期刊文献+
共找到4,974篇文章
< 1 2 249 >
每页显示 20 50 100
Inter-stage performance and energy characteristics analysis of electric submersible pump based on entropy production theory
1
作者 Hui Wang Yang Yang +5 位作者 Bin Xi Wei-Dong Shi Chuan Wang Lei-Lei Ji Xiang-Yu Song Zhao-Ming He 《Petroleum Science》 SCIE EI CAS CSCD 2024年第2期1354-1368,共15页
The electric submersible pump(ESP) is a crucial apparatus utilized for lifting in the oil extraction process.Its lifting capacity is enhanced by the multi-stage tandem structure, but variations in energy characteristi... The electric submersible pump(ESP) is a crucial apparatus utilized for lifting in the oil extraction process.Its lifting capacity is enhanced by the multi-stage tandem structure, but variations in energy characteristics and internal flow across stages are also introduced. In this study, the inter-stage variability of energy characteristics in ESP hydraulic systems is investigated through entropy production(EP) analysis,which incorporates numerical simulations and experimental validation. The EP theory facilitates the quantification of energy loss in each computational subdomain at all ESP stages, establishing a correlation between microscopic flow structure and energy dissipation within the system. Furthermore, the underlying causes of inter-stage variability in ESP hydraulic systems are examined, and the advantages and disadvantages of applying the EP theory in this context are evaluated. Consistent energy characteristics within the ESP, aligned with the distribution of internal flow structure, are provided by the EP theory, as demonstrated by our results. The EP theory also enables the quantitative analysis of internal flow losses and complements existing performance analysis methods to map the internal flow structure to hydraulic losses. Nonetheless, an inconsistency between the energy characterization based on EP theory and the traditional efficiency index when reflecting inter-stage differences is identified. This inconsistency arises from the exclusive focus of the EP theory on flow losses within the flow field, disregarding the quantification of external energy input to the flow field. This study provides a reference for the optimization of EP theory in rotating machinery while deeply investigating the energy dissipation characteristics of multistage hydraulic system, which has certain theoretical and practical significance. 展开更多
关键词 Electric submersible pump(ESP) Entropy production theory Energy characteristics inter-stage differences
下载PDF
Inter-stage line ratio of He- and Li-like Ti emissions for the electron temperature measurement
2
作者 李向东 王成 +1 位作者 韩申生 徐至展 《Plasma Science and Technology》 SCIE EI CAS CSCD 2005年第2期2764-2766,共3页
Under coronal conditions, the steady state rate-equations are used to calculate the inter-stage line ratios between Li-like ls22p(2P3/2)→ls22s(2S1/2) and He-like ls2p(1P1)→1s2(1S0) transitions for Ti in the electron... Under coronal conditions, the steady state rate-equations are used to calculate the inter-stage line ratios between Li-like ls22p(2P3/2)→ls22s(2S1/2) and He-like ls2p(1P1)→1s2(1S0) transitions for Ti in the electronic temperature ranges from 0.1keV to 20 keV. The results show that the temperature sensitivities are higher at the electronic temperature less than 5000 eV and the temperature sensitivities will decrease with the increase of electronic temperature. 展开更多
关键词 inter-stage line ratio electron temperature measurement Li-like ion
下载PDF
Influence of syngas components and ash particles on the radiative heat transfer in a radiant syngas cooler
3
作者 Chen Han Youmin Situ +4 位作者 Huaxing Zhu Jianliang Xu Zhenghua Dai Guangsuo Yu Haifeng Liu 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2024年第4期203-215,共13页
Radiant syngas cooler(RSC)is widely used as a waste heat recovery equipment in industrial gasification.In this work,an RSC with radiation screens is established and the impact of gaseous radiative property models,gas ... Radiant syngas cooler(RSC)is widely used as a waste heat recovery equipment in industrial gasification.In this work,an RSC with radiation screens is established and the impact of gaseous radiative property models,gas components,and ash particles on heat transfer is investigated by the numerical simulation method.Considering the syngas components and the pressure environment of the RSC,a modified weighted-sum-of-gray-gases model was developed.The modified model shows high accuracy in validation.In computational fluid dynamics simulation,the calculated steam production is only 0.63%in error with the industrial data.Compared with Smith's model,the temperature decay along the axial direction calculated by the modified model is faster.Syngas components are of great significance to heat recovery capacity,especially when the absorbing gas fraction is less than 10%.After considering the influence of particles,the outlet temperature and the proportion of radiative heat transfer are less affected,but the difference in steam output reaches 2.7 t·h^(-1).The particle deposition on the wall greatly reduces the heat recovery performance of an RSC. 展开更多
