Effects of two types of intrauterine device (IUD) on the prostaglandins and endothelin (ET) in uterus and on the endometrial morphology in rats and rabbits, and Cu 2+ releasing amounts of both IUDs in vitro w...Effects of two types of intrauterine device (IUD) on the prostaglandins and endothelin (ET) in uterus and on the endometrial morphology in rats and rabbits, and Cu 2+ releasing amounts of both IUDs in vitro were observed. The results showed that the inhibiting action of the indomethacin releasing copper IUD (FICu IUD) on the PGI 2 was stronger than that on the TXA 2, the ratio of 6 keto PGF 1α /TXB 2 was reduced with the increase of the doses. There were significant differences between the groups. The FICu IUD could inhibit the rising of the ET level and lighten the endometrial impairment caused by the FCu IUD, and promote copper ion release. It was suggested that indomethacin released by FICu IUD could effectively reduce abnormal uterine bleeding.展开更多
Three hundred and eighty four women in Shanghai who delivered vaginally and chose IUD for contraception received the copper T 380A IUD inserted vaginally within 10 min after delivery of the placenta(i.e.,immediate pos...Three hundred and eighty four women in Shanghai who delivered vaginally and chose IUD for contraception received the copper T 380A IUD inserted vaginally within 10 min after delivery of the placenta(i.e.,immediate postplacental insertion, IPPI). Among them, 98.70% were primipara. The women were randomly divided into two groups: IUD inserted by hand and IUD insreted by ring forceps. Using Life Table Method and χ 2 test, expulsion and other discontinuation rates were compared at 6, 12, 24, and 36 months post insertion between these two different groups. No uterine perforation, infection or prolonged period of lochia occurred in the 384 cases. Expulsions were the main reason for discontinuation. From 6 months to 36 months, the gross cumulative rates of all discontinuation events (expulsion, pregnancy, removal for bleeding/pain, etc.) were not statistically significantly different (P>0.05). The results suggest that these two different insertion techniques do not significantly affect discontinuation rate in vaginal IPPI using the TCu 380 A, which appears to be suitable for postpartum insertion in Chinese women. Other relevant issues, such as breast feeding and IUD position in uterine cavity, are also analyzed and discussed in this paper.展开更多
The use of copper-containing intrauterine devices(Cu-IUDs)is a safe,effective,and long-term contraceptive method.Here,we review the effects of Cu-IUDs on subsequent pregnancy and the morphology,local coagulation funct...The use of copper-containing intrauterine devices(Cu-IUDs)is a safe,effective,and long-term contraceptive method.Here,we review the effects of Cu-IUDs on subsequent pregnancy and the morphology,local coagulation function,sensitivity to estrogen and progesterone,cell proliferation,and immune response of the endometrium.Studies on the morphology of endometrium indicate that the use of Cu-IUDs can affect the number and binding capacity of estrogen and progesterone receptors in the endometrium and reduce the response of the endometrium to estrogen and progesterone.The use of Cu-IUDs can also affect the proliferation of endometrial cells,suggesting that the aseptic inflammation caused by Cu-IUDs may differ from chronic infectious or noninfectious inflammation;this highlights that the use of Cu-IUDs provides protection against endometrial proliferative diseases.The use of Cu-IUDs increases local endometrial angiogenesis,bleeding tendency,and fibrinolytic activity,which can result in prolonged menstruation or abnormal uterine bleeding.Additionally,the use of Cu-IUDs can cause the infiltration of numerous lymphocytes,monocytes,macrophages,and other inflammatory cells around the endometrial gland and changes in endometrial immune function,immune cell function,and the number and type of immune molecules.Cu-IUD-induced decidual injury significantly increases the invasiveness of trophoblasts,further affecting the aberrant expression of their growth-,angiogenesis-,and invasion-related factors and improving the formation of the placenta.Moreover,the endometrial damage caused by Cu-IUD placement before embryo transfer can improve both clinical pregnancy and live birth rates;however,specific changes in the immune system after Cu-IUD use as well as its effects on future pregnancies require further investigation.展开更多
