期刊文献+
共找到42篇文章
< 1 2 3 >
每页显示 20 50 100
Intensity Modulated Proton Therapy for Re-Irradiation of Bulky Loco-Regional Recurrent Breast Cancer: A Case Report
1
作者 Bosco Giap Thorsten Ostrander +2 位作者 Angie Waldinger Fantine Giap Huan Giap 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2021年第1期1-11,共11页
Patients with recurrent breast cancer to chest wall, who had previous irradiation, are difficult to manage and have limited options. Several reports described the use of photon therapy, hyperthermia, and brachytherapy... Patients with recurrent breast cancer to chest wall, who had previous irradiation, are difficult to manage and have limited options. Several reports described the use of photon therapy, hyperthermia, and brachytherapy. This is a case report of a 72-year-old female with Stage IIIA (pT3N1M0) invasive ductal carcinoma of the right breast status post modified radical mastectomy. The patient developed recurrence to the chest wall and one internal mammary lymph node one year later. She received 3-D conformal photon radiation therapy for this recurrence. Two years later, she had progression of the recurrence at the right chest wall and axillary and internal mammary lymph nodes. She was treated with intensity modulated proton therapy (IMPT) for a total of 6600 cGy in 33 fractions. However, four months later, she was found to have biopsy-proven isolated metastatic disease at her right bicep, which was again treated with IMPT for a dose of 6000 cGy in 20 fractions. Proton beam therapy was used in this case to spare dose to the brachial plexus, heart and lung while optimally irradiating the recurrent tumors. At last follow up, the patient is alive and has been disease free for 39 months. This report describes the technique and dosimetry for this unique case, which also reviewed recent series of re-irradiation using proton beam. 展开更多
关键词 Proton Therapy Breast Cancer RE-IRRADIATION intensity modulated Proton Therapy
下载PDF
Subcarrier Intensity Modulated Optical Wireless Communications:A Survey from Communication Theory Perspective
2
作者 Md.Zoheb Hassan Md.Jahangir Hossain +1 位作者 Julian Cheng Victor C.M.Leung 《ZTE Communications》 2016年第2期2-12,共11页
Subcarrier intensity modulation with direet detection is a modulatiou/detection technique tbr optical wireless communication systems, where a pre-modulated and properly biased radio frequency signal is modulated on th... Subcarrier intensity modulation with direet detection is a modulatiou/detection technique tbr optical wireless communication systems, where a pre-modulated and properly biased radio frequency signal is modulated on the intensity of the optical carrier. The most important benefits of subcarrier intensity modulation are as follows: 1) it does not provide irreducible error floor like the conventional on-off keying intensity modulation with a fixed detection threshold; 2) it provides improved spectral efficiency and supports higher order modulation schemes; and 3) it has much less implementation complexity compared to coherent optical wireless communications with heterodyne or homodyne detection. In this paper, we present an up-to-date review of subcarrier intensity modulated optical wireless communication systems. We survey the error rate and outage performance of subcarrier intensity modulations in the atmospheric turbulence channels considering different modulation and coding schemes. We also explore different contemporary atmospheric turbulence fading mitigation solutions that can be employed for subcarrier intensity modulation. These solutions include diversity combining, adaptive transmission, relay assisted transmission, multiple-subcarrier intensity modulations, and optical orthogonal frequency division multiplexing. Moreover, we review the performance of subcarrier intensity modulations due to the pointing error and synchronization error. 展开更多
关键词 Atmospheric turbulence fading optical wireless communications subcarrier intensity modulation
下载PDF
Bidirectional intensity modulated/direct detection optical OFDM WDM-PON system
3
作者 Mahmoud Alhalabi Necmi Tasppnar Fady I.El-Nahal 《Optoelectronics Letters》 EI 2023年第2期83-87,共5页
In this paper, we have evaluated a bidirectional wavelength division multiplexing passive optical network(WDM-PON) employing intensity modulated/direct detection optical orthogonal frequency division multiplexing(IM/D... In this paper, we have evaluated a bidirectional wavelength division multiplexing passive optical network(WDM-PON) employing intensity modulated/direct detection optical orthogonal frequency division multiplexing(IM/DD-OFDM). The proposed system employs 100 Gbit/s 16 quadrature amplitude modulation(16-QAM) downstream and 5 Gbit/s on-off keying(OOK) upstream wavelengths, respectively. The proposed system is considered low-cost as non-coherent IM/DD OFDM technology and a simple reflective semiconductor optical amplifier(RSOA) colorless transmitter are employed and no dispersion compensating fiber(DCF) is needed. Based on the bit error rate(BER) results of WDM signals, the proposed WDM-PON system can achieve up to 1.6 Tbit/s(100 Gbit/s/λ × 16 wavelengths) downstream transmission over a 30 km single mode fiber(SMF). 展开更多