关键词 Radiant syngas cooler Weighted-sum-of-gray-gases model Numerical simulation Particle radiation
下载PDF
Analysis of the Erosion-Corrosion Mechanism of the Air Cooler in a Hydrocracking Unit:A Numerical and Experimental Study
4
作者 Su Guoqing Li Yan +1 位作者 Guo Hongli Zhang Jianwen 《China Petroleum Processing & Petrochemical Technology》 SCIE CAS CSCD 2024年第1期126-138,共13页
Corrosion leakages often occur in the air cooler of a hydrocracking unit,with the failure sites mainly located in the entrance area of the tubes.An analysis of the macroscopic morphology and corrosion products confirm... Corrosion leakages often occur in the air cooler of a hydrocracking unit,with the failure sites mainly located in the entrance area of the tubes.An analysis of the macroscopic morphology and corrosion products confirmed that the damage was caused by erosion-corrosion(E-C).Numerical and experimental methods were applied to investigate the E-C mechanism in the air cooler.Computational fluid dynamics(CFD)was used to calculate the hydrodynamic parameters of the air cooler.The results showed that there was a biased flow in the air cooler,which led to a significant increase in velocity,turbulent kinetic energy and wall shear within 0.2 m of the tube entrance.A visualization experiment was then performed to determine the principles of migration and transformation of multiphase flow in the air cooler tubes.Various flow patterns(pure droplet flow,mist flow,and annular flow)and their evolutionary processes were clearly depicted experimentally.The initiation mechanism and processes leading to the development of E-C in the air cooler were also determined.This study provided a comprehensive explanation for the E-C failures that occur in air coolers during operation. 展开更多
关键词 air cooler hydrocracking unit EROSION-CORROSION SIMULATION visualization experiment multiphase flow
下载PDF
Design calculation of porous ceramics tube type dew point indirect evaporative cooler 被引量:1
5
作者 毛秀明 黄翔 文力 《Journal of Southeast University(English Edition)》 EI CAS 2010年第2期205-208,共4页
To improve the wall surface hydrophilicity of a tube type indirect evaporative cooler,a new method adopting porous ceramics is proposed.This method realizes the combination of porous ceramics and the evaporative cooli... To improve the wall surface hydrophilicity of a tube type indirect evaporative cooler,a new method adopting porous ceramics is proposed.This method realizes the combination of porous ceramics and the evaporative cooling technique.The design calculation of the porous ceramics tube type dew point indirect evaporative cooler are carried out from such aspects as the volumes and status parameters of the primary and secondary air,the cooler structure,the heat transfer of the solid porous ceramic tubes and the resistance of the cooler.The calculation results show that the design is reasonable.Finally,based on the design calculation,the porous ceramics tube type dew point indirect evaporative cooler is successfully manufactured. 展开更多
关键词 tube type indirect evaporative cooler dew point porous ceramics design calculation
下载PDF
Influence of regenerator flow resistance on stability of pulse tube cooler 被引量:1
6
作者 蒋彦龙 陈国邦 《Journal of Southeast University(English Edition)》 EI CAS 2005年第3期277-281,共5页
Based on the fluid network theory,the possibility of utilizing regenerator flow resistance to suppress the direct current (DC) flow induced by the introduction of a double-inlet in a pulse tube cooler is investigate... Based on the fluid network theory,the possibility of utilizing regenerator flow resistance to suppress the direct current (DC) flow induced by the introduction of a double-inlet in a pulse tube cooler is investigated theoretically. The calculation results show that increasing regenerator flow resistance can lead to a smaller extent of DC flow.Therefore,a better stability performance of the cooler can be realized.On this basis,the stability characteristics of the cooler with various regenerator matrix arrangements are studied by experiments.By replacing 30% space of 247 screens of stainless steel mesh at the cold part of the regenerator by lead balls of 0.25 mm diameter,a long-time stable temperature output at 80 K region is achieved. This achievement provides a new way to obtain stable performance for pulse tube coolers at high temperature and is helpful for its application. 展开更多
