期刊文献+
共找到44,056篇文章
< 1 2 250 >
每页显示 20 50 100
Surgical site soft tissue thickness as a predictor of complications following arthroplasty
1
作者 Kevin A Wu Faheem Pottayil +2 位作者 Crystal Jing Ankit Choudhury Albert T Anastasio 《World Journal of Methodology》 2025年第2期62-73,共12页
Appreciation of soft-tissue thickness(STT)at surgical sites is an increasingly recognized aspect of arthroplasty procedures as it may potentially impacting postoperative outcomes.Recent research has focused on the pre... Appreciation of soft-tissue thickness(STT)at surgical sites is an increasingly recognized aspect of arthroplasty procedures as it may potentially impacting postoperative outcomes.Recent research has focused on the predictive value of preoperative STT measurements for complications following various forms of arthroplasty,particularly infections,across procedures such as total knee,hip,shoulder,and ankle replacements.Several studies have indicated that increased STT is associated with a higher risk of complications,including infection and wound healing issues.The assessment of STT before surgery could play a crucial role in identifying patients at a higher risk of complications and may be instru-mental in guiding preoperative planning to optimize outcomes in arthroplasty procedures.Standardized measurement techniques and further research are essential to enhance the reliability and clinical utility of STT assessment for arthro-plasty surgery. 展开更多
关键词 Soft-tissue thickness ARTHROPLASTY Surgical complications Total knee arthroplasty Total hip arthroplasty Total shoulder arthroplasty Total ankle arthroplasty Preoperative assessment Wound healing Infection risk
下载PDF
Correlation Study of Aortic Velocity Propagation, Abdominal Aortic Intima-Media Thickness, and Epicardial Adipose Tissue Thickness in Subclinical Hypothyroidism Patients
2
作者 Juan Luo Jiaqi Chen +2 位作者 Yueyi Li Jingfeng Li Nengwen Lin 《Journal of Clinical and Nursing Research》 2024年第8期153-158,共6页
Objective:To explore the correlation between epicardial fat thickness(EFT),aortic velocity propagation(AVP),and abdominal aortic intima-media thickness(AA-IMT)in patients with subclinical hypothyroidism(SH).Additional... Objective:To explore the correlation between epicardial fat thickness(EFT),aortic velocity propagation(AVP),and abdominal aortic intima-media thickness(AA-IMT)in patients with subclinical hypothyroidism(SH).Additionally,to compare these indicators between SH patients and healthy individuals,providing a new theoretical basis for the clinical prevention and treatment of cardiovascular diseases.Method:Clinical data from 50 SH patients(23 males and 27 females)and 50 healthy outpatient examinees(22 males and 28 females)were analyzed.The participants were selected from January 2022 to December 2023 at Loudi Central Hospital.EFT,AVP,and AA-IMT were measured,and their correlations were analyzed.Results:SH patients had significantly higher EFT and AA-IMT levels than the control group,while their AVP was significantly lower,with these differences being statistically significant(P<0.05).Correlation analysis revealed a significant negative correlation between EFT and AVP(P<0.001),a significant positive correlation between EFT and AAO-IMT(P<0.001),and a significant negative correlation between AVP and AAO-IMT(P<0.001).Multivariate binary logistic regression analysis identified increased EFT,decreased AVP,and increased AAO-IMT as independent risk factors for SH patients.Conclusion:In SH patients,EFT and AAO-IMT are elevated,whereas AVP is reduced.EFT and AVP are significantly correlated with AAO-IMT.EFT and AAO-IMT can serve as reliable indicators for evaluating subclinical atherosclerosis in SH patients,providing a diagnostic basis for clinical practice. 展开更多
关键词 Epicardial fat thickness Aortic propagation velocity Abdominal aortic intima-media thickness Subclinical hypothyroidism
下载PDF
Evaluation of retinal and choroidal thickness changes in overweight and obese adults without ocular symptoms by swept-source optical coherence tomography 被引量:1
3
作者 Qing-Jian Li Sheng-Mei Zhou +7 位作者 Ling-Yu Zhang An-Ni Lin Yang Zhang Jing Jiang Xin Che Yi-Wen Qian Yan Liu Zhi-Liang Wang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第4期707-712,共6页
AIM:To evaluate the relationship of overweight and obesity with retinal and choroidal thickness in adults without ocular symptoms by swept-source optical coherence tomography(SS-OCT).METHODS:According to the body mass... AIM:To evaluate the relationship of overweight and obesity with retinal and choroidal thickness in adults without ocular symptoms by swept-source optical coherence tomography(SS-OCT).METHODS:According to the body mass index(BMI)results,the adults enrolled in the cross-sectional study were divided into the normal group(18.50≤BMI<25.00 kg/m^(2)),the overweight group(25.00≤BMI<30.00 kg/m^(2)),and the obesity group(BMI≥30.00 kg/m^(2)).The one-way ANOVA and the Chi-square test were used for comparisons.Pearson’s correlation analysis was used to evaluate the relationships between the measured variables.RESULTS:This research covered the left eyes of 3 groups of 434 age-and sex-matched