关键词 WDM PON Bidirectional intensity modulated/direct detection optical OFDM WDM-PON system
原文传递
Intensity modulated silver coated glass optical fiber refractive index sensor
4
作者 Zahra Samavati Alireza Samavati +2 位作者 A.F.Ismail Mukhlis A.Rahman M.H.D.Othman 《Chinese Optics Letters》 SCIE EI CAS CSCD 2018年第9期16-21,共6页
Miniature optical fiber sensors with thin films as sensitive elements could open new fields for optical fiber sensor applications. Thin films work as sensitive elements and a transducer to get response and feedback fr... Miniature optical fiber sensors with thin films as sensitive elements could open new fields for optical fiber sensor applications. Thin films work as sensitive elements and a transducer to get response and feedback from environments, in which optical fibers act as a signal carrier. A novel Ag coated intensity modulated optical fiber sensor based on refractive index changes using IR and UV-Vis (UV-visible) light sources is proposed. The sensor with an IR light source has higher sensitivity compared to a UV-Vis source. When the refractive index is en- hanced to 1.38, the normalized intensity of IR and UV-Vis light diminishes to 0.2 and 0.8. respectively. 展开更多
关键词 UV intensity modulated silver coated glass optical fiber refractive index sensor AG
原文传递
Prostate specific antigen bounce after intensity-modulated radiation therapy in an Asian population
5
作者 Yu Guang Tan Weber Lau Kam On +1 位作者 Hong Hong Huang Terence Tan Wee Kiat 《Asian Journal of Urology》 2016年第2期59-63,共5页
Objective:Serum prostate specific antigen(PSA)is commonly used to evaluate treatment response after definitive radiation therapy(RT).However,PSA levels can temporarily rise without a clear reason,termed“PSA bounce”,... Objective:Serum prostate specific antigen(PSA)is commonly used to evaluate treatment response after definitive radiation therapy(RT).However,PSA levels can temporarily rise without a clear reason,termed“PSA bounce”,and often engender great anxiety for both patients and physicians.The present study aimed to determine the prevalence and factors that predict“PSA bounce”after intensity-modulated radiation therapy(IMRT),and the relevance to biochemical failure and cancer recurrence in an Asian population.Methods:We retrospectively reviewed 206 patients who received IMRT for prostate cancer from 2004 to 2012 in the National Cancer Centre Singapore.These patients were followed up with regular PSA monitoring.We defined“PSA bounce”as a rise of 0.1 ng/mL,followed by two consecutive falls.Patients with biochemical failure(PSA nadir t 2 ng/mL)were further evaluated for cancer recurrence.Results:Sixty-one patients(29.6%)experienced“PSA bounce”,at a median time of 16 months and lasted for 12 months.Age remained the most consistent predictor of the incidence,duration and extent of“PSA bounce”.Other contributory factors included baseline PSA,Gleason score and PSA nadir.Hormonal therapy and prostate volume did not affect this phenomenon.Sixteen patients(7.8%)developed biochemical recurrence,at median time of 32 months,of which 11 were confirmed to have metastatic disease.The median follow-up time was 71 months. 展开更多
关键词 Prostate specific antigen Prostate specific antigen bounce Prostate cancer intensity modulated radiation therapy
下载PDF
Unraveling the efficacy network: A network meta-analysis of adjuvant external beam radiation therapy methods after hepatectomy
6
作者 Gao-Yuan Yang Zhi-Wei He +7 位作者 Yong-Chang Tang Feng Yuan Ming-Bo Cao Yu-Peng Ren Yu-Xuan Li Xiao-Rui Su Zhi-Cheng Yao Mei-Hai Deng 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第1期205-214,共10页
