantiomers from racemic mixture are still challenging.To date,the separation of enantiomers still mainly depends on chromatography using high-cost chiral stationary phases.Herein,wood channels were used as the handheld integrated device,and enantiomer separation was simultaneously detected using an electrochemical detector.In this method,a chiral UIO-66(L-UIO-66)modified enantiomer separation zone and carbonized wood based online detection zone are integrated along a single wood column.Based on the in situ separation results from the chronoamperometry data,the wood device shows excellent separation ability for a wide range of electrochemically active enantiomers,including 3,4-dihydroxyphenylalanine,amino acids,ascorbic acid,carnitine,and penicillamine with high chirality purity.The unbiased molecular dynamic simulations indicate that the excellent chiral recognition and separation are attributed to the different barriers from the bound states to the dissociated state of the enantiomers in the homochiral microenvironment of the framework.This integrated enantiomer separation-electrochemical detection device provides a novel,easy,and low-cost platform for the separation of pure enantiomer from racemic mixture. 展开更多
关键词 wood column integrated separation-detection device ENANTIOSELECTIVITY online sensing free energy barrier
原文传递
Robust optical mode converter based on topological waveguide arrays
9
作者 徐宇翔 唐文剑 +4 位作者 姜力炜 吴德兴 王恒 许冰聪 陈林 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第6期197-203,共7页
Optical mode converters are essential for enhancing the capacity of optical communication systems. However, fabrication errors restrict the further improvement of conventional mode converters. To address this challeng... Optical mode converters are essential for enhancing the capacity of optical communication systems. However, fabrication errors restrict the further improvement of conventional mode converters. To address this challenge, we have designed an on-chip TE0–TE1mode converter based on topologically protected waveguide arrays. The simulation results demonstrate that the converter exhibits a mode coupling efficiency of 93.5% near 1550 nm and can tolerate a relative fabrication error of 30%. Our design approach can be extended to enhance the robustness for other integrated photonic devices, beneficial for future development of optical network systems. 展开更多
关键词 on-chip integrated photonic devices topological photonics mode converter ROBUSTNESS
下载PDF
High-Performance Ionic Thermoelectric Supercapacitor for Integrated Energy Conversion-Storage
10
作者 Xinyu Yang Yuqing Tian +5 位作者 Bo Wu Wei Jia Chengyi Hou Qinghong Zhang Yaogang Li Hongzhi Wang 《Energy & Environmental Materials》 SCIE EI CAS CSCD 2022年第3期954-961,共8页
Converting low-grade waste heat into usable electricity and storing it simultaneously requires a new technology that realize the directional migration of electrons or ions under temperature difference and enrichment o... Converting low-grade waste heat into usable electricity and storing it simultaneously requires a new technology that realize the directional migration of electrons or ions under temperature difference and enrichment on the electrodes.Although the urgent demand of energy conversion-storage(ECS)has emerged in the field of wearable electronic,achieving the integrated bi-functional device remains challenge due to the different mechanisms of electrical transportation and storage.Here,we report an ionic thermoelectric supercapacitor that relies on the synergistic functions of thermoelectricity and supercapacitor in the thermoelectric ionogel electrolyte and high-performance hydrogel electrodes to enhance the ECS performance under a thermal gradient.The thermoelectric electrolyte is composed of polyacrylamide hydrogel and sodium carboxymethyl cellulose(PMSC),possessing cross-linked network with excellent cation selectivity,while the ionic thermoelectric properties are further improved in the presence of NaCl.The corresponding Seebeck coefficient and ionic conductivity of the NaCl–PMSC electrolyte reach 17.1 mV K^(-1)and 26.8 mS cm^(-1),respectively.Owing to good stretchability of both gel-based electrolyte and electrode,the fullstretchable integrated ECS device,termed ionic thermoelectric supercapacitor,presents promising thermal-charge storage capability(~1.3 mC,ΔT≈10 K),thus holds promise for wearable energy harvesting. 展开更多