subjects each:normal,overweight,and obesity.The mean BMI was 22.20±1.67,26.82±1.38,and 32.21±2.35 kg/m^(2) in normal,overweight and obesity groups,respectively.The choroid was significantly thinner in both the overweight and obesity groups compared to the normal group(P<0.05 for all),while the retinal thickness of the three groups did not differ significantly.Pearson’s correlation analysis showed that BMI was significantly negatively correlated with choroidal thickness,but no significant correlation was observed between BMI and retinal thickness.CONCLUSION:Choroidal thickness is decreased in people with overweight or obesity.Research on changes in choroidal thickness contributes to the understanding of the mechanisms of certain ocular disorders in overweight and obese adults. 展开更多
关键词 OVERWEIGHT OBESITY body mass index choroidal thickness retinal thickness swept-source optical coherence tomography
下载PDF
Influence of layer thickness on formation quality,microstructure,mechanical properties,and corrosion resistance of WE43 magnesium alloy fabricated by laser powder bed fusion 被引量:2
4
作者 Bangzhao Yin Jinge Liu +7 位作者 Bo Peng Mengran Zhou Bingchuan Liu Xiaolin Ma Caimei Wang Peng Wen Yun Tian Yufeng Zheng 《Journal of Magnesium and Alloys》 SCIE EI CAS CSCD 2024年第4期1367-1385,共19页
Laser powder bed fusion(L-PBF)of Mg alloys has provided tremendous opportunities for customized production of aeronautical and medical parts.Layer thickness(LT)is of great significance to the L-PBF process but has not... Laser powder bed fusion(L-PBF)of Mg alloys has provided tremendous opportunities for customized production of aeronautical and medical parts.Layer thickness(LT)is of great significance to the L-PBF process but has not been studied for Mg alloys.In this study,WE43 Mg alloy bulk cubes,porous scaffolds,and thin walls with layer thicknesses of 10,20,30,and 40μm were fabricated.The required laser energy input increased with increasing layer thickness and was different for the bulk cubes and porous scaffolds.Porosity tended to occur at the connection joints in porous scaffolds for LT40 and could be eliminated by reducing the laser energy input.For thin wall parts,a large overhang angle or a small wall thickness resulted in porosity when a large layer thicknesses was used,and the porosity disappeared by reducing the layer thickness or laser energy input.A deeper keyhole penetration was found in all occasions with porosity,explaining the influence of layer thickness,geometrical structure,and laser energy input on the porosity.All the samples achieved a high fusion quality with a relative density of over 99.5%using the optimized laser energy input.The increased layer thickness resulted to more precipitation phases,finer grain sizes and decreased grain texture.With the similar high fusion quality,the tensile strength and elongation of bulk samples were significantly improved from 257 MPa and 1.41%with the 10μm layer to 287 MPa and 15.12%with the 40μm layer,in accordance with the microstructural change.The effect of layer thickness on the compressive properties of porous scaffolds was limited.However,the corrosion rate of bulk samples accelerated with increasing the layer thickness,mainly attributed to the increased number of precipitation phases. 展开更多
关键词 Magnesium alloy WE43 Laser powder bed fusion Layer thickness Process optimization
下载PDF
Non-linear relationship between age and subfoveal choroidal thickness in Chinese patients with proliferative diabetic retinopathy 被引量:1
5
作者 Chun-Yan Lei Jiang-Ying Xie +1 位作者 Qi-Bo Ran Mei-Xia Zhang 《World Journal of Diabetes》 SCIE 2024年第9期1903-1915,共13页
BACKGROUND No study has investigated the change regularity between age and subfoveal choroidal thickness(SFCT)in proliferative diabetic retinopathy(PDR).AIM To investigate the relationship between the SFCT and age in ... BACKGROUND No study has investigated the change regularity between age and subfoveal choroidal thickness(SFCT)in proliferative diabetic retinopathy(PDR).AIM To investigate the relationship between the SFCT and age in Chinese patients with PDR.METHODS This was a cross-sectional retrospective study.The participants were hospitalized individuals with type 2 diabetes who underwent vitrectomy for PDR.Contralateral eyes that met the criteria were included in the study.All necessary laboratory tests were performed at the time of admission.Central macular thickness(CMT)and SFCT were two quantitative assessments made using enhanced depth imaging optical coherence tomography.CMT was measured automatically and SFCT was measured manually with digital calipers provided by the Heidelberg Eye Explorer software.RESULTS The final analysis included a total of 234 individuals with PDR.The average age was 55.60 years old±10.03 years old,and 57.69%of the population was male.Univariate analysis revealed a significant negative connection between age and SFCT in patients with PDR[β=-2.44,95%confidence interval(95%CI):-3.46 to-1.42;P<0.0001].In the fully adjusted model,the correlation between SFCT and age remained steady(β=-1.68,95%CI:-2.97 to-0.39;P=0.0117).Spline smoothing showed that the relationship between SFCT and age in patients with PDR was non-linear,with an inflection point at 54 years of age.CONCLUSION Our findings suggest that age is a key determinant of choroidal thickness.The non-linear link between SFCT and age in PDR patients should be taken into account. 展开更多
