Robotic Intra-Operative Ultrasound:Virtual Environments and Parallel Systems 被引量:4
1
作者 Shuangyi Wang James Housden +6 位作者 Tianxiang Bai Hongbin Liu Junghwan Back Davinder Singh Kawal Rhode Zeng-Guang Hou Fei-Yue Wang 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2021年第5期1095-1106,共12页
Robotic intra-operative ultrasound has the potential to improve the conventional practice of diagnosis and procedure guidance that are currently performed manually.Working towards automatic or semi-automatic ultrasoun... Robotic intra-operative ultrasound has the potential to improve the conventional practice of diagnosis and procedure guidance that are currently performed manually.Working towards automatic or semi-automatic ultrasound,being able to define ultrasound views and the corresponding probe poses via intelligent approaches become crucial.Based on the concept of parallel system which incorporates the ingredients of artificial systems,computational experiments,and parallel execution,this paper utilized a recent developed robotic trans-esophageal ultrasound system as the study object to explore the method for developing the corresponding virtual environments and present the potential applications of such systems.The proposed virtual system includes the use of 3 D slicer as the main workspace and graphic user interface(GUI),Matlab engine to provide robotic control algorithms and customized functions,and PLUS(Public software Library for Ultra Sound imaging research)toolkit to generate simulated ultrasound images.Detailed implementation methods were presented and the proposed features of the system were explained.Based on this virtual system,example uses and case studies were presented to demonstrate its capabilities when used together with the physical TEE robot.This includes standard view definition and customized view optimization for pre-planning and navigation,as well as robotic control algorithm evaluations to facilitate real-time automatic probe pose adjustments.To conclude,the proposed virtual system would be a powerful tool to facilitate the further developments and clinical uses of the robotic intra-operative ultrasound systems. 展开更多
关键词 Medical robots parallel intelligence parallel systems robotic-assisted surgery robotic ultrasound
下载PDF
Progress of research in the application of ultrasound technology for the treatment of Alzheimer’s disease
2
作者 Qiuquan Cai Lianghui Meng +5 位作者 Meina Quan Ling Wang Jing Ren Chenguang Zheng Jiajia Yang Dong Ming 《Neural Regeneration Research》 SCIE CAS 2025年第10期2823-2837,共15页
Alzheimer’s disease is a common neurodegenerative disorder defined by decreased reasoning abilities,memory loss,and cognitive deterioration.The presence of the blood-brain barrier presents a major obstacle to the dev... Alzheimer’s disease is a common neurodegenerative disorder defined by decreased reasoning abilities,memory loss,and cognitive deterioration.The presence of the blood-brain barrier presents a major obstacle to the development of effective drug therapies for Alzheimer’s disease.The use of ultrasound as a novel physical modulation approach has garnered widespread attention in recent years.As a safe and feasible therapeutic and drug-delivery method,ultrasound has shown promise in improving cognitive deficits.This article provides a summary of the application of ultrasound technology for treating Alzheimer’s disease over the past 5 years,including standalone ultrasound treatment,ultrasound combined with microbubbles or drug therapy,and magnetic resonance imaging-guided focused ultrasound therapy.Emphasis is placed on the benefits of introducing these treatment methods and their potential mechanisms.We found that several ultrasound methods can open the blood-brain barrier and effectively alleviate amyloid-βplaque deposition.We believe that ultrasound is an effective therapy for Alzheimer’s disease,and this review provides a theoretical basis for future ultrasound treatment methods. 展开更多
关键词 Alzheimer’s disease blood-brain barrier DRUGS magnetic resonance imaging-guided focused ultrasound MICROBUBBLES scanning ultrasound ultrasound ultrasound stimulation
下载PDF
The Correlation of Indices in r-TEG with Intra-operative Blood Loss in Neurosurgical Patients 被引量:4
3
作者 XueZhang XuerongYu YuguangHuang 《Chinese Medical Sciences Journal》 CAS CSCD 2017年第2期69-74,共6页
Objective Intra-operative coagulopathy has a close relationship with blood loss and the prognosis of patients. Rapid-thrombelastography (r-TEG) is a comprehensive assessment of coagulation abnormalities and also an... Objective Intra-operative coagulopathy has a close relationship with blood loss and the prognosis of patients. Rapid-thrombelastography (r-TEG) is a comprehensive assessment of coagulation abnormalities and also an effective way for constructing blood transfusion. This study attempts to investigate the correlation of r-TEG indices with intra-operative hemorrhage. Methods Patients who underwent transphenoidal hypophysectomy and craniotomy from January 15 to April 30, 2013 in Peking Union Medical College hospital were recruited. All patients had pre- and post-operative r-TEG and conventional coagulation tests (CCTs). Patients’ information and intra-operative blood loss as a percentage of estimated blood volume were recorded. Spearman’s correlation analyses were used for discovering the relationship between indices in r-TEG or CCTs and the intra-operative blood loss. The significant correlated index of r-TEG was further investigated using linear regression analysis. Results A total of 181 patients participated in this study. Intra-operative change of α-angle, which reflects the fibrinogen level and function, was the only r-TEG index that correlated with blood loss significantly (P=0.013, r= ?0.184), thus challenging the current empirical cognition of the effects of intra-operative hemorrhage on coagulation. As intra-operative blood loss increased, α-angle decreased, and every 1% loss of estimated blood volume (EBV) led to 0.60 degree decrease of α-angle. As for CCT results, changes of fibrinogen and platelet count were also significantly correlated with blood loss (P=0.015 and P=0.001, respectively).Conclusions Peri-operative change of α-angle, as an index of r-TEG, exhibited a significant negative correlation with intra-operative blood loss. The impact of hemorrhage on fibrinogen, instead of clotting factors, should be scrutinized. 展开更多