关键词 pulse tube cooler flow resistance STABILITY
下载PDF
首钢股份360 m^(2)烧结环冷机节能改造及余热烟气超温分析
7
作者 张灵君 《科学技术创新》 2025年第4期225-228,共4页
钢铁企业烧结工序中,环冷机冷却烧结矿的同时,会产生大量高品位余热余能,其中约30%烧结工序总能耗在冷却系统散失,利用好这部分能耗是烧结工序节能降耗的重点。本文通过改造首钢股份有限公司炼铁作业部二烧结415 m^(2)环冷机减少环冷机... 钢铁企业烧结工序中,环冷机冷却烧结矿的同时,会产生大量高品位余热余能,其中约30%烧结工序总能耗在冷却系统散失,利用好这部分能耗是烧结工序节能降耗的重点。本文通过改造首钢股份有限公司炼铁作业部二烧结415 m^(2)环冷机减少环冷机的漏风,提升烟气温度,增加锅炉产汽量,并针对余热烟气超温等问题进行了研究分析,采取了相应措施,取得了较好的效果。 展开更多
关键词 环冷机 余热 超温 改造
下载PDF
Effect of sinter layer porosity distribution on flow and temperature fields in a sinter cooler 被引量:28
8
作者 Jik-chang Leong Kai-wun Jin +2 位作者 Jia-shyan Shiau Tzer-ming Jeng Chang-hsien Tai 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2009年第3期265-272,共8页
When sinters are filled into the sinter cooler from the sintering machine, it is commonly seen that, due to segregation effects, sinters of larger size usually accumulate closer to the inner wall of the sinter cooler,... When sinters are filled into the sinter cooler from the sintering machine, it is commonly seen that, due to segregation effects, sinters of larger size usually accumulate closer to the inner wall of the sinter cooler, whereas those of smaller size are to the outer wall. This nonuniform distribution of sinters has led to uneven cooling effect throughout the cooler. This causes the sinters leaving the cooler at a large temperature difference. This undesired temperature difference leads to the deformation and even the destruction of the conveyors. The computational fluid dynamics (CFD) technique was used in the present work to investigate the heat and fluid flow phenomena within the sinter cooler corresponding to the different distribution of sinter layer porosity, which was highly dependent on the arrangement and orientation of sinters within the sinter cooler. It is confirmed that a high mass flow rate within the sinter layer causes a low temperature region and vice versa. The flow fields for vertically reducing porosity distribution and random distribution are almost identical indicating the relative insignificance of convective heat transfer mechanism. 展开更多
关键词 steel plant sinter cooler SINTER POROSITY heat transfer packed bed
下载PDF
Designing for Long Campaign Life Blast Furnace (1)──The Mathematical Model of Temperature Field for Blast Furnace Lining and Cooling Apparatus and New Concept of Long Campaignship Blast Furnace Cooler Design 被引量:5
9
作者 Susen Cheng Qingguo Xue +2 位作者 Weiguo Yang kaolin Wu Tianjun Yang(Metallurgy School, University of Science and Technology Beijing, Beijing 100083, China)(Ironmaking Department, Bejing Central Engineering and Incoporation of Iron and Steel Industry, Bejing, 1000 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 1999年第3期178-182,共5页
The physical and mathematical model of temperature field for blast furnace stave coolers was established. The computation results show that the heat resistance of 2-6 mm water scale within the cooling pipe is about 7... The physical and mathematical model of temperature field for blast furnace stave coolers was established. The computation results show that the heat resistance of 2-6 mm water scale within the cooling pipe is about 7%-20% of the total heat resistance of cooling stave body, as for drilling duct type, the heat resistance of 2-6 mm water scale is about 88%-98% of the total heat resistance. Using drilling duct or full cast pipe can eliminate gas clearance and coating layer between pipes and cast iron body and reduce the heat resistance of the cooler sharply and improve the coefficient of heat transfer to a great extent. The water velocity within coolers can be kept at the 1evel of 0.5- 1 .5 m/s, the higher water velocity can not decrease the hot surface temperature, but can increase energy consumption for cooling water. 展开更多
关键词 blast furnace cooler mathematical model heat resistance water velocity
下载PDF
Ammonium Salt Deposition Characteristics in an Air Cooler System Based on the Coupling of Fluid Flow and Heat Transfer Simulation 被引量:5