关键词 integrated device ionic thermoelectric supercapacitor ionogel STRETCHABLE
下载PDF
Noise analysis and measurement of time delay and integration charge coupled device 被引量:4
11
作者 王德江 张涛 《Chinese Physics B》 SCIE EI CAS CSCD 2011年第8期348-353,共6页
Time delay and integration (TDI) charge coupled device (CCD) noise sets a fundamental limit on image sensor performance, especially under low illumination in remote sensing applications. After introducing the comp... Time delay and integration (TDI) charge coupled device (CCD) noise sets a fundamental limit on image sensor performance, especially under low illumination in remote sensing applications. After introducing the complete sources of CCD noise, we study the effects of TDI operation mode on noise, and the relationship between different types of noise and number of the TDI stage. Then we propose a new technique to identify and measure sources of TDI CCD noise employing mathematical statistics theory, where theoretical analysis shows that noise estimated formulation converges well. Finally, we establish a testing platform to carry out experiments, and a standard TDI CCD is calibrated by using the proposed method. The experimental results show that the noise analysis and measurement methods presented in this paper are useful for modeling TDI CCDs. 展开更多
关键词 time delay and integration charge coupled device noise measurement remote sensingapplication
下载PDF
Integrity Assessment of Medical Devices for Improving Hospital Services 被引量:3
12
作者 Fahad A.Alzahrani Masood Ahmad +2 位作者 Mohd Nadeem Rajeev Kumar Raees Ahmad Khan 《Computers, Materials & Continua》 SCIE EI 2021年第6期3619-3633,共15页
The present study examines the various techniques being used to maintain the integrity of the medical devices,and develops a quantitative framework to list these in the sequence of priority.To achieve the intended obj... The present study examines the various techniques being used to maintain the integrity of the medical devices,and develops a quantitative framework to list these in the sequence of priority.To achieve the intended objective,the study employs the combined procedure of Fuzzy Analytic Network Process(ANP)and Fuzzy Technical for Order Preference by Similarities to Ideal Solution(TOPSIS).We selected fuzzy based decision making techniques for assessing the integrity of medical devices.The suggested methodology was then used for classifying the suitable techniques used to evaluate the integrity of medical devices.Different techniques or the procedures of integrity assessment were ranked according to their satisfaction weights.The rating of the options determined the order of priority for the procedures.As per the findings of the study,among all the options,A1 was assessed to be the most likely option.This means that the integrity of medical devices of A2 is the highest amongst all the chosen alternatives.This analysis will be a corroborative guideline for manufacturers and developers to quantitatively test the integrity of medical devices in order to engineer efficacious devices.The evaluations undertaken with the assistance of the planned procedure are accurate and conclusive.Hence instead of conducting a manual valuation,this experimental study is a better and reliable option for assessing the integrity of the medical devices. 展开更多
关键词 Integrity of the medical devices fuzzy-ANP.TOPSIS security assessment
下载PDF
Compact TE-pass polarizer based on lithium-niobate-on-insulator assisted by indium tin oxide and silicon nitride
13
作者 刘家敏 张德龙 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第6期284-289,共6页
An indium tin oxide(ITO) and silicon nitride(Si_(3)N_(4)) assisted compact TE-pass waveguide polarizer based on lithiumniobate-on-insulator is proposed and numerically analyzed.By properly designing the ITO and Si_(3)... An indium tin oxide(ITO) and silicon nitride(Si_(3)N_(4)) assisted compact TE-pass waveguide polarizer based on lithiumniobate-on-insulator is proposed and numerically analyzed.By properly designing the ITO and Si_(3)N_(4) assisted structure and utilizing the epsilon-near-zero effect of ITO,the TM mode is strongly confined in the ITO layer with extremely high loss,while the TE mode is hardly affected and passes through the waveguide with low loss.The simulation results show that the polarizer has an extinction ratio of 22.5 dB and an insertion loss of 0.8 dB at the wavelength of 1.55 μm,and has an operating bandwidth of about 125 nm(from 1540 nm to 1665 nm) for an extinction ratio of>20 dB and an insertion loss of<0.95 dB.Moreover,the proposed device exhibits large fabrication tolerances.More notably,the device is compact,with a length of only 7.5 μm,and is appropriate for on-chip applications. 展开更多
