AIM:To evaluate the visual and refractive outcomes in cases after sutured scleral fixation of existing subluxated or dislocated acrylic one-piece intraocular lenses(IOLs).METHODS:This study retrospectively enrolled a ...AIM:To evaluate the visual and refractive outcomes in cases after sutured scleral fixation of existing subluxated or dislocated acrylic one-piece intraocular lenses(IOLs).METHODS:This study retrospectively enrolled a consecutive series of patients who underwent a surgery of sutured existing subluxated or dislocated IOLs from October 2018 to June 2020.All patients underwent comprehensive preoperative and postoperative ophthalmologic examination,and data were collected including age,sex,surgical indications,best-corrected visual acuity,refractive error,intraocular pressure.Presence of intraoperative and postoperative surgical complications was documented.RESULTS:A total of 20 consecutive cases were enrolled for analysis with mean final follow-up period 9.8±5.3mo.Visual acuity improved from a mean of 0.35(0.46±0.32 logMAR)preoperatively to 0.61(0.21±0.18 logMAR)at the 3-month follow-up(P=0.002).The mean amount of preoperative keratometric astigmatism and total postoperative refractive astigmatism was-1.24±0.80 diopters(D)and-1.42±0.97 D,respectively.There was no statistically significant difference between preoperative and postoperative astigmatism(P=0.156).The mean IOL-induced astigmatism was-0.23±0.53 D.The mean spherical equivalent at the 3-month follow-up was-0.1±0.94 D.No major complications were noted during the follow-up period.CONCLUSION:Surgical techniques using sutured scleral fixation of existing subluxated or dislocated acrylic one-piece IOLs result in favorable visual and refractive outcomes without major complications.展开更多
●AIM:To evaluate the effect of background diseases and number of previous intravitreal aflibercept injections(IVAIs)on immediate intraocular pressure(IOP)increase and vitreous reflux(VR)rate and to evaluate the corre...●AIM:To evaluate the effect of background diseases and number of previous intravitreal aflibercept injections(IVAIs)on immediate intraocular pressure(IOP)increase and vitreous reflux(VR)rate and to evaluate the correlation of both age and axial length with immediate IOP increase and VR rate.●METHODS:This study included 105 patients with cystoid macular edema secondary to retinal vein occlusion,35 patients with diabetic macular edema,69 patients with neovascular age-related macular degeneration(nAMD),and 12 patients with myopic choroidal neovascularization,which underwent first-time IVAI.The correlation of immediate IOP increase and VR rates with the four background diseases was investigated.Moreover,the correlation of age with immediate IOP increase and VR rate as well as correlation of axial length with immediate IOP increase and VR rate were evaluated.Further,54 patients with nAMD were treated with IVAI>10 times(multiple IVAIs).Moreover,the correlation of immediate IOP increase and VR rates with first-time and multiple IVAIs in nAMD was determined.●RESULTS:The immediate IOP increase(P=0.16)and VR rates(P=0.50)were almost similar among the four background diseases.The immediate postinjection IOP and age,VR rate and age,immediate postinjection IOP and axial length,or VR rate and axial length were not correlated in the four background diseases.The immediate IOP increase(P=0.66)and VR rates(P=0.28)did not significantly differ between first-time and multiple IVAIs in nAMD.●CONCLUSION:Background diseases and number of previous IVAIs have no effect on immediate IOP increase and VR rate.Further,age and axial length have no correlation on immediate IOP increase and VR rate.展开更多
Intraocular pressure elevation can induce retinal ganglion cell death and is a clinically reversible risk factor for glaucoma,the leading cause of irreversible blindness.We previously demonstrated that casein kinase-2...Intraocular pressure elevation can induce retinal ganglion cell death and is a clinically reversible risk factor for glaucoma,the leading cause of irreversible blindness.We previously demonstrated that casein kinase-2 inhibition can promote retinal ganglion cell survival and axonal regeneration in rats after optic nerve injury.To investigate the underlying mechanism,in the current study we increased the intraocular pressure of adult rats to 75 mmHg for 2 hours and then administered a casein kinase-2 inhibitor(4,5,6,7-tetrabromo-2-azabenzimidazole or 2-dimethylamino-4,5,6,7-tetrabromo-1H-benzimidazole)by intravitreal injection.We found that intravitreal injection of 4,5,6,7-tetrabromo-2-azabenzimidazole or 2-dimethylamino-4,5,6,7-tetrabromo-1H-benzimidazole promoted retinal ganglion cell survival and reduced the number of infiltrating macrophages.Transcriptomic analysis showed that the mitogen activated protein kinase signaling pathway was involved in the response to intraocular pressure elevation but was not modulated by the casein kinase-2 inhibitors.Furthermore,casein kinase-2 inhibition downregulated the expression of genes(Cck,Htrsa,Nef1,Htrlb,Prph,Chat,Slc18a3,Slc5a7,Scn1b,Crybb2,Tsga10ip,and Vstm21)involved in intraocular pressure elevation.Our data indicate that inhibition of casein kinase-2 can enhance retinal ganglion cell survival in rats after acute intraocular pressure elevation via macrophage inactivation.展开更多
The incidence of cataracts is significantly higher in diabetic individuals,particularly in younger age groups,with rates quadrupled in those under 65 and doubled in those over 65 compared to non-diabetics.Cataract sur...The incidence of cataracts is significantly higher in diabetic individuals,particularly in younger age groups,with rates quadrupled in those under 65 and doubled in those over 65 compared to non-diabetics.Cataract surgery in diabetic patients poses many challenges:Poor epithelial healing,decreased corneal sensitivity,increased central corneal thickness,decreased endothelial cell count,variable topography,poor pupillary dilatation,anterior capsular phimosis,posterior capsular opacification(PCO),chances of progression of diabetic retinopathy(DR),zonular weakness,and vitreous prolapse and diabetic macular edema.Selection of an appropriate intraocular lens(IOL)is crucial for visual rehabilitation and monitoring DR.The choice of IOL in diabetic cataract patients is a challenging scenario.Square-edge IOLs are favored for their capacity to mitigate PCO,whereas hydrophilic counterparts may incur calcification in the setting of proliferative DR.The advisability of premium IOLs for achieving spectacle independence warrants judicious evaluation,particularly in the presence of advanced retinopathy.Optimal IOL placement within the capsular bag is advocated to minimize postoperative complications.Rigorous preoperative assessment and informed patient counseling regarding IOL options are indispensable for optimizing surgical outcomes.This review article covers various aspects regarding the choice of IOLs in different case scenarios and complications in the diabetic population.展开更多
