期刊文献+
共找到1,568篇文章
< 1 2 79 >
每页显示 20 50 100
Impact of interconnections and renewable energy integration on the Philippine-Sabah Power Grid systems
1
作者 Tristan G.Magallones,Jr. Jai Govind Singh 《Global Energy Interconnection》 EI CSCD 2023年第3期253-272,共20页
This study presents a comprehensive impact analysis of the rotor angle stability of a proposed international connection between the Philippines and Sabah,Malaysia,as part of the Association of Southeast Asian Nations(... This study presents a comprehensive impact analysis of the rotor angle stability of a proposed international connection between the Philippines and Sabah,Malaysia,as part of the Association of Southeast Asian Nations(ASEAN)Power Grid.This study focuses on modeling and evaluating the dynamic performance of the interconnected system,considering the high penetration of renewable sources.Power flow,small signal stability,and transient stability analyses were conducted to assess the ability of the proposed linked power system models to withstand small and large disturbances,utilizing the Power Systems Analysis Toolbox(PSAT)software in MATLAB.All components used in the model are documented in the PSAT library.Currently,there is a lack of publicly available studies regarding the implementation of this specific system.Additionally,the study investigates the behavior of a system with a high penetration of renewable energy sources.Based on the findings,this study concludes that a system is generally stable when interconnection is realized,given its appropriate location and dynamic component parameters.Furthermore,the critical eigenvalues of the system also exhibited improvement as the renewable energy sources were augmented. 展开更多
关键词 Modeling of ASEAN power grid Rotor angle stability of asynchronous Philippine-Sabah interconnection in ASEAN power grid The impact of renewable energy integration on Philippine-Sabah interconnection in ASEAN power grid
下载PDF
Implementation of Dynamic Line Rating in a Sub-Transmission System for Wind Power Integration
2
作者 Saifal Talpur Carl Johan Wallnerstrom +1 位作者 Patrik Hilber Christer Flood 《Smart Grid and Renewable Energy》 2015年第8期233-249,共17页
Based on conventional static line rating method, the actual current carrying capability of overhead conductors cannot be judged. Due to continuous increment in electricity demand and the difficulties associated with n... Based on conventional static line rating method, the actual current carrying capability of overhead conductors cannot be judged. Due to continuous increment in electricity demand and the difficulties associated with new line constructions, the overhead lines are therefore required to be rated based on a method that should establish their real-time capability in terms of electricity transmission. The method used to determine the real-time ampacity of overhead conductors not only can enhance their transmission capacity but can also help in allowing excessive renewable generation in the electricity network. In this research work, the issues related to analyzing an impact of wind power on periodical loading of overhead line as well as finding its static and dynamic ampacities with line current are investigated in detail. Moreover, the investigation related to finding a suitable location for the construction of a 60 MW wind farm is taken on board. Thereafter, the wind park is integrated with a regional grid, owned by Fortum Distribution AB. In addition to that, the electricity generated from the wind park is also calculated in this project. Later on, the work is devoted to finding the static and dynamic line ratings for “VL3” overhead conductor by using IEEE-738-2006 standard. Furthermore, the project also deals with finding the line current and making its comparison with maximum capacity of overhead conductor (VL3) for loading it in such a way that no any violation of safe ground clearance requirements is observed at all. Besides, the line current, knowing the conductor temperature when it transmits the required electricity in the presence of wind power generation is also an important factor to be taken into consideration. Therefore, based on real-time ambient conditions with actual line loading and with the help of IEEE-738-2006 standard, the conductor temperature is also calculated in this project. At the end, an economic analysis is performed to evaluate the financial advantages related to applying the dynamic line ratings approach in place of traditional static line ratings technique across an overhead conductor (VL3) and to know how much beneficial it is to temporarily postpone the rebuilding and/or construction of a new transmission line. Furthermore, an economic analysis related to wind power system is taken into consideration as well to get familiar with the costs related to building and connecting a 60 MW wind farm with the regional grid. 展开更多