BACKGROUND Primary liver cancer is a malignant tumor with a high recurrence rate that significantly affects patient prognosis.Postoperative adjuvant external radiation therapy(RT)has been shown to effectively prevent ... BACKGROUND Primary liver cancer is a malignant tumor with a high recurrence rate that significantly affects patient prognosis.Postoperative adjuvant external radiation therapy(RT)has been shown to effectively prevent recurrence after liver cancer resection.However,there are multiple RT techniques available,and the differ-ential effects of these techniques in preventing postoperative liver cancer re-currence require further investigation.AIM To assess the advantages and disadvantages of various adjuvant external RT methods after liver resection based on overall survival(OS)and disease-free survival(DFS)and to determine the optimal strategy.METHODS This study involved network meta-analyses and followed the PRISMA guidelines.The data of qualified studies published before July 10,2023,were collected from PubMed,Embase,the Web of Science,and the Cochrane Library.We included relevant studies on postoperative external beam RT after liver resection that had OS and DFS as the primary endpoints.The magnitudes of the effects were determined using risk ratios with 95%confidential intervals.The results were analyzed using R software and STATA software.RESULTS A total of 12 studies,including 1265 patients with hepatocellular carcinoma(HCC)after liver resection,were included in this study.There was no significant heterogeneity in the direct paired comparisons,and there were no significant differences in the inclusion or exclusion criteria,intervention measures,or outcome indicators,meeting the assumptions of heterogeneity and transitivity.OS analysis revealed that patients who underwent stereotactic body radiotherapy(SBRT)after resection had longer OS than those who underwent intensity modulated radiotherapy(IMRT)or 3-dimensional conformal RT(3D-CRT).DFS analysis revealed that patients who underwent 3D-CRT after resection had the longest DFS.Patients who underwent IMRT after resection had longer OS than those who underwent 3D-CRT and longer DFS than those who underwent SBRT.CONCLUSION HCC patients who undergo liver cancer resection must consider distinct advantages and disadvantages when choosing between SBRT and 3D-CRT.IMRT,a RT technique that is associated with longer OS than 3D-CRT and longer DFS than SBRT,may be a preferred option. 展开更多
关键词 Primary liver cancer Hepatocellular carcinoma Network meta-analysis External beam radiation therapy Stereotactic body radiotherapy intensity modulated radiotherapy
下载PDF
Helical tomotherapy and volumetric modulated arc therapy:New therapeutic arms in the breast cancer radiotherapy 被引量:7
7
作者 Olivier Lauche Youlia M Kirova +8 位作者 Pascal Fenoglietto Emilie Costa Claire Lemanski Celine Bourgier Olivier Riou David Tiberi Francois Campana Alain Fourquet David Azria 《World Journal of Radiology》 CAS 2016年第8期735-742,共8页
AIM To analyse clinical and dosimetric results of helical tomotherapy(HT) and volumetric modulated arc therapy(VMAT) in complex adjuvant breast and nodes irradiation.METHODS Seventy-three patients were included(31 HT ... AIM To analyse clinical and dosimetric results of helical tomotherapy(HT) and volumetric modulated arc therapy(VMAT) in complex adjuvant breast and nodes irradiation.METHODS Seventy-three patients were included(31 HT and 42 VMAT). Dose were 63.8 Gy(HT) and 63.2 Gy(VMAT) in the tumour bed, 52.2 Gy in the breast, 50.4 Gy in supraclavicular nodes(SCN) and internal mammary chain(IMC) with HT and 52.2 Gy and 49.3 Gy in IMC and SCN with VMAT in 29 fractions. Margins to particle tracking velocimetry were greater in the VMAT cohort(7 mm vs 5 mm).RESULTS For the HT cohort, the coverage of clinical target volumes was as follows: Tumour bed: 99.4% ± 2.4%; breast: 98.4% ± 4.3%; SCN: 99.5% ± 1.2%; IMC:96.5% ± 13.9%. For the VMAT cohort, the coverage was as follows: Tumour bed: 99.7% ± 0.5%, breast: 99.3% ± 0.7%; SCN: 99.6% ± 1.4%; IMC: 99.3% ± 3%. For ipsilateral lung, Dmean and V20 were 13.6 ± 1.2 Gy, 21.1% ± 5%(HT) and 13.6 ± 1.4 Gy, 20.1% ± 3.2%(VMAT). Dmean and V30 of the heart were 7.4 ± 1.4 Gy, 1% ± 1%(HT) and 10.3 ± 4.2 Gy, 2.5% ± 3.9%(VMAT). For controlateral breast Dmean was 3.6 ± 0.2 Gy(HT) and 4.6 ± 0.9 Gy(VMAT). Acute skin toxicity grade 3 was 5% in the two cohorts.CONCLUSION HT and VMAT in complex adjuvant breast irradiation allow a good coverage of target volumes with an acceptable acute tolerance. A longer follow-up is needed to assess the impact of low doses to healthy tissues. 展开更多
关键词 Three-dimensional conformal radiotherapy intensity modulated radiation therapy TOXICITY Helical tomotherapy Volumetric modulated arc therapy Breast cancer radiotherapy
下载PDF
Intensity modulation characters of orthogonally polarized HeNe lasers with different optical feedback level 被引量:2
8
作者 崔柳 张书练 万新军 《Chinese Physics B》 SCIE EI CAS CSCD 2008年第2期644-648,共5页