关键词 Age Subfoveal choroidal thickness Proliferative diabetic retinopathy Optical coherence tomography Central macular thickness
下载PDF
Using choroidal thickness to detect myopic macular degeneration 被引量:2
6
作者 Ran Liu Meng Xuan +10 位作者 De-Cai Wang Ou Xiao Xin-Xing Guo Jian Zhang Wei Wang Monica Jong Padmaja Sankaridurg Kyoko Ohno-Matsui Qiu-Xia Yin Ming-Guang He Zhi-Xi Li 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第2期317-323,共7页
AIM:To explore the usage of choroidal thickness measured by swept-source optical coherence tomography(SS-OCT)to detect myopic macular degeneration(MMD)in high myopic participants.METHODS:Participants with bilateral hi... AIM:To explore the usage of choroidal thickness measured by swept-source optical coherence tomography(SS-OCT)to detect myopic macular degeneration(MMD)in high myopic participants.METHODS:Participants with bilateral high myopia(≤−6 diopters)were recruited from a subset of the Guangzhou Zhongshan Ophthalmic Center-Brien Holden Vision Institute High Myopia Cohort Study.SS-OCT was performed to determine the choroidal thickness,and myopic maculopathy was graded by the International Meta-Analysis for Pathologic Myopia(META-PM)Classification.Presence of MMD was defined as META-PM category 2 or above.RESULTS:A total of 568 right eyes were included for analysis.Eyes with MMD(n=106,18.7%)were found to have older age,longer axial lengths(AL),higher myopic spherical equivalents(SE),and reduced choroidal thickness in each Early Treatment Diabetic Retinopathy Study(ETDRS)grid sector(P<0.001).The area under the receiver operating characteristic(ROC)curves(AUC)for subfoveal choroidal thickness(0.907)was greater than that of the model,including age,AL,and SE at 0.6249,0.8208,and 0.8205,respectively.The choroidal thickness of the inner and outer nasal sectors was the most accurate indicator of MMD(AUC of 0.928 and 0.923,respectively).An outer nasal sector choroidal thickness of less than 74μm demonstrated the highest odds of predicting MMD(OR=33.8).CONCLUSION:Choroidal thickness detects the presence of MMD with high agreement,particularly of the inner and outer nasal sectors of the posterior pole,which appears to be a biometric parameter more precise than age,AL,or SE. 展开更多
关键词 high myopia choroidal thickness myopic macular degeneration swept-source optical coherence tomography
下载PDF
Pipeline thickness estimation using the dispersion of higher-order SH guided waves 被引量:1
7
作者 代政辰 刘金霞 +3 位作者 龙云飞 张建海 Tribikram Kundu 崔志文 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第7期389-396,共8页
Thickness measurement plays an important role in the monitoring of pipeline corrosion damage. However, the requirement for prior knowledge of the shear wave velocity in the pipeline material for popular ultrasonic thi... Thickness measurement plays an important role in the monitoring of pipeline corrosion damage. However, the requirement for prior knowledge of the shear wave velocity in the pipeline material for popular ultrasonic thickness measurement limits its widespread application. This paper proposes a method that utilizes cylindrical shear horizontal(SH) guided waves to estimate pipeline thickness without prior knowledge of shear wave velocity. The inversion formulas are derived from the dispersion of higher-order modes with the high-frequency approximation. The waveform of the example problems is simulated using the real-axis integral method. The data points on the dispersion curves are processed in the frequency domain using the wave-number method. These extracted data are then substituted into the derived formulas. The results verify that employing higher-order SH guided waves for the evaluation of thickness and shear wave velocity yields less than1% error. This method can be applied to both metallic and non-metallic pipelines, thus opening new possibilities for health monitoring of pipeline structures. 展开更多
关键词 pipeline wall thickness higher-order modes SH guided waves DISPERSION
下载PDF
Assessments of Data-Driven Deep Learning Models on One-Month Predictions of Pan-Arctic Sea Ice Thickness 被引量:1
8
作者 Chentao SONG Jiang ZHU Xichen LI 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 2024年第7期1379-1390,共12页