AIM:To investigate the influence of ophthalmic viscoelastic devices(OVDs)and different surgical approaches on the intraocular pressure(IOP)before and after creation of the curvilinear circular capsulorhexis(CCC)as a m...AIM:To investigate the influence of ophthalmic viscoelastic devices(OVDs)and different surgical approaches on the intraocular pressure(IOP)before and after creation of the curvilinear circular capsulorhexis(CCC)as a measure for anterior chamber stability during this maneuver.METHODS:Prospective experimental WetLab study carried out on enucleated porcine eyes.IOP was measured before and after CCC with the iCare Rebound tonometer(iCare ic200;iCare Finland Oy,Vantaa,Finland).The OVDs used were a cohesive one[Z-Hyalin,Carl Zeiss Meditec AG,Germany;hyaluronic acid(HA)]and a dispersive[Z-Celcoat,Carl Zeiss Meditec AG,Germany;hydroxy propylmethylcellulosis(HPMC)].The CCC was created using Utrata forceps or 23 g microforceps in different combinations with the OVDs.RESULTS:Using the Utrata forceps the IOP dropped from 63.65±6.44 to 11.25±3.63 mm Hg during the CCC.The use of different OVDs made no difference.Using the 23 g microforceps the IOP dropped from 65.35±8.15 to 36.55±6.09 mm Hg.The difference between IOP drop using either Utrata forceps or 23 g microforceps was highly significant regardless of the OVD used.CONCLUSION:Using the sideport for the creation of the capsulorhexis leads to a lesser drop in IOP during this maneuver compared to the main incision in enucleated porcine eyes.The use of different OVD has no significant influence on IOP drop.展开更多
●AIM:To assess effectivity and safety of trifocal intraocular lenses(IOLs)and capsular tension rings in treating cataract patients with axial high myopia.●METHODS:A prospective nonrandomized controlled clinical tria...●AIM:To assess effectivity and safety of trifocal intraocular lenses(IOLs)and capsular tension rings in treating cataract patients with axial high myopia.●METHODS:A prospective nonrandomized controlled clinical trial was conducted.Totally 98 eyes(74 patients)who underwent femtosecond laser-assisted cataract surgery(FLACS)with trifocal IOLs were enrolled in the study and followed up for 2y after surgery:46 eyes(33 patients)with capsular tension ring implantation in the long axial lengths(AL)group(26<AL<29 mm)and 52 eyes(41 patients)in the normal AL group(22<AL<24.5 mm).Postoperative outcomes about effectivity and safety,including the subjective and objective visual quality,and postoperative complications were assessed.●RESULTS:Uncorrected distance visual acuity at 5 m and uncorrected intermediate visual acuity at 60 and 80 cm in the long AL group were significantly worse than those in the normal AL group at 3mo postoperatively(P<0.05).The differences in reading speed,spectacle independence and potential visual complaints between the two groups were not statistically significant(P>0.05).The dysfunctional lens index and total modulation transfer function(MTF)average height were similar between the two groups.The postoperative internal coma aberrations in the axial high myopia eyes were significantly higher than that in the normal AL group(P<0.05).The total satisfaction score in the long AL group(91.32±2.76)was slightly higher than that in the normal AL group(90.36±3.47),but there was no difference(P=0.136).A statistically negative correlation was found between corrected distance visual acuity(CDVA)and dysfunctional lens index(r=-0.382,P=0.009),and between CDVA and the total MTF average height(r=-0.374,P=0.01).But there was no significant correlation between CDVA and total satisfaction score(r=0.059,P=0.696).Postoperative complications mainly presented as posterior capsular opacity(PCO),retinal detachment and cystoid macular edema.There was no difference in the incidence of fundus disease(6.5%vs 3.8%,P=0.663)or PCO(17.4%vs 7.7%,P=0.217)between the two groups at two years.●CONCLUSION:The utilization of trifocal IOL and capsular tension ring implantation is beneficial for cataract patients with axial high myopia undergoing FLACS.This approach not only ensures excellent subjective feelings and objective visual quality,but also does not increase the incidence of postoperative complications.展开更多
High intraocular pressure causes retinal ganglion cell injury in primary and secondary glaucoma diseases,yet the molecular landscape characteristics of retinal cells under high intraocular pressure remain unknown.Rat ...High intraocular pressure causes retinal ganglion cell injury in primary and secondary glaucoma diseases,yet the molecular landscape characteristics of retinal cells under high intraocular pressure remain unknown.Rat models of acute hypertension ocular pressure were established by injection of cross-linked hyaluronic acid hydrogel(Healaflow■).Single-cell RNA sequencing was then used to describe the cellular composition and molecular profile of the retina following high intraocular pressure.Our results identified a total of 12 cell types,namely retinal pigment epithelial cells,rod-photoreceptor cells,bipolar cells,Müller cells,microglia,cone-photoreceptor cells,retinal ganglion cells,endothelial cells,retinal progenitor cells,oligodendrocytes,pericytes,and fibroblasts.The single-cell RNA sequencing analysis of the retina under acute high intraocular pressure revealed obvious changes in the proportions of various retinal cells,with ganglion cells decreased by 23%.Hematoxylin and eosin staining and TUNEL staining confirmed the damage to retinal ganglion cells under high intraocular pressure.We extracted data from retinal ganglion cells and analyzed the retinal ganglion cell cluster with the most distinct expression.We found upregulation of the B3gat2 gene,which is associated with neuronal migration and adhesion,and downregulation of the Tsc22d gene,which participates in inhibition of inflammation.This study is the first to reveal molecular changes and intercellular interactions in the retina under high intraocular pressure.These data contribute to understanding of the molecular mechanism of retinal injury induced by high intraocular pressure and will benefit the development of novel therapies.展开更多
BACKGROUND The prevalence of diabetes mellitus(DM)in China is high,and the base is broad.Diabetic retinopathy(DR)is a critical condition affecting the life and health of a nation and its economic development.DR is a c...BACKGROUND The prevalence of diabetes mellitus(DM)in China is high,and the base is broad.Diabetic retinopathy(DR)is a critical condition affecting the life and health of a nation and its economic development.DR is a common complication of DM.AIM To investigate the efficacy of laser photocoagulation combined with intravitreal injection of conbercept for treating macular edema.METHODS Overall,130 patients with diabetic macular edema(DME)hospitalized in The Third People’s Hospital of Changzhou from January 2019 to June 2022 were retrospectively included.According to the treatment plan,130 patients with DME were categorized into an observation and a control group,with 65 patients in each group.The control group received laser photocoagulation,and the observation group received laser photocoagulation with intravitreal injection of conbercept.Observe changes in vision,cytokines in the eye and so on.RESULTS The total efficacy rate in the observation group(93.85%)was higher than that in the control group(78.46%)(P<0.05).In both groups,the best corrected visual acuity correction effect improved after treatment,and the observation group was superior to the control group(P<0.05).Retinal thickness and central macular thickness improved after treatment,and the observation group was superior to the control group(P<0.05).The levels of vascular endothelial growth factor,interleukin-6,soluble intercellular adhesion molecule-1,and basic fibroblast growth factor in both groups improved after treatment,and the observation group was superior to the control group(P<0.05).CONCLUSION In patients with macular edema,combining laser photocoagulation and intravitreal injections of conbercept for DME is a more effective and safer strategy to improve vision,and lower intraocular cytokine levels.展开更多