关键词 blood transfusion management rapid-thrombelastography intra-operative blood loss neurosurgerya
下载PDF
The Dosimetric Characteristics and Potential Limitation in Clinical Application of a Low Energy Photon Intra-Operative Radiotherapy System 被引量:2
4
作者 Zhenhua Xiao Ouyang Bin +2 位作者 Zhenyu Wang Botian Huang Bixiu Wen 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2015年第2期184-195,共12页
Purpose: To investigate the dosimetric characteristics of a low energy photon intra-operative radiotherapy (IORT) system and explore its potential limitation in clinical application. Methods: A special water phantom, ... Purpose: To investigate the dosimetric characteristics of a low energy photon intra-operative radiotherapy (IORT) system and explore its potential limitation in clinical application. Methods: A special water phantom, a parallel-plate ionization chamber and an electrometer were used to measure the depth dose rate, isotropy of dose distribution in X/Y plane, dosimetry reproducibility of bare probe and spherical applicators of different size which were used in comparison with the system data. Results: The difference in depth dose rate between the measurement and system data for bare probe is -2.16% ± 1.36%, the range of the relative deviation for isotropy in the X/Y plane is between -1.9% and 2.1%. The difference in depth dose rate, transfer coefficient, isotropy in X/Y plane between the measurement and system data for the whole set of spherical applicators is -10.0% - 2.3%, -8.9% - 4.2% and -1.6% - 2.6%, respectively. Higher surface dose rate and steeper gradient depth dose are observed in smaller spherical applicators. The depth dose rate and isotropy for bare probe and spherical applicators have been shown good reproducibility. The uncertainty of measurement is associated with the positioning accuracy, energy response, noise current and correction function f’(R). Conclusions: Thorough commissioning of the low energy photon IORT system helps us better understand the dosimetry characteristics, verify the system data, obtain adequate data for clinical application and routine quality assurance. The steep gradient depth dose and limited treatment range may restrain its potential in clinical application. 展开更多
关键词 intra-operative RADIOTHERAPY Low Energy PHOTON Dosimetry ISOTROPY LIMITATION
下载PDF
Impact of intra-operative cholangiography and parenchymal resection to donor liver function in living donor liver transplantation 被引量:1
5
作者 Feng Gao Xiao Xu +8 位作者 Yang-Bo Zhu Qiang Wei Bin Zhou Xiao-Yong Shen Qi Ling Hai-Yang Xie Jian Wu Wei-Lin Wang Shu-Sen Zheng 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS 2014年第3期259-263,共5页
BACKGROUND: Living donor liver transplantation(LDLT)has been widely accepted over the past decade, and hepatic dysfunction often occurs in the donor in the early stage after liver donation. The present study aimed to ... BACKGROUND: Living donor liver transplantation(LDLT)has been widely accepted over the past decade, and hepatic dysfunction often occurs in the donor in the early stage after liver donation. The present study aimed to evaluate the effect of intraoperative cholangiography(IOC) and parenchymal resection on liver function of donors in LDLT, and to assess the role of IOC in influencing the biliary complications and improving the overall outcome.METHODS: Data from 40 patients who had donated their right lobes for LDLT were analyzed. Total bilirubin(TB), alanine aminotransferase(ALT), aspartate aminotransferase(AST),alkaline phosphatase(ALP) and γ-glutamyl transpeptidase(GGT)at different time points were compared, and the follow-up data and the biliary complications were also analyzed.RESULTS: The ALT and AST values were significantly increased after IOC(P<0.001) and parenchymal resection(P<0.001).However, the median values of TB, ALP and GGT were not significantly influenced by IOC(P>0.05) or parenchymal resection(P>0.05). The biochemical changes caused by IOC or parenchymal resection were not correlated with the degree of post-operative liver injury or the recovery of liver function. The liver functions of the donors after operation were stable, and none of the donors suffered from biliary stenosis or leakage during the follow-up.CONCLUSIONS: IOC and parenchymal resection may induce a transient increase in liver enzymes of donors in LDLT, but do not affect the recovery of liver function after operation. Moreover,the routine IOC is helpful to clarify the division line of the hepatic duct, thus reducing the biliary complication rate. 展开更多
关键词 living donor liver transplantation intra-operative liver imaging liver function HEPATECTOMY
下载PDF
Seeing beneath the surface:Harnessing point-of-care ultrasound for internal jugular vein evaluation 被引量:2
6
作者 Vichayut Chayapinun Abhilash Koratala Taweevat Assavapokee 《World Journal of Cardiology》 2024年第2期73-79,共7页
