A method was proposed to analyze the influences of the non-ideal spectroscopic performance of optical components and orientation errors of a laser tracing measurement optical system on the tracing measurement performa...A method was proposed to analyze the influences of the non-ideal spectroscopic performance of optical components and orientation errors of a laser tracing measurement optical system on the tracing measurement performance.A comprehensive model of the interference fringe contrast based on the laser tracing system s measurement principle was established in this study.Simulation results based on ZEMAX verified the model.According to the simulation results,the placement angle of the analyzer had a direct influence on the interference fringe contrast.When the angle of the polarized light to the analyzer’s transmission axis increased from 65°to 85°,each contrast of the four-way interference fringes decreased from 0.9996 to 0.3528,the interference fringe contrast is decreased by 65%.Under the split ratio of beam splitters in the interference part(BS 1)of 5∶5,when the splitting ratio of BS 2 changed from 2∶8 to 8∶2,the fringe contrast of the interference signals received by the photodetectors increased,but the injection light intensity onto the PSD reflected by BS 2 decreased.The significant influence of the tracing performance was verified by the experiments.When splitting ratio of BS 2 increased,the contrast of the interference fringes increased.Due to the weakening of the incident light intensity of the PSD caused by the change of BS 2 splitting ratio,the response time of the tracing system is increased by 23.7 ms.As a result,the tracing performance of the laser tracing measurement optical system was degraded.An important theoretical basis was provided to evaluate and improve the accuracy and reliability of laser tracing measurement systems.展开更多
Aiming at the problem that it is difficult to measure the electromagnetic radiation produced by the equipment at present,this paper presents a method for measuring the noise of electromagnetic interference(EMI)based o...Aiming at the problem that it is difficult to measure the electromagnetic radiation produced by the equipment at present,this paper presents a method for measuring the noise of electromagnetic interference(EMI)based on wavelet analysis.The technique uses time frequency localization features of the wavelet transform,based on threshold function filtering method to filter the test signal,which makes it possible in open space or noisy environment for measurement of electromagnetic interference of equipment.Simulation and experimental results show that the technique is able to eliminate or attenuate the noise in the frequency band of 30Hz^1000MHz.展开更多
The aim of this paper was to test for measurement bias, due to cognitive interference on cognitive ability tests, using a structural equation modeling technique. The sample consisted of 231 undergraduate students who ...The aim of this paper was to test for measurement bias, due to cognitive interference on cognitive ability tests, using a structural equation modeling technique. The sample consisted of 231 undergraduate students who were examined with three tests addressed to numerical ability, space visualization and inductive ability, respectively. They were also asked to respond to the Cognitive Interference Questionnaire tapping task-oriented worries while working on the aforementioned tests. In comparing two nested models, one hypothesizing measurement bias due to cognitive interference and one not, results show that the test tapping inductive ability displays measurement bias due to cognitive interference.展开更多
To reduce the environmental pollution and meet the needs for wearable electronic devices, new requirements for electromagnetic interference(EMI) shielding materials include flexibility, biodegradability, and biocompat...To reduce the environmental pollution and meet the needs for wearable electronic devices, new requirements for electromagnetic interference(EMI) shielding materials include flexibility, biodegradability, and biocompatibility. Herein, we reported a polypyrrole-coated zein/epoxy(PPy/ZE) ultrafine fiber mat which was inherently biodegradable and skin-friendly. In addition, it could maintain its ultrafine fibrous structure after coating, which could provide the mat with mechanical compliance, high porosity, and a large specific area for high EMI shielding. With the assistance of the epoxide cross-linking, the breaking stresses of the PPy/ZE fiber mats could achieve 3.3 MPa and 1.4 MPa and the strains were 40.1% and 83.0% in dry and wet states, respectively, which met the needs of various wearable electronic devices. Along with the extension in the PPy treatment duration, more PPy was loaded on the fiber surfaces, which formed more integrated and conductive paths to generate increasing conductivities up to 401.76 S·m^(-1). Moreover, the EMI shielding performance was raised to 26.84 dB. The biobased mats provide a green and efficient choice for EMI shielding materials, which may be a promising strategy to address EMI problems in multiple fields.展开更多
To meet the demands for flexible electromagnetic interference(EMI)shielding materials,a type of conductive fabric is prepared by generating three-dimensional(3D)porous laser-induced graphene(LIG)in situ on the surface...To meet the demands for flexible electromagnetic interference(EMI)shielding materials,a type of conductive fabric is prepared by generating three-dimensional(3D)porous laser-induced graphene(LIG)in situ on the surface of the aramid fabric(AF)and then electroless plating copper.After LIG treatment,the porous AF demonstrates admirable conductivity due to the generation of graphene.The superior surface resistance of the conductive fabric can reach 1.57Ω/sq after copper deposition,and the average EMI shielding effectiveness(SE)can reach 34.3 dB in a frequency range of 8.2 to 12.4 GHz,with the EMW absorption accounting for about 80%.The proposed technology provides a new idea for preparation of flexible EMI shielding materials.展开更多
Laser self-mixing interference(SMI) wave plate measurement method is a burgeoning technique for its simplicity and efficiency. But for the non-coated sample, the reflected light from the surface can seriously affect...Laser self-mixing interference(SMI) wave plate measurement method is a burgeoning technique for its simplicity and efficiency. But for the non-coated sample, the reflected light from the surface can seriously affect the measurement results.To analyze the reason theoretically, a self-consistent model for laser operation with a sub-external and an external cavity is established, and the sub-external cavity formed by the sample and a cavity mirror is proved to be the main error source.A synchronous tuning method is proposed to eliminate the sub-external cavity effect. Experiments are carried out on the synchronously tuning double external cavities self-mixing interference system, and the error of the system is in the range of -0.435°~0.387° compared with the ellipsometer. The research plays an important role in improving the performance and enlarging the application range of the laser self-mixing interference system.展开更多
基金Sponsored by the National Natural Science Foundation of China(Grant No.52175491).
