期刊文献+
共找到127篇文章
< 1 2 7 >
每页显示 20 50 100
Investigation and analysis on indoor air quality of large commercial office building in summer 被引量:1
1
作者 魏小清 李念平 +2 位作者 周慧 肖书博 胡丽君 《Journal of Southeast University(English Edition)》 EI CAS 2010年第2期243-245,共3页
To study the indoor air qualities(IAQ)of large commercial office buildings in Hunan province of China and the corresponding improvement methods,the IAQ of a large commercial office building in Changsha in July,2008,... To study the indoor air qualities(IAQ)of large commercial office buildings in Hunan province of China and the corresponding improvement methods,the IAQ of a large commercial office building in Changsha in July,2008,is investigated.A questionnaire survey and field tests are used to collect data.According to the data of twelve rooms in this building,objective evaluation and the subjective evaluation of the IAQ are obtained.Almost all of the environmental parameters in these rooms basically meet the standards of the objective evaluation.But the average concentration of carbon dioxide in most rooms cannot reach the value of the cleanliness standards,1 255 mg/m^3.The average acceptability of the IAQ in these rooms is 71%,which is lower than the value of the ASHRAE 55—1992 standards,80%.The proper increase in the wind speed and the indoor fresh air supply can greatly improve the objective evaluation and the subjective evaluation of the IAQ. 展开更多
关键词 large commercial office building indoor air qualityiaq objective evaluation subjective evaluation
下载PDF
Generation of a Controlled Polluted Atmosphere for Vehicles’ Cabins Air Quality Characterization
2
作者 N.M.Hafs A.Mehel +2 位作者 G.Fokoua P.Chevrier H.Er-Rbib 《Journal of Mechanics Engineering and Automation》 2023年第2期17-31,共15页
Air pollution induces significant health risks to individuals exposed to high levels of pollutants concentration. For ground vehicles, pollutants infiltrate the car cabin through the ventilation system, leading to pot... Air pollution induces significant health risks to individuals exposed to high levels of pollutants concentration. For ground vehicles, pollutants infiltrate the car cabin through the ventilation system, leading to potential health issues. To address this problem, a project was undertaken to develop a protocol for characterizing in-cabin air quality. The study involved a closed chamber (the bubble) where its internal multiphase flow has been optimized to create controlled polluted atmospheres. Experiments were conducted to optimize the positioning of the stirring fan and particle generation source, ensuring a homogeneous distribution of fine and ultrafine particles. This study demonstrated the feasibility of implementing a platform dedicated to characterizing the vehicles’ in-cabin air quality under controlled conditions. It allows a better understanding of the dynamics of particle infiltration and the establishment of an optimized protocol for simultaneous measurements of indoor and outdoor concentrations. 展开更多
关键词 air pollution chamber vehicle interior air quality car cabin particle infiltration
下载PDF
Design of Multi-gas Monitoring Device for Indoor Air Quality
3
作者 Serri Abdul Razzaq Saleh Huda Jamal Jumaah +1 位作者 Zainab Ali Khalaf Sarah Jamal Jumaah 《Journal of Electronic & Information Systems》 2023年第1期1-9,共9页
Besides the need for low-cost instruments for air pollution measurement and detection,nowadays there are many concerns about air pollution due to the fast changes and used technologies.This research was applied using ... Besides the need for low-cost instruments for air pollution measurement and detection,nowadays there are many concerns about air pollution due to the fast changes and used technologies.This research was applied using an MQ2 gas detector,and microcontroller/Arduino-Uno.The design steps included bonding and connecting readymade sensors,coding,and finally testing the device.Testing has been conducted in Environment and Pollution Engineering Department laboratories,at the Technical Engineering College of Kirkuk.This study proposed the use of an MQ2 sensor for multi-gas rate detection which can exist indoors.The system uses also a DHT22 sensor for measuring environment temperature and humidity.The sensors are connected to Arduino and LCD to present data on LCD by powering the system with external power.Overall,the testing was conducted,and the device served as a measuring tool for indoor air as an accurate multi-gas rate detector. 展开更多
关键词 MQ2 sensor Arduino Uno Indoor air quality(iaq) Multi gas DHT22
下载PDF
TAKING THE“LEED”IN INDOOR AIR QUALITY:DOES CERTIFICATION RESULT IN HEALTHIER BUILDINGS?