Point-of-care ultrasound(POCUS)of the internal jugular vein(IJV)offers a noninvasive means of estimating right atrial pressure(RAP),especially in cases where the inferior vena cava is inaccessible or unreliable due to... Point-of-care ultrasound(POCUS)of the internal jugular vein(IJV)offers a noninvasive means of estimating right atrial pressure(RAP),especially in cases where the inferior vena cava is inaccessible or unreliable due to conditions such as liver disease or abdominal surgery.While many clinicians are familiar with visually assessing jugular venous pressure through the internal jugular vein,this method lacks sensitivity.The utilization of POCUS significantly enhances the visualization of the vein,leading to a more accurate identification.It has been demonstrated that combining IJV POCUS with physical examination enhances the specificity of RAP estimation.This review aims to provide a comprehensive summary of the various sonographic techniques available for estimating RAP from the internal jugular vein,drawing upon existing data. 展开更多
关键词 Point-of-care ultrasound Bedside ultrasound Internal jugular vein Right atrial pressure Central venous pressure
下载PDF
Diagnostic and therapeutic role of endoscopic ultrasound in liver diseases:A systematic review and meta-analysis 被引量:4
7
作者 Eyad Gadour Abeer Awad +3 位作者 Zeinab Hassan Khalid Jebril Shrwani Bogdan Miutescu Hussein Hassan Okasha 《World Journal of Gastroenterology》 SCIE CAS 2024年第7期742-758,共17页
BACKGROUND In hepatology,the clinical use of endoscopic ultrasound(EUS)has experienced a notable increase in recent times.These applications range from the diagnosis to the treatment of various liver diseases.Therefor... BACKGROUND In hepatology,the clinical use of endoscopic ultrasound(EUS)has experienced a notable increase in recent times.These applications range from the diagnosis to the treatment of various liver diseases.Therefore,this systematic review summarizes the evidence for the diagnostic and therapeutic roles of EUS in liver diseases.AIM To examine and summarize the current available evidence of the possible roles of the EUS in making a suitable diagnosis in liver diseases as well as the therapeutic accuracy and efficacy.METHODS PubMed,Medline,Cochrane Library,Web of Science,and Google Scholar databases were extensively searched until October 2023.The methodological quality of the eligible articles was assessed using the Newcastle-Ottawa scale or Cochrane Risk of Bias tool.In addition,statistical analyses were performed using the Comprehensive Meta-Analysis software.RESULTS Overall,45 articles on EUS were included(28 on diagnostic role and 17 on therapeutic role).Pooled analysis demonstrated that EUS diagnostic tests had an accuracy of 92.4%for focal liver lesions(FLL)and 96.6%for parenchymal liver diseases.EUS-guided liver biopsies with either fine needle aspiration or fine needle biopsy had low complication rates when sampling FLL and parenchymal liver diseases(3.1%and 8.7%,respectively).Analysis of data from four studies showed that EUS-guided liver abscess had high clinical(90.7%)and technical success(90.7%)without significant complications.Similarly,EUS-guided interventions for the treatment of gastric varices(GV)have high technical success(98%)and GV obliteration rate(84%)with few complications(15%)and rebleeding events(17%).CONCLUSION EUS in liver diseases is a promising technique with the potential to be considered a first-line therapeutic and diagnostic option in selected cases. 展开更多
关键词 Focal liver lesion Liver abscess drainage Fine needle aspiration Gastric varices Endoscopic ultrasound
下载PDF
Endoscopic-ultrasound-guided biliary drainage with placement of electrocautery-enhanced lumen-apposing metal stent for palliation of malignant biliary obstruction:Updated meta-analysis 被引量:7
8
作者 Zu-Xiang Peng Fang-Fang Chen +5 位作者 Wen Tang Xu Zeng Hong-Juan Du Ru-Xian Pi Hong-Ming Liu Xiao-Xiao Lu 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第3期907-920,共14页
BACKGROUND Endoscopic ultrasound-guided biliary drainage using electrocautery-enhanced(ECE)delivery of lumen-apposing metal stent(LAMS)is gradually being re-cognized as a viable palliative technique for malignant bili... BACKGROUND Endoscopic ultrasound-guided biliary drainage using electrocautery-enhanced(ECE)delivery of lumen-apposing metal stent(LAMS)is gradually being re-cognized as a viable palliative technique for malignant biliary obstruction after endoscopic retrograde cholangiopancreatography(ERCP)failure.However,most of the studies that have assessed its efficacy and safety were small and hetero-geneous.Prior meta-analyses of six or fewer studies that were published 2 years ago were therefore underpowered to yield convincing evidence.AIM To update the efficacy and safety of ECE-LAMS for treatment of biliary ob-struction after ERCP failure.METHODS We searched PubMed,EMBASE,and Scopus databases from the inception of the ECE technique to May 13,2022.Primary outcome measure was pooled technical success rate,and secondary outcomes were pooled rates of clinical success,re-intervention,and adverse events.Meta-analysis was performed using a random-effects model following Freeman-Tukey double-arcsine transformation in R soft-ware(version 4.1.3).RESULTS Fourteen eligible studies involving 620 participants were ultimately included.The pooled rate of technical success was 96.7%,and clinical success was 91.0%.Adverse events were reported in 17.5%of patients.Overall reinter-vention rate was 7.3%.Subgroup analyses showed results were generally consistent.CONCLUSION ECE-LAMS has favorable success with acceptable adverse events in relieving biliary obstruction when ERCP is impossible.The consistency of results across most subgroups suggested that this is a generalizable approach. 展开更多
关键词 Biliary obstruction Biliary drainage Electrocautery-enhanced lumen-apposing metal stents Endoscopic ultrasound Endoscopic retrograde cholangiopancreatography failure
