The rail weighbridge system of a railway freight station is introduced firstly, and then the earthing method for protection of the rail weighbridge system against lightning based on YLG-60 equipotential bonding surge ...The rail weighbridge system of a railway freight station is introduced firstly, and then the earthing method for protection of the rail weighbridge system against lightning based on YLG-60 equipotential bonding surge protection device is shown.展开更多
Via database technology, a perfect lightning protection integrated service work platform is established, thereby realizing paperless data management of routine business.
An accurate determination of lightning protection zone is an important issue in the analysis and design of an appropri-ate lightning protection system. This paper presents a fast and accurate protection zone determina...An accurate determination of lightning protection zone is an important issue in the analysis and design of an appropri-ate lightning protection system. This paper presents a fast and accurate protection zone determination methodology for metallic lightning rod. The methodology is based on Quasi Monte Carlo Integration technique applied to Method of Moments (MoM) solution of Integral Equations. As an example, solution of the integral equation for unknown charge distribution on lightning rod is obtained. The electric field in the region surrounding the rod is then computed and the protection zone plotted accordingly. The effect of the thickness of the rod on the protection zone is also studied.展开更多
This paper is devoted to the study of the most suitable protocols needed to verify the lightning protection and ground resistance quality in a large-scale scientific facility located on a site with high risk of lightn...This paper is devoted to the study of the most suitable protocols needed to verify the lightning protection and ground resistance quality in a large-scale scientific facility located on a site with high risk of lightning strikes. We illustrate this work by reviewing a case study: the largest telescopes of the Northern Hemisphere Cherenkov Telescope Array, CTA-N. This array hosts sensitive and high-speed optoelectronics instrumentation and sits on a clear, free from obstacle terrain at around 2400 m above sea level. The site offers a top-quality sky but also features challenging conditions for a lightning protection system: the terrain is volcanic and has electrical resistivities well above 1 kOhm·m. In addition, the environment often exhibits humidities well below 5%, and strong winds pose challenging conditions. On the other hand, the </span><span style="font-family:Verdana;">high complexity of a Cherenkov telescope structure does not allow a straightforward</span><span style="font-family:Verdana;"> application of lightning protection standards. We describe here how the risk assessment of direct strike impacts was made and how contact voltages and ground system were both tested. Finite Element Simulation (COMSOL Multiphysics) has been used to estimate the current flowing through the parts of the earthing system designed for the telescopes in the case of a direct strike impact. This work is intended to provide assistance to scientists and managers involved in the construction of scientific installations, particularly those in charge of defining verifiable reliability and safety requirements for lightning protection.展开更多
文摘The rail weighbridge system of a railway freight station is introduced firstly, and then the earthing method for protection of the rail weighbridge system against lightning based on YLG-60 equipotential bonding surge protection device is shown.
文摘Via database technology, a perfect lightning protection integrated service work platform is established, thereby realizing paperless data management of routine business.
文摘An accurate determination of lightning protection zone is an important issue in the analysis and design of an appropri-ate lightning protection system. This paper presents a fast and accurate protection zone determination methodology for metallic lightning rod. The methodology is based on Quasi Monte Carlo Integration technique applied to Method of Moments (MoM) solution of Integral Equations. As an example, solution of the integral equation for unknown charge distribution on lightning rod is obtained. The electric field in the region surrounding the rod is then computed and the protection zone plotted accordingly. The effect of the thickness of the rod on the protection zone is also studied.
文摘This paper is devoted to the study of the most suitable protocols needed to verify the lightning protection and ground resistance quality in a large-scale scientific facility located on a site with high risk of lightning strikes. We illustrate this work by reviewing a case study: the largest telescopes of the Northern Hemisphere Cherenkov Telescope Array, CTA-N. This array hosts sensitive and high-speed optoelectronics instrumentation and sits on a clear, free from obstacle terrain at around 2400 m above sea level. The site offers a top-quality sky but also features challenging conditions for a lightning protection system: the terrain is volcanic and has electrical resistivities well above 1 kOhm·m. In addition, the environment often exhibits humidities well below 5%, and strong winds pose challenging conditions. On the other hand, the </span><span style="font-family:Verdana;">high complexity of a Cherenkov telescope structure does not allow a straightforward</span><span style="font-family:Verdana;"> application of lightning protection standards. We describe here how the risk assessment of direct strike impacts was made and how contact voltages and ground system were both tested. Finite Element Simulation (COMSOL Multiphysics) has been used to estimate the current flowing through the parts of the earthing system designed for the telescopes in the case of a direct strike impact. This work is intended to provide assistance to scientists and managers involved in the construction of scientific installations, particularly those in charge of defining verifiable reliability and safety requirements for lightning protection.