4
作者 Hannah Phillips Rod Handy +3 位作者 Darrah Sleeth Matthew S.Thiese Camie Schaefer James Stubbs 《Journal of Green Building》 2020年第3期55-66,共12页
Indoor Air Quality(IAQ)has been an area of growing concern with the increasing knowledge of health hazards associated with contaminants,particularly in high occupancy buildings where residents may be exposed to high l... Indoor Air Quality(IAQ)has been an area of growing concern with the increasing knowledge of health hazards associated with contaminants,particularly in high occupancy buildings where residents may be exposed to high levels of nuisance dust and other contaminants.Leadership and Energy in Environmental Design(LEED®)certification,which is awarded to buildings that prioritize sustainability and efficient resource use,has been increasingly sought in new construction.As LEED-certified buildings become more commonplace,it is worthwhile to consider whether these new building practices improve IAQ for its occupants.This study compares particulate matter(PM)concentrations in 12 LEED-certified buildings to 12 analogous non-LEED certified buildings on the University of Utah campus.Real-time air sampling was conducted in each building for PM measurements and a Wilcoxon signed rank test was conducted to compare PM levels.A statistically significant difference was found between LEED certification and PM concentrations,with LEED-certified buildings containing,on average,approximately half the PM of their non-LEED counterparts.These findings suggest that LEED certification is worth the financial investment,as it may lead to improved IAQ for residents.However,further research on other contaminants is warranted,including the characterization and comparison of formaldehyde and carbon dioxide levels. 展开更多
关键词 Indoor air quality(iaq) Particulate Matter Concentrations(PM) LEED-Certified Buildings Sick Building Syndrome(SBS)
下载PDF
舒适性空调系统的颗粒污染物控制——改善IAQ的步骤之一 被引量:3
5
作者 韩华 徐文华 范存养 《洁净与空调技术》 2002年第2期13-17,共5页
要改善室内空气品质就必须对室内空气中的污染物质加以控制。针对舒适性空调对空气过滤重视不够的现状,本文主要讨论影响室内空气含尘浓度的各个因素及其影响方式,并对舒适性空调系统的粉尘控制进行探讨。通过理论分析,本文首次提出系... 要改善室内空气品质就必须对室内空气中的污染物质加以控制。针对舒适性空调对空气过滤重视不够的现状,本文主要讨论影响室内空气含尘浓度的各个因素及其影响方式,并对舒适性空调系统的粉尘控制进行探讨。通过理论分析,本文首次提出系统临界过滤效率的概念,并从中得出舒适性空调系统空气过滤器的计算和选择方法供参考。 展开更多
关键词 舒适性空调系统 颗粒污染物 控制 空气品质 临界过滤效率
下载PDF