10
作者 Jin Haozhe Zhou Junfeng +2 位作者 Liu Wenwen Liu Xiaofei Ou Guofu 《China Petroleum Processing & Petrochemical Technology》 SCIE CAS 2019年第4期94-102,共9页
The ammonium salt corrosion is a typical failure mode for the hydrogenation reaction effluent air cooler(REAC) system. In order to investigate the corrosion characteristics in the REAC system, numerical simulations we... The ammonium salt corrosion is a typical failure mode for the hydrogenation reaction effluent air cooler(REAC) system. In order to investigate the corrosion characteristics in the REAC system, numerical simulations were performed by using the mixture model, the heating transfer model, and the particles tracking model. The results show that the differences between the temperature and the velocity at each cross section of the first-row and second-row tubes are small. The inertia of the particles plays an important role in the particle’s deposition, and the smaller particles distribute more uniformly in the air cooler. However, for larger particles, they prefer falling from the inner side of the vertical elbow, and preferentially depositing at the inlet header and pipes before saturation. In the heat exchanger tubes, the particle deposition number is larger in the second-row tubes than that in the first-row tubes, and the high-risk tubes mainly concentrate on the middle and right side of the air cooler. The kinetic parameters of the particles are in accordance with the blocking-prone position in many real operating conditions. 展开更多
关键词 hydrogenation air cooler multiphase flow ammonium salt corrosion particles drifting
下载PDF
Experimental and Numerical Investigation on Erosion Corrosion of the Air Cooler Tube Bundle in a Residue Hydrotreating Unit 被引量:3
11
作者 Jin Haozhe Yu Chenyang +4 位作者 Gu Youjie Qian Guangwei Liu Xiaofei Ou Guofu Jia Yongna 《China Petroleum Processing & Petrochemical Technology》 SCIE CAS 2022年第4期151-162,共12页
Corrosion leakage occurred in the 14th tube bundle in the first row of a residual oil hydrotreating air cooler after operating for two years.The failure location was 0.5 m from the outlet header box.In this paper,the ... Corrosion leakage occurred in the 14th tube bundle in the first row of a residual oil hydrotreating air cooler after operating for two years.The failure location was 0.5 m from the outlet header box.In this paper,the erosion corrosion of the air cooler tube bundle was investigated by experimental and numerical methods.Visual inspection,scanning electron microscopy(SEM),and X-ray diffraction(XRD)experiments were performed,and the failure morphology and material composition confirmed that the damage was caused by erosion corrosion.The shear stress transport k–ωturbulence model(SST-k–ω)was then used to investigate the flow and erosion corrosion characteristics,combined with mass transfer,corrosion rate,and ionization equilibrium models.The numerical simulation results revealed that the water phase volume fraction increased with flow and heat transfer in the fluid,which increased the mass flow rate and concentration of hydrogen sulfide.The mass transfer coefficient and corrosion rate were proposed as important parameters to characterize erosion corrosion.Moreover,the local concentration of wall shear stress was found to increase the risk of erosion corrosion.The predicted high-risk area was consistent with the actual failure area,which verified that this failure incident was attributable to erosion corrosion by the water phase. 展开更多
关键词 erosion corrosion air cooler tube bundle(ACTB) RESIDUE THINNING hydrogen sulfide
下载PDF
Numerical Simulation and Optimization of Perforated Tube Trolley in Circular Cooler 被引量:1
12
作者 Bin Wu Kunrong Huang +1 位作者 Defan Qing Maokui Zhu 《World Journal of Engineering and Technology》 2017年第4期684-695,共12页
Three symmetrically perforated tubes were arranged in the circular cooler trolley as auxiliary cooling inlet to improve the cooling performance of the sintered body during the production process. Fluent 15.0 has been ... Three symmetrically perforated tubes were arranged in the circular cooler trolley as auxiliary cooling inlet to improve the cooling performance of the sintered body during the production process. Fluent 15.0 has been used to simulate the process;the study shows that the perforated tube structure trolley has changed the temperature field within the sintering area, thereby improving the sintering area of the cooling effect and uniformity, also greatly reducing the cooling time. Compared with the traditional trolley, the best structure of the porous tube trolley has reduced 41% cooling time and increased 50% waste heat recovery. 展开更多
