AIM: To investigate cap morphology after small-incision lenticule extraction (SMILE) and its effects on intraocular scattering. METHODS: Sixty-five eyes of 33 patients undergoing SMILE were enrolled. In addition ...AIM: To investigate cap morphology after small-incision lenticule extraction (SMILE) and its effects on intraocular scattering. METHODS: Sixty-five eyes of 33 patients undergoing SMILE were enrolled. In addition to regular evaluation, Fourier-domain optical coherence tomography was used to investigate cap thickness at ld, lwk, 1 and 3mo postoperatively. The optical quality including modulation transfer function cutoff frequency, Strehl ratio, Optical Quality Analysis System (OQAS) values, and objective scattering index (OSI), were evaluated using OQASTM. RESULTS: Cap thickness decreased from ld to lwk (P〈0.001), but remained higher than intended thickness of 120 μm after 3mo (P〈0.001). Cap thickness in central area was thinner than that of in the paracentral and peripheral areas (P〈0.0001). Total number of microdistortions decreased from ld to 3mo (P〈0.0001). Pearson analysis revealed a weak correlation between OSI and standard deviation of cap thickness at ld and lmo, as well as between range of cap thickness and OSI at 1mo. No correlation was found between microdistortion and OSI, but a negative correlation existed between microdistortion and range at ld and lmoafter surgery. CONCLUSION: The corneal cap tends to be more accurate and regular with time lapse. Better cap morphology tends to contribute less intraocular scattering in the eyes undergoing SMILE.展开更多
文摘AIM: To investigate cap morphology after small-incision lenticule extraction (SMILE) and its effects on intraocular scattering. METHODS: Sixty-five eyes of 33 patients undergoing SMILE were enrolled. In addition to regular evaluation, Fourier-domain optical coherence tomography was used to investigate cap thickness at ld, lwk, 1 and 3mo postoperatively. The optical quality including modulation transfer function cutoff frequency, Strehl ratio, Optical Quality Analysis System (OQAS) values, and objective scattering index (OSI), were evaluated using OQASTM. RESULTS: Cap thickness decreased from ld to lwk (P〈0.001), but remained higher than intended thickness of 120 μm after 3mo (P〈0.001). Cap thickness in central area was thinner than that of in the paracentral and peripheral areas (P〈0.0001). Total number of microdistortions decreased from ld to 3mo (P〈0.0001). Pearson analysis revealed a weak correlation between OSI and standard deviation of cap thickness at ld and lmo, as well as between range of cap thickness and OSI at 1mo. No correlation was found between microdistortion and OSI, but a negative correlation existed between microdistortion and range at ld and lmoafter surgery. CONCLUSION: The corneal cap tends to be more accurate and regular with time lapse. Better cap morphology tends to contribute less intraocular scattering in the eyes undergoing SMILE.