AIM:To describe a novel suture approach for transscleral fixation of C-loop intraocular lenses(IOL)and to compare the surgical outcomes with the four-haptics posterior chamber(PC)-IOL technique.METHODS:We retrospectiv...AIM:To describe a novel suture approach for transscleral fixation of C-loop intraocular lenses(IOL)and to compare the surgical outcomes with the four-haptics posterior chamber(PC)-IOL technique.METHODS:We retrospectively analyzed 16 eyes of 16 patients who underwent transscleral fixation of C-loop PCIOLs using a flapless one-knot suture technique,which were followed up for longer than 17mo.In this technique,the capsulorless IOL was suspended using a single suture for transscleral fixation of four feet.Then we compared its surgical outcomes and complications with the four-haptics PC-IOLs using the Student's t test and Chi-square test.RESULTS:Sixteen patients of 16 eyes with a mean age of 58.3±10.1y(42-76y)who received transscleral C-loop IOL implantation due to trauma,vitrectomy,or cataract surgery with inadequate capsule support showed improved visual acuity.The difference was not significant between two IOLs except the surgery time(P>0.05).The mean operation times of C-loop IOL surgery was 24.1±1.83min and 31.3±4.47min of the four-haptics PC-IOL method(P<0.0001).In the C-loop IOLs group,there was statistical difference between the preoperative and the postoperative UCVA(log MAR,1.20±0.50 vs 0.57±0.32,P=0.0003).There was no statistical difference between the preoperative and the postoperative BCVA(log MAR,0.66±0.46 vs 0.40±0.23,P=0.056).However,there was no statistically significant difference in postoperative UCVA and BCVA between the two IOLs(P>0.05).We did not detect any optic capture,IOL decentration or dislocation,suture exposed,or cystoid macular edema in patients underwent C-loop IOLs surgery.CONCLUSION:The novel flapless one-knot suture technique for transscleral fixation of C-loop IOL is a simple,reliable,and stable technique.展开更多
Dear Editor,I am writing this letter to present an unusual case of orbital inflammatory myofibroblastic tumor(IMT)diagnosed due to high intraocular pressure(IOP).IMT is a rare mesenchymal,low-grade malignant or border...Dear Editor,I am writing this letter to present an unusual case of orbital inflammatory myofibroblastic tumor(IMT)diagnosed due to high intraocular pressure(IOP).IMT is a rare mesenchymal,low-grade malignant or borderline tumor,composed of differentiated myofibroblastic spindle cells,often accompanied by plasma cells and lymphocyte infiltration[1].The onset in most patients is insidious.展开更多
AIM:To determine the distribution and associated factors of intraocular pressure(IOP) in an Iranian elderly population 60 years of age and above.METHODS:The present report is part of the Tehran Geriatric Eye study(TGE...AIM:To determine the distribution and associated factors of intraocular pressure(IOP) in an Iranian elderly population 60 years of age and above.METHODS:The present report is part of the Tehran Geriatric Eye study(TGES),a population-based cross-sectional study that was conducted on the residents of Tehran 60 years of age and above.The sampling was performed using multistage stratified random cluster sampling methods from 22 districts of Tehran,Iran.Demographic and history information,blood samples,and blood pressure were collected from all participants.Ocular examinations included measurement of uncorrected and best-corrected visual acuity,objective and subjective refraction,and slit-lamp biomicroscopy.The IOP was measured using Goldmann applanation tonometry(GAT).Corneal imaging and ocular biometry were performed using Pentacam AXL.RESULTS:The data of 3892 eyes of 2124 individuals were analyzed for this report.The mean age of the study participants was 66.49±5.31y(range:60 to 95y).The mean IOP was 15.2 mm Hg(95%CI:15.1 to 15.4),15.3 mm Hg(95%CI:15.1 to 15.5) and 15.1 mm Hg(95%CI:15.0 to 15.3) in all participants,males,and females,respectively.Of the study participants,1.3% had an IOP of ≥20 mm Hg.The mean IOP increased from 15.1 mm Hg in the age group 60-64y to 16.3 mm Hg in the age group ≥80y.According to the final multiple GEE model,the IOP was statistically significantly higher in men than in women.All the studied age groups,except for the 75-79-year-old age group,had significantly higher IOP compared to the 60-64-year-old age group.The IOP was significantly higher in underweight compared to other body mass index groups.Moreover,the IOP had a statistically significant direct relationship with the mean corneal power(mean CP),central corneal thickness(CCT),and systolic blood pressure.CONCLUSION:The present study presents the distribution of IOP in an Iranian elderly population.A higher IOP(within the range 14 to 17 mm Hg) is significantly associated with older age,male sex,high systolic blood pressure,increased mean CP,and CCT.These factors should be considered in the clinical interpretation of IOP.展开更多
AIM:To assess the performance of a bespoke software for automated counting of intraocular lens(IOL)glistenings in slit-lamp images.METHODS:IOL glistenings from slit-lamp-derived digital images were counted manually an...AIM:To assess the performance of a bespoke software for automated counting of intraocular lens(IOL)glistenings in slit-lamp images.METHODS:IOL glistenings from slit-lamp-derived digital images were counted manually and automatically by the bespoke software.The images of one randomly selected eye from each of 34 participants were used as a training set to determine the threshold setting that gave the best agreement between manual and automatic grading.A second set of 63 images,selected using randomised stratified sampling from 290 images,were used for software validation.The images were obtained using a previously described protocol.Software-derived automated glistenings counts were compared to manual counts produced by three ophthalmologists.RESULTS:A threshold value of 140 was determined that minimised the total deviation in the number of glistenings for the 34 images in the training set.Using this threshold value,only slight agreement was found between automated software counts and manual expert counts for the validating set of 63 images(κ=0.104,95%CI,0.040-0.168).Ten images(15.9%)had glistenings counts that agreed between the software and manual counting.There were 49 images(77.8%)where the software overestimated the number of glistenings.CONCLUSION:The low levels of agreement show between an initial release of software used to automatically count glistenings in in vivo slit-lamp images and manual counting indicates that this is a non-trivial application.Iterative improvement involving a dialogue between software developers and experienced ophthalmologists is required to optimise agreement.The results suggest that validation of software is necessary for studies involving semi-automatic evaluation of glistenings.展开更多
