Effects of two types of intrauterine device (IUD) on the prostaglandins and endothelin (ET) in uterus and on the endometrial morphology in rats and rabbits, and Cu 2+ releasing amounts of both IUDs in vitro w...Effects of two types of intrauterine device (IUD) on the prostaglandins and endothelin (ET) in uterus and on the endometrial morphology in rats and rabbits, and Cu 2+ releasing amounts of both IUDs in vitro were observed. The results showed that the inhibiting action of the indomethacin releasing copper IUD (FICu IUD) on the PGI 2 was stronger than that on the TXA 2, the ratio of 6 keto PGF 1α /TXB 2 was reduced with the increase of the doses. There were significant differences between the groups. The FICu IUD could inhibit the rising of the ET level and lighten the endometrial impairment caused by the FCu IUD, and promote copper ion release. It was suggested that indomethacin released by FICu IUD could effectively reduce abnormal uterine bleeding.展开更多
Objective To compare the cupric ion releasing in vitro o.f the three IUDs. Methods The stability o.f cupric ion releasing o.f IUDs including TCu 380.4 IUD (TCu 380A), Multiload Cu375 IUD (MCu 375) and Yuangong 365...Objective To compare the cupric ion releasing in vitro o.f the three IUDs. Methods The stability o.f cupric ion releasing o.f IUDs including TCu 380.4 IUD (TCu 380A), Multiload Cu375 IUD (MCu 375) and Yuangong 365 copper-bearing indomethacin-releasing IUD (Yuangong 365) by the determination of cupric ion releasing in simulated uterine fluid. The simulated uterine fluid was used for releasing media. Copper ion was determined by flame atomic absorption spectrometer. Results The cupric ion releasing of three IUDs were instable at the beginning and tend to be stable gradually. In the stable phase, the average level of cupric ion releasing of TCu380A, MCu375 and Yuangong 365 were 4.25±2.71-7.62±6.42 μg, 4.92±1.23 -8.62±3.08 μg and 2.19±0.40-4.68±1.66 μg, respectively. TCu380A had higher instable releasing level than those of Yuangong 365 (P〈0. 05). Conclusion TCu 380.4 and MCu 375 showed a "burst release" during the first few days and the.former was of great significance(P〈0.05). The initial cupric ion releasing of Yuangong 365 appeared to be the lowest, followed by MCu375 and TCu380A in a releasing order展开更多
Objective: To assess levonorgestrel-releasing intrauterine system LNG-IUS (Mirena?) application at caesarean section (CS). Design: Randomized, comparative study. Setting: Department of obstetrics and gynecology in a p...Objective: To assess levonorgestrel-releasing intrauterine system LNG-IUS (Mirena?) application at caesarean section (CS). Design: Randomized, comparative study. Setting: Department of obstetrics and gynecology in a primary reference hospital at Puebla City, Mexico. Sample: 396 women requiring CS signed informed consent and were randomly allocated to the post-placental application of LNG-IUS (198) or Copper T 380 A (198). Methods: Follow up visits at 6 weeks, and 6 and 12 months were performed. Main Outcomes Measures: IUDs expulsion, maternal and babies’ health conditions, breastfeeding and menstrual patterns, adverse effects and pregnancies. Differences between groups were analyzed by Fisher and X2 tests, Odds ratios, relative risk and 95% confidence limits, as appropriate. Results: After one year of follow up, no pregnancies were reported. The IUD expulsion rate was 4.5% in each group. LNG-IUS users had a higher incidence of amenorrhea (OR 2.5 95% CI 2.2 - 3) and menstrual patterns significantly brief and lighter than Copper T 380 A (p < 0.001) with lower incidence of dysmenorrhea (OR 0.1 95% CI 0.04 - 0.2). No detrimental effects of LNG-IUS on breastfeeding was observed and interestingly babies weights of LNG-IUS users was slightly above the average for age compared with Copper T 380 A users. This was probably related with a major proportion of women with normal ferritin serum levels (94% vs 68%) leading to better mother’s general condition. Conclusions: LNG-IUS inserted during CS provides high efficacy contraception with additional benefits, mainly reducing menstrual bleeding and doing so, faster recovery of ferrous homeostasis after CS.展开更多
The use of copper-containing intrauterine devices(Cu-IUDs)is a safe,effective,and long-term contraceptive method.Here,we review the effects of Cu-IUDs on subsequent pregnancy and the morphology,local coagulation funct...The use of copper-containing intrauterine devices(Cu-IUDs)is a safe,effective,and long-term contraceptive method.Here,we review the effects of Cu-IUDs on subsequent pregnancy and the morphology,local coagulation function,sensitivity to estrogen and progesterone,cell proliferation,and immune response of the endometrium.Studies on the morphology of endometrium indicate that the use of Cu-IUDs can affect the number and binding capacity of estrogen and progesterone receptors in the endometrium and reduce the response of the endometrium to estrogen and progesterone.The use of Cu-IUDs can also affect the proliferation of endometrial cells,suggesting that the aseptic inflammation caused by Cu-IUDs may differ from chronic infectious or noninfectious inflammation;this highlights that the use of Cu-IUDs provides protection against endometrial proliferative diseases.The use of Cu-IUDs increases local endometrial angiogenesis,bleeding tendency,and fibrinolytic activity,which can result in prolonged menstruation or abnormal uterine bleeding.Additionally,the use of Cu-IUDs can cause the infiltration of numerous lymphocytes,monocytes,macrophages,and other inflammatory cells around the endometrial gland and changes in endometrial immune function,immune cell function,and the number and type of immune molecules.Cu-IUD-induced decidual injury significantly increases the invasiveness of trophoblasts,further affecting the aberrant expression of their growth-,angiogenesis-,and invasion-related factors and improving the formation of the placenta.Moreover,the endometrial damage caused by Cu-IUD placement before embryo transfer can improve both clinical pregnancy and live birth rates;however,specific changes in the immune system after Cu-IUD use as well as its effects on future pregnancies require further investigation.展开更多
