Objective To investigate the operative method and evaluate the clinical outcomes of long proximal femoral nail anti-rotation (PFNA-long) in treating long-segment fracture in middle-up part of femoral bone.Methods From...Objective To investigate the operative method and evaluate the clinical outcomes of long proximal femoral nail anti-rotation (PFNA-long) in treating long-segment fracture in middle-up part of femoral bone.Methods From June 2006 to展开更多
With the aging population,intertrochanteric femur fracture in the elderly has become one of the most serious public health issues and a hot topic of research in trauma orthopedics.Due to the limitations of internal fi...With the aging population,intertrochanteric femur fracture in the elderly has become one of the most serious public health issues and a hot topic of research in trauma orthopedics.Due to the limitations of internal fixation techniques and the insufficient mechanical design of nails,the occurrence of complications delays patient recovery after surgical treatment.Design of a proximal femur bionic nail(PFBN)based on Zhang’s N triangle theory provides triangular supporting fixation,which dramatically decreases the occurrence of complications and has been widely used for clinical treatment of unstable intertrochanteric femur fracture worldwide.In this work,we developed an equivalent biomechanical model to analyze improvement in bone remodeling of unstable intertrochanteric femur fracture through PFBN use.The results show that compared with proximal femoral nail antirotation(PFNA)and InterTan,PFBN can dramatically decrease the maximum strain in the proximal femur.Based on Frost’s mechanostat theory,the local mechanical environment in the proximal femur can be regulated into the medium overload region by using a PFBN,which may render the proximal femur in a state of physiological overload,favoring post-operative recovery of intertrochanteric femur fracture in the elderly.This work shows that PFBN may constitute a panacea for unstable intertrochanteric femur fracture and provides insights into improving methods of internal fixation.展开更多
Purpose:To investigate the clinical value of proximal femoral nail antirotation and anatomical locking plate of proximal femur in the treatment of intertrochanteric fracture of femur.Methods:The study group is treated...Purpose:To investigate the clinical value of proximal femoral nail antirotation and anatomical locking plate of proximal femur in the treatment of intertrochanteric fracture of femur.Methods:The study group is treated with PFNA internal fixation.The control group is treated by internal fixation with anatomical locking plate of proximal femur.Results:The time of operation,the amount of intraoperative bleeding and the time of fracture healing in the study group are significantly less than those in the control group.The incidence rate of complication in the study group(3.23%)is significantly lower than that in the control group(17.2%).Data comparison shows P<0.05.Conclusion:The curative effect and prognosis for patients with intertrochanteric fracture of femur treated by PFNA internal fixation are more ideal.展开更多
Purpose To investigate the clinical value of proximal femoral nail antirotation and anatomical locking plate of proximal femur in the treatment of intertrochanteric fracture of femur.Methods The study group is treated...Purpose To investigate the clinical value of proximal femoral nail antirotation and anatomical locking plate of proximal femur in the treatment of intertrochanteric fracture of femur.Methods The study group is treated with PFNA internal fixation.The control group is treated by internal fixation with anatomical locking plate of proximal femur.Results The time of operation,the amount of intraoperative bleeding and the time of fracture healing in the study group are significantly less than those in the control group.The incidence rate of complication in the study group(3.23%)is significantly lower than that in the control group(17.2%).Data comparison shows P<0.05.Conclusion The curative effect and prognosis for patients with intertrochanteric fracture of femur treated by PFNA internal fixation are more ideal.展开更多