Recommended Concentration Limits of Typical Indoor Air Contaminants 被引量:1
6
作者 LV Chao1,JIANG Yun-tao2,ZHAO Jia-ning1(1.School of Municipal & Environmental Engineering,Harbin Institute of Technology,Harbin,Heilongjiang 150090,China 2.The Architectural Design and Research Institute,Harbin Institute of Technology,Harbin,Heilongjiang 150090,China) 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期60-65,共6页
From the view of both objective and subjective factors,the indoor air quality(IAQ)evaluation was considered.Carbon dioxide(CO2)and formaldehyde(HCHO)were selected as the typical contaminants of indoor air,and the eval... From the view of both objective and subjective factors,the indoor air quality(IAQ)evaluation was considered.Carbon dioxide(CO2)and formaldehyde(HCHO)were selected as the typical contaminants of indoor air,and the evaluation method of logarithmic index was adopted as the evaluation means of IAQ.Then the recommended limits(RL)of typical contaminants CO2 and HCHO were given through analysis and calculation.The limits of CO2 and HCHO in Indoor Air Quality Standard of China or other existing standards probably correspond to the level of PD=25(%).The result shows that the existing standards fail to meet the requirement of the definition of "acceptable indoor air quality",that is to say,less than 20% of the people express dissatisfaction.When PD=20%,RL of CO2 and HCHO are 728×10-6 and 0.068×10-6 respectively,which are stricter than the limits in the existing standards.The method proposed in this paper is applicable to 13.1%≤PD≤86.7%. 展开更多
关键词 INDOOR air quality(iaq) TYPICAL CONTAMINANTS recommended limits(RL) evaluation method of logarithmic index PERCENTAGE of dissatisfaction(PD)
下载PDF
民用建筑中央空调系统的污染对室内空气品质(IAQ)的影响和控制措施 被引量:3
7
作者 何维 《重庆建筑》 2007年第10期49-51,共3页
文章分析了空调系统的污染对室内IAQ(Indoors Air Quality)的影响程度,指出随着其它污染源被控制,其影响将更加突出;分析了空调系统各部件污染的成因,以及这些污染对IAQ的影响。根据国内外相关文献,结合空调系统设计运行情况和工作实践... 文章分析了空调系统的污染对室内IAQ(Indoors Air Quality)的影响程度,指出随着其它污染源被控制,其影响将更加突出;分析了空调系统各部件污染的成因,以及这些污染对IAQ的影响。根据国内外相关文献,结合空调系统设计运行情况和工作实践,提出防止空调系统污染的措施。 展开更多
关键词 空调系统 室内空气品质 污染控制
下载PDF
北京地区办公建筑室内典型污染物日均浓度与工作时均浓度对比分析 被引量:1
8
作者 厉明 韦古强 +4 位作者 乐辰前 迟洪均 朱基诚 刘聪 李婷 《暖通空调》 2024年第2期22-27,共6页