This paper demonstrates the intensity modulation characters of orthogonally polarized HeNe lasers with different optical feedback level generated by the variable reflectivity of external reflector. The modulation dept... This paper demonstrates the intensity modulation characters of orthogonally polarized HeNe lasers with different optical feedback level generated by the variable reflectivity of external reflector. The modulation depths of the orthogonally polarized frequencies are increased when the optical feedback level becomes strong. It also observes that the modulation amplitudes are different for different external cavity length. Based on the vectorial extension of Lamb's semi-classical theory, it finds that the calculations are consistent with the experimental results. 展开更多
关键词 intensity modulation optical feedback frequency split
下载PDF
Measurement of Frequency Shift Characteristics Based on LiNbO_3 Waveguide Electro-Optic Intensity Modulator 被引量:1
9
作者 Zhou Meng Hui-Juan Zhou Yi Liao Qiong Yao 《Journal of Electronic Science and Technology of China》 2008年第4期449-452,共4页
High-speed and wide-band LiNbO3 waveguide electro-optic intensity modulator has drawn great attention in the field of optical fiber communication and sensor. This paper reports the research results on the measurement ... High-speed and wide-band LiNbO3 waveguide electro-optic intensity modulator has drawn great attention in the field of optical fiber communication and sensor. This paper reports the research results on the measurement of frequency shift characteristics of Mach-Zehnder electro-optic intensity modulator. Two measurement methods of frequency shift characteristics for high and low frequency modulations are studied in theory and experiment and demonstrate different results. The realization of a multi-wavelength optical source based on Mach-Zehnder electro-optic intensity modulator has been introduced. The technique to reach the maximum intensity for interesting shift frequency, particularly for heterodyne detection of Brillouin distributed optical fiber sensing, has been given. 展开更多
关键词 BRILLOUIN electro-optic intensity modulator frequency shift LiNbO3.
下载PDF
Magneto and Electro-Optic Intensity Modulator Based on Liquid Crystal and Magnetic Fluid Filled Photonic Crystal Fiber
10
作者 吕月兰 王斐儒 +4 位作者 张弛 尹辑文 黄玉 孙伟民 刘永军 《Chinese Physics Letters》 SCIE CAS CSCD 2018年第10期36-39,共4页
We propose a novel light intensity modulator based on magnetic fluid and liquid crystal(LC) filled photonic crystal fibers(PCFs). The influences of electric and magnetic fields on the transmission intensity are th... We propose a novel light intensity modulator based on magnetic fluid and liquid crystal(LC) filled photonic crystal fibers(PCFs). The influences of electric and magnetic fields on the transmission intensity are theoretically and experimentally analyzed and investigated. Both the electric and magnetic fields can manipulate the molecular arrangement of LC to array a certain angle without changing the refractive index of the LC. Therefore, light loss in the PCF varies with the electric and magnetic fields whereas the peak wavelengths remain constant. The experimental results show that the transmission intensity decreases with the increase of the electric and magnetic fields. The cut-off electric field is 0.899 V/um at 20 Hz and the cut-off magnetic field is 195 m T. This simple and compacted optical modulator will have a great prospect in sensing applications. 展开更多
关键词 PCF LC Magneto and Electro-Optic intensity Modulator Based on Liquid Crystal and Magnetic Fluid Filled Photonic Crystal Fiber
下载PDF
Design of a Reflective Intensity Optical Fibre Bundle Displacement Sensor
11
作者 Binghui Jia Jing Yu +2 位作者 Yong Feng Min Zhang Gang Li 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2020年第4期84-96,共13页
Optical fibre sensor has the advantages of small size,light weight,anti⁃electromagnetic interference,and high measurement accuracy,which has important applications in research and industrial production.To design an op... Optical fibre sensor has the advantages of small size,light weight,anti⁃electromagnetic interference,and high measurement accuracy,which has important applications in research and industrial production.To design an optical fibre displacement sensor(OFBDS)with simple structure and high measurement accuracy,the unified model of the commonly used OFBDS structures was proposed and the feasibility of the intensity⁃modulation of multi⁃structural optical fibre bundles was analysed based on the arrangement characteristics of the fibre bundle end⁃face.The intensity⁃modulation characteristic of different fibre bundles was analysed,and the single coil coaxial fibre bundle was chosen as the fibre probe in this study.The sensor hardware system was designed.Lastly,the calibration experiment,temperature interference experiment,changes of measured plane surface area,and the dynamic experiment were conducted.Results showed that the sensor linear measurement range was about 3 mm,and the sensor system had excellent static and dynamic characteristics. 展开更多