Objective To evaluate the cytotoxicity of six commonly used copper-bearing intrauterine devices (Cu-IUDs) on Chinese hamster ovary (CHO-K1) cells and to investigate the influence of frame, shape and copper surface...Objective To evaluate the cytotoxicity of six commonly used copper-bearing intrauterine devices (Cu-IUDs) on Chinese hamster ovary (CHO-K1) cells and to investigate the influence of frame, shape and copper surface area of Cu-IUDs on cell toxicity.Methods Cu-IUDs were incubated in 10% FBS-DMEM/F12 culture medium at 37 ℃ for 24 h. The extracts were analyzed by flame atomic absorption spectrometer and were then diluted into different concentrations with culture medium. Finally, cytotoxicity of these original and diluted extracts on CHO-K1 cells was detected by cell counting kit-8 (CCK-8) assay.Results The viabilities of cells treated with the original extracts of six Cu-IUDs (TCu220C bulb, TCu220C, GCu220, GCu300, Yuangong Cu270 and Yuangong Ⅱ- 300) were all below 10% and the cupric ion concentrations in these extracts were 28.22 mg/L, 31.80 mg/L, 92.80 mg/L, 99.74 mg/L, 114.90 mg/L and 119.20 mg/L, respectively. After these original extracts were diluted, significant differences in cytotoxicity were exhibited. IUDs with larger copper surface areas (GCu300 and Yuangong Ⅱ-300) showed more cytotoxicity than those with smaller areas (GCu220 and Yuangong Cu270) respectively; When different shapes of Cu-IUDs were compared, TCu220C bulb showed lower cytotoxicity than TCu220C, and GCu300 exhibited higher toxicity than Yuangong Ⅱ-300; TCu220C displayed significantly lower cytotoxicity than GCu220 due to their differences in frames.Conclusion We presented evidence on the cytotoxic effects of copper ions released from Cu-IUDs on CHO-K1 cells and found that shape, frame together with copper surface area of Cu-IUDs had obvious influence on the cytotoxicity.展开更多
A comparative study was made on the contraception efficacy and safety of the vaginal ring releasing 10mg/day Of progesterone in 160 cases and an intrauterine device,the cOPPer T 380A in 100 cases during lactation.It w...A comparative study was made on the contraception efficacy and safety of the vaginal ring releasing 10mg/day Of progesterone in 160 cases and an intrauterine device,the cOPPer T 380A in 100 cases during lactation.It was found that the contraceptive method is acceptable from 42 to 60 days postpartum.No pregnancy occurred in the copper T 380A IUD users during lactation.Those methods are worth to be recommended because of their contraceptive efficacy and no adverse effects on breastfeeding children.Prenatal care and Family Planning Programe are administered together to raise lactation performance rate,and to decrease induced abortion rate,the health of mothers and children were protected.展开更多
The purpose of the study was to test the effective period of VCu200 IUD.The concentration of copper ion was measured with non-flame atomic absorption spectrophotometer HITACHI-180.The average concentration of coPPer i...The purpose of the study was to test the effective period of VCu200 IUD.The concentration of copper ion was measured with non-flame atomic absorption spectrophotometer HITACHI-180.The average concentration of coPPer ion(x±s.)was 2.66±0.58μg/g cervical mucus wet weight(μg/g·M·W·W) in the first year,then gradually decreasing to 0.91±0.16μg/g·M·W·W in the fifteenth-year group of VCu200 IUD.There was an average of 0.35±0.08~0.56±0.14 μg/g·M·W·W in the control group.It showed that the concentration of copper ion was decreasing with prolongation of use of VCu200 IUD and there was statistically significant difference between VCu200 IUD group,on the one hand,and the stainless steel ring group and the control group(P<0.05~0.01)on the other hand.No difference was found between the stainless steel ring group and the control group(P>0.05).It was reported in the literature that the concentration Of copper ion in 1.0μg/ml had the action of antifertility,and it was found that the concentration of copper ion was higher than 1.0μg/ml in the tenth year after insertion of VCu200 IUD.It suggested that effective period of VCu200 IUD was at least ten years.展开更多
Since copper has excellent properties such as malleability and conductivity,it is widely used in the electronics field.Copper sulfate plating is expanding further in fields requiring thick deposits such as for heat di...Since copper has excellent properties such as malleability and conductivity,it is widely used in the electronics field.Copper sulfate plating is expanding further in fields requiring thick deposits such as for heat dissipation boards and bumps for stress relaxation during semiconductor packaging.In this study,high-speed copper plating at 50 A/dm2 or more was achieved using a jet flow device.In addition,as a result of comparison with the low current density film,the current density had little effect on electrical conductivity and film surface structure.On the other hand,it was confirmed that the etching rate of the high current density film was greatly increased as the crystallites on the film surface became smaller than low current density film.Increase in productivity is expected due to shorter plating time enabled by film deposition at high current density.Furthermore,the increase of etching rate is expected to contribute to the suppression of undercuts that occur when removing the seed layer during wiring and bump fabrication.展开更多
Objective To explore and investigate a new treatment of releasing the risks and pain in removing intrauterine devices (IUD) from postmenopausal women. Methods Totally 240 postmenopausal women who needed to remove IU...Objective To explore and investigate a new treatment of releasing the risks and pain in removing intrauterine devices (IUD) from postmenopausal women. Methods Totally 240 postmenopausal women who needed to remove IUD were randomly divided into 3 groups. Group A (n =80) were preoperatively treated with 20 g/L vaginal testosterone propionate cod liver oil ointment (1 g/d) over a 2-week span of period, and vaginal misoprostol (200 μg) was one-time used at 2-3 h before operation. Group B (n =80) were treated with oral estradiol valerate (3 mg/d) from 7 d before operation. Other 80 women (group C) were treated with vaginal cod liver oil ointment (1 g/d) over a 2-week span of period before the operation day. The degree of cervical relaxation, operational difficulty, blood loss volume, the length of operation time and visual analogue scales (VAS) were evaluated, also the serum estradiol, testosterone and endometrial thickness were measured before and after medication. Results The degree of cervical relaxation, operational difficulty, blood loss, the length of operation time and VAS in group A were significantly better than those group C (P〈0.01), whiles its blood loss volume was less than group B (P〈0.05) and there were no significant differences in serum estradiol, testosterone and endometrial thickness before and after medication. Conclusion Preoperative vaginal testosterone propionate combined with misoprostol would reduce the operational difficulties/risks and release the suffering of patients. The study may represent a safe and effective alternative to remove IUD in postmeno- pausal women.展开更多