下载PDF
Quick and easy assessment of sarcopenia in cirrhosis: Can ultrasound be the solution? 被引量:1
9
作者 Francesca Campani Tancredi Vincenzo Li Cavoli +3 位作者 Umberto Arena Fabio Marra Erica Nicola Lynch Claudia Campani 《World Journal of Gastroenterology》 SCIE CAS 2024年第17期2287-2293,共7页
Cirrhosis is frequently associated with sarcopenia,with reported rates of over 80%in patients with decompensated alcohol-related liver disease.Sarcopenia nega-tively impacts the prognosis of cirrhotic patients and aff... Cirrhosis is frequently associated with sarcopenia,with reported rates of over 80%in patients with decompensated alcohol-related liver disease.Sarcopenia nega-tively impacts the prognosis of cirrhotic patients and affects the response to treatment of patients with hepatocellular carcinoma(HCC).For these reasons,identifying an easy-to-perform method to assess sarcopenia in is a key element in the optimization of care in this patient population.Assessment of muscle mass by computed tomography is considered the standard of care for the diagnosis of sarcopenia,but exposure to radiation and high costs limit its application in this setting,especially for repeated assessments.We believe that ultrasound,a cheap and harmless technique also used for HCC screening in cirrhotic patients,could have an expanding role in the diagnosis and follow-up of sarcopenia in these patients. 展开更多
关键词 SARCOPENIA ultrasound CIRRHOSIS Hepatocellular carcinoma Computed tomography
下载PDF
Prognostic value of ultrasound in early arterial complications post liver transplant 被引量:1
10
作者 Ning-Bo Zhao Yi Chen +2 位作者 Rui Xia Jian-Bo Tang Dong Zhao 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第1期13-20,共8页
Liver transplantation is the primary therapeutic intervention for end-stage liver disease.However,vascular complications,particularly those involving the hepatic artery,pose significant risks to patients.The clinical ... Liver transplantation is the primary therapeutic intervention for end-stage liver disease.However,vascular complications,particularly those involving the hepatic artery,pose significant risks to patients.The clinical manifestations associated with early arterial complications following liver transplantation are often non-specific.Without timely intervention,these complications can result in graft fai-lure or patient mortality.Therefore,early diagnosis and the formulation of an op-timal treatment plan are imperative.Ultrasound examination remains the pre-dominant imaging modality for detecting complications post liver transplan-tation.This article comprehensively reviews common causes and clinical present-ations of early hepatic artery complications in the post-transplantation period and delineates abnormal sonographic findings for accurate diagnosis of these con-ditions.Overall,ultrasound offers the advantages of convenience,safety,effect-iveness,and non-invasiveness.It enables real-time,dynamic,and precise evalua-tion,making it the preferred diagnostic method for post-liver transplantation assessments.INTRODUCTION Liver transplantation stands as the primary therapeutic approach for end-stage liver disease.Continuous advancements in surgical techniques and the application of novel immunosuppressive agents contribute to ongoing improvements in the success rate and overall survival in patients undergoing liver transplantation procedures.Despite these advan-cements,vascular complications,particularly those involving the hepatic artery,pose significant risks to patients.During the early stages following liver transplantation(within the first 30 d),proper hepatic artery function is crucial for hepatic arterial blood flow.During later stages,collateral circulation,including arteries such as the phrenic artery,right gastric artery,and gastroduodenal artery,becomes important for maintaining hepatic blood supply.It is now understood that the establishment of effective collateral circulation is pivotal for determining the prognosis of hepatic artery complic-ations.The clinical manifestations of these complications are closely linked to factors such as timing,severity,and the specific type of onset.Insufficient hepatic arterial blood flow can lead to abnormal liver function,hepatic infarction,and the formation of hepatic abscesses.Additionally,since the hepatic artery is the sole blood supply to the biliary tract,hepatic artery-related ischemia may result in biliary stricture,obstruction,and the formation of bile ducts.Ultrasound examination remains the primary imaging modality for diagnosing complications post liver transplantation.This article comprehensively reviews common causes and clinical presentations of early hepatic artery complications in the post-transplantation period and outlines abnormal sonographic findings for accurately diagnosing these conditions.NORMAL HEPATIC ARTERY During the intraoperative phase,an ultrasound examination is typically conducted to evaluate the hepatic artery anas-tomosis.The normal internal diameter of the hepatic artery typically ranges from 2 to 5 mm.Two strong echo points are typically identified near the anastomosis.To assess blood flow dynamics,peak systolic velocity,end-diastolic velocity,and resistance index are measured at the donor and recipient sides of the anastomosis following angle correction.Anastomotic stenosis presence and severity can be evaluated by comparing the velocity at the anastomotic site with that at the recipient side.Postoperatively,direct visualization of the anastomosis site through gray ultrasound scans is often challenging.The surgical approach has a significant impact on the proper hepatic artery’s position,resulting in a lower overall success rate of continuous