In recent years,deep learning methods have gradually been applied to prediction tasks related to Arctic sea ice concentration,but relatively little research has been conducted for larger spatial and temporal scales,ma... In recent years,deep learning methods have gradually been applied to prediction tasks related to Arctic sea ice concentration,but relatively little research has been conducted for larger spatial and temporal scales,mainly due to the limited time coverage of observations and reanalysis data.Meanwhile,deep learning predictions of sea ice thickness(SIT)have yet to receive ample attention.In this study,two data-driven deep learning(DL)models are built based on the ConvLSTM and fully convolutional U-net(FC-Unet)algorithms and trained using CMIP6 historical simulations for transfer learning and fine-tuned using reanalysis/observations.These models enable monthly predictions of Arctic SIT without considering the complex physical processes involved.Through comprehensive assessments of prediction skills by season and region,the results suggest that using a broader set of CMIP6 data for transfer learning,as well as incorporating multiple climate variables as predictors,contribute to better prediction results,although both DL models can effectively predict the spatiotemporal features of SIT anomalies.Regarding the predicted SIT anomalies of the FC-Unet model,the spatial correlations with reanalysis reach an average level of 89%over all months,while the temporal anomaly correlation coefficients are close to unity in most cases.The models also demonstrate robust performances in predicting SIT and SIE during extreme events.The effectiveness and reliability of the proposed deep transfer learning models in predicting Arctic SIT can facilitate more accurate pan-Arctic predictions,aiding climate change research and real-time business applications. 展开更多
关键词 Arctic sea ice thickness deep learning spatiotemporal sequence prediction transfer learning
下载PDF
A possible probe to neutron-skin thickness by fragment parallel momentum distribution in projectile fragmentation reactions 被引量:1
9
作者 Chun-Wang Ma Yi-Jie Duan +5 位作者 Ya-Fei Guo Chun-Yuan Qiao Yu-Ting Wang Jie Pu Kai-Xuan Cheng Hui-Ling Wei 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第6期114-119,共6页
Neutron-skin thickness is a key parameter for a neutron-rich nucleus;however,it is difficult to determine.In the framework of the Lanzhou Quantum Molecular Dynamics(LQMD)model,a possible probe for the neutron-skin thi... Neutron-skin thickness is a key parameter for a neutron-rich nucleus;however,it is difficult to determine.In the framework of the Lanzhou Quantum Molecular Dynamics(LQMD)model,a possible probe for the neutron-skin thickness(δ_(np))of neutron-rich ^(48)Ca was studied in the 140A MeV ^(48)Ca+^(9)Be projectile fragmentation reaction based on the parallel momentum distribution(p∥)of the residual fragments.A Fermi-type density distribution was employed to initiate the neutron density distributions in the LQMD simulations.A combined Gaussian function with different width parameters for the left side(Γ_(L))and the right side(Γ_(R))in the distribution was used to describe the p∥of the residual fragments.Taking neutron-rich sulfur isotopes as examples,Γ_(L) shows a sensitive correlation withδ_(np) of ^(48)Ca,and is proposed as a probe for determining the neutron skin thickness of the projectile nucleus. 展开更多
关键词 Neutron-skin thickness Projectile fragmentation Parallel momentum distribution Neutron-rich nucleus Quantum molecular dynamics model
下载PDF
Tailoring MXene Thickness and Functionalization for Enhanced Room‑Temperature Trace NO_(2) Sensing 被引量:2
10
作者 Muhammad Hilal Woochul Yang +1 位作者 Yongha Hwang Wanfeng Xie 《Nano-Micro Letters》 SCIE EI CAS CSCD 2024年第5期71-86,共16页
In this study,precise control over the thickness and termination of Ti3C2TX MXene flakes is achieved to enhance their electrical properties,environmental stability,and gas-sensing performance.Utilizing a hybrid method... In this study,precise control over the thickness and termination of Ti3C2TX MXene flakes is achieved to enhance their electrical properties,environmental stability,and gas-sensing performance.Utilizing a hybrid method involving high-pressure processing,stirring,and immiscible solutions,sub-100 nm MXene flake thickness is achieved within the MXene film on the Si-wafer.Functionalization control is achieved by defunctionalizing MXene at 650℃ under vacuum and H2 gas in a CVD furnace,followed by refunctionalization with iodine and bromine vaporization from a bubbler attached to the CVD.Notably,the introduction of iodine,which has a larger atomic size,lower electronegativity,reduce shielding effect,and lower hydrophilicity(contact angle:99°),profoundly affecting MXene.It improves the surface area(36.2 cm^(2) g^(-1)),oxidation stability in aqueous/ambient environments(21 days/80 days),and film conductivity(749 S m^(-1)).Additionally,it significantly enhances the gas-sensing performance,including the sensitivity(0.1119Ωppm^(-1)),response(0.2% and 23%to 50 ppb and 200 ppm NO_(2)),and response/recovery times(90/100 s).The reduced shielding effect of the–I-terminals and the metallic characteristics of MXene enhance the selectivity of I-MXene toward NO2.This approach paves the way for the development of stable and high-performance gas-sensing two-dimensional materials with promising prospects for future studies. 展开更多
关键词 Controlled MXene thickness Gaseous functionalization approach Lower electronegativity functional groups Enhanced MXene stability Trace NO_(2)sensing
下载PDF
Three-dimensional choroidal vascularity index and choroidal thickness in fellow eyes of acute and chronic primary angle-closure using swept-source optical coherence tomography 被引量:1
11