AIM:To evaluate the diagnostic value of panoramic immersion B-scan ultrasonography(Pano-immersion B-scan,PIB)in complex retinal detachment(RD),persistent hyperplastic primary vitreous(PHPV)and intraocular tumors.METHO...AIM:To evaluate the diagnostic value of panoramic immersion B-scan ultrasonography(Pano-immersion B-scan,PIB)in complex retinal detachment(RD),persistent hyperplastic primary vitreous(PHPV)and intraocular tumors.METHODS:The clinical data of 44 patients collected from May 2012 to December 2019 in Chinese PLA General Hospital was retrospectively studied.All of these patients underwent PIB of the eye,because it was difficult to diagnose by routine ocular fundus examination,conventional ultrasound or/and ultrasonic biomicroscope(UBM)due to opacity of refractive media,pupillary occlusion,large involvement or special location of the lesion.The imaging features of difficult cases in PIB were analyzed.The diagnosis accuracy rating of PIB were evaluated and contrasted with conventional ultrasound or UBM by the standard of intraoperative diagnosis or/and pathological results.RESULTS:According to intraoperative diagnosis or pathological results as gold standard,among the 44 cases,there were 19 cases missed diagnosis,misdiagnosed or difficult-to-diagnose by conventional ultrasound or UBM,including 4 cases of long-standing RD difficult to diagnose,4 cases misdiagnosed,and 11 cases incompletely observed or miss diagnosed.The diagnostic accuracy rate of PIB and conventional ultrasound or UBM were 100%(44/44)and 56.82%(25/44),and the sensitivity of them were 100%and 56.82%.All the patients underwent PIB and were diagnosed as RD(15 cases),retinal and choroidal detachment(4 cases),subchoroidal hematocele(1 case),vitreous opacity and/or organic membrane formation(4 cases),PHPV(12 cases),iris and/or ciliary body tumors(3 cases),and choroidal tumors(6 cases).According to the intraoperative diagnosis or pathological results,the diagnostic coincidence rate of PIB was 100%,which was significantly higher than conventional ultrasound and UBM.CONCLUSION:PIB can help to accurately diagnose complex RD,PHPV,and intraocular masses with special location or/and excessive size.It has important diagnostic value for patients with equivocal findings at conventional ultrasound examination.展开更多
AIM:To compare the clinical outcomes between two approaches for sutureless scleral-fixated intraocular lens(SFIOL)in children with Marfan syndrome(MFS).METHODS:The study included 15 children(26 eyes)with lens subluxat...AIM:To compare the clinical outcomes between two approaches for sutureless scleral-fixated intraocular lens(SFIOL)in children with Marfan syndrome(MFS).METHODS:The study included 15 children(26 eyes)with lens subluxation due to MFS.These children underwent lensectomy,anterior vitrectomy,and sutureless SFIOL.According to the position of placement of intraocular lens(IOL)haptics,two study groups were reviewed for best corrected visual acuity(BCVA)and postoperative complications:group A,14 eyes with haptics fixated at 2.0 mm from the limbus;group B,12 eyes with the haptics fixated at 2.5 mm from the limbus.RESULTS:The mean axial length for all patients was 25.66±2.35 mm.Postoperative BCVA in logMAR were significant improved in both groups(0.77±0.32 to 0.17±0.12 in group A,0.66±0.25 to 0.24±0.12 in group B,both P<0.001)while no significant difference between two groups(P>0.05).Pupillary capture was main postoperative complication,occurring between 3d and 18mo.It occurred in 7 eyes in group A and one eye in group B(P=0.02).CONCLUSION:Sutureless SFIOL is an effective treatment approach for lens subluxation in children with MFS.Pupillary capture is the main postoperative complication.Fixated IOL haptics at 2.5 mm from the limbus can reduce the occurrence of pupillary capture.展开更多
·AIM:To investigate the efficacy of ripasudil,a Rho kinase inhibitor,in reducing intraocular pressure(IOP)and medication scores of anti-glaucoma drugs in patients with ocular hypertension with inflammation and co...·AIM:To investigate the efficacy of ripasudil,a Rho kinase inhibitor,in reducing intraocular pressure(IOP)and medication scores of anti-glaucoma drugs in patients with ocular hypertension with inflammation and corticosteroid.·METHODS:The study included 11 patients diagnosed with ocular hypertension with inflammation and corticosteroid,all of whom were prescribed ripasudil eye drops and followed up for at least 2y after the initiation of treatment.IOP was measured using a non-contact tonometer before enrollment and at each follow-up visit.The medication score of glaucoma eye drops was calculated for each patient.·RESULTS:The mean IOP(26.4±2.9 mm Hg before treatment)significantly decreased after ripasudil therapy(13.7±3.3 mm Hg at 3mo)and remained stable in the low-teens during the 2-year follow-up period(P<0.0001).A significant decrease in the medication score was observed at 12mo or later after the initiation of ripasudil therapy(P<0.05).Both baseline medication scores and glaucomatous optic disc change rates were significantly higher in the five eyes that required glaucoma surgery during the 2-year observation period than the 10 eyes that did not require surgery.·CONCLUSION:Our results demonstrate the efficacy of ripasudil,in reducing IOP and the medication score over a 2-year treatment period in patients with ocular hypertension with inflammation and corticosteroid.Our findings also suggest that ripasudil could reduce the IOP in uveitic glaucoma patients with both lower baseline medication score and lower glaucomatous optic disc change rate.展开更多
AIM:To compare intraocular pressure(IOP)measured via the trans palpebral IOP(tp IOP)method using a Diaton or with a Goldman applanation tonometer(GAT)and study the determinants of IOP difference in eyes undergoing tra...AIM:To compare intraocular pressure(IOP)measured via the trans palpebral IOP(tp IOP)method using a Diaton or with a Goldman applanation tonometer(GAT)and study the determinants of IOP difference in eyes undergoing transepithelial photorefractive keratectomy(TPRK)for myopia.METHODS:This cross-sectional validation study was held in 2020 in an eye hospital in Saudi Arabia.IOP was measured by Diaton and GAT before treatment,after one week,and one month of TPRK.It is considered if IOP difference by Diaton and GAT was less than±2 mm Hg acceptable.The IOP difference was tested if correlated to spherical equivalent(SE),central corneal thickness(CCT),age,gender,or tp IOP.RESULTS:Totolly 200 myopic eyes of 100 patients were included in the study.The mean difference of IOP measured by two methods before TPRK,1wk,and 1mo after TPRK were 0.790,-0.790,and-0.920 mm Hg,respectively(P<0.001).Diaton could measure IOP effectively 89.5%eyes before TPRK and 82%and 84%at 1wk and 1mo after TPTK,respectively.At week 1,IOP differences were significantly correlated to baseline CCT(P=0.02)and tp IOP at week 1(P<0.001).One month after TPRK,only tp IOP was significantly correlated to the difference in IOP(P<0.001).CONCLUSION:Diaton is a good screening tool for IOP before TPRK.It helps in monitoring IOP after surgery.Although more practical,it is less efficient than GAT.In eyes with high myopia and low tp IOP before surgery,IOP post-TPRK by Diaton and GAT could differ.展开更多