关键词 CIRCULAR cooler Perforated TUBE Structural Optimization COOLING Performance ORTHOGONAL Test
下载PDF
Numerical simulation and optimization design of the EGR cooler in vehicle 被引量:3
13
作者 Yu-qi HUANG Xiao-li YU Guo-dong LU 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2008年第9期1270-1276,共7页
The EGR (exhaust gas recirculation) technique can greatly reduce the NOx emission of diesel engines, especially when an EGR cooler is employed. Numerical simulations are applied to study the flow field and temperature... The EGR (exhaust gas recirculation) technique can greatly reduce the NOx emission of diesel engines, especially when an EGR cooler is employed. Numerical simulations are applied to study the flow field and temperature distributions inside the EGR cooler. Three different models of EGR cooler are investigated, among which model A is a traditional one, and models B and C are improved by adding a helical baffle in the cooling area. In models B and C the entry directions of cooling water are different, which mostly influences the flow resistance. The results show that the improved structures not only lengthen the flow path of the cooling water, but also enhance the heat exchange rate between the cool and hot media. In conclusion we suggest that the improved structures are more powerful than the traditional one. 展开更多
关键词 Exhaust gas recirculation (EGR) cooler Computational fluid dynamics (CFD) Shell-and-tube heat exchanger Helical baffle
下载PDF
Functional Link Neural Network for Predicting Crystallization Temperature of Ammonium Chloride in Air Cooler System 被引量:3
14
作者 Jin Haozhe Gu Yong +3 位作者 Ren Jia Wu Xiangyao Quan Jianxun Xu Linfengyi 《China Petroleum Processing & Petrochemical Technology》 SCIE CAS 2020年第2期86-92,共7页
The air cooler is an important equipment in the petroleum refining industry.Ammonium chloride(NH4 Cl)deposition-induced corrosion is one of its main failure forms.In this study,the ammonium salt crystallization temper... The air cooler is an important equipment in the petroleum refining industry.Ammonium chloride(NH4 Cl)deposition-induced corrosion is one of its main failure forms.In this study,the ammonium salt crystallization temperature is chosen as the key decision variable of NH4 Cl deposition-induced corrosion through in-depth mechanism research and experimental analysis.The functional link neural network(FLNN)is adopted as the basic algorithm for modeling because of its advantages in dealing with non-linear problems and its fast-computational ability.A hybrid FLNN attached to a small norm is built to improve the generalization performance of the model.Then,the trained model is used to predict the NH4 Cl salt crystallization temperature in the air cooler of a sour water stripper plant.Experimental results show the proposed improved FLNN algorithm can achieve better generalization performance than the PLS,the back propagation neural network,and the conventional FLNN models. 展开更多
关键词 air cooler NH4Cl salt crystallization temperature DATA-DRIVEN functional link neural network particle swarm optimization
下载PDF
Performance Investigation of Capillary Tubes for Machine Tool Coolers Retrofitted with HFC-407C Refrigerant
15
作者 WANG Fujen CHANG Tongbou +1 位作者 CHIANG Weiming LEE Haochung 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2012年第5期933-939,共7页
The machine tool coolers are the best managers of coolant temperature in avoiding the deviation of spindle centerline for machine tools. However, the machine coolers are facing the compressed schedule to phase out the... The machine tool coolers are the best managers of coolant temperature in avoiding the deviation of spindle centerline for machine tools. However, the machine coolers are facing the compressed schedule to phase out the HCFC (hydro-chloro-floro-carbon) refrigerant and little attention has been paid to comparative study on sizing capillary tube for retrofitted HFC (hydro-floro-carbon) refrigerant. In this paper, the adiabatic flow in capillary tube is analyzed and modeled for retrofitting of HFC-407C refrigerant in a machine tool cooler system. A computer code including determining the length of sub-cooled flow region and the two phase region of capillary tube is developed. Comparative study of HCFC-22 and HFC-407C in a capillary tube is derived and conducted to simplify the traditional trial-and-error method of predicting the length of capillary tubes. Besides, experimental investigation is carried out by field tests to verify the simulation model and cooling performance of the machine tool cooler system. The results from the experiments reveal that the numerical model provides an effective approach to determine the performance data of capillary tube specific for retrofitting a HFC-407C machine tool cooler. The developed machine tool cooler system is not only directly compatible with new HFC-407C refrigerant, but can also perform a cost-effective temperature control specific for industrial machines. 