作者 Hai-Li Huang Guan-Hong Wang +1 位作者 Liang-Liang Niu Xing-Huai Sun 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第1期42-52,共11页
AIM:To compare the three-dimensional choroidal vascularity index(CVI)and choroidal thickness between fellow eyes of acute primary angle-closure(F-APAC)and chronic primary angle-closure glaucoma(F-CPACG)and the eyes of... AIM:To compare the three-dimensional choroidal vascularity index(CVI)and choroidal thickness between fellow eyes of acute primary angle-closure(F-APAC)and chronic primary angle-closure glaucoma(F-CPACG)and the eyes of normal controls.METHODS:This study included 37 patients with unilateral APAC,37 with asymmetric CPACG without prior treatment,and 36 healthy participants.Using swept-source optical coherence tomography(SS-OCT),the macular and peripapillary choroidal thickness and three-dimensional CVI were measured and compared globally and sectorally.Pearson’s correlation analysis and multivariate regression models were used to evaluate choroidal thickness or CVI with related factors.RESULTS:The mean subfoveal CVIs were 0.35±0.10,0.33±0.09,and 0.29±0.04,and the mean subfoveal choroidal thickness were 315.62±52.92,306.22±59.29,and 262.69±45.55μm in the F-APAC,F-CPACG,and normal groups,respectively.All macular sectors showed significantly higher CVIs and choroidal thickness in the F-APAC and F-CPACG eyes than in the normal eyes(P<0.05),while there were no significant differences between the F-APAC and F-CPACG eyes.In the peripapillary region,the mean overall CVIs were 0.21±0.08,0.20±0.08,and 0.19±0.05,and the mean overall choroidal thickness were 180.45±54.18,174.82±50.67,and 176.18±37.94μm in the F-APAC,F-CPACG,and normal groups,respectively.There were no significant differences between any of the two groups in all peripapillary sectors.Younger age,shorter axial length,and the F-APAC or F-CPACG diagnosis were significantly associated with higher subfoveal CVI and thicker subfoveal choroidal thickness(P<0.05).CONCLUSION:The fellow eyes of unilateral APAC or asymmetric CPACG have higher macular CVI and choroidal thickness than those of the normal controls.Neither CVI nor choroidal thickness can distinguish between eyes predisposed to APAC or CPACG.A thicker choroid with a higher vascular volume may play a role in the pathogenesis of primary angle-closure glaucoma. 展开更多
关键词 choroidal thickness choroidal vascularity index swept-source optical coherence tomography acute primary angle-closure chronic primary angle-closure glaucoma
下载PDF
Correlation between Waist Circumference and Carotid Intima-Media Thickness in Women from Shanghai, China 被引量:4
12
作者 SHEN Yun ZHANG Lei +7 位作者 ZONG Wen Hong WANG Zheng ZHANG Yin YANG Man Jing MA Xiao Jing ZHU Jia An BAO YuQian JIA Wei Ping 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2013年第7期531-538,共8页
Objective To evaluate whether waist circumference (WC) 〉85 cm is related to asymptomatic preclinical atherosclerosis in women from Shanghai, China. Methods A total of 2365 females aged 〉20 years recruited from 4 c... Objective To evaluate whether waist circumference (WC) 〉85 cm is related to asymptomatic preclinical atherosclerosis in women from Shanghai, China. Methods A total of 2365 females aged 〉20 years recruited from 4 communities underwent physical examination and carotid artery scanning. Their carotid intima-media thickness (C-iMT) was measured. Results The C-IMT was significantly higher in overweight or obese women with their BMI 〉25.0 kg/m2 {P〈O.01) and in those with their WC _〉85 cm than in those with their WC 〈85 cm (P〈O.01). Spearman and partial correlation analysis showed that the C-IMT was significantly correlated with WC which was independent of menopausal status. The C-IMT significantly increased with the increasing WC and reached to a platform in about 85 cm. An increment tendency was found in the subgroup with its WC 〈 85 cm (P〈O.01) while no significant tendency was found in the subgroup with its WC_〉85 cm (P=0.07). Multiple stepwise regression analysis showed that the WC was an independent risk factor for C-IMT. In logistic regression model, the odd ratio of WC _〉80 cm, _〉80 cm and 〈85 cm and 〉85 cm for evaluating the risk of C-IMT elevation was 2.632, 2.501, and 1.878, respectively. Conclusion WC is significantly correlated with C-IMT in women from Shanghai, China, and WC_〉85 cm may be used in identifying the risk of subclinical carotid atherosclerosis. 展开更多
关键词 Visceral obesity Waist circumference Carotid intima-media thickness
下载PDF
Relationship between Waist Circumference and Elevation of Carotid Intima-media Thickness in Newly-diagnosed Diabetic Patients 被引量:2
13
作者 ZHANG Lei SHEN Yun +7 位作者 ZHOU Jian PAN Jie Min YU Hao Yong CHEN Hai Bing LI Qing LI Ming BAO Yu Qian JIA Wei Ping 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2014年第5期335-342,共8页