关键词 optical fibre bundle displacement sensor intensity⁃modulation characteristic static experiment dynamic experiment
下载PDF
Comparative Study between Patients Treated with Conventional Radiotherapy and IMRT with Chemotherapy for Stage III - IVA Nasopharyngeal Carcinoma: A Single Institution Retrospective Report
12
作者 Mamady Keita Juan Li +6 位作者 Malick Bah Mamadou Aliou Diallo Alhassane Ismaël Touré Abou Camara Bangaly Traoré Abdoulaye Keita Wenbing Shen 《Journal of Cancer Therapy》 2023年第12期451-464,共14页
Introduction: Nasopharyngeal carcinomas are the most radiation-sensitive tumours, and radiotherapy alone provides better local control. Objectives: To evaluate the clinical efficacy and acute and late toxicities of tw... Introduction: Nasopharyngeal carcinomas are the most radiation-sensitive tumours, and radiotherapy alone provides better local control. Objectives: To evaluate the clinical efficacy and acute and late toxicities of two different treatment regimens for locally advanced nasopharyngeal carcinoma. Methods: From 2014 to 2017, 150 cases of stage III and 68 cases of stage IVA nasopharyngeal carcinoma were treated. Of these, 137 received conventional radiotherapy plus chemotherapy, and 81 received intensity-modulated radiotherapy plus chemotherapy. Chemotherapy was given either as induction, concurrent or adjuvant therapy. Survival rates were calculated according to Kaplan Meier and compared with the Log-rank test. The RTOG or EORTC criteria were used to assess acute and late toxicities. Results: The median follow-up time was 21.5 months, and the 2-year locoregional relapse-free survival, distant metastases-free survival, and overall survival rates in the conventional radiotherapy plus chemotherapy group were 76%, 71% and 77%, respectively;in the intensity-modulated radiotherapy plus chemotherapy group, they were 97%, 84%, and 100%, respectively. The difference in survival between the two groups was significant (χ<sup>2</sup> = 5.06, P = 0.028). The incidence of grade 2 and 3 xerostomia one year after radiotherapy was 45.1% and 30.9% versus 33.3% and 0%. Conclusion: Compared with conventional radiotherapy plus chemotherapy, intensity-modulated radiotherapy plus chemotherapy offers better locoregional relapse-free survival and overall survival in patients with stage III and IVA nasopharyngeal carcinoma, and may significantly reduce the occurrence of radiation-induced xerostomia. 展开更多
关键词 Nasopharyngeal Carcinoma Conventional Radiotherapy intensity modulated Radiotherapy CHEMOTHERAPY PROGNOSIS
下载PDF
Dosimetric comparison between helical tomotherapy and intensity-modulated radiation therapy plans for non-small cell lung cancer 被引量:4
13
作者 MENG Ling-ling FENG Lin-chun WANG Yun-lai DAI Xiang-kun XIE Chuan-bin 《Chinese Medical Journal》 SCIE CAS CSCD 2011年第11期1667-1671,共5页
Background Helical tomotherapy (HT) is a new image-guided intensity-modulated radiation therapy (IMRT) technique. It is reported that HT plan for non-small-cell lung cancer (NSCLC) can give better dose uniformit... Background Helical tomotherapy (HT) is a new image-guided intensity-modulated radiation therapy (IMRT) technique. It is reported that HT plan for non-small-cell lung cancer (NSCLC) can give better dose uniformity, dose gradients, and protection for the lung than IMRT plan. We compared the dosimetric characteristics of HT for NSCLC with those of conventional IMRT to observe the superiority of HT. Methods There was a comparative case series comprising 10 patients with NSCLC. Computed tomographic (CT) images of delineated targets were transferred to the PrecisePlan planning system (IMRT) and Tomo planning system (HT). The prescription doses were 70 Gy/33F for the gross tumor volume (GTV) and the visible lymph nodes (GTVnd), 展开更多
关键词 helical tomotherapy intensity modulated radiotherapy non-small-cell lung cancer DOSIMETRY
原文传递
The role of radiotherapy in localised and locally advanced prostate cancer 被引量:5
14
作者 Michel Bolla Ann Henry +1 位作者 Malcom Mason Thomas Wiegel 《Asian Journal of Urology》 CSCD 2019年第2期153-161,共9页