Objective To evaluate the cytotoxicity of six commonly used copper-bearing intrauterine devices (Cu-IUDs) on Chinese hamster ovary (CHO-K1) cells and to investigate the influence of frame, shape and copper surface...Objective To evaluate the cytotoxicity of six commonly used copper-bearing intrauterine devices (Cu-IUDs) on Chinese hamster ovary (CHO-K1) cells and to investigate the influence of frame, shape and copper surface area of Cu-IUDs on cell toxicity.Methods Cu-IUDs were incubated in 10% FBS-DMEM/F12 culture medium at 37 ℃ for 24 h. The extracts were analyzed by flame atomic absorption spectrometer and were then diluted into different concentrations with culture medium. Finally, cytotoxicity of these original and diluted extracts on CHO-K1 cells was detected by cell counting kit-8 (CCK-8) assay.Results The viabilities of cells treated with the original extracts of six Cu-IUDs (TCu220C bulb, TCu220C, GCu220, GCu300, Yuangong Cu270 and Yuangong Ⅱ- 300) were all below 10% and the cupric ion concentrations in these extracts were 28.22 mg/L, 31.80 mg/L, 92.80 mg/L, 99.74 mg/L, 114.90 mg/L and 119.20 mg/L, respectively. After these original extracts were diluted, significant differences in cytotoxicity were exhibited. IUDs with larger copper surface areas (GCu300 and Yuangong Ⅱ-300) showed more cytotoxicity than those with smaller areas (GCu220 and Yuangong Cu270) respectively; When different shapes of Cu-IUDs were compared, TCu220C bulb showed lower cytotoxicity than TCu220C, and GCu300 exhibited higher toxicity than Yuangong Ⅱ-300; TCu220C displayed significantly lower cytotoxicity than GCu220 due to their differences in frames.Conclusion We presented evidence on the cytotoxic effects of copper ions released from Cu-IUDs on CHO-K1 cells and found that shape, frame together with copper surface area of Cu-IUDs had obvious influence on the cytotoxicity.展开更多
Objective To compare the cupric ion releasing in vitro o.f the three IUDs. Methods The stability o.f cupric ion releasing o.f IUDs including TCu 380.4 IUD (TCu 380A), Multiload Cu375 IUD (MCu 375) and Yuangong 365...Objective To compare the cupric ion releasing in vitro o.f the three IUDs. Methods The stability o.f cupric ion releasing o.f IUDs including TCu 380.4 IUD (TCu 380A), Multiload Cu375 IUD (MCu 375) and Yuangong 365 copper-bearing indomethacin-releasing IUD (Yuangong 365) by the determination of cupric ion releasing in simulated uterine fluid. The simulated uterine fluid was used for releasing media. Copper ion was determined by flame atomic absorption spectrometer. Results The cupric ion releasing of three IUDs were instable at the beginning and tend to be stable gradually. In the stable phase, the average level of cupric ion releasing of TCu380A, MCu375 and Yuangong 365 were 4.25±2.71-7.62±6.42 μg, 4.92±1.23 -8.62±3.08 μg and 2.19±0.40-4.68±1.66 μg, respectively. TCu380A had higher instable releasing level than those of Yuangong 365 (P〈0. 05). Conclusion TCu 380.4 and MCu 375 showed a "burst release" during the first few days and the.former was of great significance(P〈0.05). The initial cupric ion releasing of Yuangong 365 appeared to be the lowest, followed by MCu375 and TCu380A in a releasing order展开更多
目的:研究不同分娩方式妇女放置三种新型含铜宫内节育器(CulUD)的术时评价。方法:将观察对象按经阴道和经剖宫产的不同分娩方式分为两组,每组均随机放置CyneFix IN IUD、MCu功能性IUD和TCu380A IUD,记录两组放置不同种IUD的扩宫情况、...目的:研究不同分娩方式妇女放置三种新型含铜宫内节育器(CulUD)的术时评价。方法:将观察对象按经阴道和经剖宫产的不同分娩方式分为两组,每组均随机放置CyneFix IN IUD、MCu功能性IUD和TCu380A IUD,记录两组放置不同种IUD的扩宫情况、置器疼痛反应和置器时间。结果:放置GyneFix IN IUD和TCu380A IUD在不同分娩方式组中扩宫率、痛觉评分、置器时间无显著差异(P>0.05)。放置MCu功能性IUD在剖宫产分娩组扩宫率为92.5%,显著高于阴道分娩组的33.3%(P<0.05);痛觉评分为8.62±0.82分,显著高于阴道分娩组(P<0.01);置器时间为(9.62±3.15)min,较另两种IUD置器时间显著延长(P<0.05)。结论:GyneFix IN IUD和TCu380A IUD置器术时扩宫率低、费时少,疼痛反应轻,不受分娩方式影响。展开更多