关键词 Overhead Conductor STATIC and DYNAMIC Ampacities Real-Time Weather Conditions STATIC and DYNAMIC LINE RATING Techniques WIND power integration Regional grid LINE Current. Conductor Temperature WIND power ECONOMICS DYNAMIC LINE RATING ECONOMICS
下载PDF
Trans-regional transmission of large-scale hydropower: problems and solutions in receiving power grid 被引量:5
3
作者 Jianyu Lu Jianjian Shen +1 位作者 Chengguo Su Qianqian Shen 《Global Energy Interconnection》 2019年第4期342-350,共9页
Large-capacity hydropower transmission from southwestern China to load centers via ultra-high voltage direct current(UHVDC) or ultra-high voltage alternating current(UHVAC) transmission lines is an important measure o... Large-capacity hydropower transmission from southwestern China to load centers via ultra-high voltage direct current(UHVDC) or ultra-high voltage alternating current(UHVAC) transmission lines is an important measure of the accommodation of large-scale hydropower in China. The East China Grid(ECG) is the main hydropower receiver of the west–east power transmission channel in China. Moreover, it has been subject to a rapidly increasing rate of hydropower integration over the past decade. Currently, large-scale outer hydropower is one of the primary ECG power sources. However, the integration of rapidly increasing outer hydropower into the power grid is subject to a series of severe drawbacks. Therefore, this study considered the load demands and hydropower transmission characteristics for the analysis of several major problems and the determination of appropriate solutions. The power supply-demand balance problem, hydropower transmission schedule problem, and peakshaving problem were considered in this study. Correspondingly, three solutions are suggested in this paper, which include coordination between the outer hydropower and local power sources, an inter-provincial power complementary operation, and the introduction of a market mechanism. The findings of this study can serve as a basis to ensure that the ECG effectively receives an increased amount of outer hydropower in the future. 展开更多
关键词 HYDROpower integration multi-energy COORDINATION MULTI-power grid COORDINATION
下载PDF
Predictive direct power control of three-phase PWM rectifier based on TOGI grid voltage sensor free algorithm
4
作者 ZHAO Feng LI Shute +4 位作者 CHEN Xiaoqiang WANG Ying GAN Yanqi NIU Xinqiang ZHANG Fan 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2022年第4期451-459,共9页
In predictive direct power control(PDPC)system of three-phase pulse width modulation(PWM)rectifier,grid voltage sensor makes the whole system more complex and costly.Therefore,third-order generalized integrator(TOGI)i... In predictive direct power control(PDPC)system of three-phase pulse width modulation(PWM)rectifier,grid voltage sensor makes the whole system more complex and costly.Therefore,third-order generalized integrator(TOGI)is used to generate orthogonal signals with the same frequency to estimate the grid voltage.In addition,in view of the deviation between actual and reference power in the three-phase PWM rectifier traditional PDPC strategy,a power correction link is designed to correct the power reference value.The grid voltage sensor free algorithm based on TOGI and the corrected PDPC strategy are applied to three-phase PWM rectifier and simulated on the simulation platform.Simulation results show that the proposed method can effectively eliminate the power tracking deviation and the grid voltage.The effectiveness of the proposed method is verified by comparing the simulation results. 展开更多
关键词 three-phase PWM rectifier predictive direct power control grid voltage sensor free algorithm third-order generalized integrator power correction
下载PDF
Path to Coordinated Development of Wind Power and Power Grids in China
