In order to solve the problem of poor thermal insulation in the current wood-plastic building,two kinds of structural wood wall integrated with wood plastic composite(WPC)are designed,and the thermal insulation perfor...In order to solve the problem of poor thermal insulation in the current wood-plastic building,two kinds of structural wood wall integrated with wood plastic composite(WPC)are designed,and the thermal insulation performances of the walls are studied.The results show that the WPC integrated wall with frame-shear structure has a good stability,and the excellent performance of the WPC can be fully realized.Wall studs and wall panels are important factors affecting the thermal performance of the walls.Wood plastic materials can meet the thermal performance requirements of the walls.The single-layer frame walls and double-layer frame walls integrated with the WPC both have a good thermal performance.According to‘Design Standard for Energy Efficiency of Public Buildings(GB 50189-2015)’,the heat transfer coefficient of the single-layer frame wall integrated with 20 mm thick WPC wall boards and WPC wall studs is 0.414 W/(m^(2)•K),which can meet the standard of wall thermal levelⅡt and is suitable for cold areas.The heat transfer coefficient of the double-layer frame wall integrated with 50 mm thick WPC wall panel and WPC wall studs is 0.207 W/(m^(2)•K),which can meet the standard of wall thermal levelⅠt and is suitable for severe cold areas.展开更多
When a historic façade needs to be preserved or when the seismic considerations favor use of a concrete wall system and fire considerations limit exterior thermal insulation,one needs to use interior thermal insu...When a historic façade needs to be preserved or when the seismic considerations favor use of a concrete wall system and fire considerations limit exterior thermal insulation,one needs to use interior thermal insulation systems.Interior thermal insulation systems are less effective than the exterior systems and will not reduce the effect of thermal bridges.Yet they may be successfully used and,in many instances,are recommended as a complement to the exterior insulation.This paper presents one of these cases.It is focused on the most successful applications of capillary active,dynamic interior thermal insulation.This happens when such insulation is integrated with heating,cooling and ventilation,air conditioning(HVAC)system.Starting with a pioneering work of the Technical University in Dresden in development of capillary active interior insulations,we propose a next generation,namely,a bio-fiber thermal insulation.When completing the review,this paper proposes a concept of a joint research project to be undertaken by partners from the US(where improvement of indoor climate in exposed coastal areas is needed),China(indoor climate in non-air conditioned concrete buildings is an issue),and Germany(where the bio-fiber technology has been developed).展开更多
文摘In order to solve the problem of poor thermal insulation in the current wood-plastic building,two kinds of structural wood wall integrated with wood plastic composite(WPC)are designed,and the thermal insulation performances of the walls are studied.The results show that the WPC integrated wall with frame-shear structure has a good stability,and the excellent performance of the WPC can be fully realized.Wall studs and wall panels are important factors affecting the thermal performance of the walls.Wood plastic materials can meet the thermal performance requirements of the walls.The single-layer frame walls and double-layer frame walls integrated with the WPC both have a good thermal performance.According to‘Design Standard for Energy Efficiency of Public Buildings(GB 50189-2015)’,the heat transfer coefficient of the single-layer frame wall integrated with 20 mm thick WPC wall boards and WPC wall studs is 0.414 W/(m^(2)•K),which can meet the standard of wall thermal levelⅡt and is suitable for cold areas.The heat transfer coefficient of the double-layer frame wall integrated with 50 mm thick WPC wall panel and WPC wall studs is 0.207 W/(m^(2)•K),which can meet the standard of wall thermal levelⅠt and is suitable for severe cold areas.
文摘When a historic façade needs to be preserved or when the seismic considerations favor use of a concrete wall system and fire considerations limit exterior thermal insulation,one needs to use interior thermal insulation systems.Interior thermal insulation systems are less effective than the exterior systems and will not reduce the effect of thermal bridges.Yet they may be successfully used and,in many instances,are recommended as a complement to the exterior insulation.This paper presents one of these cases.It is focused on the most successful applications of capillary active,dynamic interior thermal insulation.This happens when such insulation is integrated with heating,cooling and ventilation,air conditioning(HVAC)system.Starting with a pioneering work of the Technical University in Dresden in development of capillary active interior insulations,we propose a next generation,namely,a bio-fiber thermal insulation.When completing the review,this paper proposes a concept of a joint research project to be undertaken by partners from the US(where improvement of indoor climate in exposed coastal areas is needed),China(indoor climate in non-air conditioned concrete buildings is an issue),and Germany(where the bio-fiber technology has been developed).