For a patient suffering from non-metastatic prostate cancer,the individualized recommendation of radiotherapy has to be the fruit of a multidisciplinary approach in the context of a Tumor Board,to be explained careful... For a patient suffering from non-metastatic prostate cancer,the individualized recommendation of radiotherapy has to be the fruit of a multidisciplinary approach in the context of a Tumor Board,to be explained carefully to the patient to obtain his informed consent.External beam radiotherapy is now delivered by intensity modulated radiotherapy,considered as the gold standard.From a radiotherapy perspective,low-risk localized prostate cancer is treated by image guided intensity modulated radiotherapy,or brachytherapy if patients meet the required eligibility criteria.Intermediate-risk patients may benefit from intensity modulated radiotherapy combined with 4e6 months of androgen deprivation therapy;intensity modulated radiotherapy alone or combined with brachytherapy can be offered to patients unsuitable for androgen deprivation therapy due to co-morbidities or unwilling to accept it to preserve their sexual health.High-risk prostate cancer,i.e.high-risk localized and locally advanced prostate cancer,requires intensity modulated radiotherapy with long-term(≥2 years)androgen deprivation therapy with luteinizing hormone releasing hormone agonists.Post-operative irradiation,either immediate or early deferred,is proposed to patients classified as pT3pN0,based on surgical margins,prostate-specific antigen values and quality of life.Whatever the techniques and their degree of sophistication,quality assurance plays a major role in the management of radiotherapy,requiring the involvement of physicians,physicists,dosimetrists,radiation technologists and computer scientists.The patients must be informed about the potential morbidity of radiotherapy and androgen deprivation therapy and followed regularly during and after treatment for tertiary prevention and evaluation.A close cooperation is needed with general practitioners and specialists to prevent and mitigate side effects and maintain quality of life. 展开更多
关键词 Localized prostate cancer Locally advanced prostate cancer BRACHYTHERAPY intensity modulated radiotherapy Short-term and longterm androgen deprivation therapy
下载PDF
Dose Distribution Verifications of IMRT for NPC 被引量:1
15
作者 李勤 李良 +1 位作者 韩军 梁志文 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2009年第5期673-676,共4页
In order to explore a dose distribution verification procedure of intensity modulated radiation therapy (IMRT) for nasopharyngeal carcinoma (NPC) and establish its evaluation criteria, we performed 35 two-dimensio... In order to explore a dose distribution verification procedure of intensity modulated radiation therapy (IMRT) for nasopharyngeal carcinoma (NPC) and establish its evaluation criteria, we performed 35 two-dimensional (2D) patient-specific IMRT verifications over the year i006. The percent of pixels passing 7 and the normalized agreement test (NAT) index were mainly used to represent the agreement between the measured and computed dose distributions with three criteria (2%/2 mm, 3%/3 mm and 5%/3 mm) as recommended in the literature. The results were that all cases passed through verifications with three criteria except that the NAT index of one case was beyond the limitation, and the three tolerance levels of 2%/2mm, 3%/3 mm and 5%/3 mm produced similar clinical verification results but led to different percent of pixels passing Y and NAT index. Our data showed that the percent of pixels passing y and the NAT index were complementary to evaluate future IMRT verifications as two significant metrics. Due to the influence of the noise and the trait of the software, we considered an IMRT plan as acceptable in case of the percent ofpixels passing y 〉95% and the NAT index 〈5 with the 5%/3 mm criteria for IMRT patient-specific quality assurance (QA). 展开更多
关键词 dose distribution dose verification intensity modulated radiation therapy
下载PDF
Treatment of Massive Low-Grade Chondrosarcoma of Nasal Septum with Helical Tomotherapy: A Case Report 被引量:1
16
作者 Hamit Basaran Timur Koca +10 位作者 Sibel Karaca Ozlem Eser K&iota l&iota nc Fikriye Gul Karauc Okan Ö zdemir Ozan Kuduban Arzu Tatar Sare Ş ipal 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2016年第4期263-269,共7页
Chondrosarcomas are malignant bone tumors which develop as a cartilaginous differentiation of primary mesenchymal cells and the second most frequently seen malignant tumor of the bone after osteosarcoma. These maligna... Chondrosarcomas are malignant bone tumors which develop as a cartilaginous differentiation of primary mesenchymal cells and the second most frequently seen malignant tumor of the bone after osteosarcoma. These malignancies are slowly growing non-epithelial tumors with unknown etiology and most frequently seen during the 4 decades of life. They are frequently localized on pelvis, ribs and long bones. Nasal septum CSs are very rarely seen malignancies. They originate from septal mucosa or cartilage and it is difficult to make a diagnosis unless they reach a certain size. A few cases of CSs with nasal septum have been reported in the literature. In cases of CSs, surgery is the gold standard treatment modality;however in surgically unresectable cases or close to margins, radiotherapy plays a significant role in primary and adjuvant treatment. Based on the position of the tumor in head and neck and extremely closeness of the tumor to vital organs as optic nerve, chiasm and brain, image guided-intensity modulated radiation therapy (IG-IMRT) becomes very effective and reliable modalities and may be a favorable treatment alternative. 展开更多