Objective Waist circumference, as a brief indicator of visceral obesity, is associated with multi-metabolic disorders and cardiovascular diseases. The present study was aimed to find out the relationship between waist... Objective Waist circumference, as a brief indicator of visceral obesity, is associated with multi-metabolic disorders and cardiovascular diseases. The present study was aimed to find out the relationship between waist circumference and carotid intima media thickness (C-IMT), as well as the best waist circumference cutoff for identifying C-IMT elevation in Chinese male patients with newly-diagnosed diabetes. Methods Five hundred and seventy-eight patients from Department of Endocrinology and Metabolism in Shanghai Sixth People's Hospital affiliated to Shanghai Jiao Tong University were enrolled. Both physical examination (for measurement of waist circumference) and carotid ultrasonography (for measurement of C-IMT) were performed. Results After grouping according to the quartiles of C-IMT, the waist circumference increased across all its quartiles. The waist circumference in 3rd and 4th quartiles (90.7_+9.8 cm and 90.8+9.6 cm) was significant higher than in 1st and 2nd quartiles (P〈0.05). When subjects were divided into 4 groups according to waist circumference, the C-IMT of subjects with waist circumference 90-95 cm was significant higher than that of subjects with waist circumference 85-90 cm and less than 85 cm respectively (P〈0.05). Both spearman and partial correlation analysis showed that C-IMT was positively correlated with waist circumference (P〈0.01). C-IMT was found significantly elevated with the increase of waist circumference. Multiple stepwise regression analysis showed that waist circumference was one of the independent risk factors of C-IMT. After an average of 2.23_+0.85 years follow up, there was a significant elevation of C-IMT in the group with baseline waist circumference over 90 cm P〈0.05), while no significant difference was detected in the group with baseline waist circumference less than 90 cm (P=0.27). Logistic regression showed that baseline waist circumference over 90 cm was associated with a relative risk to C-IMT elevation of 1.132 (95% CI 1.043-1.431, P〈0.05). Conclusion Among newly-diagnosed diabetic male patients, waist circumference over 90 cm not only reflects sub-clinical atherosclerosis in early stage, but also predicts the progression of atherosclerosis. 展开更多
关键词 Waist circumference Carotid intima media thickness Metabolic syndrome
下载PDF
Effects of layer thickness on desiccation cracking behaviour of a vegetated soil 被引量:1
14
作者 Congying Li Qing Cheng +3 位作者 Chaosheng Tang Yingdong Gu Lingxin Cui Haowen Guo 《Biogeotechnics》 2024年第2期47-53,共7页
The objective of this study is to explore how different layer thicknesses affect the desiccation cracking behaviour of vegetated soil.During the experiment,an electronic balance was employed to quantify water evaporat... The objective of this study is to explore how different layer thicknesses affect the desiccation cracking behaviour of vegetated soil.During the experiment,an electronic balance was employed to quantify water evaporation,while a digital camera was utilized to capture the initiation and progression of soil surface cracking.Results indicate that in the early drying process,the rate of evapotranspiration in vegetated soil correlates positively with leaf biomass.For soil samples with the same layer thickness,the constant rate stage duration is consistently shorter in vegetated soil samples than in their bare soil counterparts.As the layer thickness increases,both vegetated and bare soil samples crack at higher water content.However,vegetated soil samples crack at lower water content than their bare soil counterparts.Vegetation significantly reduces the soil surface crack ratio and improves the soil crack resistance.The crack reduction ratio is positively correlated with both root weight and length density.In thicker vegetated soil layers,the final surface crack length noticeably declines. 展开更多
关键词 Desiccation crack Vegetated soil Layer thickness Root density
下载PDF
Determining the effective elastic thickness through cross-correlation between isostatic disturbances
15
作者 Nelson Ribeiro-Filho Cristiano Mendel Martins +2 位作者 Raissa Moraes Baldez Ivaldevingles Rodrigues de Souza Júnior Franck Eitel Kemgang Ghomsi 《Geodesy and Geodynamics》 EI CSCD 2024年第3期241-251,共11页
The elastic thickness parameter was estimated using the mobile correlation technique between the observed isostatic disturbance and the gravity disturbance calculated through direct gravimetric modeling. We computed t... The elastic thickness parameter was estimated using the mobile correlation technique between the observed isostatic disturbance and the gravity disturbance calculated through direct gravimetric modeling. We computed the vertical flexure value of the crust for a specific elastic thickness using a given topographic dataset. The gravity disturbance due to the topography was determined after the calculation. A grid of values for the elastic thickness parameter was generated. Then, a moving correlation was performed between the observed gravity data(representing actual surface data) and the calculated data from the forward modeling. The optimum elastic thickness of the particular point corresponded to the highest correlation coefficient. The methodology was tested on synthetic data and showed that the synthetic depth closely matched the original depth, including the elastic thickness value. To validate the results, the described procedure was applied to a real dataset from the Barreirinhas Basin, situated in the northeastern region of Brazil. The results show that the obtained crustal depth is highly correlated with the depth from known models. Additionally, we noted that the elastic thickness behaves as expected, decreasing from the continent towards the ocean. Based on the results, this method has the potential to be employed as a direct estimate of crustal depth and elastic thickness for any region. 展开更多