In this editorial,I present my comments on the article by Solarino et al.Conversion hip arthroplasty,which is an optional salvage procedure performed following unsuccessful fixation of intertrochanteric femur fracture...In this editorial,I present my comments on the article by Solarino et al.Conversion hip arthroplasty,which is an optional salvage procedure performed following unsuccessful fixation of intertrochanteric femur fractures in elderly pati-ents,entails more complex processes and higher rates of operative complications than primary arthroplasty.Hence,it is important to consider the appropriateness of the primary treatment choice,as well as the adequacy of nailing fixation for intertrochanteric fractures.This article briefly analyzes the possible factors contributing to the nailing failure of intertrochanteric fractures and attempts to find corresponding countermeasures to prevent fixation failures.It also analyzes the choice of treatment between nailing fixation and primary arthroplasty for intertrochanteric fractures.展开更多
In proximal humeral fracture except AO classification 11A1, fixations with a locking plate and nails are recommended. We performed mechanical tests to investigate whether retrograde intramedullary nailing has fixation...In proximal humeral fracture except AO classification 11A1, fixations with a locking plate and nails are recommended. We performed mechanical tests to investigate whether retrograde intramedullary nailing has fixation stability comparable to those of anterograde intramedullary nailing and locking plate which achieve clinically favorable outcomes. In retrograde intramedullary nailing, a nail entry point is made in the diaphysis, for which reduction of stiffness of the humerus is of concern. Thus, we investigated the influence of a nail entry point made in the diaphysis on humeral strength. Retrograde intramedullary nailing had fixation stability against bending and a force loaded in the rotation direction comparable to those of anterograde intramedullary nail and locking plate. Displacement by the main external force loaded on the humerus, compressive load, was less than half in the bone fixed by retrograde intramedullary nailing compared with that in the bone fixed with a locking plate, showing favorable fixation stability. It was clarified that stiffness of the humerus against rotation and a load in the compression direction is not reduced by a nail entry point made by retrograde intramedullary nailing.展开更多
Intertrochanteric fractures have become a severe public health problem in elderly patients.Proximal femoral nail anti-rotation(PFNA)is a commonly used intramedullary fixation device for unstable intertrochanteric frac...Intertrochanteric fractures have become a severe public health problem in elderly patients.Proximal femoral nail anti-rotation(PFNA)is a commonly used intramedullary fixation device for unstable intertrochanteric fractures.Pelvic perforation by cephalic screw is a rare complication.We reported an 84-year-old female who fell at home and sustained an intertrochanteric fracture.The patient underwent surgery with PFNA as the intramedullary fixation device.Routine postoperative examination revealed medial migration of the helical blade that eventually caused pelvic perforation.We performed a cemented total hip arthroplasty as the savage procedure.At the latest follow-up of 12 months after total hip arthroplasty,the patient had no pain or loosening of the prosthesis in the left hip.Pelvic perforation should be considered when choosing PFNA as the intramedullary fixation device,especially in patients with severe osteoporosis wherein the helical blade can be easily inserted during the operation.The lack of devices to avoid oversliding of the helical blade in PFNA is an unreported cause of this complication and should be considered in such cases.展开更多
Objective: Subtrochanteric femoral fractures are severe injuries. Although many treatment methods have been developed, controversy exists regarding the optimal management of these fractures. This study evaluated the ...Objective: Subtrochanteric femoral fractures are severe injuries. Although many treatment methods have been developed, controversy exists regarding the optimal management of these fractures. This study evaluated the clinical outcome of subtrochanteric femoral fractures fixed with long proximal femoral nail antirotation (PFNA-Iong). Methods: Between October 2006 and February 2008, 25 patients with traumatic subtrochanteric fractures of the femur were treated with PFNA-long. Closed reduction and fixation were performed in 20 cases. In the remaining 5 cases, closed reduction was difficult, so limited open reduction was performed, with bone grafting in 4 cases and circumfer-ential wiring in 4 cases. Results: The average follow-up time was 16.1 months. All subtrochanteric femoral fractures healed uneventfully except one case of delayed union. The mean union time was 26.2 weeks. Technical difficulties with nail insertion were encountered in 3 cases. No implant failure was observed. Conclusion: PFNA-long is effective in treatment of subtrochanteric femoral fractures, with a high rate of bone union, minor soft tissue damage, early return to functional exercise and few implant-related complications.展开更多