visualization.Color Doppler ultrasound is primarily employed to trace the artery’s path,and spectral measurements are taken at the brightest position of the Color Doppler blood flow signal,primarily used to identify the presence of high-speed turbulence.Hepatic artery spectrum examination plays a crucial role,as a favorable arterial spectral waveform and appropriate hepatic artery flow velocity typically indicate a successful anastomosis,even in cases where the hepatic artery anastomosis cannot be directly visualized by ultrasound.The hepatic artery runs alongside the portal vein,often selected as a reference due to its larger inner diameter.A normal hepatic artery spectrum displays a regular pulsation pattern with a rapid rise in systole and a slow decline in diastole.Parameters for assessing hepatic artery resistance include a resistance index between 0.5 to 0.8 and an artery systolic acceleration of less than 80 ms.Instantaneous increases in the resistance index(RI>0.8)often occur within 2 d after surgery,followed by a subsequent return to normal hepatic arterial parameters.It has been established that the maximum blood flow velocity during systole in the hepatic artery should not exceed 200 cm/s[1]. 展开更多
关键词 Liver transplantation Vascular complication Arterial complication ultrasound
下载PDF
Effect of sequential nursing care combined with communication intervention on visual recovery and pain after cataract ultrasound emulsification 被引量:1
11
作者 Jing-Cao Wang Qing Zhang +2 位作者 Man-Rong Yu Yun-Xia Yang Hui-Min Jiang 《World Journal of Clinical Cases》 SCIE 2024年第27期6087-6093,共7页
BACKGROUND Cataracts are a common ophthalmic disease and postoperative vision recovery is crucial to patient quality of life.Rational and efficient care models play an impor-tant role in promoting vision recovery.AIM ... BACKGROUND Cataracts are a common ophthalmic disease and postoperative vision recovery is crucial to patient quality of life.Rational and efficient care models play an impor-tant role in promoting vision recovery.AIM To evaluate the clinical effectiveness of procedural nursing care combined with communication intervention in vision recovery after cataract ultrasound emulsi-fication.METHODS A randomized controlled study was conducted on 100 patients with cataracts who underwent ultrasound emulsification surgery.They were randomly assigned to an experimental group or a control group.The experimental group received procedural nursing combined with Connect,Introduce,Communicate,Ask,Respond,Exit(CICARE)communication intervention,whereas the control group received conventional nursing.The effectiveness of the nursing model was assessed by comparing differences in vision recovery,pain scores,and mental health status between the two groups.RESULTS It was found that over time the visual acuity of patients in both groups gradually recovered and patients in the experimental group had lower pain scores and superior mental health status than the control group(P<0.05).CONCLUSION Procedural nursing combined with CICARE communication intervention has positive effects on vision recovery in patients after cataract ultrasound emulsification. 展开更多
关键词 Sequential nursing Communication intervention CICARE Cataract ultrasound emulsification Vision restoration
下载PDF
Novel approach of ultrasound-guided lateral recess block for a patient with lateral recess stenosis: A case report 被引量:1
12
作者 Jiao Yang Xin-Ling Li Qing-Bing Li 《World Journal of Clinical Cases》 SCIE 2024年第5期1010-1017,共8页
BACKGROUND Ultrasound guide technology,which can provide real-time visualization of the needle tip and tissues and avoid many adverse events,is widely used in mini-mally invasive therapy.However,the studies on ultraso... BACKGROUND Ultrasound guide technology,which can provide real-time visualization of the needle tip and tissues and avoid many adverse events,is widely used in mini-mally invasive therapy.However,the studies on ultrasound-guided Lateral recess block(LRB)are limited,this is probably because there is no recognized standard method for ultrasound scanning.This study aimed to evaluate the effect of ultrasound-guided LRB in patients with lateral recess stenosis(LRS).CASE SUMMARY A 65-year-old patient complained of low back pain accompanied occasionally by pain and numbness in the left lower limb.Physical examination showed ten-derness on the spinous process and paraspinal muscles from L1 to S1,extensor hallucis longus and tibialis anterior weakness(muscle strength:4-),and a positive straight leg raising test in the left lower limb(60°).Magnetic resonance imaging showed L4–L5 disc degeneration with left LRS and nerve root entrapment.Subsequently,the patient was diagnosed with LRS.This patient was treated with a novel ultrasound-guided LRB approach.The patient’s symptoms significantly improved without any complications at 1 wk postoperatively and at the 3-month follow-up.CONCLUSION This is the first report on the LRS treatment with ultrasound-guided LRB from the contralateral spinous process along the inner side of the articular process by out-plane technique.Further studies are expected to investigate the efficacy and safety of ultrasound-guided LRB for patients with LRS. 展开更多
关键词 Lateral recess stenosis ultrasound Lateral recess block Real-time visualization Low back pain Case report
下载PDF
Use of endoscopic ultrasound-guided gallbladder drainage as a rescue approach in cases of unsuccessful biliary drainage 被引量:1
13
作者 Alessandro Fugazza Kareem Khalaf +10 位作者 Katarzyna M Pawlak Marco Spadaccini Matteo Colombo Marta Andreozzi Marco Giacchetto Silvia Carrara Chiara Ferrari Cecilia Binda Benedetto Mangiavillano Andrea Anderloni Alessandro Repici 《World Journal of Gastroenterology》 SCIE CAS 2024年第1期70-78,共9页