展开更多
关键词 machine tool cooler capillary tube REFRIGERANT retrofitting
下载PDF
Reliability Investigation of Semiconductor Coolers
16
作者 刘振茂 王喜莲 +1 位作者 刘晓为 权五云 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 1998年第3期10-13,共4页
The tests on the thermoelectric shock of semiconductor coolers show that the life of semiconductor coolers follows the Weibull distribution. After the early failed devices are removed, the failure rule of the devices ... The tests on the thermoelectric shock of semiconductor coolers show that the life of semiconductor coolers follows the Weibull distribution. After the early failed devices are removed, the failure rule of the devices can be described as an exponential distribution. The main failure mode is tile crack between electric couple material and welding pad. The failure mechanism is the orientated incline and easy splitting of the thermoelectric materials and the stress of substrate deformation due to the temperature difference between the two sides of the cooler. The reliability of the devices can be improved by using multi-layer metalization in electric couple welding. 展开更多
关键词 SEMICONDUCTOR cooler RELIABILITY TEST LIFE distribution.
下载PDF
Experimental Investigation of Capacity Control Scheme on System Performance for a Machine Tool Cooler
17
作者 WANG Fujen CHANG Tongbou +1 位作者 KAO Jianwei LEE Haochung 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2011年第3期333-339,共7页
Highly accurate manufacture in machining industry can only be obtained with precise temperature control of the coolant (oil or water).Machine tool with more accurate,stable and advanced the precision of the working ... Highly accurate manufacture in machining industry can only be obtained with precise temperature control of the coolant (oil or water).Machine tool with more accurate,stable and advanced the precision of the working component cannot be developed without appropriate cooling.However,the machine tool coolers are facing the control hunting of cooling temperature and the dramatic variation of heat load in high-accuracy machining.The main objective of this study is to evaluate the influence of the hot-gas by-pass scheme and suction regulation for capacity control of a machine tool cooler system.In this study,experimental investigation on both hot-gas by-pass scheme and suction valve regulation for capacity control has been proposed.Effects of using capillary tube and thermostatic expansion valve along with different capacity control scheme have been investigated extensively in an environmental testing room.Cooling performance and power consumption of the cooler system have been measured and analyzed as well by comparing with different opening percentage of throttling valve under specific coolant temperature.The experimental results reveal that the power consumption will reduce slightly by capacity control using the hot-gas by-pass scheme but the coefficient of performance (COP) of the overall system will decrease.Lower coolant temperature will result in higher compressor power consumption as well.While conducting suction valve regulating for capacity control,energy-saving at 10%-12% can be obtained by using thermostatic expansion valve under different evaporator load.It also reveals that suction valve regulation along with adequate choice of thermostatic expansion valve can provide alternative choice for steady capacity control and substantial energy-saving.The proposed cooler systems with different capacity control schemes are not only more cost-effective than inverter driven system,but also can perform energy-saving and precise temperature control specific for high-accuracy machine tool cooling. 展开更多
关键词 machine tool cooler hot-gas by-pas suction regulation capacity control
下载PDF
MATERIALS FOR RETENTION OF LIQUID CRYOGENS CONTAINED IN SPACE QUALIFIED COOLER