5
作者 Jiang Liping Wang Qiankun 《Electricity》 2012年第5期1-5,共5页
Based on an analysis of the misunderstandings and problems concerning wind power development, this paper summarizes the experiences of the coordinated development of wind power and power grids in foreign countries, an... Based on an analysis of the misunderstandings and problems concerning wind power development, this paper summarizes the experiences of the coordinated development of wind power and power grids in foreign countries, and proposes principles and strategies for the coordinated development of wind power and power grids, and related measures and suggestions for large scale development of wind power in China. 展开更多
关键词 power grid wind power grid integration FLEXIBILITY clean development
下载PDF
Investigation on Grid Connections of Wind Power and PV Power in China
6
作者 State Electricity Regulatory Commission Zhang sufang 《Electricity》 2011年第3期40-46,共7页
In order to fully comprehend the developing status of wind power and photovoltaic (PV) power generation, a special investigation on the integration of wind power and PV power was launched by the agencies of the State ... In order to fully comprehend the developing status of wind power and photovoltaic (PV) power generation, a special investigation on the integration of wind power and PV power was launched by the agencies of the State Electricity Regulatory Commission (SERC) throughout China during July-October 2010. This report is completed based on the investigation along with routine supervisory and management programs. There are totally 573 wind power projects and 94 PV power projects involved. Existing problems in these projects are pointed out and proposals for regulation are put forward. 展开更多
关键词 wind power PV solar power grid integration electricity tariff
下载PDF
Effects of Large-Scale Wind Energy Base on Power Grid Company
7
作者 Wang Ningbe 《Electricity》 2012年第1期40-44,共5页
The first stage project of Jiuquan wind energy base with 5.5-GW installed capacity is about to be completed. However, there exist several technical issues such as power transfer capability, electricity accommodation, ... The first stage project of Jiuquan wind energy base with 5.5-GW installed capacity is about to be completed. However, there exist several technical issues such as power transfer capability, electricity accommodation, frequency control and peak load regulation as well as system stability. In addition, the high capital cost and operation cost of the supporting transmission project invested and constructed by the Gansu Provincial Power Company will definitely have significant impacts on the management and economic profit of the Company. Through analysis of the construction and operation cost changes resulting from the wind power collection and delivery project, the author carried out research into the effects of developing large-scale wind power base on the management and economic benefits of power grid enterprises and proposed corresponding suggestions to make the related policies perfect. 展开更多
关键词 wind power grid integration economic benefit operation and management
下载PDF
Multi-agent and ant colony optimization for ship integrated power system network reconfiguration 被引量:3
8
作者 WANG Zheng HU Zhiyuan YANG Xuanfang 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2022年第2期489-496,共8页
Electric power is widely used as the main energy source of ship integrated power system(SIPS), which contains power network and electric power network. SIPS network reconfiguration is a non-linear large-scale problem.... Electric power is widely used as the main energy source of ship integrated power system(SIPS), which contains power network and electric power network. SIPS network reconfiguration is a non-linear large-scale problem. The reconfiguration solution influences the safety and stable operation of the power system. According to the operational characteristics of SIPS, a simplified model of power network and a mathematical model for network reconfiguration are established. Based on these models, a multi-agent and ant colony optimization(MAACO) is proposed to solve the problem of network reconfiguration. The simulations are carried out to demonstrate that the optimization method can reconstruct the integrated power system network accurately and efficiently. 展开更多