BACKGROUND An intrauterine device(IUD)is a contraceptive device placed in the uterine cavity and is a common contraceptive method for Chinese women.However,an IUD may cause complications due to placement time,intraute...BACKGROUND An intrauterine device(IUD)is a contraceptive device placed in the uterine cavity and is a common contraceptive method for Chinese women.However,an IUD may cause complications due to placement time,intrauterine pressure and other factors.Ectopic IUDs are among the most serious complications.Ectopic IUDs are common in the myometrium and periuterine organs,and there are few reports of ectopic IUDs in the urinary bladder,especially in the anterior wall.CASE SUMMARY A 52-year-old woman was hospitalized due to a urinary bladder foreign body found via abdominal ultrasound and computed tomography(CT)examination.The patient had a 2-year history of recurrent abdominal distension and lower abdominal pain,accompanied by frequent urination,urgency,dysuria and other discomfort.Ultrasound examination revealed foreign bodies in the bladder cavity,with calculus on the surface of the foreign bodies.CT revealed a circular foreign body on the anterior wall of the urinary bladder,suggesting the possibility of an ectopic IUD.After laparoscopic exploration,an annular IUD was found in the anterior wall of urinary bladder,and an oval calculus with a diameter of approximately 2 cm was attached to the surface of the bladder cavity.The IUD and calculus were successfully and completely removed.The patient recovered well after surgery.CONCLUSION Abdominal ultrasound and CT are effective methods for detecting ectopic IUDs.The IUD is located in the urinary bladder and requires early surgical treatment.The choice of surgical method is determined by comprehensively considering the depth of the IUD in the bladder muscle layer,the situation of complicated calculus,the situation of intravesical inflammation and medical technology and equipment.展开更多
The purpose of this study was to investigate the effects of copper/low-density polyethylene nanocomposite(nano-Cu/LDPE)on the endometrial angiogenesis in rats,and 100 sexual mature female SD rats were randomly divided...The purpose of this study was to investigate the effects of copper/low-density polyethylene nanocomposite(nano-Cu/LDPE)on the endometrial angiogenesis in rats,and 100 sexual mature female SD rats were randomly divided into five groups:sham-operation groups(SO group,n=20),bulk copper groups(Cu group,n=20),LDPE groups(n=20),nano-Cu/LDPE groups I(n=20)and II(n=20).The levels of angiopoietin-2(Ang-2),its receptor(Tie-2)and CD34 of the rats’endometria in each group were examined by using the S-P method of the immunohistochemistry 30 and 180 days after insertion,respectively.Compared with those in the SO group,the expression of Ang-2 and Tie-2 in all the experimental groups was obviously increased 30 days after insertion,and these parameters in nano-Cu/LDPE groups,except for Ang-2 level in nano-Cu/LDPE group II,were significantly lower in comparison with those in Cu group(P<0.05).On the 180th day after insertion,Ang-2 and Tie-2 levels were still higher in Cu group and LDPE group,but there was no difference of Ang-2 and Tie-2 levels between nano-Cu/LDPE groups and the SO group(P>0.05).Com-pared with those in the SO group,the significant increases in microvessel density(MVD)were observed on the 30th and the 180th day after the insertion of the bulk copper(P<0.05).There was no significant difference in MVD counts before and after the insertion of nano-Cu/LDPE(P>0.05).The results show that Nano-Cu/LDPE have slighter influence on the endometrial angiogenesis than bulk copper.展开更多
BACKGROUND Levonorgestrel-releasing intrauterine systems(LNG-IUSs)gradually release levonorgestrel into the uterus and is effective against hypermenorrhoea and dysmenorrhea.Complications associated with the insertion ...BACKGROUND Levonorgestrel-releasing intrauterine systems(LNG-IUSs)gradually release levonorgestrel into the uterus and is effective against hypermenorrhoea and dysmenorrhea.Complications associated with the insertion include expulsion,displacement,and uterine perforation.Ultrasonic identification of copper intrauterine devices(IUDs)is possible due to echogenicity from the copper coils.However,the barium sulfate coatings of LNG-IUSs do not always provide hyperechoic images.Both barium sulfate and copper are radiopaque and clearly identifiable on X-ray.Thus,X-ray imaging is required to locate LNG-IUSs.CASE SUMMARY A 46-year-old woman with hypermenorrhoea due to submucosal myomas was treated with LNG-IUS at another hospital.Three LNG-IUS insertions had apparently been followed by spontaneous expulsion,although objective confirmation using imaging was not performed.The patient was referred to our institution for surgery.At the first visit,there appeared to be no device in the uterus,and none was observed on transvaginal ultrasound.However,two LNGIUSs were observed in the pelvis on abdominal plain X-rays prior to surgery.Hysteroscopic myomectomy was performed,and the two LNG-IUSs were found to have perforated the myometrium.The devices were safely removed during surgery,and the submucosal myomas were also removed.The perforated section of the myometrium was minimal+ADs-therefore,a repair operation was not required.CONCLUSION Plain abdominal X-rays facilitate the determination of whether an LNG-IUS is in the uterine cavity.Therefore,it is important to confirm a device’s location,regardless of whether spontaneous expulsion is suspected,prior to inserting another device.展开更多
