Objective: To report 32 cases of femur supracondylar fracture treated with retrograde interlocking intramedullary nails in elderly patients. Methods: According to the AO classification, all of 32 cases were classifi...Objective: To report 32 cases of femur supracondylar fracture treated with retrograde interlocking intramedullary nails in elderly patients. Methods: According to the AO classification, all of 32 cases were classified as extra-articular type A. 32 cases were treated with interlocking intramedullary nail by closed insertion from intercondylar fossa of the knee. All cases accepted CPM exercise as early as possible after operation. Results: Following up 5 to 15 months, all fractures united within an average duration of 5.3 months (4-7 months). According to the Shelbourne scale, the excellent rate of the knee function was 86.3%. Conclusion: Retrograde interlocking intramedullary nail is useful alternative implant for the treatment of osteoporotic supracondylar fracture of femur, particularly of the type A fracture in the elderly population. Its merits include stable fixation, high rate of fracture union and few complications.展开更多
Objective: To evaluate the therapeutic effects of retrograde interlocking intramedullary nailing under arthroscopy on supracondylar femoral fractures. Methods: From June 1999 to December 2000, 17 patients with supraco...Objective: To evaluate the therapeutic effects of retrograde interlocking intramedullary nailing under arthroscopy on supracondylar femoral fractures. Methods: From June 1999 to December 2000, 17 patients with supracondylar femoral fracture were treated with arthroscopically assisted implantation of retrograde interlocking intramedullary nail and close reduction. Results: More than 6 month follow up study after operation in 11 patients revealed that the average healing time was 3 months. Average range of the knee motion for all the patients was more than 90 degrees. There was no implant breakage and infection. Conclusions: This new method, combining the advantage of arthroscope and retrograde interlocking intramedullary nail, can provide a stable and reliable fixation, and meanwhile is less invasive to the soft tissue and knee, less operative time and blood loss, minimal disruption of the blood supply in fracture site. It is conducive to the fracture healing and the functional recovery of the knee joint and worthwhile to be recommended.展开更多
AIM: To define the optimum safe angle of use for an eccentrically aligned proximal interlocking screw(PIS) for intramedullary nailing(IMN).METHODS: Thirty-six dry cadaver ulnas were split into two equal pieces sagital...AIM: To define the optimum safe angle of use for an eccentrically aligned proximal interlocking screw(PIS) for intramedullary nailing(IMN).METHODS: Thirty-six dry cadaver ulnas were split into two equal pieces sagitally. The following points were identified for each ulna: the deepest point of the incisura olecrani(A), the point where perpendicular lines from A and the ideal IMN entry point(D) are intersected(C) and a point at 3.5 mm(2 mm safety distance from articular surface + 1.5 mm radius of PIS) posterior from point A(B). We calculated the angle of screws inserted from point D through to point B in relation to D-C and B-C. In addition, an eccentrically aligned screw was inserted at a standard 20° through the anterior cortex of the ulna in each bone and the articular surface wasobserved macroscopically for any damage.RESULTS: The mean A-C distance was 9.6 mm(mean ± SD, 9.600 ± 0.763 mm), A-B distance was 3.5 mm, C-D distance was 12.500 mm(12.500 ± 1.371 mm) and the mean angle was 25.9°(25.9°± 2.0°). Lack of articular damage was confirmed macroscopically in all bones after the 20.0° eccentrically aligned screws were inserted. Intramedullary nail fixation systems have well known biological and biomechanical advantages for osteosynthesis. However, as well as these well-known advantages, IMN fixation of the ulna has some limitations. Some important limitations are related to the proximal interlocking of the ulna nail. The location of the PIS itself limits the indications for which intramedullary systems can be selected as an implant for the ulna. The new PIS design, where the PIS is aligned 20°eccentrically to the nail body, allows fixing of fractures even at the level of the olecranon without disturbing the joint. It also allows the eccentrically aligned screw to be inserted in any direction except through the proximal radio-ulnar joint. Taking into consideration our results, we now use a 20° eccentrically aligned PIS for all ulnas. In our results, the angle required to insert the PIS was less than 20° for only one bone. However, 0.7° difference corresponds to placement of the screw only 0.2 mm closer to the articular surface. As we assume 2.0 mm to be a safe distance, a placement of the screw 0.2 mm closer to the articular surface may not produce any clinical symptoms.CONCLUSION: The new PIS may give us the opportunity to interlock IMN without articular damage and confirmation by fluoroscopy if the nail is manufactured with a PIS aligned at a 20.0° fixed angle in relation to the IMN.展开更多