Background:The reverse obliquity inter-trochanteric fracture is a distinct fracture pattern that is mechanically different from most inter-trochanteric fractures and the optional treatment of it is still controversial...Background:The reverse obliquity inter-trochanteric fracture is a distinct fracture pattern that is mechanically different from most inter-trochanteric fractures and the optional treatment of it is still controversial.The purpose of this study was to compare differences in the efficacy of a novel nail(medial support nail[MSN-II])and proximal femoral nail anti-rotation(PFNA-II)in the treatment of reverse obliquity inter-trochanteric fractures(Arbeitsgemeinschaft fur Osteosynthesfrogen/Orthopedic Trauma Association[AO/OTA]31-A3.1)using finite-element analysis.Methods:Modeling software was used to establish a three-dimensional model of MSN-II and PFNA-II and an A3.1 inter-trochanteric fracture model.Abaqus software was used to implement different force loads to compare finite-element biomechanical parameters such as the maximum stress in implant and the displacement of fracture site.Results:The femoral stress,implant stress and fracture site displacement of MSN-II was less than that of PFNA-II.The results indicated that the maximal femoral stress was 581 MPa for PFNA-II and 443 MPa for the MSN-II.The maximum stress values in the PFNA-II and MSN-II models were 291 and 241 MPa,respectively.The maximal displacements of the fracture site were 1.47 and 1.16 mm in the PFNA-II and MSN-II models,respectively.Conclusions:Compared with PFNA-II for inter-trochanteric fracture(AO/OTA 31-A3.1),MSN-II which was designed with a triangular stability structure can provide better biomechanical stability.The MSN-II may be a feasible option for the treatment of reverse obliquity inter-trochanteric fracture.展开更多
目的:对比鞘内注射舒芬太尼与芬太尼对高龄股骨粗隆骨折近端股骨钉抗旋(PFNA)内固定术患者的镇痛效果及安全性对比。方法:选取2019年1月—2022年12月于常熟市第五人民医院接受股骨粗隆骨折PFNA内固定术的108例高龄患者作为研究对象,根...目的:对比鞘内注射舒芬太尼与芬太尼对高龄股骨粗隆骨折近端股骨钉抗旋(PFNA)内固定术患者的镇痛效果及安全性对比。方法:选取2019年1月—2022年12月于常熟市第五人民医院接受股骨粗隆骨折PFNA内固定术的108例高龄患者作为研究对象,根据随机数表法将患者分为研究组54例与常规组54例。研究组采用鞘内注射舒芬太尼,常规组采用鞘内注射芬太尼。比较两组手术时间、镇痛时间、术后6 h、12 h视觉模拟评分法(VAS)评分及不良反应发生情况。结果:两组手术时间比较,差异无统计学意义(P>0.05);研究组镇痛时间长于常规组,差异有统计学意义(P<0.05)。研究组术后6 h、12 h VAS评分低于常规组,且两组术后12 h VAS评分低于术后6 h,差异有统计学意义(P<0.05)。研究组不良反应发生率低于常规组,差异有统计学意义(P<0.05)。结论:相比芬太尼,舒芬太尼在高龄股骨粗隆骨折PFNA内固定术患者中的镇痛作用显著,能缓解术后疼痛,还可降低不良反应发生率。展开更多
文摘Objective To investigate the operative method and evaluate the clinical outcomes of long proximal femoral nail anti-rotation (PFNA-long) in treating long-segment fracture in middle-up part of femoral bone.Methods From June 2006 to
基金supported by the National Natural Science Foundation of China(32130052,82072447,and 82272578)the Fundamental Research Funds for the Central Universities,Nankai University(730-C02922112 and 730-DK2300010314).
文摘With the aging population,intertrochanteric femur fracture in the elderly has become one of the most serious public health issues and a hot topic of research in trauma orthopedics.Due to the limitations of internal fixation techniques and the insufficient mechanical design of nails,the occurrence of complications delays patient recovery after surgical treatment.Design of a proximal femur bionic nail(PFBN)based on Zhang’s N triangle theory provides triangular supporting fixation,which dramatically decreases the occurrence of complications and has been widely used for clinical treatment of unstable intertrochanteric femur fracture worldwide.In this work,we developed an equivalent biomechanical model to analyze improvement in bone remodeling of unstable intertrochanteric femur fracture through PFBN use.The results show that compared with proximal femoral nail antirotation(PFNA)and InterTan,PFBN can dramatically decrease the maximum strain in the proximal femur.Based on Frost’s mechanostat theory,the local mechanical environment in the proximal femur can be regulated into the medium overload region by using a PFBN,which may render the proximal femur in a state of physiological overload,favoring post-operative recovery of intertrochanteric femur fracture in the elderly.This work shows that PFBN may constitute a panacea for unstable intertrochanteric femur fracture and provides insights into improving methods of internal fixation.