关键词 ship integrated power system(SIPS) multi-agent and ant colony optimization(MAACO) network reconfiguration ring grid fault recovery
下载PDF
Structured Microgrids (SμGs) and Flexible Electronic Large Power Transformers (FeLPTs) 被引量:4
9
作者 Don Tan 《CES Transactions on Electrical Machines and Systems》 CSCD 2020年第4期255-263,共9页
Structured microgrids(SμGs)and Flexible electronic large power transformers(FeLPTs)are emerging as two essential technologies for renewable energy integration,flexible power transmission,and active control.SμGs prov... Structured microgrids(SμGs)and Flexible electronic large power transformers(FeLPTs)are emerging as two essential technologies for renewable energy integration,flexible power transmission,and active control.SμGs provide the integration of renewable energy and storage to balance the energy demand and supply as needed for a given system design.FeLPT’s flexibility for processing,control,and re-configurability offers the capability for flexible transmission for effective flow control and enable SμGs connectivity while still keeping multiscale system level control.Early adaptors for combined heat and power have demonstrated significant economic benefits while reducing environmental foot prints.They bring tremendous benefits to utility companies also.With storage and active control capabilities,a 300-percent increase in bulk transmission and distribution lines are possible without having to increase capacity.SμGs and FeLPTs will also enable the utility industry to be better prepared for the emerging large increase in base load demand from electric transportation and data centers.This is a win-win-win situation for the consumer,the utilities(grid operators),and the environment.SμGs and FeLPTs provide value in power substation,energy surety,reliability,resiliency,and security.It is also shown that the initial cost associated with SμG and FeLPTs deployment can be easily offset with reduced operating cost,which in turn reduces the total life-cycle cost by 33%to 67%. 展开更多
关键词 Terms-Structured microgrids flexible electronic large power transformers energy systems renewable integration grid modernization active control life-cycle cost
下载PDF
Special report on relationship between wind farms and power grids 被引量:1
10
作者 Dai Huizhu Wang Weisheng Li Hanxiang 《Engineering Sciences》 EI 2009年第2期13-17,共5页
The installed capacity of a large scale wind power plant will be up to a number of hundreds MW, and the wind power is transmitted to load centers through long distance transmission lines with 220 kV, 500 kV, or 750 kV... The installed capacity of a large scale wind power plant will be up to a number of hundreds MW, and the wind power is transmitted to load centers through long distance transmission lines with 220 kV, 500 kV, or 750 kV. Therefore, it is necessary not only considering the power transmission line between a wind power plant and the first connection node of the power network, but also the power network among the group of those wind power plants in a wind power base, the integration network from the base to the existed grids, as well as the distribution and consumption of the wind power generation by loads. Meanwhile, the impact of wind power stochastic fluctuation on power systems must be studied. In recent years, wind power prediction technology has been studied by the utilities and wind power plants. As a matter of fact, some European countries have used this prediction technology as a tool in national power dispatch centers and wind power companies. 展开更多
关键词 wind farms (wind power plants) power grids wind power integration wind power prediction
下载PDF
Development of electric power cooperation in Northeast Asia 被引量:4
11
作者 Nikolai Voropai Sergei Podkovalnikov +1 位作者 Lyudmila Chudinova Ksenia Letova (Kushkina) 《Global Energy Interconnection》 2019年第1期1-6,共6页
The development of interstate electric ties ISETs and grids(ISGs) is a global process; recently, countries of Northeast Asia(NEA) that were previously very poorly connected have started to study the possibility of con... The development of interstate electric ties ISETs and grids(ISGs) is a global process; recently, countries of Northeast Asia(NEA) that were previously very poorly connected have started to study the possibility of constructing ISETs and ISGs. This paper describes the current state of the interstate transmissions in the NEA region, considering the prospective projects of ISETs in NEA. The results of the system optimization study on prospective NEA ISGs are provided. The proposals on the development of electric power cooperation in NEA are formulated. 展开更多