基金This project was supported by a grant from Hubei Science and Technology Com mittee(No.96 1P190 1)
文摘Effects of two types of intrauterine device (IUD) on the prostaglandins and endothelin (ET) in uterus and on the endometrial morphology in rats and rabbits, and Cu 2+ releasing amounts of both IUDs in vitro were observed. The results showed that the inhibiting action of the indomethacin releasing copper IUD (FICu IUD) on the PGI 2 was stronger than that on the TXA 2, the ratio of 6 keto PGF 1α /TXB 2 was reduced with the increase of the doses. There were significant differences between the groups. The FICu IUD could inhibit the rising of the ET level and lighten the endometrial impairment caused by the FCu IUD, and promote copper ion release. It was suggested that indomethacin released by FICu IUD could effectively reduce abnormal uterine bleeding.
文摘Three hundred and eighty four women in Shanghai who delivered vaginally and chose IUD for contraception received the copper T 380A IUD inserted vaginally within 10 min after delivery of the placenta(i.e.,immediate postplacental insertion, IPPI). Among them, 98.70% were primipara. The women were randomly divided into two groups: IUD inserted by hand and IUD insreted by ring forceps. Using Life Table Method and χ 2 test, expulsion and other discontinuation rates were compared at 6, 12, 24, and 36 months post insertion between these two different groups. No uterine perforation, infection or prolonged period of lochia occurred in the 384 cases. Expulsions were the main reason for discontinuation. From 6 months to 36 months, the gross cumulative rates of all discontinuation events (expulsion, pregnancy, removal for bleeding/pain, etc.) were not statistically significantly different (P>0.05). The results suggest that these two different insertion techniques do not significantly affect discontinuation rate in vaginal IPPI using the TCu 380 A, which appears to be suitable for postpartum insertion in Chinese women. Other relevant issues, such as breast feeding and IUD position in uterine cavity, are also analyzed and discussed in this paper.
文摘The use of copper-containing intrauterine devices(Cu-IUDs)is a safe,effective,and long-term contraceptive method.Here,we review the effects of Cu-IUDs on subsequent pregnancy and the morphology,local coagulation function,sensitivity to estrogen and progesterone,cell proliferation,and immune response of the endometrium.Studies on the morphology of endometrium indicate that the use of Cu-IUDs can affect the number and binding capacity of estrogen and progesterone receptors in the endometrium and reduce the response of the endometrium to estrogen and progesterone.The use of Cu-IUDs can also affect the proliferation of endometrial cells,suggesting that the aseptic inflammation caused by Cu-IUDs may differ from chronic infectious or noninfectious inflammation;this highlights that the use of Cu-IUDs provides protection against endometrial proliferative diseases.The use of Cu-IUDs increases local endometrial angiogenesis,bleeding tendency,and fibrinolytic activity,which can result in prolonged menstruation or abnormal uterine bleeding.Additionally,the use of Cu-IUDs can cause the infiltration of numerous lymphocytes,monocytes,macrophages,and other inflammatory cells around the endometrial gland and changes in endometrial immune function,immune cell function,and the number and type of immune molecules.Cu-IUD-induced decidual injury significantly increases the invasiveness of trophoblasts,further affecting the aberrant expression of their growth-,angiogenesis-,and invasion-related factors and improving the formation of the placenta.Moreover,the endometrial damage caused by Cu-IUD placement before embryo transfer can improve both clinical pregnancy and live birth rates;however,specific changes in the immune system after Cu-IUD use as well as its effects on future pregnancies require further investigation.