18
作者 YX. Qi J.K Xeand B.P. Huang (Shanghai Institute of Technical Physics, Chinese Academy of Sciences, Shanghai 200083, China) 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 1997年第3期224-227,共4页
A new kind of material used in liquid cryogen cooler has been found and investigated in our group It is anticipated that the materials can be applied in the conditions of launching, rotation in any orientation and wei... A new kind of material used in liquid cryogen cooler has been found and investigated in our group It is anticipated that the materials can be applied in the conditions of launching, rotation in any orientation and weightlessness. The mechanism on which the material relies is similar to 'sponge' trapping the liquid cryogens within its micro-pores with surface tension. Preliminary tests have been performed on wicking. Also,we apply the materials to the cryogenic optical cooler whjch needs to be maintained within the temperuture range of 80-100 K. The results are satisfactory. 展开更多
关键词 liquid cryogen cooler surface tension sponge material
下载PDF
A Simplified Model for Analysis of Heat and Mass Transfer in an Indirect Evaporative Cooler 被引量:1
19
作者 A. Fouda Z. Melikyan 《Journal of Energy and Power Engineering》 2010年第9期1-6,共6页
A simplified model for analysis of heat and mass transfer between air stream and flowing down water film in counter-flow plate heat exchanger which serves as an indirect evaporative cooler is theoretically analyzed in... A simplified model for analysis of heat and mass transfer between air stream and flowing down water film in counter-flow plate heat exchanger which serves as an indirect evaporative cooler is theoretically analyzed in this paper. Indirect evaporative cooler is used for sensible cooling of air which then is used for air conditioning purposes. Mathematical model was developed allowing determining heat transfer surface, outlet air temperature and specific humidity of the air being cooled. To make the model simpler some simplifications have been incorporated. The model has high level of correctness and can be used to calculate and design different types of evaporative heat exchangers. Analysis of results of calculations by the help of the developed model prove that the surface of heat exchanger depends on the thickness of water film layer by the regularity of direct proportionality. Moreover, increasing of the water film thickness brings to the decreasing of the efficiency of evaporative type heat exchanger. The model can be used for correct calculation and design of an evaporative cooling air conditioning systems. 展开更多
关键词 Heat exchanger counter flow air conditioning indirect evaporative cooler
下载PDF
Experimental Study on the Radiative Properties of Fly Ash in the Radiant Syngas Cooler of Gasifier
20
作者 Zhifei Fu Qian Wang Jiansheng Zhang 《Journal of Power and Energy Engineering》 2018年第9期9-20,共12页
Radiant syngas cooler (RSC) is the key heat recovery equipment in coal gasification system. The syngas from gasifier carries large amount of slags in which the mass fraction of fly ash less than 100 μm is about 20%. ... Radiant syngas cooler (RSC) is the key heat recovery equipment in coal gasification system. The syngas from gasifier carries large amount of slags in which the mass fraction of fly ash less than 100 μm is about 20%. Studying the optical properties of fly ash has high significance for the optimization of heat transfer calculation in RSC. A new experimental method was proposed to inversely calculate the radiative parameters of particles—“KBr transmittance-reflectance method”. By measuring the “directional-hemispherical” reflectance and transmittance of fly ash particles by FTIR under the wavelength range of 0.55 - 1.65 μm, using the four-flux model to solve the radiative transfer equation and combing with Mie theory, the absorption and scattering efficiency of 22.7 μm fly ash and optical constant (also known as complex refractive index, m = n + ik) of fly ash were inversely calculated. The results indicated that for fly ash with large size parameter, there was no obvious change of the absorption and scattering efficiency when the mass fraction of Fe2O3 was between 5.65% and 16.53%, which was well explained by Mie theory;The obtained optical constant was close to the results of KBr trans-mittance method. 展开更多
关键词 Radiant SYNGAS cooler FLY Ash RADIATIVE Properties Absorption EFFICIENCY Scattering EFFICIENCY Optical Constant
下载PDF
上一页 1 2 249 下一页 到第
使用帮助 返回顶部