以办公建筑为代表的具有明确作息规律的建筑中,以污染物浓度24 h平均值作为室内污染物评价指标的合理性尚不清楚。本文以北京某办公建筑为对象,利用为期1个月的室内CO_(2)和PM2.5浓度的实时监测数据,分析了24 h日均浓度和工作时均浓度(0... 以办公建筑为代表的具有明确作息规律的建筑中,以污染物浓度24 h平均值作为室内污染物评价指标的合理性尚不清楚。本文以北京某办公建筑为对象,利用为期1个月的室内CO_(2)和PM2.5浓度的实时监测数据,分析了24 h日均浓度和工作时均浓度(07:00—19:00)的关系。结果表明,对照我国GB/T 18883—2022,室内CO_(2)和PM2.5日均浓度的超标率小于2%,但工作时均浓度的超标率远高于日均浓度(1.25~20倍)。日均浓度与工作时均浓度之间存在较大偏差,PM2.5相对偏差的最大值为0.45,中位值为0.14;CO_(2)相对偏差的最大值为0.34,中位值为0.04。对照我国标准,室内CO_(2)的漏判率为100%,错罚率为0;室内PM2.5的漏判率为62.3%,错罚率为19.7%。错罚率和漏判率与所采用的评价标准密切相关,随着浓度标准的提高,即浓度限值减小,错罚率和漏判率均下降。因此,针对实际办公建筑的空气质量评价,应当同时关注污染物的工作时均浓度而非仅采用24 h日均浓度,并选择合适的评价标准和浓度限值。本文的研究结果为更加准确、有效地评价办公建筑的空气质量评价提供了新思路。 展开更多
关键词 办公建筑 室内空气质量 评价指标 CO_(2)浓度 PM2.5浓度
下载PDF
室内空气质量相关标准与评价方法进展 被引量:14
9
作者 王宗爽 余欢 +1 位作者 白志鹏 朱坦 《城市环境与城市生态》 CAS CSSCI CSCD 北大核心 2003年第4期81-83,共3页
综述了国内外室内空气质量(IAQ)标准、建筑装饰装修材料中有害物质限量标准和室内空气质量评价方法研究的进展情况。根据浓度-呼吸速率-剂量的关系,提出了"参考剂量评价标准"的概念和将来应开展工作的建议。
关键词 室内空气质量 标准 评价 iaq 建筑装修材料 空气耗氧量 AOD 绿色建材 环境污染
下载PDF
应用环境舱研究室内混凝土墙体中氨的释放规律 被引量:27
10
作者 白志鹏 王宗爽 +2 位作者 贾纯荣 张连众 朱坦 《中国环境科学》 EI CAS CSSCI CSCD 北大核心 2003年第2期117-121,共5页
采用环境舱模拟研究了随温度(T)、相对湿度(RH)和空气交换率(AER)变化墙体试块中氨的释放规律,并将现场实验结果与环境舱的模拟实验结果进行对比.研究发现:T和RH一定,随着AER的增大,舱内氨气平衡浓度下降,氨气挥发速率和完全释放时间呈... 采用环境舱模拟研究了随温度(T)、相对湿度(RH)和空气交换率(AER)变化墙体试块中氨的释放规律,并将现场实验结果与环境舱的模拟实验结果进行对比.研究发现:T和RH一定,随着AER的增大,舱内氨气平衡浓度下降,氨气挥发速率和完全释放时间呈现出一定的规律性;AER和RH一定,舱内氨气平衡浓度和挥发速率随T升高而变大,完全释放时间减小;与AER和T相比,RH对氨气释放的影响有限;通过与现场通风实验和浓度监测结果比较,考虑到室内墙体老化时间等因素,环境舱实验与实际住宅测试得到的结论基本一致.在一般的情况下,使用含尿素防冻剂的住宅,其墙体中氨释放完全大约需要10~32年. 展开更多
关键词 释放 环境舱 混凝土墙体 室内空气质量
下载PDF
船舶舱室污染物传播研究进展 被引量:18
11
作者 周爱民 余涛 沈旭东 《舰船科学技术》 北大核心 2014年第1期10-15,共6页
针对船舶舱室特点,将相关室内污染物传播研究成果系统地总结成3类典型方法,并评价各自优缺点。通过分析各类理论模型在船舶领域的应用现状和前景,指出将其整合运用是模拟船舶舱室污染物传播规律的发展方向,并提出下一步的研究方向,对开... 针对船舶舱室特点,将相关室内污染物传播研究成果系统地总结成3类典型方法,并评价各自优缺点。通过分析各类理论模型在船舶领域的应用现状和前景,指出将其整合运用是模拟船舶舱室污染物传播规律的发展方向,并提出下一步的研究方向,对开展传播舱室污染物的研究具有重要参考价值。 展开更多
关键词 船舶舱室 室内空气品质 污染物传播 INDOOR air quality( iaq)
下载PDF
Experimental study on indoor environment improvement in toll booth by personalized ventilation technology 被引量:2
12
作者 杨华 齐承英 +2 位作者 刘磊 金凤云 闫丙宏 《Journal of Southeast University(English Edition)》 EI CAS 2010年第2期307-310,共4页