Three hundred and eighty four women in Shanghai who delivered vaginally and chose IUD for contraception received the copper T 380A IUD inserted vaginally within 10 min after delivery of the placenta(i.e.,immediate pos...Three hundred and eighty four women in Shanghai who delivered vaginally and chose IUD for contraception received the copper T 380A IUD inserted vaginally within 10 min after delivery of the placenta(i.e.,immediate postplacental insertion, IPPI). Among them, 98.70% were primipara. The women were randomly divided into two groups: IUD inserted by hand and IUD insreted by ring forceps. Using Life Table Method and χ 2 test, expulsion and other discontinuation rates were compared at 6, 12, 24, and 36 months post insertion between these two different groups. No uterine perforation, infection or prolonged period of lochia occurred in the 384 cases. Expulsions were the main reason for discontinuation. From 6 months to 36 months, the gross cumulative rates of all discontinuation events (expulsion, pregnancy, removal for bleeding/pain, etc.) were not statistically significantly different (P>0.05). The results suggest that these two different insertion techniques do not significantly affect discontinuation rate in vaginal IPPI using the TCu 380 A, which appears to be suitable for postpartum insertion in Chinese women. Other relevant issues, such as breast feeding and IUD position in uterine cavity, are also analyzed and discussed in this paper.展开更多
AIM: To review the safety (infection, perforation) and efficacy (expulsion, continuation rates, pregnancy) of intrauterine device (IUD) insertion in the postpartum period. METHODS: MEDLINE, PubMed and Google S...AIM: To review the safety (infection, perforation) and efficacy (expulsion, continuation rates, pregnancy) of intrauterine device (IUD) insertion in the postpartum period. METHODS: MEDLINE, PubMed and Google Scholar were searched for randomized controlled trials and prospective cohort studies of IUD insertions at different times during the postpartum period. Time of insertion during the postpartum period was documented speci-fically, immediate post placenta period (within 10 min), early post placenta period (10 min to 72 h), and de-layed/interval period (greater than 6 wk). Other study variables included mode of delivery, vaginal vs cesarean, manual vs use of ring forceps to insert the IUD. RESULTS: IUD insertion in the immediate postpartum (within 10 min of placental delivery), early postpartum (10 min up to 72 h) and Interval/Delayed (6 wk onward) were found to be safe and effcacious. Expulsion rates were found to be highest in the immediate postpartum groups ranging from 14% to 27%. Immediate post placental insertion found to have expulsion rates that ranged from 3.6% to 16.2%. Expulsion rate was significantly higher after insertion following vaginal vs cesarean delivery. The rates of infection, perforation and unplanned pregnancy following postpartum IUD insertion are low. Method of insertion such as with ring forceps, by hand, or another placement method unique to the type of IUD did not show any signifcant difference in expulsion rates. Uterine perforations are highest in the delayed/interval IUD insertion groups.Breastfeeding duration and infant development are not affected by delayed/interval insertion of the non-hormonal (copper) IUD or the Levonorgestrel IUD. Timing of the Levonorgestrel IUD insertion may affect breastfeeding. CONCLUSION: IUD insertion is safe and efficacious during the immediate postpartum, early postpartum and delayed postpartum periods. Expulsion rates are highest after vaginal delivery and when inserted during the immediate postpartum period. IUD associated infection rates were not increased by insertion during the postpartum period over interval insertion rates. There is no evidence that breastfeeding is negatively affected by postpartum insertion of copper or hormone-secreting IUD. Although perforation rates were higher when inserted after lactation was initiated. Randomized controlled trials are needed to further elucidate the consequence of lactation on postpartum insertion. Despite the concerns regarding expulsion, perforation and breastfeeding, current evidence indicates that a favorable risk beneft ratio in support of postpartum IUD insertion. This may be particularly relevant for women for whom barriers exist in achieving desired pregnancy spacing.展开更多
BACKGROUND A cystic lesion arising from the myometrium of the uterus, termed as cystic adenomyosis, has chocolate-like, thick viscous contents and contains various amounts of endometrial stroma below the glandular epi...BACKGROUND A cystic lesion arising from the myometrium of the uterus, termed as cystic adenomyosis, has chocolate-like, thick viscous contents and contains various amounts of endometrial stroma below the glandular epithelium. It is an extremely rare type of adenomyosis.CASE SUMMARY Herein, we report an unusual case of a giant cystic mass in the pelvic cavity after uterine myomectomy. The patient complained of abnormal uterine bleeding and severe dysmenorrhea. After a levonorgestrel-containing intrauterine device(LNG-IUD) was inserted, her symptoms were greatly alleviated. However, the LNG-IUD was detected in the cystic cavity during the follow-up. For fear of the intrauterine device migrating into and damaging the surrounding viscera,surgical treatment was proposed. Therefore, laparoscopic resection of the lesion and removal of the LNG-IUD were performed and cystic adenomyosis with an LNG-IUD out of the uterine cavity was diagnosed.CONCLUSION We believe that myomectomy breaking through the endometrial cavity may have been a predisposing factor for the development of cystic adenomyosis in this case.展开更多