This narrative review provides an overview of the utilization of endoscopic ultrasound-guided gallbladder drainage(EUS-GBD)as a salvage approach in cases of unsuccessful conventional management.EUS-GBD is a minimally ... This narrative review provides an overview of the utilization of endoscopic ultrasound-guided gallbladder drainage(EUS-GBD)as a salvage approach in cases of unsuccessful conventional management.EUS-GBD is a minimally invasive and effective technique for drainage in patients with acute cholecystitis with high risk of surgery.The procedure has demonstrated impressive technical and clinical success rates with low rates of adverse events,making it a safe and effective option for appropriate candidates.Furthermore,EUS-GBD can also serve as a rescue option for patients who have failed endoscopic retrograde cholangiopancreatography or EUS biliary drainage for relief of jaundice in malignant biliary stricture.However,patient selection is critical for the success of EUS-GBD,and proper patient selection and risk assessment are important to ensure the safety and efficacy of the procedure.As the field continues to evolve and mature,ongoing research will further refine our understanding of the benefits and limitations of EUS-GBD,ultimately leading to improved outcomes for patients. 展开更多
关键词 Endoscopic ultrasound-guided gallbladder drainage Gallbladder drainage Acute cholecystitis Malignant obstruction Interventional endoscopic ultrasound Lumen-apposing metal stents
下载PDF
Contrast-enhanced guided endoscopic ultrasound procedures 被引量:1
14
作者 Marcel Ioan Gheorghiu Andrada Seicean +3 位作者 Cristina Pojoga Claudia Hagiu Radu Seicean Zeno Sparchez 《World Journal of Gastroenterology》 SCIE CAS 2024年第17期2311-2320,共10页
Contrast-enhanced endoscopic ultrasound(CH-EUS)can overcome the limi-tations of endoscopic ultrasound-guided acquisition by identifying microvessels inside inhomogeneous tumours and improving the characterization of t... Contrast-enhanced endoscopic ultrasound(CH-EUS)can overcome the limi-tations of endoscopic ultrasound-guided acquisition by identifying microvessels inside inhomogeneous tumours and improving the characterization of these tumours.Despite the initial enthusiasm that oriented needle sampling under CH-EUS guidance could provide better diagnostic yield in pancreatic solid lesions,further studies did not confirm the supplementary values in cases of tissue acquisition guided by CH-EUS.This review details the knowledge based on the available data on contrast-guided procedures.The indications for CH-EUS tissue acquisition include isoechoic EUS lesions with poor visible delineation where CH-EUS can differentiate the lesion vascularisation from the surrounding parenchyma and also the mural nodules within biliopancreatic cystic lesions,which occur in select cases.Additionally,the roles of CH-EUS-guided therapy in patients whose pancreatic fluid collections or bile ducts that have an echogenic content have indications for drainage,and patients who have nonvisualized vessels that need to be highlighted via Doppler EUS are presented.Another indication is represented if there is a need for an immediate assessment of the post-radiofrequency ablation of pancreatic neuroendocrine tumours,in which case CH-EUS can be used to reveal the incomplete tumour destruction. 展开更多
关键词 ENDOSONOGRAPHY Contrast-enhanced endoscopic ultrasound Tissue acquisition Fine needle aspiration Fine needle biopsy Drainage Pancreatic fluid collections BIOPSY PANCREAS
下载PDF
Role of Intra-Operative Nerve Monitoring in Thyroidectomies: An Institutional Review
15
作者 Naren N. Venkatesan Sharon H. Gnagi Michael P. Underbrink 《International Journal of Otolaryngology and Head & Neck Surgery》 2014年第4期154-160,共7页
Injury to the Recurrent Laryngeal Nerve (RLN) is a worrisome complication of a thyroidectomy. Intra-operative nerve monitoring (IONM) of the RLN has gained prevalence as an aid to prevent injury. We reviewed our serie... Injury to the Recurrent Laryngeal Nerve (RLN) is a worrisome complication of a thyroidectomy. Intra-operative nerve monitoring (IONM) of the RLN has gained prevalence as an aid to prevent injury. We reviewed our series and other studies in literature for insight. A chart review was carried out to identify all patients who underwent a thyroidectomy between 2005 and 2010. IONM was implemented by the Otolaryngology service in 2007. All identified patients were separated into three groups: 1) Otolaryngology service with IONM, 2) Otolaryngology service without IONM, and 3) General Surgery service without IONM. Several factors were noted, including age, sex, thyroid disease, extent of thyroidectomy, and RLN injury along with recovery. 230 patients underwent thyroidectomy from 2005-2010. 60 patients were isolated in the IONM-Otolaryngology group with 3 patients suffering injury. 109 patients underwent a thyroidectomy by the Otolaryngology service without IONM with 8 patients suffering nerve damage. In the third group, 61 patients underwent a thyroidectomy by General Surgery without IONM with 4 patients suffering damage. Of the thyroid pathology, 10 patients had Multinodular Goiter while 4 had Papillary Cancer and 1 had a Follicular Adenoma. The most severe complication of a thyroidectomy is RLN injury. In order to further decrease the risk of RLN injury, IONM has been employed. From our review and other studies, there does not appear to be a significant difference in rates of RLN injury with or without use of nerve monitoring. An interesting note is the increased prevalence of nerve injuries in Multinodular Goiter—a finding that merits further study to evaluate the role of IONM. 展开更多