关键词 ISOSTASY Elastic thickness Isostatic disturbance Moho depth CROSS-CORRELATION
下载PDF
Ultrasound Assessraent of Intima-media Thickness and Diameter of Carotid Arteries in Patients Undergoing Hemodialysis or Renal Transplantation 被引量:1
16
作者 Zhao-jun Li Lian-fang DU +2 位作者 Yan QIN Ji-bin LIU Xiang-hong LUO 《Current Medical Science》 SCIE CAS 2018年第4期727-733,共7页
Renal transplant (RT) recipients have a high risk of developing cardiovascular diseases. However, the effects of renal transplantation on the development of arteriosclerosis have been controversial. The carotid inti... Renal transplant (RT) recipients have a high risk of developing cardiovascular diseases. However, the effects of renal transplantation on the development of arteriosclerosis have been controversial. The carotid intima-media thickness (CIMT) and diameter (CD) are important indicators of vascular remodeling and arteriosclerosis. In this study, 31 patients with hemodialysis (HD), 31 RT recipients and 84 age- and gender-matched control subjects were enrolled. Their CIMT and CD were measured by ultrasonic radiofrequency tracking, and the linear regression models and Z test were used to identify the progression of arteriosclerosis and the risk factors. Compared with HD group, RT group had significantly lower CIMT and CD. CIMT was found to be associated with age, body weight, resistance index and diastolic velocity, while CD was associated significantly with age, body weight, pulsatility index, end diastolic velocity and diastolic blood pressure (DBP), respectively. The correlation curves between CIMT and age showed the slopes of curves were decreased successively in control, RT and HD groups, and the curves between CD and age showed the slopes were decreased in order of RT 〉 control 〉 HD groups. It was concluded that CIMT and CD were significantly correlated with age in RT and moderately with age in HD patients. RT could reduce the progress of arteriosclerosis in patients with end-stage renal disease. 展开更多
关键词 ultrasonic radiofrequency tracking renal transplantation ARTERIOSCLEROSIS carotid intima-media thickness age
下载PDF
Design and application of thickness measurement calibration system based on laser displacement sensor
17
作者 SUN Jin YU Zijin 《Baosteel Technical Research》 CAS 2024年第2期39-46,共8页
This study aims to improve the accuracy and safety of steel plate thickness calibration.A differential noncontact thickness measurement calibration system based on laser displacement sensors was designed to address th... This study aims to improve the accuracy and safety of steel plate thickness calibration.A differential noncontact thickness measurement calibration system based on laser displacement sensors was designed to address the problems of low precision of traditional contact thickness gauges and radiation risks of radiation-based thickness gauges.First,the measurement method and measurement structure of the thickness calibration system were introduced.Then,the hardware circuit of the thickness system was established based on the STM32 core chip.Finally,the system software was designed to implement system control to filter algorithms and human-computer interaction.Experiments have proven the excellent performance of the differential noncontact thickness measurement calibration system based on laser displacement sensors,which not only considerably improves measurement accuracy but also effectively reduces safety risks during the measurement process.The system offers guiding significance and application value in the field of steel plate production and processing. 展开更多
关键词 steel plate thickness high precision measurement noncontact thickness measurement laser displace-ment sensor
下载PDF
Isotopic dependence of the yield ratios of light fragments from different projectiles and their unified neutron skin thicknesses
18
作者 Ting-Zhi Yan Shan Li 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第3期228-236,共9页
