Background:To compare the safety and efficacy of LVIS stent-assisted coiling with those of laser-cut stent-assisted coiling for the treatment of acutely ruptured wide-necked intracranial aneurysms.Methods:Patients wit...Background:To compare the safety and efficacy of LVIS stent-assisted coiling with those of laser-cut stent-assisted coiling for the treatment of acutely ruptured wide-necked intracranial aneurysms.Methods:Patients with acutely ruptured wide-necked intracranial aneurysms treated with LVIS stent-assisted coiling(LVIS stent group)and laser-cut stent-assisted coiling(laser-cut stent group)were retrospectively reviewed from January 2014 to December 2017.Propensity score matching was used to adjust for potential differences in age,sex,aneurysm location,aneurysm size,neck width,Hunt-Hess grade,and modified Fisher grade.Perioperative procedure-related complications and clinical and angiographic follow-up outcomes were compared.Univariate and multivariate analyses were performed to determine the associations between procedure-related complications and potential risk factors.Results:A total of 142 patients who underwent LVIS stent-assisted coiling and 93 patients who underwent laser-cut stent-assisted coiling were enrolled after 1:2 propensity score matching.The angiographic follow-up outcomes showed that the LVIS stent group had a slightly higher complete occlusion rate and lower recurrence rate than the laser-cut stent group(92.7%vs 80.6%;3.7%vs 9.7%,P=0.078).The clinical outcomes at discharge and follow-up between the two groups demonstrated no significant differences(P=0.495 and P=0.875,respectively).The rates of intraprocedural thrombosis,postprocedural thrombosis,postoperative early rebleeding,and procedure-related death were 0.7%(1/142),1.4%(2/142),2.8%(4/142),and 2.1%(3/142)in the LVIS stent group,respectively,and 4.3%(4/93),2.2%(2/93),1.1%(1/93),and 3.2%(3/93)in the laser-cut stent group,respectively(P=0.082,0.649,0.651,and 0.683).Nevertheless,the rates of overall procedure-related complications and intraprocedural rupture in the LVIS stent group were significantly lower than those in the laser-cut stent group(5.6%vs 14.0%,P=0.028;0.7%vs 6.5%,P=0.016).Multivariate analysis showed that laser-cut stent-assisted coiling was an independent predictor for overall procedurerelated complications(OR=2.727,P=0.037);a history of diabetes(OR=7.275,P=0.027)and other cerebrovascular diseases(OR=8.083,P=0.022)were independent predictors for ischemic complications,whereas none of the factors were predictors for hemorrhagic complications.Conclusions:Compared with laser-cut stent-assisted coiling,LVIS stent-assisted coiling for the treatment of acutely ruptured wide-necked intracranial aneurysms could reduce the rates of overall procedure-related complications and intraprocedural rupture.展开更多
Background:The purpose of this analysis is to evaluate the current evidence with regard to the effectiveness and safety between coiling and clipping in patients with ruptured intracranial aneurysms(RIAs).Methods:We pe...Background:The purpose of this analysis is to evaluate the current evidence with regard to the effectiveness and safety between coiling and clipping in patients with ruptured intracranial aneurysms(RIAs).Methods:We performed a meta-analysis that compared clipping with coiling between July 2000 and September 2021.PubMed,EMBASE,and the Cochrane Library were searched for related articles systematically.And the treatment efficacy and postoperative complications were analyzed.Results:We identified three randomized controlled trials and thirty-seven observational studies involving 60,875 patients with ruptured cerebral aneurysms.The summary results showed that coiling was related a better quality of life(mRS0-2;OR=1.327;CI=1.093-1.612;p<0.05),a higher risk of mortality(OR=1.116;CI=1.054-1.180;p<0.05),higher rate of rebleeding(RR=1.410;CI=1.092-1.822;p<0.05),lower incidence of vasospasm(OR=0.787;CI=0.649-0.954;p<0.05),higher risk of hydrocephalous(RR=1.143;CI=1.043-1.252;p<0.05),lower risk of cerebral infarction(RR=0.669;CI=0.596-0.751;p<0.05),lower risk of neuro deficits(RR=0.720;CI=0.582-0.892;p<0.05),and a lower rate of complete occlusion(OR=0.495;CI=0.280-0.876;p<0.05).Conclusion:Coiling was significantly associated with a better life quality(mRS0-2),a lower incidence of postoperative complications,and a higher rate of mortality,rebleeding,hydrocephalous,and a lower rate of complete occlusion than clipping.展开更多
基金This work was supported by the National Key Research and Development Program of China(grant no.: 2016YFC1300703)National Natural Science Foundation of China(grant no.: 81701136, 81571126).