The necessity and feasibility of the use of the personalized ventilation(PV)technology in a toll booth is described.First,the indoor environment of the toll booth equipped with a PV system is analyzed.Based on the a... The necessity and feasibility of the use of the personalized ventilation(PV)technology in a toll booth is described.First,the indoor environment of the toll booth equipped with a PV system is analyzed.Based on the analysis results,a set of equipment for controlling the indoor air quality(IAQ)of the toll booth is devised.Then,a full-scale model of the toll booth is set up in the laboratory.The airflow organization,the optimum operation parameters,and the restraint effects of the PV system on pollution are also experimentally studied.The experimental results on the air supply characteristics show that the PV system can effectively reduce the air age,improve the ventilation efficiency,and enhance the comfort and acceptability of human beings.In addition,this system plays a significant role in preventing pollution. 展开更多
关键词 personalized ventilation(PV) indoor air qualityiaq toll booth POLLUTION
下载PDF
温度对建材中可散发甲醛含量的影响 被引量:9
13
作者 张寅平 钱科 +1 位作者 王新轲 熊建银 《工程热物理学报》 EI CAS CSCD 北大核心 2008年第7期1171-1173,共3页
本文采用多平衡态回归法测量了常温下密度板中可散发甲醛含量,并与国标方法萃取法所测结果进行对比。发现材料中的可散发甲醛含量远小于萃取法所测得的总含量,说明建材中的甲醛很大一部分在常温下无法释放出来。
关键词 室内空气品质(iaq) 有机挥发物(VOCs) 建材 散发
下载PDF
我国室内空气质量与评价方法研究进展 被引量:17
14
作者 但德忠 谭和平 方正 《中国测试技术》 CAS 2005年第5期115-120,共6页
当前我国室内空气污染十分严重,只有通过室内空气质量评价才能够了解室内环境污染水平和对健康的可能影响,并针对性地提出控制措施。本文介绍了室内空气质量和室内空气污染的定义、由来、研究对象以及相关内容,综合分析了室内空气质量... 当前我国室内空气污染十分严重,只有通过室内空气质量评价才能够了解室内环境污染水平和对健康的可能影响,并针对性地提出控制措施。本文介绍了室内空气质量和室内空气污染的定义、由来、研究对象以及相关内容,综合分析了室内空气质量的影响因素,并比较了我国与国外室内环境研究的状况I、AQ标准I、AQ评价指标研究的进展情况,同时提出了我国IAQ对策。 展开更多
关键词 室内环境 室内空气质量(iaq) 污染 标准 评价方法
下载PDF
装饰装修后房屋内有害物质检测结果分析 被引量:7
15
作者 杨志琼 朱万明 +3 位作者 彭一萍 苏桂华 李钰 万衍 《现代预防医学》 CAS 北大核心 2008年第5期853-854,共2页
[目的]了解室内装饰装修工程竣工后的空气质量,为控制室内环境空气质量提供依据。[方法]按《室内空气质量标准GB/T18883-2002》及其附录的要求,对乐山城区近3年来的部分室内装饰装修房屋的空气质量相应卫生指标做了检测。[结果]室内装... [目的]了解室内装饰装修工程竣工后的空气质量,为控制室内环境空气质量提供依据。[方法]按《室内空气质量标准GB/T18883-2002》及其附录的要求,对乐山城区近3年来的部分室内装饰装修房屋的空气质量相应卫生指标做了检测。[结果]室内装饰装修后:可吸入颗粒(PM10)、甲醛、苯、甲苯、二甲苯超标率分别为94.0%、43%、29%、12%、18%。[结论]室内装饰装修工程所使用的材料必须有质量检验合格证和相应的中文标识并符合相关的国家标准。 展开更多
关键词 空气质量 室内装饰装修 检出限
下载PDF
换气量对地板送风房间可吸入颗粒物浓度的影响 被引量:5
16
作者 李灿 李念平 姚国财 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2007年第12期26-29,共4页
可吸入颗粒物浓度是影响室内空气品质的重要因素.为了研究地板送风空调系统室内空气品质,分析了室内可吸入颗粒物浓度影响因素,建立了关于颗粒物浓度的模型,求出其分析解,并提出'颗粒物浓度准稳定时间'因子作为反映房间颗粒物... 可吸入颗粒物浓度是影响室内空气品质的重要因素.为了研究地板送风空调系统室内空气品质,分析了室内可吸入颗粒物浓度影响因素,建立了关于颗粒物浓度的模型,求出其分析解,并提出'颗粒物浓度准稳定时间'因子作为反映房间颗粒物浓度衰减速度的参数.基于该模型的解析结果,发现换气量是通风时对房间颗粒浓度最重要的影响因素.在一间地板送风全比例模型房间内进行了实验,实验验证了所建立的模型能正确有效地预测可吸入颗粒物浓度的变化.结果表明:加大换气量可以使地板送风空调系统室内可吸入颗粒物浓度降低且颗粒物浓度准稳定时间缩短. 展开更多