The yield ratios of neutron-proton(R(n/p))and^(3)H-^(3)He(R(^(3)H∕^(3)He))with reduced rapidity from 0 to 0.5 were simulated at 50 MeV/u even-even ^(36−56)Ca+^(40)Ca,even-even ^(48−78)Ni+^(58)Ni,and ^(100−139)Sn(ever... The yield ratios of neutron-proton(R(n/p))and^(3)H-^(3)He(R(^(3)H∕^(3)He))with reduced rapidity from 0 to 0.5 were simulated at 50 MeV/u even-even ^(36−56)Ca+^(40)Ca,even-even ^(48−78)Ni+^(58)Ni,and ^(100−139)Sn(every third isotopes)+112 Sn for full reduced impact parameters using the isospin-dependent quantum molecular dynamics(IQMD)model.The neutron and proton density distributions and root-mean-square radii of the reaction systems were obtained using the Skyrme-Hartree-Fock model,which was used for the phase space initialization of the projectile and target in IQMD.We defined the unified neutron skin thickness asΔRnp=<r^(2)>^(1∕2) n−<r^(2)>^(1∕2)p,which was negative for neutron-deficient nuclei.The unifiedΔRnp values for nuclei with the same relative neutron excess from different isotopic chains were nearly equal,except for extreme neutron-rich isotopes,which is a type of scaling behavior.The yield ratios of the three isotopic chain-induced reactions,which depended on the reduced impact parameter and unified neutron skin thickness,were studied.The results showed that both R(n/p)and R(^(3)H∕^(3)He)decreased with a reduced impact parameter for extreme neutron-deficient isotopes;however,they increased with reduced impact parameters for extreme neutron-rich isotopes,and increased with theΔRnp of the projectiles for all reduced impact parameters.In addition,a scaling phenomenon was observed betweenΔR np and the yield ratios in peripheral colli-sions from different isotopic chain projectiles(except for extreme neutron-rich isotopes).Thus,R(n/p)and R(^(3)H∕^(3)He)from peripheral collisions were suggested as experimental probes for extracting the neutron or proton skin thicknesses of non-extreme neutron-rich nuclei from different isotopic chains. 展开更多
关键词 Exotic nuclei Unified neutron skin thickness Yield ratios IQMD
下载PDF
Quality control of ultrasonic measurement of carotid artery intima-media thickness 被引量:2
19
作者 Ying Yang Feng Zhao +4 位作者 Li-Tong Qi Bao-Wei Zhang Feng Chen Sai-Nan Zhu Yong Huo 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2009年第4期222-226,共5页
Background To report quality control methods and baseline reproducibility data of the ultrasound measurements of carotid artery intima-media thickness in the project of Establishment of an Integrated System for Corona... Background To report quality control methods and baseline reproducibility data of the ultrasound measurements of carotid artery intima-media thickness in the project of Establishment of an Integrated System for Coronary Heart Disease Prevention and Treatment. Methods Standard ultrasound scanning and measuring protocols were established by the study group. All sonographers and readers were trained by the carotid ultrasound core lab and all digital ultrasound images were centrally read. Ten subjects were scanned twice (with 1 week interval) by 2 sonographers independently and images were read by a single reader to evaluate the sonographer variability. Twenty subjects' images were read twice (with 1 week interval) by a single reader to assess the reader variability and the reproducibility of IMT measured at different carotid segments. Results The intraclass correlation (ICC) of intra- and inter-sonographer and intra- reader for mean IMT measurements was 0.99, 0.98 and 0.97 respectively; while for max IMT, it was 0.97, 0.99 and 0.95 respectively. Among different carotid segments and sites, ICC for mean 1MT measurements of common carotid (CCA), carotid artery bulb (Bulb), internal carotid artery (ICA), overall near wall and overall far wall was 0.97, 0.99, 0.89, 0.93 and 0.98 respectively. Conclusion The reproducibility of IMT measurements according to our protocol is acceptable, although better reproducibility is found when measuring the mean IMT than max IMT, CCA and Bulb IMT than ICA IMT, and far wall IMT than near wall IMT. 展开更多
关键词 ATHEROSCLEROSIS carotid arteries ULTRASOUND REPRODUCIBILITY intima-media thickness
下载PDF
New quantification of symmetry energy from neutron skin thicknesses of^(48)Ca and^(208)Pb
20
作者 Rong An Shuai Sun +1 位作者 Li-Gang Cao Feng-Shou Zhang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第10期188-196,共9页
Precise knowledge of the nuclear symmetry energy can be tentatively calibrated using multimessenger constraints.The neutron skin thickness of a heavy nucleus is one of the most sensitive indicators for probing the iso... Precise knowledge of the nuclear symmetry energy can be tentatively calibrated using multimessenger constraints.The neutron skin thickness of a heavy nucleus is one of the most sensitive indicators for probing the isovector components of effective interactions in asymmetric nuclear matter.Recent studies have suggested that the experimental data from the CREX and PREX2 collaborations are not mutually compatible with existing nuclear models.In this study,we review the quantification of the slope parameter of the symmetry energy L from the neutron skin thicknesses of^(48)Ca and^(208)Pb.Skyrme energy density functionals classified by various isoscalar incompressibility coefficients K were employed to evaluate the bulk properties of finite nuclei.The calculated results suggest that the slope parameter L deduced from^(208)Pb is sensitive to the compression modulus of symmetric nuclear matter,but not that from^(48)Ca.The effective parameter sets classified by K=220 MeV can provide an almost overlapping range of L from^(48)Ca and^(208)Pb. 展开更多
关键词 Nuclear symmetry energy Neutron skin thickness Energy density functional
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部