文摘A method was proposed to analyze the influences of the non-ideal spectroscopic performance of optical components and orientation errors of a laser tracing measurement optical system on the tracing measurement performance.A comprehensive model of the interference fringe contrast based on the laser tracing system s measurement principle was established in this study.Simulation results based on ZEMAX verified the model.According to the simulation results,the placement angle of the analyzer had a direct influence on the interference fringe contrast.When the angle of the polarized light to the analyzer’s transmission axis increased from 65°to 85°,each contrast of the four-way interference fringes decreased from 0.9996 to 0.3528,the interference fringe contrast is decreased by 65%.Under the split ratio of beam splitters in the interference part(BS 1)of 5∶5,when the splitting ratio of BS 2 changed from 2∶8 to 8∶2,the fringe contrast of the interference signals received by the photodetectors increased,but the injection light intensity onto the PSD reflected by BS 2 decreased.The significant influence of the tracing performance was verified by the experiments.When splitting ratio of BS 2 increased,the contrast of the interference fringes increased.Due to the weakening of the incident light intensity of the PSD caused by the change of BS 2 splitting ratio,the response time of the tracing system is increased by 23.7 ms.As a result,the tracing performance of the laser tracing measurement optical system was degraded.An important theoretical basis was provided to evaluate and improve the accuracy and reliability of laser tracing measurement systems.
文摘Aiming at the problem that it is difficult to measure the electromagnetic radiation produced by the equipment at present,this paper presents a method for measuring the noise of electromagnetic interference(EMI)based on wavelet analysis.The technique uses time frequency localization features of the wavelet transform,based on threshold function filtering method to filter the test signal,which makes it possible in open space or noisy environment for measurement of electromagnetic interference of equipment.Simulation and experimental results show that the technique is able to eliminate or attenuate the noise in the frequency band of 30Hz^1000MHz.
文摘The aim of this paper was to test for measurement bias, due to cognitive interference on cognitive ability tests, using a structural equation modeling technique. The sample consisted of 231 undergraduate students who were examined with three tests addressed to numerical ability, space visualization and inductive ability, respectively. They were also asked to respond to the Cognitive Interference Questionnaire tapping task-oriented worries while working on the aforementioned tests. In comparing two nested models, one hypothesizing measurement bias due to cognitive interference and one not, results show that the test tapping inductive ability displays measurement bias due to cognitive interference.
基金Fundamental Research Funds for the Central Universities,China(No. 2232022D-13)Fundamental Research Funds of Shanghai Collaborative Innovation Center of High Performance Fibers and Composites (Province-M inistry Joint),China(No. X12812101/015)。
文摘To reduce the environmental pollution and meet the needs for wearable electronic devices, new requirements for electromagnetic interference(EMI) shielding materials include flexibility, biodegradability, and biocompatibility. Herein, we reported a polypyrrole-coated zein/epoxy(PPy/ZE) ultrafine fiber mat which was inherently biodegradable and skin-friendly. In addition, it could maintain its ultrafine fibrous structure after coating, which could provide the mat with mechanical compliance, high porosity, and a large specific area for high EMI shielding. With the assistance of the epoxide cross-linking, the breaking stresses of the PPy/ZE fiber mats could achieve 3.3 MPa and 1.4 MPa and the strains were 40.1% and 83.0% in dry and wet states, respectively, which met the needs of various wearable electronic devices. Along with the extension in the PPy treatment duration, more PPy was loaded on the fiber surfaces, which formed more integrated and conductive paths to generate increasing conductivities up to 401.76 S·m^(-1). Moreover, the EMI shielding performance was raised to 26.84 dB. The biobased mats provide a green and efficient choice for EMI shielding materials, which may be a promising strategy to address EMI problems in multiple fields.
基金Shanghai Sailing Program,Shanghai,China(No.22YF1400500)Fundamental Research Funds for the Central Universities,China(Nos.2232022D-11 and 22D128102/007)Shanghai Natural Science Foundation of Shanghai Municipal Science and Technology Commission,Shanghai,China(No.20ZR1401600)。
文摘To meet the demands for flexible electromagnetic interference(EMI)shielding materials,a type of conductive fabric is prepared by generating three-dimensional(3D)porous laser-induced graphene(LIG)in situ on the surface of the aramid fabric(AF)and then electroless plating copper.After LIG treatment,the porous AF demonstrates admirable conductivity due to the generation of graphene.The superior surface resistance of the conductive fabric can reach 1.57Ω/sq after copper deposition,and the average EMI shielding effectiveness(SE)can reach 34.3 dB in a frequency range of 8.2 to 12.4 GHz,with the EMW absorption accounting for about 80%.The proposed technology provides a new idea for preparation of flexible EMI shielding materials.
文摘Laser self-mixing interference(SMI) wave plate measurement method is a burgeoning technique for its simplicity and efficiency. But for the non-coated sample, the reflected light from the surface can seriously affect the measurement results.To analyze the reason theoretically, a self-consistent model for laser operation with a sub-external and an external cavity is established, and the sub-external cavity formed by the sample and a cavity mirror is proved to be the main error source.A synchronous tuning method is proposed to eliminate the sub-external cavity effect. Experiments are carried out on the synchronously tuning double external cavities self-mixing interference system, and the error of the system is in the range of -0.435°~0.387° compared with the ellipsometer. The research plays an important role in improving the performance and enlarging the application range of the laser self-mixing interference system.