文摘Purpose:To investigate the clinical value of proximal femoral nail antirotation and anatomical locking plate of proximal femur in the treatment of intertrochanteric fracture of femur.Methods:The study group is treated with PFNA internal fixation.The control group is treated by internal fixation with anatomical locking plate of proximal femur.Results:The time of operation,the amount of intraoperative bleeding and the time of fracture healing in the study group are significantly less than those in the control group.The incidence rate of complication in the study group(3.23%)is significantly lower than that in the control group(17.2%).Data comparison shows P<0.05.Conclusion:The curative effect and prognosis for patients with intertrochanteric fracture of femur treated by PFNA internal fixation are more ideal.
文摘Purpose To investigate the clinical value of proximal femoral nail antirotation and anatomical locking plate of proximal femur in the treatment of intertrochanteric fracture of femur.Methods The study group is treated with PFNA internal fixation.The control group is treated by internal fixation with anatomical locking plate of proximal femur.Results The time of operation,the amount of intraoperative bleeding and the time of fracture healing in the study group are significantly less than those in the control group.The incidence rate of complication in the study group(3.23%)is significantly lower than that in the control group(17.2%).Data comparison shows P<0.05.Conclusion The curative effect and prognosis for patients with intertrochanteric fracture of femur treated by PFNA internal fixation are more ideal.
文摘In this editorial,I present my comments on the article by Solarino et al.Conversion hip arthroplasty,which is an optional salvage procedure performed following unsuccessful fixation of intertrochanteric femur fractures in elderly pati-ents,entails more complex processes and higher rates of operative complications than primary arthroplasty.Hence,it is important to consider the appropriateness of the primary treatment choice,as well as the adequacy of nailing fixation for intertrochanteric fractures.This article briefly analyzes the possible factors contributing to the nailing failure of intertrochanteric fractures and attempts to find corresponding countermeasures to prevent fixation failures.It also analyzes the choice of treatment between nailing fixation and primary arthroplasty for intertrochanteric fractures.
文摘In proximal humeral fracture except AO classification 11A1, fixations with a locking plate and nails are recommended. We performed mechanical tests to investigate whether retrograde intramedullary nailing has fixation stability comparable to those of anterograde intramedullary nailing and locking plate which achieve clinically favorable outcomes. In retrograde intramedullary nailing, a nail entry point is made in the diaphysis, for which reduction of stiffness of the humerus is of concern. Thus, we investigated the influence of a nail entry point made in the diaphysis on humeral strength. Retrograde intramedullary nailing had fixation stability against bending and a force loaded in the rotation direction comparable to those of anterograde intramedullary nail and locking plate. Displacement by the main external force loaded on the humerus, compressive load, was less than half in the bone fixed by retrograde intramedullary nailing compared with that in the bone fixed with a locking plate, showing favorable fixation stability. It was clarified that stiffness of the humerus against rotation and a load in the compression direction is not reduced by a nail entry point made by retrograde intramedullary nailing.
基金National Key R&D Program of China,2018YFF0301103,The funding body will support the publication fees without affecting the diagnosis and treatment of the patient and the writing of the manuscript.
文摘Intertrochanteric fractures have become a severe public health problem in elderly patients.Proximal femoral nail anti-rotation(PFNA)is a commonly used intramedullary fixation device for unstable intertrochanteric fractures.Pelvic perforation by cephalic screw is a rare complication.We reported an 84-year-old female who fell at home and sustained an intertrochanteric fracture.The patient underwent surgery with PFNA as the intramedullary fixation device.Routine postoperative examination revealed medial migration of the helical blade that eventually caused pelvic perforation.We performed a cemented total hip arthroplasty as the savage procedure.At the latest follow-up of 12 months after total hip arthroplasty,the patient had no pain or loosening of the prosthesis in the left hip.Pelvic perforation should be considered when choosing PFNA as the intramedullary fixation device,especially in patients with severe osteoporosis wherein the helical blade can be easily inserted during the operation.The lack of devices to avoid oversliding of the helical blade in PFNA is an unreported cause of this complication and should be considered in such cases.