关键词 Recurrent LARYNGEAL NERVE Injruy Vocal Cord PARALYSIS THYROIDECTOMY intra-operative NERVE MONITORING
下载PDF
Predictive value of diaphragm ultrasound for mechanical ventilation outcome in patients with acute exacerbation of chronic obstructive pulmonary disease 被引量:1
16
作者 Lei-Lei Qu Wen-Ping Zhao +1 位作者 Ji-Ping Li Wei Zhang 《World Journal of Clinical Cases》 SCIE 2024年第26期5893-5900,共8页
BACKGROUND Acute exacerbation of chronic obstructive pulmonary disease(AECOPD)is often combined with respiratory failure,which increases the patient's morbidity and mortality.Diaphragm ultrasound(DUS)has developed... BACKGROUND Acute exacerbation of chronic obstructive pulmonary disease(AECOPD)is often combined with respiratory failure,which increases the patient's morbidity and mortality.Diaphragm ultrasound(DUS)has developed rapidly in the field of critical care in recent years.Studies with DUS monitoring diaphragm-related rapid shallow breathing index have demonstrated important results in guiding intensive care unit patients out of the ventilator.Early prediction of the indications for withdrawal of non-invasive ventilator and early evaluation of patients to avoid or reduce disease progression are very important.AIM To explore the predictive value of DUS indexes for non-invasive ventilation outcome in patients with AECOPD.METHODS Ninety-four patients with AECOPD who received mechanical ventilation in our hospital from January 2022 to December 2023 were retrospectively analyzed,and they were divided into a successful ventilation group(68 cases)and a failed ventilation group(26 cases)according to the outcome of ventilation.The clinical data of patients with successful and failed noninvasive ventilation were compared,and the independent predictors of noninvasive ventilation outcomes in AECOPD patients were identified by multivariate logistic regression analysis.RESULTS There were no significant differences in gender,age,body mass index,complications,systolic pressure,heart rate,mean arterial pressure,respiratory rate,oxygen saturation,partial pressure of oxygen,oxygenation index,or time of inspiration between patients with successful and failed mechanical ventilation(P>0.05).The patients with successful noninvasive ventilation had shorter hospital stays and lower partial pressure of carbon dioxide(PaCO_(2))than those with failed treatment,while potential of hydrogen(pH),diaphragm thickening fraction(DTF),diaphragm activity,and diaphragm movement time were significantly higher than those with failed treatment(P<0.05).pH[odds ratio(OR)=0.005,P<0.05],PaCO_(2)(OR=0.430,P<0.05),and DTF(OR=0.570,P<0.05)were identified to be independent factors influencing the outcome of mechanical ventilation in AECOPD patients.CONCLUSION The DUS index DTF can better predict the outcome of non-invasive ventilation in AECOPD patients. 展开更多
关键词 Diaphragm ultrasound Mechanical ventilation Acute exacerbation of chronic obstructive pulmonary disease Predictive value Diaphragm thickening fraction Diaphragm activity
下载PDF
Low-intensity pulsed ultrasound reduces alveolar bone resorption during orthodontic treatment via Lamin A/C-Yes-associated protein axis in stem cells 被引量:1
17
作者 Tong Wu Fu Zheng +7 位作者 Hong-Yi Tang Hua-Zhi Li Xin-Yu Cui Shuai Ding Duo Liu Cui-Ying Li Jiu-Hui Jiang Rui-Li Yang 《World Journal of Stem Cells》 SCIE 2024年第3期267-286,共20页
BACKGROUND The bone remodeling during orthodontic treatment for malocclusion often requires a long duration of around two to three years,which also may lead to some complications such as alveolar bone resorption or to... BACKGROUND The bone remodeling during orthodontic treatment for malocclusion often requires a long duration of around two to three years,which also may lead to some complications such as alveolar bone resorption or tooth root resorption.Low-intensity pulsed ultrasound(LIPUS),a noninvasive physical therapy,has been shown to promote bone fracture healing.It is also reported that LIPUS could reduce the duration of orthodontic treatment;however,how LIPUS regulates the bone metabolism during the orthodontic treatment process is still unclear.AIM To investigate the effects of LIPUS on bone remodeling in an orthodontic tooth movement(OTM)model and explore the underlying mechanisms.METHODS A rat model of OTM was established,and alveolar bone remodeling and tooth movement rate were evaluated via micro-computed tomography and staining of tissue sections.In vitro,human bone marrow mesenchymal stem cells(hBMSCs)were isolated to detect their osteogenic differentiation potential under compression and LIPUS stimulation by quantitative reverse transcription-polymerase chain reaction,Western blot,alkaline phosphatase(ALP)staining,and Alizarin red staining.The expression of Yes-associated protein(YAP1),the actin cytoskeleton,and the Lamin A/C nucleoskeleton were detected with or without YAP1 small interfering RNA(siRNA)application via immunofluorescence.RESULTS The force treatment inhibited the osteogenic differentiation potential of hBMSCs;moreover,the expression of osteogenesis markers,such as type 1 collagen(COL1),runt-related transcription factor 2,ALP,and osteocalcin(OCN),decreased.LIPUS could rescue the osteogenic differentiation of hBMSCs with increased expression of osteogenic marker inhibited by force.Mechanically,the expression of LaminA/C,F-actin,and YAP1 was downregulated after force treatment,which could be rescued by LIPUS.Moreover,the osteogenic differentiation of hBMSCs increased by LIPUS could be attenuated by YAP siRNA treatment.Consistently,LIPUS increased alveolar bone density and decreased vertical bone absorption in vivo.The decreased expression of COL1,OCN,and YAP1 on the compression side of the alveolar bone was partially rescued by LIPUS.CONCLUSION LIPUS can accelerate tooth movement and reduce alveolar bone resorption by modulating the cytoskeleton-Lamin A/C-YAP axis,which may be a promising strategy to reduce the orthodontic treatment process. 展开更多