AIM:To evaluate the postoperative intraocular lens(IOL)rotational stability and residual refractive astigmatism following combined 25-gauge vitrectomy and cataract surgery with implantation of a plate haptic toric IOL...AIM:To evaluate the postoperative intraocular lens(IOL)rotational stability and residual refractive astigmatism following combined 25-gauge vitrectomy and cataract surgery with implantation of a plate haptic toric IOL.METHODS:In this retrospective case series,32 eyes of 32 patients underwent a combined 25-gauge vitrectomy and phacoemulsification for vitreoretinal diseases and cataract with regular corneal astigmatism of at least 1 diopter(D).A plate haptic toric IOL(AT Torbi 709M,Carl Zeiss Meditec AG)was implanted in all eyes.The outcome measures were rotational stability and refractive astigmatism up to 6mo postoperatively as well as the best corrected visual acuity(BCVA).RESULTS:Preoperative refractive astigmatism was 2.14±1.17 D,which was significantly reduced to 0.77±0.37 D six to eight weeks postoperatively and remained stable throughout the observation period(0.67±0.44 D at three months and 0.75±0.25 D at six months;for all groups:P<0.0001 compared to baseline).BCVA improved significantly from 0.36±0.33 logMAR preoperatively to 0.10±0.15 logMAR following surgery(P=0.02).Mean IOL axis deviation from the target axis was 3.4°±2.9°after six to eight weeks and significantly decreased over time(2.4°±2.6°six months after surgery;P=0.04).In one patient IOL,re-alignment was performed.CONCLUSION:Corneal astigmatism is significantly reduced following combined 25-gauge vitrectomy and cataract surgery.The plate haptic toric IOL position and axis remain stable during the observation period of six months.展开更多
文摘AIM:To evaluate the visual and refractive outcomes in cases after sutured scleral fixation of existing subluxated or dislocated acrylic one-piece intraocular lenses(IOLs).METHODS:This study retrospectively enrolled a consecutive series of patients who underwent a surgery of sutured existing subluxated or dislocated IOLs from October 2018 to June 2020.All patients underwent comprehensive preoperative and postoperative ophthalmologic examination,and data were collected including age,sex,surgical indications,best-corrected visual acuity,refractive error,intraocular pressure.Presence of intraoperative and postoperative surgical complications was documented.RESULTS:A total of 20 consecutive cases were enrolled for analysis with mean final follow-up period 9.8±5.3mo.Visual acuity improved from a mean of 0.35(0.46±0.32 logMAR)preoperatively to 0.61(0.21±0.18 logMAR)at the 3-month follow-up(P=0.002).The mean amount of preoperative keratometric astigmatism and total postoperative refractive astigmatism was-1.24±0.80 diopters(D)and-1.42±0.97 D,respectively.There was no statistically significant difference between preoperative and postoperative astigmatism(P=0.156).The mean IOL-induced astigmatism was-0.23±0.53 D.The mean spherical equivalent at the 3-month follow-up was-0.1±0.94 D.No major complications were noted during the follow-up period.CONCLUSION:Surgical techniques using sutured scleral fixation of existing subluxated or dislocated acrylic one-piece IOLs result in favorable visual and refractive outcomes without major complications.
文摘●AIM:To evaluate the effect of background diseases and number of previous intravitreal aflibercept injections(IVAIs)on immediate intraocular pressure(IOP)increase and vitreous reflux(VR)rate and to evaluate the correlation of both age and axial length with immediate IOP increase and VR rate.●METHODS:This study included 105 patients with cystoid macular edema secondary to retinal vein occlusion,35 patients with diabetic macular edema,69 patients with neovascular age-related macular degeneration(nAMD),and 12 patients with myopic choroidal neovascularization,which underwent first-time IVAI.The correlation of immediate IOP increase and VR rates with the four background diseases was investigated.Moreover,the correlation of age with immediate IOP increase and VR rate as well as correlation of axial length with immediate IOP increase and VR rate were evaluated.Further,54 patients with nAMD were treated with IVAI>10 times(multiple IVAIs).Moreover,the correlation of immediate IOP increase and VR rates with first-time and multiple IVAIs in nAMD was determined.●RESULTS:The immediate IOP increase(P=0.16)and VR rates(P=0.50)were almost similar among the four background diseases.The immediate postinjection IOP and age,VR rate and age,immediate postinjection IOP and axial length,or VR rate and axial length were not correlated in the four background diseases.The immediate IOP increase(P=0.66)and VR rates(P=0.28)did not significantly differ between first-time and multiple IVAIs in nAMD.●CONCLUSION:Background diseases and number of previous IVAIs have no effect on immediate IOP increase and VR rate.Further,age and axial length have no correlation on immediate IOP increase and VR rate.
基金supported by the National Natural Science Foundation of China,Nos.81570849,81100931the Natural Science Foundation of Guangdong Province of China,Nos.2015A030313446,2020A1515011413(all to LPC).
文摘Intraocular pressure elevation can induce retinal ganglion cell death and is a clinically reversible risk factor for glaucoma,the leading cause of irreversible blindness.We previously demonstrated that casein kinase-2 inhibition can promote retinal ganglion cell survival and axonal regeneration in rats after optic nerve injury.To investigate the underlying mechanism,in the current study we increased the intraocular pressure of adult rats to 75 mmHg for 2 hours and then administered a casein kinase-2 inhibitor(4,5,6,7-tetrabromo-2-azabenzimidazole or 2-dimethylamino-4,5,6,7-tetrabromo-1H-benzimidazole)by intravitreal injection.We found that intravitreal injection of 4,5,6,7-tetrabromo-2-azabenzimidazole or 2-dimethylamino-4,5,6,7-tetrabromo-1H-benzimidazole promoted retinal ganglion cell survival and reduced the number of infiltrating macrophages.Transcriptomic analysis showed that the mitogen activated protein kinase signaling pathway was involved in the response to intraocular pressure elevation but was not modulated by the casein kinase-2 inhibitors.Furthermore,casein kinase-2 inhibition downregulated the expression of genes(Cck,Htrsa,Nef1,Htrlb,Prph,Chat,Slc18a3,Slc5a7,Scn1b,Crybb2,Tsga10ip,and Vstm21)involved in intraocular pressure elevation.Our data indicate that inhibition of casein kinase-2 can enhance retinal ganglion cell survival in rats after acute intraocular pressure elevation via macrophage inactivation.
文摘The incidence of cataracts is significantly higher in diabetic individuals,particularly in younger age groups,with rates quadrupled in those under 65 and doubled in those over 65 compared to non-diabetics.Cataract surgery in diabetic patients poses many challenges:Poor epithelial healing,decreased corneal sensitivity,increased central corneal thickness,decreased endothelial cell count,variable topography,poor pupillary dilatation,anterior capsular phimosis,posterior capsular opacification(PCO),chances of progression of diabetic retinopathy(DR),zonular weakness,and vitreous prolapse and diabetic macular edema.Selection of an appropriate intraocular lens(IOL)is crucial for visual rehabilitation and monitoring DR.The choice of IOL in diabetic cataract patients is a challenging scenario.Square-edge IOLs are favored for their capacity to mitigate PCO,whereas hydrophilic counterparts may incur calcification in the setting of proliferative DR.The advisability of premium IOLs for achieving spectacle independence warrants judicious evaluation,particularly in the presence of advanced retinopathy.Optimal IOL placement within the capsular bag is advocated to minimize postoperative complications.Rigorous preoperative assessment and informed patient counseling regarding IOL options are indispensable for optimizing surgical outcomes.This review article covers various aspects regarding the choice of IOLs in different case scenarios and complications in the diabetic population.