BACKGROUND An intrauterine device(IUD)is a commonly used contraceptive among women in China.It is widely used because it is safe,effective,simple,economic,and reversible.Among the possible complications,an ectopic IUD...BACKGROUND An intrauterine device(IUD)is a commonly used contraceptive among women in China.It is widely used because it is safe,effective,simple,economic,and reversible.Among the possible complications,an ectopic IUD in the bladder is rare.It occurs insidiously,has a long course,is associated with a high risk for injury,and is difficult to treat.CASE SUMMARY A 44-year-old woman was admitted for repeated episodes of urinary frequency,urgency,and dysuria over three months.Laboratory tests revealed significantly elevated urine leukocytes and bacteria.Urine culture suggested colonization with Enterococcus faecalis.Abdominal computed tomography images suggested an abnormally positioned IUD that was protruding into the bladder.Cystoscopy revealed a metallic foreign body with multiple stones on its surface in the left posterior bladder wall.The foreign body measured approximately 1 cm.Hysteroscopy revealed the arm of a V-type metal IUD embedded in the middle and upper sections of the anterior wall of the cervical canal.The majority of the IUD was located in the uterine cavity.Cystoscopy was performed,and a holmium laser was utilized to break the stones attached to the portion of the IUD in the bladder.The IUD was then removed through hysteroscopy.CONCLUSION Ectopic IUDs in the bladder can be diagnosed with thorough imaging and safely removed through cystoscopy or hysteroscopy.展开更多
Effect of domestically-made levonorgestrel-releasing intrauterine device (LNG, release rate: 6 μg/day) on the endocrine system and menstruation in mondeys was investigated. The results showed that the Estradiol (E2) ...Effect of domestically-made levonorgestrel-releasing intrauterine device (LNG, release rate: 6 μg/day) on the endocrine system and menstruation in mondeys was investigated. The results showed that the Estradiol (E2) and progesterone (P) levels were significantly decreased 2 ovulatory cycles after iusertion of the devices as compared with those before insertion in 3 monkeys (P>0. 001) ,suggesting an evident ovulation-suppressing effect. In 1 monkey, the E2 and P levels were the same before and after insertion,and expulsion of device was found in the monkey later. The plasma LNG concentration in 3 animals was 493. 69-454. 60 pg/ml and plasma LNG was not detected in 1 monkey. The hormone level returned to normal level after removal of the devices.展开更多
Objectives: This study aimed to assess clinical, microbial changes in IUD users and other contraceptive methods in referent to urban health centers in Hamadan city, Iran. Methods: Detailed history and gynecological ex...Objectives: This study aimed to assess clinical, microbial changes in IUD users and other contraceptive methods in referent to urban health centers in Hamadan city, Iran. Methods: Detailed history and gynecological examination were conducted on women (IUD users, n = 100) or other contraceptive methods (controls, n = 160) in the health centers. Results: Frequencies of the different vaginal pathogens, high indices of infection by bacterial vaginosis (12.0%) candida albicance (7.0%) and low indices of trichomoniasis (5.0%) were found in present study, but none of them in both groups was significant. Menorrhagia was more frequent among women with IUD than that among women without IUD (P < 0.05). A trend of erosion cervix and dysmenorrhea being more frequent among women with IUD was also found (P < 0.05). Conclusions: IUD is the safety in general;however, an increase occurred in the frequency of vaginitis.展开更多
Uterine perforation is one of the serious complications associated with use of the intrauterine contraceptive device (IUD). Uterine perforaUon by IUD can involve several neighboring organs. A case of acute appendici...Uterine perforation is one of the serious complications associated with use of the intrauterine contraceptive device (IUD). Uterine perforaUon by IUD can involve several neighboring organs. A case of acute appendicitis was caused by a Multiload Cu 375 TUD inserted previously. This is a rare complication and only fourteen previous cases were recorded in the literature.展开更多
Objective: The purpose of this study was to determine the barriers to intrauterine device (IUD) use at a University-Based Women’s Clinic. Methods: This study is a cross-sectional survey of a convenience sample of sub...Objective: The purpose of this study was to determine the barriers to intrauterine device (IUD) use at a University-Based Women’s Clinic. Methods: This study is a cross-sectional survey of a convenience sample of subjects receiving obstetrical care at a University-Based Women’s Clinic. Eligible women who consented to participate self-administered a 16-question survey during a routine prenatal visit. Descriptive statistics were used to report participants’ demographics and history of contraception use. Additionally, subjects were asked if they would consider IUD use in the future. Results: A total of 160 women participated in this study. The average age of this sample was 24.9 (SD = 6.3). The majority were in low income and low education categories. Only 5% of women reported previous IUD use. 27% of women surveyed desired more information regarding IUD contraception. 19% of participants would consider using an IUD in the future and 25% would consider?IUD in the future if they knew more about them. Insurance and financial constraints were cited as barriers to IUD use. 4% of the sample reported that they had used an IUD previously and were unhappy with it due to pain and discomfort. 18% would not consider an IUD because they had heard about side effects. 68%?of the surveyed sample reported unintended pregnancies. Conclusion: The two most common barriers to IUD use in this patient population was lack of knowledge?and concern about side effects. Increasing patients’ knowledge of IUDs has the potential to increase IUD utilization in this clinic population which reported a 68% rate of unintended pregnancy.展开更多
基金This project was supported by a grant from Hubei Science and Technology Com mittee(No.96 1P190 1)
文摘Effects of two types of intrauterine device (IUD) on the prostaglandins and endothelin (ET) in uterus and on the endometrial morphology in rats and rabbits, and Cu 2+ releasing amounts of both IUDs in vitro were observed. The results showed that the inhibiting action of the indomethacin releasing copper IUD (FICu IUD) on the PGI 2 was stronger than that on the TXA 2, the ratio of 6 keto PGF 1α /TXB 2 was reduced with the increase of the doses. There were significant differences between the groups. The FICu IUD could inhibit the rising of the ET level and lighten the endometrial impairment caused by the FCu IUD, and promote copper ion release. It was suggested that indomethacin released by FICu IUD could effectively reduce abnormal uterine bleeding.