关键词 Low-intensity pulsed ultrasound Bone resorption OSTEOGENESIS Cytoskeleton-Lamin A/C-Yes-associated protein axis Bone marrow mesenchymal stem cells Orthodontic tooth movement
下载PDF
Evaluation of hand infections in the emergency department using point-of-care ultrasound
18
作者 David Ahmad Haidar David Mintz +2 位作者 Brandon M Wubben Omar Rizvi Srikar Adhikari 《World Journal of Emergency Medicine》 SCIE CAS CSCD 2024年第4期283-288,共6页
BACKGROUND:We aimed to evaluate the utility of point-of-care ultrasound(POCUS)in the assessment of hand infections that present to the emergency department(ED)and its impact on medical decision making and patient mana... BACKGROUND:We aimed to evaluate the utility of point-of-care ultrasound(POCUS)in the assessment of hand infections that present to the emergency department(ED)and its impact on medical decision making and patient management.METHODS:We conducted a retrospective review of patients who presented to two urban academic EDs with clinical presentations concerning for skin and soft tissue infections(SSTI)of the hand between December 2015 and December 2021.Two trained POCUS fellowship physicians reviewed an ED POCUS database for POCUS examinations of the hand.We then reviewed patients’electronic health records(EHR)for demographic characteristics,history,physical examination findings,ED course,additional imaging studies,consultations,impact of POCUS on patient care and final disposition.RESULTS:We included a total of 50 cases(28 male,22 female)in the final analysis.The most common presenting symptoms and exam findings were pain(100%),swelling(90%),and erythema(74%).The most common sonographic findings were edema(76%),soft tissue swelling(78%),and fluid surrounding the tendon(57%).POCUS was used in medical decision making 68%of the time(n=34),with the use of POCUS leading to changes in management 38%of the time(n=19).POCUS use led to early antibiotic use(11/19),early consultation(10/19),and led to the performance of a required procedure(8/19).The POCUS diagnosis was consistent with the discharge diagnosis of flexor tenosynovitis 8/12 times,abscess 12/16 times,and cellulitis 14/20 times.CONCLUSION:POCUS is beneficial for evaluating of hand infections that present to the ED and can be used as an important part of medical decision making to expedite patient care. 展开更多
关键词 ultrasound Point-of-care ultrasound CELLULITIS ABSCESS Flexor tenosynovitis
下载PDF
Pictorial review of hepatic echinococcosis:Ultrasound imaging and differential diagnosis
19
作者 Yi Tao Yi-Fei Wang +4 位作者 Jun Wang Shuang Long Barnabas C Seyler Xiao-Fei Zhong Qiang Lu 《World Journal of Gastroenterology》 SCIE CAS 2024年第37期4115-4131,共17页
Echinococcosis is a zoonotic disease caused by parasites belonging to the genus Echinococcus that primarily affect the liver.The western plateau and pastoral areas of China are high-risk regions for hepatic cystic ech... Echinococcosis is a zoonotic disease caused by parasites belonging to the genus Echinococcus that primarily affect the liver.The western plateau and pastoral areas of China are high-risk regions for hepatic cystic echinococcosis and hepatic alveolar echinococcosis(HAE).The high late mortality rate associated with HAE underscores the critical need for early diagnosis to improve cure rates and mitigate the disease burden in endemic areas.Currently,the World Health Orga-nization recommends ultrasonography as the preferred initial screening method for hepatic echinococcosis.However,distinguishing between specific types of lesions,such as those of hepatic cystic echinococcosis and HAE,and other focal liver lesions is challenging.To address this issue,contrast-enhanced ultrasound is recommended as a tool to differentiate solid and cysto-solid hepatic echino-coccosis from other focal liver lesions,significantly enhancing diagnostic accuracy.In this comprehensive review,we discuss the progression of hepatic echinococcosis and detail the imaging features of various types of echinococcosis using conventional,contrast-enhanced,and intraoperative ultrasound techniques.Our objective is to provide robust imaging evidence and guidance for early diagnosis,clinical decision making,and postoperative follow-up in regions with high disease prevalence. 展开更多
关键词 ECHINOCOCCOSIS Zoonotic disease ultrasound Contrast-enhanced ultrasound DIAGNOSIS
下载PDF
Is endoscopic ultrasound a promising technique in the diagnosis and treatment of liver diseases?
20
作者 Enver Zerem Željko Puljiz +3 位作者 Boris Zdilar Suad Kunosic Admir Kurtcehajic Omar Zerem 《World Journal of Gastroenterology》 SCIE CAS 2024年第22期2920-2922,共3页
Percutaneous ultrasound has been a longstanding method in the diagnostics and interventional procedures of liver diseases.In some countries,its use is restricted to radiologists,limiting access for other clinicians,su... Percutaneous ultrasound has been a longstanding method in the diagnostics and interventional procedures of liver diseases.In some countries,its use is restricted to radiologists,limiting access for other clinicians,such as gastroenterologists.Endoscopic ultrasound,as a novel technique,plays a crucial role in diagnosis and treatment of digestive diseases.However,its use is sometimes recommended for conditions where no clear advantage over percutaneous ultrasound exists,leaving the impression that clinicians sometimes resort to an endoscopic approach due to the unavailability of percutaneous options. 展开更多
关键词 Endoscopic ultrasound Percutaneous ultrasound Liver biopsy Fine needle aspiration Focal liver lesion Liver abscess drainage