文摘AIM:To investigate the influence of ophthalmic viscoelastic devices(OVDs)and different surgical approaches on the intraocular pressure(IOP)before and after creation of the curvilinear circular capsulorhexis(CCC)as a measure for anterior chamber stability during this maneuver.METHODS:Prospective experimental WetLab study carried out on enucleated porcine eyes.IOP was measured before and after CCC with the iCare Rebound tonometer(iCare ic200;iCare Finland Oy,Vantaa,Finland).The OVDs used were a cohesive one[Z-Hyalin,Carl Zeiss Meditec AG,Germany;hyaluronic acid(HA)]and a dispersive[Z-Celcoat,Carl Zeiss Meditec AG,Germany;hydroxy propylmethylcellulosis(HPMC)].The CCC was created using Utrata forceps or 23 g microforceps in different combinations with the OVDs.RESULTS:Using the Utrata forceps the IOP dropped from 63.65±6.44 to 11.25±3.63 mm Hg during the CCC.The use of different OVDs made no difference.Using the 23 g microforceps the IOP dropped from 65.35±8.15 to 36.55±6.09 mm Hg.The difference between IOP drop using either Utrata forceps or 23 g microforceps was highly significant regardless of the OVD used.CONCLUSION:Using the sideport for the creation of the capsulorhexis leads to a lesser drop in IOP during this maneuver compared to the main incision in enucleated porcine eyes.The use of different OVD has no significant influence on IOP drop.
文摘●AIM:To assess effectivity and safety of trifocal intraocular lenses(IOLs)and capsular tension rings in treating cataract patients with axial high myopia.●METHODS:A prospective nonrandomized controlled clinical trial was conducted.Totally 98 eyes(74 patients)who underwent femtosecond laser-assisted cataract surgery(FLACS)with trifocal IOLs were enrolled in the study and followed up for 2y after surgery:46 eyes(33 patients)with capsular tension ring implantation in the long axial lengths(AL)group(26<AL<29 mm)and 52 eyes(41 patients)in the normal AL group(22<AL<24.5 mm).Postoperative outcomes about effectivity and safety,including the subjective and objective visual quality,and postoperative complications were assessed.●RESULTS:Uncorrected distance visual acuity at 5 m and uncorrected intermediate visual acuity at 60 and 80 cm in the long AL group were significantly worse than those in the normal AL group at 3mo postoperatively(P<0.05).The differences in reading speed,spectacle independence and potential visual complaints between the two groups were not statistically significant(P>0.05).The dysfunctional lens index and total modulation transfer function(MTF)average height were similar between the two groups.The postoperative internal coma aberrations in the axial high myopia eyes were significantly higher than that in the normal AL group(P<0.05).The total satisfaction score in the long AL group(91.32±2.76)was slightly higher than that in the normal AL group(90.36±3.47),but there was no difference(P=0.136).A statistically negative correlation was found between corrected distance visual acuity(CDVA)and dysfunctional lens index(r=-0.382,P=0.009),and between CDVA and the total MTF average height(r=-0.374,P=0.01).But there was no significant correlation between CDVA and total satisfaction score(r=0.059,P=0.696).Postoperative complications mainly presented as posterior capsular opacity(PCO),retinal detachment and cystoid macular edema.There was no difference in the incidence of fundus disease(6.5%vs 3.8%,P=0.663)or PCO(17.4%vs 7.7%,P=0.217)between the two groups at two years.●CONCLUSION:The utilization of trifocal IOL and capsular tension ring implantation is beneficial for cataract patients with axial high myopia undergoing FLACS.This approach not only ensures excellent subjective feelings and objective visual quality,but also does not increase the incidence of postoperative complications.
基金supported by the National Natural Science Foundation of China,No.82371051(to DW)the Natural Science Foundation of Beijing,No.7212092(to DW)+1 种基金the Capital’s Funds for Health Improvement and Research,No.2022-2-5041(to DW)the Fund of Science and Technology Development of Beijing Rehabilitation Hospital,Capital Medical University,No.2021R-001(to YL).
文摘High intraocular pressure causes retinal ganglion cell injury in primary and secondary glaucoma diseases,yet the molecular landscape characteristics of retinal cells under high intraocular pressure remain unknown.Rat models of acute hypertension ocular pressure were established by injection of cross-linked hyaluronic acid hydrogel(Healaflow■).Single-cell RNA sequencing was then used to describe the cellular composition and molecular profile of the retina following high intraocular pressure.Our results identified a total of 12 cell types,namely retinal pigment epithelial cells,rod-photoreceptor cells,bipolar cells,Müller cells,microglia,cone-photoreceptor cells,retinal ganglion cells,endothelial cells,retinal progenitor cells,oligodendrocytes,pericytes,and fibroblasts.The single-cell RNA sequencing analysis of the retina under acute high intraocular pressure revealed obvious changes in the proportions of various retinal cells,with ganglion cells decreased by 23%.Hematoxylin and eosin staining and TUNEL staining confirmed the damage to retinal ganglion cells under high intraocular pressure.We extracted data from retinal ganglion cells and analyzed the retinal ganglion cell cluster with the most distinct expression.We found upregulation of the B3gat2 gene,which is associated with neuronal migration and adhesion,and downregulation of the Tsc22d gene,which participates in inhibition of inflammation.This study is the first to reveal molecular changes and intercellular interactions in the retina under high intraocular pressure.These data contribute to understanding of the molecular mechanism of retinal injury induced by high intraocular pressure and will benefit the development of novel therapies.
基金the Youth Project of Changzhou Health Commission,No.QN202129.
文摘BACKGROUND The prevalence of diabetes mellitus(DM)in China is high,and the base is broad.Diabetic retinopathy(DR)is a critical condition affecting the life and health of a nation and its economic development.DR is a common complication of DM.AIM To investigate the efficacy of laser photocoagulation combined with intravitreal injection of conbercept for treating macular edema.METHODS Overall,130 patients with diabetic macular edema(DME)hospitalized in The Third People’s Hospital of Changzhou from January 2019 to June 2022 were retrospectively included.According to the treatment plan,130 patients with DME were categorized into an observation and a control group,with 65 patients in each group.The control group received laser photocoagulation,and the observation group received laser photocoagulation with intravitreal injection of conbercept.Observe changes in vision,cytokines in the eye and so on.RESULTS The total efficacy rate in the observation group(93.85%)was higher than that in the control group(78.46%)(P<0.05).In both groups,the best corrected visual acuity correction effect improved after treatment,and the observation group was superior to the control group(P<0.05).Retinal thickness and central macular thickness improved after treatment,and the observation group was superior to the control group(P<0.05).The levels of vascular endothelial growth factor,interleukin-6,soluble intercellular adhesion molecule-1,and basic fibroblast growth factor in both groups improved after treatment,and the observation group was superior to the control group(P<0.05).CONCLUSION In patients with macular edema,combining laser photocoagulation and intravitreal injections of conbercept for DME is a more effective and safer strategy to improve vision,and lower intraocular cytokine levels.