Background: Newer generation intramedullary (IM) tibial nails provide several distal interlocking screw options. The objectives were to determine: 1) if the new oblique interlocking option provides superior stability,...Background: Newer generation intramedullary (IM) tibial nails provide several distal interlocking screw options. The objectives were to determine: 1) if the new oblique interlocking option provides superior stability, 2) which screw orientation/ configuration is the most biomechanically stable, and 3) if three distal interlocking screws provide better stability. Methods: A preliminary experiment was performed in torsion, compression, and bending tests with four different screw configurations: (I) one medial-to-lateral and one oblique, (II) two me-dial-to-lateral, (III) one medial-to-lateral and one anterior-to-posterior, and (IV) one medial-to-lateral, one anterior-to-posterior and one oblique in simu-lated distal metaphyseal fracture tibiae. Twenty- four Synthes EXPERT tibial IM nails were used for six specimens of each screw configuration. Parts I and II, tibial IM nails were locked with 5.0 mm in-terlocking screws into simulated distal tibiae (PVC and composite analogue tibia). Part III, the two most stable configurations were tested using five pairs of simulated cadaveric distal tibiae metaphy-seal fractures. Results: Significant differences were attributable to distal screw orientation for intrame- dullary nailing of distal tibia fractures. Configura-tions II and IV were found to be more stable than the other two configurations. No significant differ-ence was detected in construct stability in all modes of testing between Configurations II and IV. Dis-cussion: Configuration I did not provide superior stability for the distal tibia fracture fixation. Con-figurations II and IV provided equivalent stability. When choosing IM fixation for treatment of distal tibia metaphyseal fractures two medial-to-lateral screws provide the necessary stability for satisfac-tory fixation. Clinical Relevance: This study indi-cated an option for operative treatment of distal metaphyseal tibia fracture fixation where preserva-tion of soft tissue and rigid stabilization are needed.展开更多
A study was performed in adults to determine the efficacy of closed reduction and intramedullary nailing in dynamic mode on union, implant failure and incidence of malalignment in patients who sustained an extra-artic...A study was performed in adults to determine the efficacy of closed reduction and intramedullary nailing in dynamic mode on union, implant failure and incidence of malalignment in patients who sustained an extra-articular fracture of the distal tibia. Methods: Between January 2007 and December 2013, one hundred and twelve patients of distal tibia that involved the distal 6 cm of the tibia were treated at our hospital with reamed intramedullary nailing with use of two distal interlocking screws and one proximal screw in dynamic mode. The augmentation was done with poller screws whenever it was necessary. The nailing of fibular fractures was done in 27 cases. There were 85 males and 27 females with a mean age of 30.9 (range: 20 to 72). Eighty fractures were closed whereas 32 were grade 1 open fractures. Results: The average time to union of the closed fracture was 15.4 weeks (range: 12 – 28 weeks). The healing times for the primarily nailed compound Grade I averaged 17.8 (range: 15 - 34 weeks). After minimum follow-up of one year, rate of primary union was in 97.32%. One case of broken nail required revision surgery. There were three cases of delayed union and two cases of non union. In one case there was deep infection which required exchange nailing with antibiotic impregnated nail. There was breakage of interlocking screws in three cases but fracture had united. In twenty two cases acceptable malalignment of the tibia was observed after union. The outcome was determined at a minimum of one year in our study based on the criteria of Johner and Wruhs. Out of 112 patients, 79 patients had excellent results, 29 had good results and 4 had fair results. Conclusions: The dynamic osteosynthesis of distal tibia by interlocking nail and judicious use of poller screws is an effective alternative for the treatment of distal metaphyseal tibial fractures.展开更多
文摘Objective: To report 32 cases of femur supracondylar fracture treated with retrograde interlocking intramedullary nails in elderly patients. Methods: According to the AO classification, all of 32 cases were classified as extra-articular type A. 32 cases were treated with interlocking intramedullary nail by closed insertion from intercondylar fossa of the knee. All cases accepted CPM exercise as early as possible after operation. Results: Following up 5 to 15 months, all fractures united within an average duration of 5.3 months (4-7 months). According to the Shelbourne scale, the excellent rate of the knee function was 86.3%. Conclusion: Retrograde interlocking intramedullary nail is useful alternative implant for the treatment of osteoporotic supracondylar fracture of femur, particularly of the type A fracture in the elderly population. Its merits include stable fixation, high rate of fracture union and few complications.
文摘Objective: To evaluate the therapeutic effects of retrograde interlocking intramedullary nailing under arthroscopy on supracondylar femoral fractures. Methods: From June 1999 to December 2000, 17 patients with supracondylar femoral fracture were treated with arthroscopically assisted implantation of retrograde interlocking intramedullary nail and close reduction. Results: More than 6 month follow up study after operation in 11 patients revealed that the average healing time was 3 months. Average range of the knee motion for all the patients was more than 90 degrees. There was no implant breakage and infection. Conclusions: This new method, combining the advantage of arthroscope and retrograde interlocking intramedullary nail, can provide a stable and reliable fixation, and meanwhile is less invasive to the soft tissue and knee, less operative time and blood loss, minimal disruption of the blood supply in fracture site. It is conducive to the fracture healing and the functional recovery of the knee joint and worthwhile to be recommended.