基金This study was supported by National Key Scientific and Technological Project(2004BA720A32)
文摘Objective To compare the cupric ion releasing in vitro o.f the three IUDs. Methods The stability o.f cupric ion releasing o.f IUDs including TCu 380.4 IUD (TCu 380A), Multiload Cu375 IUD (MCu 375) and Yuangong 365 copper-bearing indomethacin-releasing IUD (Yuangong 365) by the determination of cupric ion releasing in simulated uterine fluid. The simulated uterine fluid was used for releasing media. Copper ion was determined by flame atomic absorption spectrometer. Results The cupric ion releasing of three IUDs were instable at the beginning and tend to be stable gradually. In the stable phase, the average level of cupric ion releasing of TCu380A, MCu375 and Yuangong 365 were 4.25±2.71-7.62±6.42 μg, 4.92±1.23 -8.62±3.08 μg and 2.19±0.40-4.68±1.66 μg, respectively. TCu380A had higher instable releasing level than those of Yuangong 365 (P〈0. 05). Conclusion TCu 380.4 and MCu 375 showed a "burst release" during the first few days and the.former was of great significance(P〈0.05). The initial cupric ion releasing of Yuangong 365 appeared to be the lowest, followed by MCu375 and TCu380A in a releasing order
文摘Objective: To assess levonorgestrel-releasing intrauterine system LNG-IUS (Mirena?) application at caesarean section (CS). Design: Randomized, comparative study. Setting: Department of obstetrics and gynecology in a primary reference hospital at Puebla City, Mexico. Sample: 396 women requiring CS signed informed consent and were randomly allocated to the post-placental application of LNG-IUS (198) or Copper T 380 A (198). Methods: Follow up visits at 6 weeks, and 6 and 12 months were performed. Main Outcomes Measures: IUDs expulsion, maternal and babies’ health conditions, breastfeeding and menstrual patterns, adverse effects and pregnancies. Differences between groups were analyzed by Fisher and X2 tests, Odds ratios, relative risk and 95% confidence limits, as appropriate. Results: After one year of follow up, no pregnancies were reported. The IUD expulsion rate was 4.5% in each group. LNG-IUS users had a higher incidence of amenorrhea (OR 2.5 95% CI 2.2 - 3) and menstrual patterns significantly brief and lighter than Copper T 380 A (p < 0.001) with lower incidence of dysmenorrhea (OR 0.1 95% CI 0.04 - 0.2). No detrimental effects of LNG-IUS on breastfeeding was observed and interestingly babies weights of LNG-IUS users was slightly above the average for age compared with Copper T 380 A users. This was probably related with a major proportion of women with normal ferritin serum levels (94% vs 68%) leading to better mother’s general condition. Conclusions: LNG-IUS inserted during CS provides high efficacy contraception with additional benefits, mainly reducing menstrual bleeding and doing so, faster recovery of ferrous homeostasis after CS.
文摘The use of copper-containing intrauterine devices(Cu-IUDs)is a safe,effective,and long-term contraceptive method.Here,we review the effects of Cu-IUDs on subsequent pregnancy and the morphology,local coagulation function,sensitivity to estrogen and progesterone,cell proliferation,and immune response of the endometrium.Studies on the morphology of endometrium indicate that the use of Cu-IUDs can affect the number and binding capacity of estrogen and progesterone receptors in the endometrium and reduce the response of the endometrium to estrogen and progesterone.The use of Cu-IUDs can also affect the proliferation of endometrial cells,suggesting that the aseptic inflammation caused by Cu-IUDs may differ from chronic infectious or noninfectious inflammation;this highlights that the use of Cu-IUDs provides protection against endometrial proliferative diseases.The use of Cu-IUDs increases local endometrial angiogenesis,bleeding tendency,and fibrinolytic activity,which can result in prolonged menstruation or abnormal uterine bleeding.Additionally,the use of Cu-IUDs can cause the infiltration of numerous lymphocytes,monocytes,macrophages,and other inflammatory cells around the endometrial gland and changes in endometrial immune function,immune cell function,and the number and type of immune molecules.Cu-IUD-induced decidual injury significantly increases the invasiveness of trophoblasts,further affecting the aberrant expression of their growth-,angiogenesis-,and invasion-related factors and improving the formation of the placenta.Moreover,the endometrial damage caused by Cu-IUD placement before embryo transfer can improve both clinical pregnancy and live birth rates;however,specific changes in the immune system after Cu-IUD use as well as its effects on future pregnancies require further investigation.
基金supported by Public Service Platform of Science and Technology Projects in Data mining of contraceptives monitoring and research of risk assessment model(BM2012062)the Priority Academic Program Development of Jiangsu Higher Education Institutions
文摘Objective To evaluate the cytotoxicity of six commonly used copper-bearing intrauterine devices (Cu-IUDs) on Chinese hamster ovary (CHO-K1) cells and to investigate the influence of frame, shape and copper surface area of Cu-IUDs on cell toxicity.Methods Cu-IUDs were incubated in 10% FBS-DMEM/F12 culture medium at 37 ℃ for 24 h. The extracts were analyzed by flame atomic absorption spectrometer and were then diluted into different concentrations with culture medium. Finally, cytotoxicity of these original and diluted extracts on CHO-K1 cells was detected by cell counting kit-8 (CCK-8) assay.Results The viabilities of cells treated with the original extracts of six Cu-IUDs (TCu220C bulb, TCu220C, GCu220, GCu300, Yuangong Cu270 and Yuangong Ⅱ- 300) were all below 10% and the cupric ion concentrations in these extracts were 28.22 mg/L, 31.80 mg/L, 92.80 mg/L, 99.74 mg/L, 114.90 mg/L and 119.20 mg/L, respectively. After these original extracts were diluted, significant differences in cytotoxicity were exhibited. IUDs with larger copper surface areas (GCu300 and Yuangong Ⅱ-300) showed more cytotoxicity than those with smaller areas (GCu220 and Yuangong Cu270) respectively; When different shapes of Cu-IUDs were compared, TCu220C bulb showed lower cytotoxicity than TCu220C, and GCu300 exhibited higher toxicity than Yuangong Ⅱ-300; TCu220C displayed significantly lower cytotoxicity than GCu220 due to their differences in frames.Conclusion We presented evidence on the cytotoxic effects of copper ions released from Cu-IUDs on CHO-K1 cells and found that shape, frame together with copper surface area of Cu-IUDs had obvious influence on the cytotoxicity.
文摘A comparative study was made on the contraception efficacy and safety of the vaginal ring releasing 10mg/day Of progesterone in 160 cases and an intrauterine device,the cOPPer T 380A in 100 cases during lactation.It was found that the contraceptive method is acceptable from 42 to 60 days postpartum.No pregnancy occurred in the copper T 380A IUD users during lactation.Those methods are worth to be recommended because of their contraceptive efficacy and no adverse effects on breastfeeding children.Prenatal care and Family Planning Programe are administered together to raise lactation performance rate,and to decrease induced abortion rate,the health of mothers and children were protected.