基金Supported by the Gongli Hospital of Pudong New Area,Shanghai(No.2017YQNJJ-13)。
文摘AIM:To describe a novel suture approach for transscleral fixation of C-loop intraocular lenses(IOL)and to compare the surgical outcomes with the four-haptics posterior chamber(PC)-IOL technique.METHODS:We retrospectively analyzed 16 eyes of 16 patients who underwent transscleral fixation of C-loop PCIOLs using a flapless one-knot suture technique,which were followed up for longer than 17mo.In this technique,the capsulorless IOL was suspended using a single suture for transscleral fixation of four feet.Then we compared its surgical outcomes and complications with the four-haptics PC-IOLs using the Student's t test and Chi-square test.RESULTS:Sixteen patients of 16 eyes with a mean age of 58.3±10.1y(42-76y)who received transscleral C-loop IOL implantation due to trauma,vitrectomy,or cataract surgery with inadequate capsule support showed improved visual acuity.The difference was not significant between two IOLs except the surgery time(P>0.05).The mean operation times of C-loop IOL surgery was 24.1±1.83min and 31.3±4.47min of the four-haptics PC-IOL method(P<0.0001).In the C-loop IOLs group,there was statistical difference between the preoperative and the postoperative UCVA(log MAR,1.20±0.50 vs 0.57±0.32,P=0.0003).There was no statistical difference between the preoperative and the postoperative BCVA(log MAR,0.66±0.46 vs 0.40±0.23,P=0.056).However,there was no statistically significant difference in postoperative UCVA and BCVA between the two IOLs(P>0.05).We did not detect any optic capture,IOL decentration or dislocation,suture exposed,or cystoid macular edema in patients underwent C-loop IOLs surgery.CONCLUSION:The novel flapless one-knot suture technique for transscleral fixation of C-loop IOL is a simple,reliable,and stable technique.
基金Supported by the Xi’an Science and Technology Plan Project(No.21YXYJ0044)the Research Incubaiton of Xi’an People’s Hospital(Xi’an Fourth Hospital,No.BS-2)。
文摘Dear Editor,I am writing this letter to present an unusual case of orbital inflammatory myofibroblastic tumor(IMT)diagnosed due to high intraocular pressure(IOP).IMT is a rare mesenchymal,low-grade malignant or borderline tumor,composed of differentiated myofibroblastic spindle cells,often accompanied by plasma cells and lymphocyte infiltration[1].The onset in most patients is insidious.
基金Supported by National Institute for Medical Research Development (NIMAD) affiliated with the Iranian Ministry of Health and Medical Education (No.963660)。
文摘AIM:To determine the distribution and associated factors of intraocular pressure(IOP) in an Iranian elderly population 60 years of age and above.METHODS:The present report is part of the Tehran Geriatric Eye study(TGES),a population-based cross-sectional study that was conducted on the residents of Tehran 60 years of age and above.The sampling was performed using multistage stratified random cluster sampling methods from 22 districts of Tehran,Iran.Demographic and history information,blood samples,and blood pressure were collected from all participants.Ocular examinations included measurement of uncorrected and best-corrected visual acuity,objective and subjective refraction,and slit-lamp biomicroscopy.The IOP was measured using Goldmann applanation tonometry(GAT).Corneal imaging and ocular biometry were performed using Pentacam AXL.RESULTS:The data of 3892 eyes of 2124 individuals were analyzed for this report.The mean age of the study participants was 66.49±5.31y(range:60 to 95y).The mean IOP was 15.2 mm Hg(95%CI:15.1 to 15.4),15.3 mm Hg(95%CI:15.1 to 15.5) and 15.1 mm Hg(95%CI:15.0 to 15.3) in all participants,males,and females,respectively.Of the study participants,1.3% had an IOP of ≥20 mm Hg.The mean IOP increased from 15.1 mm Hg in the age group 60-64y to 16.3 mm Hg in the age group ≥80y.According to the final multiple GEE model,the IOP was statistically significantly higher in men than in women.All the studied age groups,except for the 75-79-year-old age group,had significantly higher IOP compared to the 60-64-year-old age group.The IOP was significantly higher in underweight compared to other body mass index groups.Moreover,the IOP had a statistically significant direct relationship with the mean corneal power(mean CP),central corneal thickness(CCT),and systolic blood pressure.CONCLUSION:The present study presents the distribution of IOP in an Iranian elderly population.A higher IOP(within the range 14 to 17 mm Hg) is significantly associated with older age,male sex,high systolic blood pressure,increased mean CP,and CCT.These factors should be considered in the clinical interpretation of IOP.
文摘AIM:To assess the performance of a bespoke software for automated counting of intraocular lens(IOL)glistenings in slit-lamp images.METHODS:IOL glistenings from slit-lamp-derived digital images were counted manually and automatically by the bespoke software.The images of one randomly selected eye from each of 34 participants were used as a training set to determine the threshold setting that gave the best agreement between manual and automatic grading.A second set of 63 images,selected using randomised stratified sampling from 290 images,were used for software validation.The images were obtained using a previously described protocol.Software-derived automated glistenings counts were compared to manual counts produced by three ophthalmologists.RESULTS:A threshold value of 140 was determined that minimised the total deviation in the number of glistenings for the 34 images in the training set.Using this threshold value,only slight agreement was found between automated software counts and manual expert counts for the validating set of 63 images(κ=0.104,95%CI,0.040-0.168).Ten images(15.9%)had glistenings counts that agreed between the software and manual counting.There were 49 images(77.8%)where the software overestimated the number of glistenings.CONCLUSION:The low levels of agreement show between an initial release of software used to automatically count glistenings in in vivo slit-lamp images and manual counting indicates that this is a non-trivial application.Iterative improvement involving a dialogue between software developers and experienced ophthalmologists is required to optimise agreement.The results suggest that validation of software is necessary for studies involving semi-automatic evaluation of glistenings.
