An approach of the incompatible elements with additional internal shear strain is,in the presem paper,suggested and applied to geometrically nonlinear analysis of Mi-ndlin plate bending problem.It provides a quite cov...An approach of the incompatible elements with additional internal shear strain is,in the presem paper,suggested and applied to geometrically nonlinear analysis of Mi-ndlin plate bending problem.It provides a quite covenient way to avoid the whear loc-king troubles.An energy consistency condition for this kind of C°elements is offered.The nonlinear element formulations and some numerical results are presented.展开更多
Objective:To analyze the effect of locking compression plate on the success rate of operation and the time of postoperative recovery.Methods:120 patients with limb fractures from March 2018 to March 2020 were randomly...Objective:To analyze the effect of locking compression plate on the success rate of operation and the time of postoperative recovery.Methods:120 patients with limb fractures from March 2018 to March 2020 were randomly divided into control group(60 cases)and observation group(60 cases).The control group was treated with plate screw internal fixation,The observation group used locking compression plate internal fixation,Compare the effect of treatment,the success rate of operation and the time of postoperative recovery.results:compared the effective rate of the two groups,the observation group(93.33%)was significantly higher than the control group(75.00%).Compared with the two groups,the success rate of operation and the time of postoperative recovery,the observed composition power was higher than that of the control group,and the postoperative recovery time was lower than that of the control group,P<0.05.Conclusion:The use of locking compression plate for the treatment of limb fracture can significantly increase the probability of successful operation,shorten the recovery time after operation,the overall curative effect is ideal,and the clinical popularization value is high.展开更多
Objective:To evaluate functional outcome and complications of open reduction and internal fixation with proximal humeral internal locking system (PHILOS) plate for proximal humerus fractures.Methods:We reviewed 51...Objective:To evaluate functional outcome and complications of open reduction and internal fixation with proximal humeral internal locking system (PHILOS) plate for proximal humerus fractures.Methods:We reviewed 51 patients who underwent open reduction and internal fixation with PHILOS plate between the years 2007 to 2012.There were 35 men and 16 women with a mean age of 38 years (range 24-68).There were 41 patients in the age group of <60 years and 10 patients in the age group of >60 years.According to Neer classification system,8,15 and 23 patients had 2-part,3-part,and 4-part fractures,respectively and 5 patients had 4-part fracture dislocation.All surgeries were carried out at our tertiary care trauma centre.Functional evaluation of the shoulder at final follow-up was done using Constant-Murley score.Results:The mean follow-up period was 30 months (range 12-44 months).Two patients were lost to followup.Of the remaining 49 patients,all fractures were united clinically and radiologically.The mean time for radiological union was 12 weeks (range 8-20 weeks).At the final follow-up the mean Constant-Murley score was 79 (range 50-100).The results were excellent in 25 patients,good in 13 patients,fair in 6 patients and poor in 5 patients.During the follow-up,four cases of varus malunion,one case of subacromial impingement,one case of deep infection,one case of intraarticular screw penetration and one case of failure of fixation were noted.No cases of avascular necrosis,hardware failure,locking screw loosening or nonunion were noted.Conclusion:PHILOS provides stable fixation in proximal humerus fractures.To prevent potential complications like avascular necrosis,meticulous surgical dissection to preserve vascularity of humeral head is necessary.展开更多
文摘An approach of the incompatible elements with additional internal shear strain is,in the presem paper,suggested and applied to geometrically nonlinear analysis of Mi-ndlin plate bending problem.It provides a quite covenient way to avoid the whear loc-king troubles.An energy consistency condition for this kind of C°elements is offered.The nonlinear element formulations and some numerical results are presented.
文摘Objective:To analyze the effect of locking compression plate on the success rate of operation and the time of postoperative recovery.Methods:120 patients with limb fractures from March 2018 to March 2020 were randomly divided into control group(60 cases)and observation group(60 cases).The control group was treated with plate screw internal fixation,The observation group used locking compression plate internal fixation,Compare the effect of treatment,the success rate of operation and the time of postoperative recovery.results:compared the effective rate of the two groups,the observation group(93.33%)was significantly higher than the control group(75.00%).Compared with the two groups,the success rate of operation and the time of postoperative recovery,the observed composition power was higher than that of the control group,and the postoperative recovery time was lower than that of the control group,P<0.05.Conclusion:The use of locking compression plate for the treatment of limb fracture can significantly increase the probability of successful operation,shorten the recovery time after operation,the overall curative effect is ideal,and the clinical popularization value is high.
文摘Objective:To evaluate functional outcome and complications of open reduction and internal fixation with proximal humeral internal locking system (PHILOS) plate for proximal humerus fractures.Methods:We reviewed 51 patients who underwent open reduction and internal fixation with PHILOS plate between the years 2007 to 2012.There were 35 men and 16 women with a mean age of 38 years (range 24-68).There were 41 patients in the age group of <60 years and 10 patients in the age group of >60 years.According to Neer classification system,8,15 and 23 patients had 2-part,3-part,and 4-part fractures,respectively and 5 patients had 4-part fracture dislocation.All surgeries were carried out at our tertiary care trauma centre.Functional evaluation of the shoulder at final follow-up was done using Constant-Murley score.Results:The mean follow-up period was 30 months (range 12-44 months).Two patients were lost to followup.Of the remaining 49 patients,all fractures were united clinically and radiologically.The mean time for radiological union was 12 weeks (range 8-20 weeks).At the final follow-up the mean Constant-Murley score was 79 (range 50-100).The results were excellent in 25 patients,good in 13 patients,fair in 6 patients and poor in 5 patients.During the follow-up,four cases of varus malunion,one case of subacromial impingement,one case of deep infection,one case of intraarticular screw penetration and one case of failure of fixation were noted.No cases of avascular necrosis,hardware failure,locking screw loosening or nonunion were noted.Conclusion:PHILOS provides stable fixation in proximal humerus fractures.To prevent potential complications like avascular necrosis,meticulous surgical dissection to preserve vascularity of humeral head is necessary.