文摘AIM: To define the optimum safe angle of use for an eccentrically aligned proximal interlocking screw(PIS) for intramedullary nailing(IMN).METHODS: Thirty-six dry cadaver ulnas were split into two equal pieces sagitally. The following points were identified for each ulna: the deepest point of the incisura olecrani(A), the point where perpendicular lines from A and the ideal IMN entry point(D) are intersected(C) and a point at 3.5 mm(2 mm safety distance from articular surface + 1.5 mm radius of PIS) posterior from point A(B). We calculated the angle of screws inserted from point D through to point B in relation to D-C and B-C. In addition, an eccentrically aligned screw was inserted at a standard 20° through the anterior cortex of the ulna in each bone and the articular surface wasobserved macroscopically for any damage.RESULTS: The mean A-C distance was 9.6 mm(mean ± SD, 9.600 ± 0.763 mm), A-B distance was 3.5 mm, C-D distance was 12.500 mm(12.500 ± 1.371 mm) and the mean angle was 25.9°(25.9°± 2.0°). Lack of articular damage was confirmed macroscopically in all bones after the 20.0° eccentrically aligned screws were inserted. Intramedullary nail fixation systems have well known biological and biomechanical advantages for osteosynthesis. However, as well as these well-known advantages, IMN fixation of the ulna has some limitations. Some important limitations are related to the proximal interlocking of the ulna nail. The location of the PIS itself limits the indications for which intramedullary systems can be selected as an implant for the ulna. The new PIS design, where the PIS is aligned 20°eccentrically to the nail body, allows fixing of fractures even at the level of the olecranon without disturbing the joint. It also allows the eccentrically aligned screw to be inserted in any direction except through the proximal radio-ulnar joint. Taking into consideration our results, we now use a 20° eccentrically aligned PIS for all ulnas. In our results, the angle required to insert the PIS was less than 20° for only one bone. However, 0.7° difference corresponds to placement of the screw only 0.2 mm closer to the articular surface. As we assume 2.0 mm to be a safe distance, a placement of the screw 0.2 mm closer to the articular surface may not produce any clinical symptoms.CONCLUSION: The new PIS may give us the opportunity to interlock IMN without articular damage and confirmation by fluoroscopy if the nail is manufactured with a PIS aligned at a 20.0° fixed angle in relation to the IMN.
文摘Background: Newer generation intramedullary (IM) tibial nails provide several distal interlocking screw options. The objectives were to determine: 1) if the new oblique interlocking option provides superior stability, 2) which screw orientation/ configuration is the most biomechanically stable, and 3) if three distal interlocking screws provide better stability. Methods: A preliminary experiment was performed in torsion, compression, and bending tests with four different screw configurations: (I) one medial-to-lateral and one oblique, (II) two me-dial-to-lateral, (III) one medial-to-lateral and one anterior-to-posterior, and (IV) one medial-to-lateral, one anterior-to-posterior and one oblique in simu-lated distal metaphyseal fracture tibiae. Twenty- four Synthes EXPERT tibial IM nails were used for six specimens of each screw configuration. Parts I and II, tibial IM nails were locked with 5.0 mm in-terlocking screws into simulated distal tibiae (PVC and composite analogue tibia). Part III, the two most stable configurations were tested using five pairs of simulated cadaveric distal tibiae metaphy-seal fractures. Results: Significant differences were attributable to distal screw orientation for intrame- dullary nailing of distal tibia fractures. Configura-tions II and IV were found to be more stable than the other two configurations. No significant differ-ence was detected in construct stability in all modes of testing between Configurations II and IV. Dis-cussion: Configuration I did not provide superior stability for the distal tibia fracture fixation. Con-figurations II and IV provided equivalent stability. When choosing IM fixation for treatment of distal tibia metaphyseal fractures two medial-to-lateral screws provide the necessary stability for satisfac-tory fixation. Clinical Relevance: This study indi-cated an option for operative treatment of distal metaphyseal tibia fracture fixation where preserva-tion of soft tissue and rigid stabilization are needed.
文摘A study was performed in adults to determine the efficacy of closed reduction and intramedullary nailing in dynamic mode on union, implant failure and incidence of malalignment in patients who sustained an extra-articular fracture of the distal tibia. Methods: Between January 2007 and December 2013, one hundred and twelve patients of distal tibia that involved the distal 6 cm of the tibia were treated at our hospital with reamed intramedullary nailing with use of two distal interlocking screws and one proximal screw in dynamic mode. The augmentation was done with poller screws whenever it was necessary. The nailing of fibular fractures was done in 27 cases. There were 85 males and 27 females with a mean age of 30.9 (range: 20 to 72). Eighty fractures were closed whereas 32 were grade 1 open fractures. Results: The average time to union of the closed fracture was 15.4 weeks (range: 12 – 28 weeks). The healing times for the primarily nailed compound Grade I averaged 17.8 (range: 15 - 34 weeks). After minimum follow-up of one year, rate of primary union was in 97.32%. One case of broken nail required revision surgery. There were three cases of delayed union and two cases of non union. In one case there was deep infection which required exchange nailing with antibiotic impregnated nail. There was breakage of interlocking screws in three cases but fracture had united. In twenty two cases acceptable malalignment of the tibia was observed after union. The outcome was determined at a minimum of one year in our study based on the criteria of Johner and Wruhs. Out of 112 patients, 79 patients had excellent results, 29 had good results and 4 had fair results. Conclusions: The dynamic osteosynthesis of distal tibia by interlocking nail and judicious use of poller screws is an effective alternative for the treatment of distal metaphyseal tibial fractures.