文摘AIM:To evaluate the diagnostic value of panoramic immersion B-scan ultrasonography(Pano-immersion B-scan,PIB)in complex retinal detachment(RD),persistent hyperplastic primary vitreous(PHPV)and intraocular tumors.METHODS:The clinical data of 44 patients collected from May 2012 to December 2019 in Chinese PLA General Hospital was retrospectively studied.All of these patients underwent PIB of the eye,because it was difficult to diagnose by routine ocular fundus examination,conventional ultrasound or/and ultrasonic biomicroscope(UBM)due to opacity of refractive media,pupillary occlusion,large involvement or special location of the lesion.The imaging features of difficult cases in PIB were analyzed.The diagnosis accuracy rating of PIB were evaluated and contrasted with conventional ultrasound or UBM by the standard of intraoperative diagnosis or/and pathological results.RESULTS:According to intraoperative diagnosis or pathological results as gold standard,among the 44 cases,there were 19 cases missed diagnosis,misdiagnosed or difficult-to-diagnose by conventional ultrasound or UBM,including 4 cases of long-standing RD difficult to diagnose,4 cases misdiagnosed,and 11 cases incompletely observed or miss diagnosed.The diagnostic accuracy rate of PIB and conventional ultrasound or UBM were 100%(44/44)and 56.82%(25/44),and the sensitivity of them were 100%and 56.82%.All the patients underwent PIB and were diagnosed as RD(15 cases),retinal and choroidal detachment(4 cases),subchoroidal hematocele(1 case),vitreous opacity and/or organic membrane formation(4 cases),PHPV(12 cases),iris and/or ciliary body tumors(3 cases),and choroidal tumors(6 cases).According to the intraoperative diagnosis or pathological results,the diagnostic coincidence rate of PIB was 100%,which was significantly higher than conventional ultrasound and UBM.CONCLUSION:PIB can help to accurately diagnose complex RD,PHPV,and intraocular masses with special location or/and excessive size.It has important diagnostic value for patients with equivocal findings at conventional ultrasound examination.
文摘AIM:To compare the clinical outcomes between two approaches for sutureless scleral-fixated intraocular lens(SFIOL)in children with Marfan syndrome(MFS).METHODS:The study included 15 children(26 eyes)with lens subluxation due to MFS.These children underwent lensectomy,anterior vitrectomy,and sutureless SFIOL.According to the position of placement of intraocular lens(IOL)haptics,two study groups were reviewed for best corrected visual acuity(BCVA)and postoperative complications:group A,14 eyes with haptics fixated at 2.0 mm from the limbus;group B,12 eyes with the haptics fixated at 2.5 mm from the limbus.RESULTS:The mean axial length for all patients was 25.66±2.35 mm.Postoperative BCVA in logMAR were significant improved in both groups(0.77±0.32 to 0.17±0.12 in group A,0.66±0.25 to 0.24±0.12 in group B,both P<0.001)while no significant difference between two groups(P>0.05).Pupillary capture was main postoperative complication,occurring between 3d and 18mo.It occurred in 7 eyes in group A and one eye in group B(P=0.02).CONCLUSION:Sutureless SFIOL is an effective treatment approach for lens subluxation in children with MFS.Pupillary capture is the main postoperative complication.Fixated IOL haptics at 2.5 mm from the limbus can reduce the occurrence of pupillary capture.
文摘·AIM:To investigate the efficacy of ripasudil,a Rho kinase inhibitor,in reducing intraocular pressure(IOP)and medication scores of anti-glaucoma drugs in patients with ocular hypertension with inflammation and corticosteroid.·METHODS:The study included 11 patients diagnosed with ocular hypertension with inflammation and corticosteroid,all of whom were prescribed ripasudil eye drops and followed up for at least 2y after the initiation of treatment.IOP was measured using a non-contact tonometer before enrollment and at each follow-up visit.The medication score of glaucoma eye drops was calculated for each patient.·RESULTS:The mean IOP(26.4±2.9 mm Hg before treatment)significantly decreased after ripasudil therapy(13.7±3.3 mm Hg at 3mo)and remained stable in the low-teens during the 2-year follow-up period(P<0.0001).A significant decrease in the medication score was observed at 12mo or later after the initiation of ripasudil therapy(P<0.05).Both baseline medication scores and glaucomatous optic disc change rates were significantly higher in the five eyes that required glaucoma surgery during the 2-year observation period than the 10 eyes that did not require surgery.·CONCLUSION:Our results demonstrate the efficacy of ripasudil,in reducing IOP and the medication score over a 2-year treatment period in patients with ocular hypertension with inflammation and corticosteroid.Our findings also suggest that ripasudil could reduce the IOP in uveitic glaucoma patients with both lower baseline medication score and lower glaucomatous optic disc change rate.
文摘AIM:To compare intraocular pressure(IOP)measured via the trans palpebral IOP(tp IOP)method using a Diaton or with a Goldman applanation tonometer(GAT)and study the determinants of IOP difference in eyes undergoing transepithelial photorefractive keratectomy(TPRK)for myopia.METHODS:This cross-sectional validation study was held in 2020 in an eye hospital in Saudi Arabia.IOP was measured by Diaton and GAT before treatment,after one week,and one month of TPRK.It is considered if IOP difference by Diaton and GAT was less than±2 mm Hg acceptable.The IOP difference was tested if correlated to spherical equivalent(SE),central corneal thickness(CCT),age,gender,or tp IOP.RESULTS:Totolly 200 myopic eyes of 100 patients were included in the study.The mean difference of IOP measured by two methods before TPRK,1wk,and 1mo after TPRK were 0.790,-0.790,and-0.920 mm Hg,respectively(P<0.001).Diaton could measure IOP effectively 89.5%eyes before TPRK and 82%and 84%at 1wk and 1mo after TPTK,respectively.At week 1,IOP differences were significantly correlated to baseline CCT(P=0.02)and tp IOP at week 1(P<0.001).One month after TPRK,only tp IOP was significantly correlated to the difference in IOP(P<0.001).CONCLUSION:Diaton is a good screening tool for IOP before TPRK.It helps in monitoring IOP after surgery.Although more practical,it is less efficient than GAT.In eyes with high myopia and low tp IOP before surgery,IOP post-TPRK by Diaton and GAT could differ.
文摘AIM:To evaluate the postoperative intraocular lens(IOL)rotational stability and residual refractive astigmatism following combined 25-gauge vitrectomy and cataract surgery with implantation of a plate haptic toric IOL.METHODS:In this retrospective case series,32 eyes of 32 patients underwent a combined 25-gauge vitrectomy and phacoemulsification for vitreoretinal diseases and cataract with regular corneal astigmatism of at least 1 diopter(D).A plate haptic toric IOL(AT Torbi 709M,Carl Zeiss Meditec AG)was implanted in all eyes.The outcome measures were rotational stability and refractive astigmatism up to 6mo postoperatively as well as the best corrected visual acuity(BCVA).RESULTS:Preoperative refractive astigmatism was 2.14±1.17 D,which was significantly reduced to 0.77±0.37 D six to eight weeks postoperatively and remained stable throughout the observation period(0.67±0.44 D at three months and 0.75±0.25 D at six months;for all groups:P<0.0001 compared to baseline).BCVA improved significantly from 0.36±0.33 logMAR preoperatively to 0.10±0.15 logMAR following surgery(P=0.02).Mean IOL axis deviation from the target axis was 3.4°±2.9°after six to eight weeks and significantly decreased over time(2.4°±2.6°six months after surgery;P=0.04).In one patient IOL,re-alignment was performed.CONCLUSION:Corneal astigmatism is significantly reduced following combined 25-gauge vitrectomy and cataract surgery.The plate haptic toric IOL position and axis remain stable during the observation period of six months.