关键词 POLARIZER lithium-niobate-on-insulator integrated optics devices optical waveguide
下载PDF
Photo-rechargeable batteries and supercapacitors:Critical roles of carbon-based functional materials 被引量:1
14
作者 Liqun Wang Lei Wen +5 位作者 Yueyu Tong Sihui Wang Xinggang Hou Xiaodong An Shi Xue Dou Ji Liang 《Carbon Energy》 CAS 2021年第2期225-252,共28页
As a clean and renewable energy source,solar energy is a competitive alternative to replace conventional fossil fuels.Nevertheless,its serious fluctuating nature usually leads to a poor alignment with the actual energ... As a clean and renewable energy source,solar energy is a competitive alternative to replace conventional fossil fuels.Nevertheless,its serious fluctuating nature usually leads to a poor alignment with the actual energy demand.To solve this problem,the direct solar-to-electrochemical energy conversion and storage have been regarded as a feasible strategy.In this context,the development of high-performance integrated devices based on solar energy conversion parts(i.e.,solar cells or photoelectrodes)and electrochemical energy storage units(i.e.,rechargeable batteries or supercapacitors[SCs])has become increasingly necessary and urgent,in which carbon and carbon-based functional materials play a fundamental role in determining their energy conversion/storage performances.Herein,we summarize the latest progress on these integrated devices for solar electricity energy conversion and storage,with special emphasis on the critical role of carbon-based functional materials.First,principles of integrated devices are introduced,especially roles of carbon-based materials in these hybrid energy devices.Then,two major types of important integrated devices,including photovoltaic and photoelectrochemicalrechargeable batteries or SCs,are discussed in detail.Finally,key challenges and opportunities in the future development are also discussed.By this review,we hope to pave an avenue toward the development of stable and efficient devices for solar energy conversion and storage. 展开更多
关键词 carbon-based materials electrochemical energy storage integrated devices photoelectric conversion solar energy
下载PDF
All‑Fiber Integrated Thermoelectrically Powered Physiological Monitoring Biosensor 被引量:3
15
作者 Xing Qing Huijun Chen +9 位作者 Fanjia Zeng Kangyu Jia Qing Shu Jianmei Wu Huimin Xu Weiwei Lei Dan Liu Xungai Wang Mufang Li Dong Wang 《Advanced Fiber Materials》 SCIE EI 2023年第3期1025-1036,共12页
Advanced fabric electronics for long-term personal physiological monitoring,with a self-sufficient energy source,high integrity,sensitivity,wearing comfort,and homogeneous components are urgently desired.Instead of as... Advanced fabric electronics for long-term personal physiological monitoring,with a self-sufficient energy source,high integrity,sensitivity,wearing comfort,and homogeneous components are urgently desired.Instead of assembling a self-powered biosensor,comprising a variety of materials with different levels of hardness,and supplementing with a booster or energy storage device,herein,an all-fiber integrated thermoelectrically powered physiological monitoring device(FPMD),is proposed and evaluated for production at an industrial scale.For the first time,an organic electrochemical transistor(OECT)biosensor is enabled by thermoelectric fabrics(TEFs)adaptively,sustainably and steadily without any additional accessories.Moreover,both the OECT and TEFs are constructed using a cotton/poly(3,4-ethylenedioxythiophene):poly(styrenesulfon ate)/dimethylsulfoxide/(3-glycidyloxypropyl)trimethoxysilane(PDG)yarn,which is lightweight,robust(90°bending for 1000 cycles)and sweat-resistant(ΔR/R0=1.9%).A small temperature gradient(ΔT=2.2 K)between the environment and the human body can drive the high-gain OECT(71.08 mS)with high fidelity,and a good signal to noise ratio.For practical applications,the on-body FPMD produced an enduring and steady output signal and demonstrated a linear monitoring region(sensitivity of 30.4 NCR(normalized current response)/dec,10 nM~50µM)for glucose in artificial sweat with reliable performance regarding anti-interference and reproducibility.This device can be expanded to the monitoring of various bio-markers and provides a new strategy for constructing wearable,comfortable,highly integrated and self-powered biosensors. 展开更多