关键词 CHONDROSARCOMA Image Guided intensity modulated Radiation Therapy
下载PDF
Neoadjuvant chemoradiotherapy for locally advanced gastric cancer with bulky lymph node metastasis:Five case reports
17
作者 Eiji Nomura Hajime Kayano +5 位作者 Takashi Machida Hideki Izumi Soichiro Yamamoto Akitomo Sugawara Masaya Mukai Terumitsu Hasebe 《World Journal of Clinical Cases》 SCIE 2020年第18期4177-4185,共9页
BACKGROUND Neoadjuvant chemoradiotherapy(NACRT)has not been accepted as a general therapy for gastric cancer because of its localized effect and toxicity for radiosensitive organs.However,if radiation therapy could co... BACKGROUND Neoadjuvant chemoradiotherapy(NACRT)has not been accepted as a general therapy for gastric cancer because of its localized effect and toxicity for radiosensitive organs.However,if radiation therapy could compensate for the limited or inadequate treatment choices available for elderly patients and/or those at high risk,the available therapeutic options for advanced gastric cancer might increase.From this perspective,we present our experiences of five patients with advanced gastric cancer in whom we used NACRT therapy with interesting results.CASE SUMMARY We admitted five patients with clinical Stage III gastric cancer and bulky lymph node metastasis or adjacent organ invasion at the time of diagnosis.A total of 50 Gy of preoperative intensity modulated radiation therapy was delivered to the patients in doses of 2.0 Gy/d,together with a regimen of concomitant chemotherapy comprising two courses of oral tegafur/gimeracil/oteracil(S-1;65 mg/m2 per day)for three consecutive weeks followed by two weeks of rest,starting at the same time as radiotherapy.All patients underwent no residual tumor resection and a pathological complete response of the primary tumors was achieved in two patients.The incidence of hematological toxicity was low,although the digestive toxicities of anorexia and diarrhea developed in three of the five patients,necessitating termination of radiation therapy at 30 Gy and S-1 at three weeks.However,even 30 Gy of irradiation and half the dose of S-1 resulted in sufficient downstaging,indicating that even a reduced amount of NACRT could confer considerable effects.CONCLUSION Slightly reduced NACRT might be useful and safe for patients with locally advanced gastric cancer. 展开更多
关键词 Advanced gastric cancer Neoadjuvant chemoradiotherapy intensity modulated radiation therapy Tegafur/gimeracil/oteracil Curative resection Case report GASTRECTOMY
下载PDF
Proton beam therapy of periorbital sinonasal squamous cell carcinoma: Two case reports and review of literature
18
作者 Yi-Lan Lin 《World Journal of Clinical Oncology》 CAS 2020年第8期655-672,共18页
BACKGROUND Sinonasal malignancies are rare but demanding due to complex anatomy,usually late diagnosis,and inconsistent therapy strategy based on multimodality approaches.Squamous cell carcinoma(SCC)is the most common... BACKGROUND Sinonasal malignancies are rare but demanding due to complex anatomy,usually late diagnosis,and inconsistent therapy strategy based on multimodality approaches.Squamous cell carcinoma(SCC)is the most common histology,with poorer prognosis.In the setting of orbital invasion,an orbital exenteration may be required.However,in case of primary rejection of disfiguring surgery or unresectable disease,proton beam therapy(PBT)should be largely considered,allowing for better sparing of neighboring critical structures and improved outcomes by dose escalation.CASE SUMMARY A 62-year-old male presented with a recurrent SCC in the nasal septum abutting frontal skull base and bilateral orbits at 7 mo after primary partial nasal amputation.Because of refusal of face-deforming surgery and considerable adverse effects of conventional radiotherapy,the patient underwent a PBT by hyperfractionated accelerated scheme,resulting in complete response and moderate toxicities.After 2 years,a nasal reconstruction was implemented with satisfactory appearance and recurrence-freedom to date.Another patient with an initially extended sinonasal SCC,invading right orbit and facial soft tissue,declined an orbital exenteration and was treated with a normofractionated PBT to the gross tumor and elective cervical lymphatics.The follow-up showed a continuous tumor remission with reasonable late toxicities,such as cataract and telangiectasia on the right.Despite T4a stage and disapproval of concurrent chemotherapy owing to individual choice,both patients still achieved outstanding treatment outcomes with PBT alone.CONCLUSION PBT enabled orbit preservation and excellent tumor control without severe adverse effects on both presented patients with locally advanced sinonasal SCC. 展开更多