文摘The purpose of the study was to test the effective period of VCu200 IUD.The concentration of copper ion was measured with non-flame atomic absorption spectrophotometer HITACHI-180.The average concentration of coPPer ion(x±s.)was 2.66±0.58μg/g cervical mucus wet weight(μg/g·M·W·W) in the first year,then gradually decreasing to 0.91±0.16μg/g·M·W·W in the fifteenth-year group of VCu200 IUD.There was an average of 0.35±0.08~0.56±0.14 μg/g·M·W·W in the control group.It showed that the concentration of copper ion was decreasing with prolongation of use of VCu200 IUD and there was statistically significant difference between VCu200 IUD group,on the one hand,and the stainless steel ring group and the control group(P<0.05~0.01)on the other hand.No difference was found between the stainless steel ring group and the control group(P>0.05).It was reported in the literature that the concentration Of copper ion in 1.0μg/ml had the action of antifertility,and it was found that the concentration of copper ion was higher than 1.0μg/ml in the tenth year after insertion of VCu200 IUD.It suggested that effective period of VCu200 IUD was at least ten years.
文摘Since copper has excellent properties such as malleability and conductivity,it is widely used in the electronics field.Copper sulfate plating is expanding further in fields requiring thick deposits such as for heat dissipation boards and bumps for stress relaxation during semiconductor packaging.In this study,high-speed copper plating at 50 A/dm2 or more was achieved using a jet flow device.In addition,as a result of comparison with the low current density film,the current density had little effect on electrical conductivity and film surface structure.On the other hand,it was confirmed that the etching rate of the high current density film was greatly increased as the crystallites on the film surface became smaller than low current density film.Increase in productivity is expected due to shorter plating time enabled by film deposition at high current density.Furthermore,the increase of etching rate is expected to contribute to the suppression of undercuts that occur when removing the seed layer during wiring and bump fabrication.
文摘Objective To explore and investigate a new treatment of releasing the risks and pain in removing intrauterine devices (IUD) from postmenopausal women. Methods Totally 240 postmenopausal women who needed to remove IUD were randomly divided into 3 groups. Group A (n =80) were preoperatively treated with 20 g/L vaginal testosterone propionate cod liver oil ointment (1 g/d) over a 2-week span of period, and vaginal misoprostol (200 μg) was one-time used at 2-3 h before operation. Group B (n =80) were treated with oral estradiol valerate (3 mg/d) from 7 d before operation. Other 80 women (group C) were treated with vaginal cod liver oil ointment (1 g/d) over a 2-week span of period before the operation day. The degree of cervical relaxation, operational difficulty, blood loss volume, the length of operation time and visual analogue scales (VAS) were evaluated, also the serum estradiol, testosterone and endometrial thickness were measured before and after medication. Results The degree of cervical relaxation, operational difficulty, blood loss, the length of operation time and VAS in group A were significantly better than those group C (P〈0.01), whiles its blood loss volume was less than group B (P〈0.05) and there were no significant differences in serum estradiol, testosterone and endometrial thickness before and after medication. Conclusion Preoperative vaginal testosterone propionate combined with misoprostol would reduce the operational difficulties/risks and release the suffering of patients. The study may represent a safe and effective alternative to remove IUD in postmeno- pausal women.
文摘BACKGROUND An intrauterine device(IUD)is a contraceptive device placed in the uterine cavity and is a common contraceptive method for Chinese women.However,an IUD may cause complications due to placement time,intrauterine pressure and other factors.Ectopic IUDs are among the most serious complications.Ectopic IUDs are common in the myometrium and periuterine organs,and there are few reports of ectopic IUDs in the urinary bladder,especially in the anterior wall.CASE SUMMARY A 52-year-old woman was hospitalized due to a urinary bladder foreign body found via abdominal ultrasound and computed tomography(CT)examination.The patient had a 2-year history of recurrent abdominal distension and lower abdominal pain,accompanied by frequent urination,urgency,dysuria and other discomfort.Ultrasound examination revealed foreign bodies in the bladder cavity,with calculus on the surface of the foreign bodies.CT revealed a circular foreign body on the anterior wall of the urinary bladder,suggesting the possibility of an ectopic IUD.After laparoscopic exploration,an annular IUD was found in the anterior wall of urinary bladder,and an oval calculus with a diameter of approximately 2 cm was attached to the surface of the bladder cavity.The IUD and calculus were successfully and completely removed.The patient recovered well after surgery.CONCLUSION Abdominal ultrasound and CT are effective methods for detecting ectopic IUDs.The IUD is located in the urinary bladder and requires early surgical treatment.The choice of surgical method is determined by comprehensively considering the depth of the IUD in the bladder muscle layer,the situation of complicated calculus,the situation of intravesical inflammation and medical technology and equipment.
基金support of National“the eleven-fifth”Project of Ministry of Science and Technology of China(NO.2006BAI13B01).
文摘The purpose of this study was to investigate the effects of copper/low-density polyethylene nanocomposite(nano-Cu/LDPE)on the endometrial angiogenesis in rats,and 100 sexual mature female SD rats were randomly divided into five groups:sham-operation groups(SO group,n=20),bulk copper groups(Cu group,n=20),LDPE groups(n=20),nano-Cu/LDPE groups I(n=20)and II(n=20).The levels of angiopoietin-2(Ang-2),its receptor(Tie-2)and CD34 of the rats’endometria in each group were examined by using the S-P method of the immunohistochemistry 30 and 180 days after insertion,respectively.Compared with those in the SO group,the expression of Ang-2 and Tie-2 in all the experimental groups was obviously increased 30 days after insertion,and these parameters in nano-Cu/LDPE groups,except for Ang-2 level in nano-Cu/LDPE group II,were significantly lower in comparison with those in Cu group(P<0.05).On the 180th day after insertion,Ang-2 and Tie-2 levels were still higher in Cu group and LDPE group,but there was no difference of Ang-2 and Tie-2 levels between nano-Cu/LDPE groups and the SO group(P>0.05).Com-pared with those in the SO group,the significant increases in microvessel density(MVD)were observed on the 30th and the 180th day after the insertion of the bulk copper(P<0.05).There was no significant difference in MVD counts before and after the insertion of nano-Cu/LDPE(P>0.05).The results show that Nano-Cu/LDPE have slighter influence on the endometrial angiogenesis than bulk copper.