关键词 Self-powered biosensor All-fiber integrated device Thermoelectric fabrics Fiber-assembled transistor Personal healthcare monitoring
原文传递
Simulated Method on the Release of Sediment Pollutants in the Temple Lake
16
作者 Sha Qian Wang Haitao Zhang Weihao 《Meteorological and Environmental Research》 CAS 2014年第1期51-54,共4页
[ Objective] The research aimed to study simulated method on the release of sediment pollutants in the Temple Lake. [ Method] For existing pollution status of the Temple Lake, sediments and overlying water were sample... [ Objective] The research aimed to study simulated method on the release of sediment pollutants in the Temple Lake. [ Method] For existing pollution status of the Temple Lake, sediments and overlying water were sampled by the integrated device. Based on the technical route, through the orthogonal test, release processes of nitrogen and phosphorus from sediment were simulated, and their release speeds were estimated under different temperatures, pH and DO in the laboratory. Relationship between environmental factor and pollutant release was explored. [ Result] The integrated device of sediment sampling and test had simple structure, cheap cost and easy operation, and sediment pollution test could be conducted without disturbing sediment after collecting sediment. Among the studied three impact factors, temperature had the maximum influence on contaminant release process, which should be considered as the important factor of future research. [ Conclusion] Compared with routine research method of sediment contaminant release from other lakes, simulated method of contaminant release from sediment in the Temple Lake had many advantaqes, which was favorable for scientific research in latter period and actual lake control. 展开更多
关键词 SEDIMENT Contaminant release integrated device Simulated method China
下载PDF
Full-scale application and performance of a new multi-self-reflow decentralized Wastewater treatment device: Impact of hydraulic and pollutant loads
17
作者 Xiang Li Yong Huang +2 位作者 Yi Guo Wei Li Yuqing Li 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2023年第9期37-47,共11页
Decentralized treatment of wastewater in rural areas usually has several challenges,which include large fluctuations in pollutant concentration and water quantity,complicated operation and maintenance of conventional ... Decentralized treatment of wastewater in rural areas usually has several challenges,which include large fluctuations in pollutant concentration and water quantity,complicated operation and maintenance of conventional biochemical treatment equipment,resulting in poor stability and a low compliance rate of the wastewater treatment process.In order to solve the above problems,a new integration reactor is designed,which uses gravity and aeration tail gas self-reflux technology to realize the reflux of sludge and the nitrification liquid,respectively.The feasibility and operation characteristics of its application for decentralized wastewater treatment in rural areas are explored.The results demonstrated that,under constant influent,the device showed strong tolerance to the shock of pollutant load.The chemical oxygen demand,NH_(4)^(+)-N,total nitrogen and total phosphorus fluctuated in the ranges of 95–715 mg/L,7.6–38.5 mg/L,9.32–40.3 mg/L and 0.84–4.9 mg/L,respectively.The corresponding effluent compliance rates were 82.1%,92.8%,96.4%and 96.3%,respectively.When the wastewater discharge was non-constant and the maximum single-day Qmax/Qmin reached 5,all indicators of the effluent met the relevant discharge standard.The integrated device also demonstrated high phosphorus enrichment levels in its anaerobic zone;the concentration of phosphorus reached a maximum of 26.9 mg/L,which created a good environment for phosphorus removal.The microbial community analysis showed that sludge digestion,denitrification,and phosphorus-accumulating bacteria all played an important role in pollutant treatment. 展开更多
