For a Hanbury Brown and Twiss system, the influence of relative motion between the object and the detection plane on the resolution of second-order intensity-correlated imaging is investigated. The analytical results,...For a Hanbury Brown and Twiss system, the influence of relative motion between the object and the detection plane on the resolution of second-order intensity-correlated imaging is investigated. The analytical results, which are backed up by experiments, demonstrate that the amplitude and mode of the object's motion have no effect on the second-order intensity-correlated imaging and that high-resolution imaging can be always achieved by using a phase-retrieval method from the diffraction patterns. The use of motion de-blurring imaging for this approach is also discussed.展开更多
An enhancement method of rapid lifetime determination is proposed for time-resolved fluorescence imaging to discriminate substances with approximate fluorescence lifetime in forensic examination. In the method, an ima...An enhancement method of rapid lifetime determination is proposed for time-resolved fluorescence imaging to discriminate substances with approximate fluorescence lifetime in forensic examination. In the method, an image-exclusive-OR treatment with filter threshold adaptively chosen is presented to extract the region of interest from dual-gated fluorescence intensity images, and then the fluorescence lifetime image is reconstructed based on the rapid lifetime determination algorithm. Furthermore, a maximum and minimum threshold filtering is developed to automatically realize visualization enhancement of the lifetime image. In proof experiments, compared with traditional fluorescence intensity imaging and rapid lifetime determination method, the proposed method automatically distinguishes altered and obliterated documents written by two brands of highlighters with the same color and close fluorescence lifetime.展开更多
基金supported by the National 863 Program of China(No.2013AA122901)the National Natural Science Foundation of China(No.61571427)the Youth Innovation Promotion Association CAS(No.2013162)
文摘For a Hanbury Brown and Twiss system, the influence of relative motion between the object and the detection plane on the resolution of second-order intensity-correlated imaging is investigated. The analytical results, which are backed up by experiments, demonstrate that the amplitude and mode of the object's motion have no effect on the second-order intensity-correlated imaging and that high-resolution imaging can be always achieved by using a phase-retrieval method from the diffraction patterns. The use of motion de-blurring imaging for this approach is also discussed.
基金supported by the National Natural Science Foundation of China (NSFC) (No. U1736101)the Youth Innovation Promotion Association CAS (No. 2017155)。
文摘An enhancement method of rapid lifetime determination is proposed for time-resolved fluorescence imaging to discriminate substances with approximate fluorescence lifetime in forensic examination. In the method, an image-exclusive-OR treatment with filter threshold adaptively chosen is presented to extract the region of interest from dual-gated fluorescence intensity images, and then the fluorescence lifetime image is reconstructed based on the rapid lifetime determination algorithm. Furthermore, a maximum and minimum threshold filtering is developed to automatically realize visualization enhancement of the lifetime image. In proof experiments, compared with traditional fluorescence intensity imaging and rapid lifetime determination method, the proposed method automatically distinguishes altered and obliterated documents written by two brands of highlighters with the same color and close fluorescence lifetime.