关键词 In teg RATI on ELECTRIC power industry Interstate ELECTRIC TIES power grids NORTHEAST ASIA Economic effectiveness
下载PDF
Feasibility Study of Smart Grid in Bangladesh
12
作者 Faysal Nayan Md. Aminul Islam Shifat Mahmud 《Energy and Power Engineering》 2013年第4期1531-1535,共5页
The agenda of this paper is to discuss about the significance and a detailed feasibility study of practical implementation of Smart Grid in Bangladesh. Smart grid refers to an electric power system that enhances grid ... The agenda of this paper is to discuss about the significance and a detailed feasibility study of practical implementation of Smart Grid in Bangladesh. Smart grid refers to an electric power system that enhances grid reliability and efficiency by automatically responding to system disturbances. Power crisis is a major problem for a developing country like Bangladesh. Efficient transmission and distribution of electricity with essential energy resources is a fundamental requirement to provide citizens and economies. The paper analyzes the characteristics of Smart Grid and a comparative analysis with conventional grid system. It also discusses about the efficient transmission and distribution process which will integrate power system with renewable energy and information system. 展开更多
关键词 Smart grid integration of information and power system CENTRALIZED & Distributed Generation system Transmission and Distribution system Performance INDICATOR RENEWABLE Energy
下载PDF
Simulation and Analysis of a Compact Electronic Infrastructure for DC Micro-Grid: Necessity and Challenges
13
作者 Mohammad Ali Tavakkoli Ahmad Radan Houshang Hassibi 《Smart Grid and Renewable Energy》 2012年第2期73-82,共10页
Complex circuitry of electronic infrastructure of compact micro-grids with multiple renewable energy sources feeding the loads using parallel operation of inverters acts as a deterrent in developing such systems. This... Complex circuitry of electronic infrastructure of compact micro-grids with multiple renewable energy sources feeding the loads using parallel operation of inverters acts as a deterrent in developing such systems. This paper deals with applicable techniques reducing the driving circuits in parallel power inverters used in micro-grid system (MGS), mainly focused on the distributed generation (DG) in islanded mode. The method introduced in this paper, gives a minimal and compressed circuitry that can be implemented very cost-effectively with simple components. DC micro-grids are proposed and researched for the good connection with DC output type sources such as photovoltaic (PV), fuel cell, and secondary battery. In this paper, the electronic infrastructure of micro-grid is expressed. Then discussed the reasons for its complexity and the possibility of reducing the elements of electronic circuits are investigated. The reason for this is in order to compact DC micro-grid system for electrification to places like villages. Digital Simulation in Matlab Simulink is used to show the effectiveness of this novel driver topology for parallel operating inverters (NDTPI). 展开更多
关键词 Drive CIRCUITRY Integrated power ELECTRONICS MODULES MICRO-grid
下载PDF
UAV-Aided Data and Energy Integrated Network: System Design and Prototype Development
14
作者 Xinyu Fan Jie Hu Kun Yang 《China Communications》 SCIE CSCD 2023年第7期290-302,共13页
Terminal devices deployed in outdoor environments are facing a thorny problem of power supply.Data and energy integrated network(DEIN)is a promising technology to solve the problem,which simultaneously transfers data ... Terminal devices deployed in outdoor environments are facing a thorny problem of power supply.Data and energy integrated network(DEIN)is a promising technology to solve the problem,which simultaneously transfers data and energy through radio frequency signals.State-of-the-art researches mostly focus on theoretical aspects.By contrast,we provide a complete design and implementation of a fully functioning DEIN system with the support of an unmanned aerial vehicle(UAV).The UAV can be dispatched to areas of interest to remotely recharge batteryless terminals,while collecting essential information from them.Then,the UAV uploads the information to remote base stations.Our system verifies the feasibility of the DEIN in practical applications. 展开更多