关键词 Decentralized wastewater treatment integrated device Self-reflux technology Load shock Operational characteristics
原文传递
All polymer asymmetric Mach-Zehnder interferometer waveguide sensor by imprinting bonding and laser polishing 被引量:2
18
作者 刘豫 孙月 +5 位作者 衣云骥 田亮 曹悦 陈长鸣 孙小强 张大明 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第12期332-338,共7页
We present an all polymer asymmetric Mach-Zehnder interferometer (AMZI) waveguide sensor based on imprinting bonding and laser polishing method. The fabrication methods are compatible with high accuracy waveguide se... We present an all polymer asymmetric Mach-Zehnder interferometer (AMZI) waveguide sensor based on imprinting bonding and laser polishing method. The fabrication methods are compatible with high accuracy waveguide sensing structure. The rectangle waveguide structure of this sensor has three sensing surfaces contacting the test media, and its sensing accuracy can be increased 5 times compared with that of one surface sensing structure. An AMZI device structure is designed. The single mode condition, the length of the sensing arm, and the length deviation between the sensing arm and the reference arm are optimized. The length deviation is optimized to be 19.8 μm in a refractive index range between 1.470 and 1.545. We fabricate the AMZI waveguide by lithography and wet etching method. The imprinting bonding and laser polishing method is proposed and investigated. The insertion loss is between-80.36 dB and-10.63 dB. The average and linear sensitivity are 768.1 dB/RIU and 548.95 dB/RIU, respectively. And the average and linear detection resolution of the sensor are 1.3010-6 RIU (RIU:refractive index unit) and 1.8210-5 RIU, respectively. This sensor has a fast and cost-effective fabrication process which can be used in the cases of requiring portability and disposability. 展开更多
关键词 integrated optics devices polymer waveguides SENSORS microstructure fabrication
下载PDF
Subwavelength grating waveguide devices in siliconon-insulators for integrated microwave photonics 被引量:1
19
作者 Lawrence R.Chen 《Chinese Optics Letters》 SCIE EI CAS CSCD 2017年第1期13-17,共5页
We provide an overview of our recent work on developing subwavelength grating (SWG) waveguide devices as an enabling technology for integrated microwave photonics. First, we describe wavelength-selective SWG wavegui... We provide an overview of our recent work on developing subwavelength grating (SWG) waveguide devices as an enabling technology for integrated microwave photonics. First, we describe wavelength-selective SWG waveguide filters, including ring resonators, Bragg gratings, and contradirectional couplers. Second, we discuss the development of an index variable optical true time delay line that exploits spatial diversity in an equal-length waveguide array. These SWG waveguide components are fundamental building blocks for realizing more complex structures for advanced microwave photonic signal processing. 展开更多
关键词 GRATINGS Radio frequency photonics Wavelength filtering devices integrated optics devices
原文传递
Tunable optical filter using second-order micro-ring resonator 被引量:1
20
作者 邓林 李德钊 +3 位作者 刘子龙 孟英昊 郭小男 田永辉 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第2期250-253,共4页
In this paper, we design and fabricate a silicon integrated optical filter consisting of two cascaded micro-ring resonators and two straight waveguides. Two micro-heaters are fabricated on the top of two micro-rings r... In this paper, we design and fabricate a silicon integrated optical filter consisting of two cascaded micro-ring resonators and two straight waveguides. Two micro-heaters are fabricated on the top of two micro-rings respectively, which are employed to modulate the micro-rings to perform the function of a tunable optical filter by the thermo–optic effect. The static response test indicates that the extinction ratio and 3-d B bandwidth are 29.01 d B and 0.21 nm respectively, the dynamic response test indicates that the 10%–90% rise and 90%–10% fall time of the filter are 16 μs and 12 μs, respectively,which can meet the requirements of optical communication and information processing. Finally, the power consumption of the device is also characterized, and the total power consumption is about 9.43 m W/nm, which has been improved efficiently. 展开更多
关键词 integrated optics wavelength filtering devices resonators photonic integrated circuits
下载PDF
上一页 1 2 3 下一页 到第
使用帮助 返回顶部