关键词 Proton beam therapy intensity modulated proton therapy Sinonasal malignancies Squamous cell carcinoma Orbital exenteration Case report
下载PDF
Radiation Oncology and Medical Devices( Part 1)
19
作者 岳宁 陈霆 邹薇 《中国医疗设备》 2014年第1期1-9,共9页
Modern radiation treatments have become fairly complex and involve in utilizing a variety of medical devices to achieve the goal of providing conformal radiation dose coverage to the tumor target(s)while maximizing th... Modern radiation treatments have become fairly complex and involve in utilizing a variety of medical devices to achieve the goal of providing conformal radiation dose coverage to the tumor target(s)while maximizing the sparing of normal organ structures.Recently,different forms of linear accelerators/radioactive source based machines have been invented and developed with the aim of providing improved treatments and more treatment options.Besides linear accelerators(Linac)that have been undergoing constant improvement and advancement and can deliver fairly complicated dose distribution patterns,imaging systems,computer information and calculation systems have been more and more integrated into radiotherapy processes.To bring radiotherapy to a potentially higher level,many institutions have either acquired or started to consider particle therapy,especially proton therapy.The complexity of modern radiotherapy demands in-depth understanding of radiation physics and machine engineering as well as computer information systems.This paper is intended to provide an introductory description of radiation oncology and related procedures,and to provide an overview of the current status of medical devices in radiotherapy in the United States of America.This paper covers the radiation delivery systems,imaging systems,treatment planning systems,record and verify systems,and QA systems. 展开更多
关键词 radiation oncology RADIOTHERAPY external beam radiotherapy BRACHYTHERAPY intensity modulated radiotherapy SRS SBRT LINAC treatment planning system record and verify system 3DCRT simulator
下载PDF
Radiation Oncology and Medical Devices(Part 2)
20
作者 Ning J.Yue Ting Chen Wei Zou 《中国医疗设备》 2014年第2期1-10,共10页
Radiation oncology is one of the three major treatment modalities to manage cancer patient cares,and is a discipline mainly driven by technology and medical devices.Modern radiation treatments have become fairly compl... Radiation oncology is one of the three major treatment modalities to manage cancer patient cares,and is a discipline mainly driven by technology and medical devices.Modern radiation treatments have become fairly complex and involve in utilizing a variety of medical devices to achieve the goal of providing conformal radiation dose coverage to the tumor target(s)while maximizing the sparing of normal organ structures.Recently,different forms of linear accelerators/radioactive source based machines have been invented and developed with the aim of providing improved treatments and more treatment options.Besides linear accelerators(Linac)that have been undergoing constant improvement and advancement and can deliver fairly complicated dose distribution patterns,imaging systems,computer information and calculation systems have been more and more integrated into radiotherapy processes.To bring radiotherapy to a potentially higher level,many institutions have either acquired or started to consider particle therapy,especially proton therapy.The complexity of modern radiotherapy demands in-depth understanding of radiation physics and machine engineering as well as computer information systems.This paper is intended to provide an introductory description of radiation oncology and related procedures,and to provide an overview of the current status of medical devices in radiotherapy in the United States of America.This paper covers the radiation delivery systems,imaging systems,treatment planning systems,record and verify systems,and QA systems. 展开更多
关键词 radiation oncology RADIOTHERAPY external beam radiotherapy BRACHYTHERAPY intensity modulated radiotherapy SRS SBRT LINAC treatment planning system record and verify system 3DCRT Simulator
下载PDF
上一页 1 2 3 下一页 到第
使用帮助 返回顶部