关键词 颗粒物 换气量 室内空气品质
下载PDF
舰船舱室挥发性有机化合物的释放速率研究 被引量:7
17
作者 张锦岚 余涛 +2 位作者 姜国宝 孙新福 赵俊涛 《中国舰船研究》 CSCD 北大核心 2018年第1期93-98,共6页
[目的]为保障舰员健康与舰船的安全运行,应对以挥发性有机化合物(VOC)为代表的舱内空气污染物进行有效控制。污染物的释放速率是表征舱室空气质量的关键参数之一,但目前在该方面的研究还较为欠缺。[方法]基于常规室内环境污染速率测试方... [目的]为保障舰员健康与舰船的安全运行,应对以挥发性有机化合物(VOC)为代表的舱内空气污染物进行有效控制。污染物的释放速率是表征舱室空气质量的关键参数之一,但目前在该方面的研究还较为欠缺。[方法]基于常规室内环境污染速率测试方法,结合舰船舱室特点,通过Tenax-TA采样管富集采样、ATD-GC/MS分析和集总参数模型拟合,对舱室内以苯、甲苯、乙苯和二甲苯(BTEX)为代表的VOC释放速率进行研究。选取某舰船典型舱室为研究对象,开展封舱与通风工况下BTEX的释放速率测量试验。[结果]结果表明:通风工况下,该舱室二甲苯和挥发性有机化合物总量(TVOC)的平衡浓度均超出了室内空气质量标准,应加强污染源头控制或改善通风净化效能;封舱工况下(舱室环境浓度与通风工况接近),除浓度较低的苯以外,BTEX的释放速率与通风工况下的测试结果吻合较好。[结论]该研究初步建立了适用于舰船舱室的VOC释放速率测量方法,可为其污染特征评估与通风净化系统设计提供参考。 展开更多
关键词 舰船舱室 挥发性有机化合物 释放速率 室内空气质量
下载PDF
一种评价挥发性有机物污染水平的室内空气质量健康指数 被引量:9
18
作者 王超 赵彬 杨旭东 《中南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2014年第6期2099-2104,共6页
为使室内人员更好地了解自己所身处的室内空气环境的品质,提出一种评价挥发性有机物(VOCs)污染水平的室内空气质量健康指数,该指数选取10种室内常见的挥发性有机物作为索引污染物,基于这些污染物的健康效应将室内空气质量分为6级,以实... 为使室内人员更好地了解自己所身处的室内空气环境的品质,提出一种评价挥发性有机物(VOCs)污染水平的室内空气质量健康指数,该指数选取10种室内常见的挥发性有机物作为索引污染物,基于这些污染物的健康效应将室内空气质量分为6级,以实测数据为例对该指数的使用进行说明。实验结果表明:相比传统的报告浓度的方法,健康指数可更为清晰地指示室内空气品质。通过应用该指数,居住者可直观地了解自己所身处的室内环境中的空气品质,并且对于指导实际工程中改善室内空气质量的相关技术应用有一定指导意义。 展开更多
关键词 室内空气品质(iaq) 健康效应 挥发性有机物(VOCs) 健康指数
下载PDF
舰船典型舱室装修后挥发性有机化合物的实测与分析 被引量:3
19
作者 余涛 朱求源 +3 位作者 郑谦 赵俊涛 莫金汉 张寅平 《船舶工程》 CSCD 北大核心 2018年第2期103-107,共5页
选取装修结束并持续通风3天后的某舰船典型舱室为研究对象,在码头停泊状态采用Tenax TA采样管富集采样和ATD-GC/MS方法测量舱室挥发性有机化合物(VOCs)的释放特征,利用NIST08谱库和标准物质进行定性和定量分析。研究发现,装修后舰船舱... 选取装修结束并持续通风3天后的某舰船典型舱室为研究对象,在码头停泊状态采用Tenax TA采样管富集采样和ATD-GC/MS方法测量舱室挥发性有机化合物(VOCs)的释放特征,利用NIST08谱库和标准物质进行定性和定量分析。研究发现,装修后舰船舱室环境VOCs浓度水平显著高于装修前,舱室封闭期间(>4 h)典型苯系物和总挥发性有机化合物(TVOC)释放速率基本恒定,其中浓度最高且释放速率最大的VOCs包括二甲苯、环己酮和乙苯等。因此,建议加强舰船装修期间的材料使用和施工工艺管理,从源头上控制装修污染,并在装修过程中和结束后加强通风。 展开更多
关键词 舰船舱室 挥发性有机化合物 装修污染 室内空气质量
下载PDF
新风预处理概念、系统与应用 被引量:11
20
作者 李芃 沈晋明 《暖通空调》 北大核心 2002年第6期104-107,共4页
美国《ASHRAE标准 62 - 1 999》要求增大空调系统的设计新风量 ,降低室内相对湿度以提高室内空气品质。这样 ,空调系统的冷、湿负荷将增大。据此 ,提出了新风预处理概念 ,它是在基本保持原有的传统空气处理系统不变的前提下 ,对新风进... 美国《ASHRAE标准 62 - 1 999》要求增大空调系统的设计新风量 ,降低室内相对湿度以提高室内空气品质。这样 ,空调系统的冷、湿负荷将增大。据此 ,提出了新风预处理概念 ,它是在基本保持原有的传统空气处理系统不变的前提下 ,对新风进行合适的预处理 ,以消除增加的新风对空调对象的干扰 ,从而经济有效地改善室内空气品质。最后 ,给出了几种新风预处理系统及应用。 展开更多
关键词 室内 空气品质 新风预处理 热回收 除湿
下载PDF
上一页 1 2 7 下一页 到第
使用帮助 返回顶部