文摘Objective: Subtrochanteric femoral fractures are severe injuries. Although many treatment methods have been developed, controversy exists regarding the optimal management of these fractures. This study evaluated the clinical outcome of subtrochanteric femoral fractures fixed with long proximal femoral nail antirotation (PFNA-Iong). Methods: Between October 2006 and February 2008, 25 patients with traumatic subtrochanteric fractures of the femur were treated with PFNA-long. Closed reduction and fixation were performed in 20 cases. In the remaining 5 cases, closed reduction was difficult, so limited open reduction was performed, with bone grafting in 4 cases and circumfer-ential wiring in 4 cases. Results: The average follow-up time was 16.1 months. All subtrochanteric femoral fractures healed uneventfully except one case of delayed union. The mean union time was 26.2 weeks. Technical difficulties with nail insertion were encountered in 3 cases. No implant failure was observed. Conclusion: PFNA-long is effective in treatment of subtrochanteric femoral fractures, with a high rate of bone union, minor soft tissue damage, early return to functional exercise and few implant-related complications.
基金This work was supported by a grant from the Capital Health Research and Development of Special Grants(No.2016-1-5012)。
文摘Background:The reverse obliquity inter-trochanteric fracture is a distinct fracture pattern that is mechanically different from most inter-trochanteric fractures and the optional treatment of it is still controversial.The purpose of this study was to compare differences in the efficacy of a novel nail(medial support nail[MSN-II])and proximal femoral nail anti-rotation(PFNA-II)in the treatment of reverse obliquity inter-trochanteric fractures(Arbeitsgemeinschaft fur Osteosynthesfrogen/Orthopedic Trauma Association[AO/OTA]31-A3.1)using finite-element analysis.Methods:Modeling software was used to establish a three-dimensional model of MSN-II and PFNA-II and an A3.1 inter-trochanteric fracture model.Abaqus software was used to implement different force loads to compare finite-element biomechanical parameters such as the maximum stress in implant and the displacement of fracture site.Results:The femoral stress,implant stress and fracture site displacement of MSN-II was less than that of PFNA-II.The results indicated that the maximal femoral stress was 581 MPa for PFNA-II and 443 MPa for the MSN-II.The maximum stress values in the PFNA-II and MSN-II models were 291 and 241 MPa,respectively.The maximal displacements of the fracture site were 1.47 and 1.16 mm in the PFNA-II and MSN-II models,respectively.Conclusions:Compared with PFNA-II for inter-trochanteric fracture(AO/OTA 31-A3.1),MSN-II which was designed with a triangular stability structure can provide better biomechanical stability.The MSN-II may be a feasible option for the treatment of reverse obliquity inter-trochanteric fracture.
文摘目的:对比鞘内注射舒芬太尼与芬太尼对高龄股骨粗隆骨折近端股骨钉抗旋(PFNA)内固定术患者的镇痛效果及安全性对比。方法:选取2019年1月—2022年12月于常熟市第五人民医院接受股骨粗隆骨折PFNA内固定术的108例高龄患者作为研究对象,根据随机数表法将患者分为研究组54例与常规组54例。研究组采用鞘内注射舒芬太尼,常规组采用鞘内注射芬太尼。比较两组手术时间、镇痛时间、术后6 h、12 h视觉模拟评分法(VAS)评分及不良反应发生情况。结果:两组手术时间比较,差异无统计学意义(P>0.05);研究组镇痛时间长于常规组,差异有统计学意义(P<0.05)。研究组术后6 h、12 h VAS评分低于常规组,且两组术后12 h VAS评分低于术后6 h,差异有统计学意义(P<0.05)。研究组不良反应发生率低于常规组,差异有统计学意义(P<0.05)。结论:相比芬太尼,舒芬太尼在高龄股骨粗隆骨折PFNA内固定术患者中的镇痛作用显著,能缓解术后疼痛,还可降低不良反应发生率。