关键词 data and energy integrated network(DEIN) internet of things(IoT) simultaneous wire-less information and power transfer(SWIPT) wireless energy transfer(WET) prototype
下载PDF
Rural power grid resources WebGIS technology research based on ArcIMS
15
作者 BAO Qing-peng ZHANG Xu +1 位作者 SU Zhong-bin ZHU Jia-mei 《科技视界》 2016年第6期67-68,70,共3页
Web GIS is a tendency of current geographical information system.Arcl MS is an excellent platform to construct Web GIS.This paper introduces the architecture,features and advantages of ArcI MS,which also builds a rura... Web GIS is a tendency of current geographical information system.Arcl MS is an excellent platform to construct Web GIS.This paper introduces the architecture,features and advantages of ArcI MS,which also builds a rural power resources information system based on ArcI MS.This system is a security assurance of reactive power optimization of distribution network,is an effective method of economic operation and is one of important measures to improve the voltage quality of distribution network.Applying ArcS DE to establish spatial database and transform the format of spatial data are key to realizing the system. 展开更多
关键词 网络地理信息系统 GIS 电力资源信息系统 科学技术
下载PDF
考虑耦合作用的电网业务组合投资优化
16
作者 王永利 马子奔 +2 位作者 秦雨萌 卢艳超 蔺媛 《中国电力》 CSCD 北大核心 2024年第3期197-205,共9页
电网业务正处于传统业务向新兴业务变革的关键时期,由于电网业务发展的多样性,应考虑业务的相互影响,准确量化业务投资价值。分析业务间耦合作用,构建业务耦合作用评价体系,并通过Choquet模糊积分量化了电网业务耦合程度,构建适应未来... 电网业务正处于传统业务向新兴业务变革的关键时期,由于电网业务发展的多样性,应考虑业务的相互影响,准确量化业务投资价值。分析业务间耦合作用,构建业务耦合作用评价体系,并通过Choquet模糊积分量化了电网业务耦合程度,构建适应未来发展新环境的电网业务投资价值评价体系,构建了考虑耦合作用的电网业务组合投资优化模型。在算例中,包含综合能源业务、储能业务、电动汽车业务的组合投资价值最高,为2.024,其中,业务基础投资价值为1.870,耦合投资价值为0.154。通过算例分析验证了考虑电网业务耦合作用的必要性与投资优化模型的适用性,支撑电网公司制定电网业务组合投资决策。 展开更多
关键词 电网业务 耦合作用 CHOQUET模糊积分 投资价值 投资优化
下载PDF
“人-车-桩-路-网”深度耦合下的配电网协同规划与运行优化
17
作者 穆云飞 金尚婷 +3 位作者 赵康宁 董晓红 贾宏杰 戚艳 《电力系统自动化》 EI CSCD 北大核心 2024年第7期24-37,共14页
电动汽车(EV)作为连接交通电气化和电网清洁化的纽带和桥梁,可实现电力-交通-信息之间的深度耦合,形成电力-交通一体化的规划及运行架构。配电-交通融合系统(DTIS)中,EV充放电行为多时空动态交织、电能流-交通流-信息流深度融合、多利... 电动汽车(EV)作为连接交通电气化和电网清洁化的纽带和桥梁,可实现电力-交通-信息之间的深度耦合,形成电力-交通一体化的规划及运行架构。配电-交通融合系统(DTIS)中,EV充放电行为多时空动态交织、电能流-交通流-信息流深度融合、多利益主体动态博弈等大量不确定性因素使配电网的规划及运行优化的边界都将发生重大转变,但同时也给挖掘利用EV的移动储能特性和提升配电网灵活性带来了契机。为此,在分析“人-车-桩-路-网”深度耦合下配电网的形态演化特征基础上,剖析了新形态下配电网协同规划与运行优化所面临的新挑战,进而针对“人-车-桩-路-网”耦合下的EV灵活性建模、灵活域高效构建及预测、协同规划、运行优化4个方面关键技术展开讨论,并对相关技术问题的研究方向进行了展望。 展开更多
关键词 电动汽车 电力-交通一体化 协同规划 运行优化 灵活域 多模态信息融合
下载PDF
基于广域信息分析的智能配电网故障自愈技术研究
18
作者 郭杉 贾俊青 思勤 《电子设计工程》 2024年第9期119-123,共5页
针对传统电网接地故障检测和自愈方法存在识别速度慢且精确度较低的问题,文中结合信号广域信息提出了一种配电网故障自愈方法。该方法构建了单相接地故障模型,并将零序电流作为分析的对象。将零序电流信号分解为时域、频域以及小波域分... 针对传统电网接地故障检测和自愈方法存在识别速度慢且精确度较低的问题,文中结合信号广域信息提出了一种配电网故障自愈方法。该方法构建了单相接地故障模型,并将零序电流作为分析的对象。将零序电流信号分解为时域、频域以及小波域分量来作为广域特征向量,并采用随机森林算法对其权重进行分类,利用LightGBM算法对分类后的广域特征向量加以训练,进而得到故障预测结果。在仿真测试中,所提算法能够抵抗过渡电阻与初始相位角变化对预测结果的影响,且其故障分析准确率的平均值为98.9%,在对比算法中为最优,表明该算法可为配电网故障自愈提供有效的技术支撑。 展开更多
关键词 广域信息 电网故障自愈 小波分析 随机森林 轻量级梯度提升机
下载PDF
基于信息间隙决策理论的含碳捕集−电转气综合能源系统优化调度
19
作者 赵振宇 包格日乐图 李炘薪 《发电技术》 CSCD 2024年第4期651-665,共15页
【目的】为科学统筹综合能源系统运行经济性、稳定性和低碳性优化目标,采用何种技术手段以提升能源转化效率,减少系统能源浪费和区域环境污染,是当下综合能源系统合理优化的主要问题。为此,提出一种基于场景生成与信息间隙决策理论的含... 【目的】为科学统筹综合能源系统运行经济性、稳定性和低碳性优化目标,采用何种技术手段以提升能源转化效率,减少系统能源浪费和区域环境污染,是当下综合能源系统合理优化的主要问题。为此,提出一种基于场景生成与信息间隙决策理论的含碳捕集与封存(carbon capture and storage,CCS)—两段式电转气(power to gas,P2G)综合能源系统低碳优化策略。【方法】在技术层面,通过对电P2G两阶段精细化建模,提高氢能利用效率,建立热电联产(combined heating and power,CHP)-CCS-P2G耦合模型;在市场机制层面,引入阶梯型碳交易模型以降低系统中CO_(2)排放量。最终,基于信息间隙决策理论(IGDT)构建不同风险偏好下的优化调度模型。【结果】以典型综合能源系统进行算例分析,仿真结果表明所提模型可提高风光消纳率,实现系统低碳、经济、稳定运行。【结论】该优化策略可有效帮助决策者根据其风险偏好制定风险规避与风险追求策略下的调度方案,实现系统不确定性与经济性的平衡。 展开更多
关键词 综合能源系统 场景生成 信息间隙决策理论(IGDT) 碳捕集与封存(CCS) 电转气(P2G) 阶梯型碳交易
下载PDF
基于图表映射融合技术的大电网运行业务平台化人机交互设计
20
作者 陈亦平 李凯航 +5 位作者 肖逸 陶薮元 杨若朴 李淳 颜融 张俊勃 《电气自动化》 2024年第5期44-46,共3页
为更好满足大电网运行业务中高效感知电网状态的需求,开展了软件前后端数据组织和接口设计方面的研究。在融合海量人机交互技术关键要素的基础上,提出一种大电网分析模型图模一体化与多关系表数据映射与融合的平台化技术方案,并通过266... 为更好满足大电网运行业务中高效感知电网状态的需求,开展了软件前后端数据组织和接口设计方面的研究。在融合海量人机交互技术关键要素的基础上,提出一种大电网分析模型图模一体化与多关系表数据映射与融合的平台化技术方案,并通过2669个厂站大电网案例验证方法的有效性。结果表明,所提方法在实现诸多功能需求基础上具备较高的模型检索效率与优秀的前端渲染性能,可为大电网运行业务人机交互设计提供参考。 展开更多
关键词 大电网运行业务 人机交互 图表映射融合技术 图模一体化 平台化
下载PDF
上一页 1 2 79 下一页 到第