文摘Background:To compare the safety and efficacy of LVIS stent-assisted coiling with those of laser-cut stent-assisted coiling for the treatment of acutely ruptured wide-necked intracranial aneurysms.Methods:Patients with acutely ruptured wide-necked intracranial aneurysms treated with LVIS stent-assisted coiling(LVIS stent group)and laser-cut stent-assisted coiling(laser-cut stent group)were retrospectively reviewed from January 2014 to December 2017.Propensity score matching was used to adjust for potential differences in age,sex,aneurysm location,aneurysm size,neck width,Hunt-Hess grade,and modified Fisher grade.Perioperative procedure-related complications and clinical and angiographic follow-up outcomes were compared.Univariate and multivariate analyses were performed to determine the associations between procedure-related complications and potential risk factors.Results:A total of 142 patients who underwent LVIS stent-assisted coiling and 93 patients who underwent laser-cut stent-assisted coiling were enrolled after 1:2 propensity score matching.The angiographic follow-up outcomes showed that the LVIS stent group had a slightly higher complete occlusion rate and lower recurrence rate than the laser-cut stent group(92.7%vs 80.6%;3.7%vs 9.7%,P=0.078).The clinical outcomes at discharge and follow-up between the two groups demonstrated no significant differences(P=0.495 and P=0.875,respectively).The rates of intraprocedural thrombosis,postprocedural thrombosis,postoperative early rebleeding,and procedure-related death were 0.7%(1/142),1.4%(2/142),2.8%(4/142),and 2.1%(3/142)in the LVIS stent group,respectively,and 4.3%(4/93),2.2%(2/93),1.1%(1/93),and 3.2%(3/93)in the laser-cut stent group,respectively(P=0.082,0.649,0.651,and 0.683).Nevertheless,the rates of overall procedure-related complications and intraprocedural rupture in the LVIS stent group were significantly lower than those in the laser-cut stent group(5.6%vs 14.0%,P=0.028;0.7%vs 6.5%,P=0.016).Multivariate analysis showed that laser-cut stent-assisted coiling was an independent predictor for overall procedurerelated complications(OR=2.727,P=0.037);a history of diabetes(OR=7.275,P=0.027)and other cerebrovascular diseases(OR=8.083,P=0.022)were independent predictors for ischemic complications,whereas none of the factors were predictors for hemorrhagic complications.Conclusions:Compared with laser-cut stent-assisted coiling,LVIS stent-assisted coiling for the treatment of acutely ruptured wide-necked intracranial aneurysms could reduce the rates of overall procedure-related complications and intraprocedural rupture.
文摘Background:The purpose of this analysis is to evaluate the current evidence with regard to the effectiveness and safety between coiling and clipping in patients with ruptured intracranial aneurysms(RIAs).Methods:We performed a meta-analysis that compared clipping with coiling between July 2000 and September 2021.PubMed,EMBASE,and the Cochrane Library were searched for related articles systematically.And the treatment efficacy and postoperative complications were analyzed.Results:We identified three randomized controlled trials and thirty-seven observational studies involving 60,875 patients with ruptured cerebral aneurysms.The summary results showed that coiling was related a better quality of life(mRS0-2;OR=1.327;CI=1.093-1.612;p<0.05),a higher risk of mortality(OR=1.116;CI=1.054-1.180;p<0.05),higher rate of rebleeding(RR=1.410;CI=1.092-1.822;p<0.05),lower incidence of vasospasm(OR=0.787;CI=0.649-0.954;p<0.05),higher risk of hydrocephalous(RR=1.143;CI=1.043-1.252;p<0.05),lower risk of cerebral infarction(RR=0.669;CI=0.596-0.751;p<0.05),lower risk of neuro deficits(RR=0.720;CI=0.582-0.892;p<0.05),and a lower rate of complete occlusion(OR=0.495;CI=0.280-0.876;p<0.05).Conclusion:Coiling was significantly associated with a better life quality(mRS0-2),a lower incidence of postoperative complications,and a higher rate of mortality,rebleeding,hydrocephalous,and a lower rate of complete occlusion than clipping.