基金supported by Public Service Platform of Science and Technology Projects in Data mining of contraceptives monitoring and research of risk assessment model(BM2012062)the Priority Academic Program Development of Jiangsu Higher Education Institutions
文摘Objective To evaluate the cytotoxicity of six commonly used copper-bearing intrauterine devices (Cu-IUDs) on Chinese hamster ovary (CHO-K1) cells and to investigate the influence of frame, shape and copper surface area of Cu-IUDs on cell toxicity.Methods Cu-IUDs were incubated in 10% FBS-DMEM/F12 culture medium at 37 ℃ for 24 h. The extracts were analyzed by flame atomic absorption spectrometer and were then diluted into different concentrations with culture medium. Finally, cytotoxicity of these original and diluted extracts on CHO-K1 cells was detected by cell counting kit-8 (CCK-8) assay.Results The viabilities of cells treated with the original extracts of six Cu-IUDs (TCu220C bulb, TCu220C, GCu220, GCu300, Yuangong Cu270 and Yuangong Ⅱ- 300) were all below 10% and the cupric ion concentrations in these extracts were 28.22 mg/L, 31.80 mg/L, 92.80 mg/L, 99.74 mg/L, 114.90 mg/L and 119.20 mg/L, respectively. After these original extracts were diluted, significant differences in cytotoxicity were exhibited. IUDs with larger copper surface areas (GCu300 and Yuangong Ⅱ-300) showed more cytotoxicity than those with smaller areas (GCu220 and Yuangong Cu270) respectively; When different shapes of Cu-IUDs were compared, TCu220C bulb showed lower cytotoxicity than TCu220C, and GCu300 exhibited higher toxicity than Yuangong Ⅱ-300; TCu220C displayed significantly lower cytotoxicity than GCu220 due to their differences in frames.Conclusion We presented evidence on the cytotoxic effects of copper ions released from Cu-IUDs on CHO-K1 cells and found that shape, frame together with copper surface area of Cu-IUDs had obvious influence on the cytotoxicity.
基金This study was supported by National Key Scientific and Technological Project(2004BA720A32)
文摘Objective To compare the cupric ion releasing in vitro o.f the three IUDs. Methods The stability o.f cupric ion releasing o.f IUDs including TCu 380.4 IUD (TCu 380A), Multiload Cu375 IUD (MCu 375) and Yuangong 365 copper-bearing indomethacin-releasing IUD (Yuangong 365) by the determination of cupric ion releasing in simulated uterine fluid. The simulated uterine fluid was used for releasing media. Copper ion was determined by flame atomic absorption spectrometer. Results The cupric ion releasing of three IUDs were instable at the beginning and tend to be stable gradually. In the stable phase, the average level of cupric ion releasing of TCu380A, MCu375 and Yuangong 365 were 4.25±2.71-7.62±6.42 μg, 4.92±1.23 -8.62±3.08 μg and 2.19±0.40-4.68±1.66 μg, respectively. TCu380A had higher instable releasing level than those of Yuangong 365 (P〈0. 05). Conclusion TCu 380.4 and MCu 375 showed a "burst release" during the first few days and the.former was of great significance(P〈0.05). The initial cupric ion releasing of Yuangong 365 appeared to be the lowest, followed by MCu375 and TCu380A in a releasing order
文摘目的:研究不同分娩方式妇女放置三种新型含铜宫内节育器(CulUD)的术时评价。方法:将观察对象按经阴道和经剖宫产的不同分娩方式分为两组,每组均随机放置CyneFix IN IUD、MCu功能性IUD和TCu380A IUD,记录两组放置不同种IUD的扩宫情况、置器疼痛反应和置器时间。结果:放置GyneFix IN IUD和TCu380A IUD在不同分娩方式组中扩宫率、痛觉评分、置器时间无显著差异(P>0.05)。放置MCu功能性IUD在剖宫产分娩组扩宫率为92.5%,显著高于阴道分娩组的33.3%(P<0.05);痛觉评分为8.62±0.82分,显著高于阴道分娩组(P<0.01);置器时间为(9.62±3.15)min,较另两种IUD置器时间显著延长(P<0.05)。结论:GyneFix IN IUD和TCu380A IUD置器术时扩宫率低、费时少,疼痛反应轻,不受分娩方式影响。