文摘BACKGROUND Levonorgestrel-releasing intrauterine systems(LNG-IUSs)gradually release levonorgestrel into the uterus and is effective against hypermenorrhoea and dysmenorrhea.Complications associated with the insertion include expulsion,displacement,and uterine perforation.Ultrasonic identification of copper intrauterine devices(IUDs)is possible due to echogenicity from the copper coils.However,the barium sulfate coatings of LNG-IUSs do not always provide hyperechoic images.Both barium sulfate and copper are radiopaque and clearly identifiable on X-ray.Thus,X-ray imaging is required to locate LNG-IUSs.CASE SUMMARY A 46-year-old woman with hypermenorrhoea due to submucosal myomas was treated with LNG-IUS at another hospital.Three LNG-IUS insertions had apparently been followed by spontaneous expulsion,although objective confirmation using imaging was not performed.The patient was referred to our institution for surgery.At the first visit,there appeared to be no device in the uterus,and none was observed on transvaginal ultrasound.However,two LNGIUSs were observed in the pelvis on abdominal plain X-rays prior to surgery.Hysteroscopic myomectomy was performed,and the two LNG-IUSs were found to have perforated the myometrium.The devices were safely removed during surgery,and the submucosal myomas were also removed.The perforated section of the myometrium was minimal+ADs-therefore,a repair operation was not required.CONCLUSION Plain abdominal X-rays facilitate the determination of whether an LNG-IUS is in the uterine cavity.Therefore,it is important to confirm a device’s location,regardless of whether spontaneous expulsion is suspected,prior to inserting another device.
文摘Three hundred and eighty four women in Shanghai who delivered vaginally and chose IUD for contraception received the copper T 380A IUD inserted vaginally within 10 min after delivery of the placenta(i.e.,immediate postplacental insertion, IPPI). Among them, 98.70% were primipara. The women were randomly divided into two groups: IUD inserted by hand and IUD insreted by ring forceps. Using Life Table Method and χ 2 test, expulsion and other discontinuation rates were compared at 6, 12, 24, and 36 months post insertion between these two different groups. No uterine perforation, infection or prolonged period of lochia occurred in the 384 cases. Expulsions were the main reason for discontinuation. From 6 months to 36 months, the gross cumulative rates of all discontinuation events (expulsion, pregnancy, removal for bleeding/pain, etc.) were not statistically significantly different (P>0.05). The results suggest that these two different insertion techniques do not significantly affect discontinuation rate in vaginal IPPI using the TCu 380 A, which appears to be suitable for postpartum insertion in Chinese women. Other relevant issues, such as breast feeding and IUD position in uterine cavity, are also analyzed and discussed in this paper.
文摘AIM: To review the safety (infection, perforation) and efficacy (expulsion, continuation rates, pregnancy) of intrauterine device (IUD) insertion in the postpartum period. METHODS: MEDLINE, PubMed and Google Scholar were searched for randomized controlled trials and prospective cohort studies of IUD insertions at different times during the postpartum period. Time of insertion during the postpartum period was documented speci-fically, immediate post placenta period (within 10 min), early post placenta period (10 min to 72 h), and de-layed/interval period (greater than 6 wk). Other study variables included mode of delivery, vaginal vs cesarean, manual vs use of ring forceps to insert the IUD. RESULTS: IUD insertion in the immediate postpartum (within 10 min of placental delivery), early postpartum (10 min up to 72 h) and Interval/Delayed (6 wk onward) were found to be safe and effcacious. Expulsion rates were found to be highest in the immediate postpartum groups ranging from 14% to 27%. Immediate post placental insertion found to have expulsion rates that ranged from 3.6% to 16.2%. Expulsion rate was significantly higher after insertion following vaginal vs cesarean delivery. The rates of infection, perforation and unplanned pregnancy following postpartum IUD insertion are low. Method of insertion such as with ring forceps, by hand, or another placement method unique to the type of IUD did not show any signifcant difference in expulsion rates. Uterine perforations are highest in the delayed/interval IUD insertion groups.Breastfeeding duration and infant development are not affected by delayed/interval insertion of the non-hormonal (copper) IUD or the Levonorgestrel IUD. Timing of the Levonorgestrel IUD insertion may affect breastfeeding. CONCLUSION: IUD insertion is safe and efficacious during the immediate postpartum, early postpartum and delayed postpartum periods. Expulsion rates are highest after vaginal delivery and when inserted during the immediate postpartum period. IUD associated infection rates were not increased by insertion during the postpartum period over interval insertion rates. There is no evidence that breastfeeding is negatively affected by postpartum insertion of copper or hormone-secreting IUD. Although perforation rates were higher when inserted after lactation was initiated. Randomized controlled trials are needed to further elucidate the consequence of lactation on postpartum insertion. Despite the concerns regarding expulsion, perforation and breastfeeding, current evidence indicates that a favorable risk beneft ratio in support of postpartum IUD insertion. This may be particularly relevant for women for whom barriers exist in achieving desired pregnancy spacing.
文摘BACKGROUND A cystic lesion arising from the myometrium of the uterus, termed as cystic adenomyosis, has chocolate-like, thick viscous contents and contains various amounts of endometrial stroma below the glandular epithelium. It is an extremely rare type of adenomyosis.CASE SUMMARY Herein, we report an unusual case of a giant cystic mass in the pelvic cavity after uterine myomectomy. The patient complained of abnormal uterine bleeding and severe dysmenorrhea. After a levonorgestrel-containing intrauterine device(LNG-IUD) was inserted, her symptoms were greatly alleviated. However, the LNG-IUD was detected in the cystic cavity during the follow-up. For fear of the intrauterine device migrating into and damaging the surrounding viscera,surgical treatment was proposed. Therefore, laparoscopic resection of the lesion and removal of the LNG-IUD were performed and cystic adenomyosis with an LNG-IUD out of the uterine cavity was diagnosed.CONCLUSION We believe that myomectomy breaking through the endometrial cavity may have been a predisposing factor for the development of cystic adenomyosis in this case.
文摘BACKGROUND An intrauterine device(IUD)is a commonly used contraceptive among women in China.It is widely used because it is safe,effective,simple,economic,and reversible.Among the possible complications,an ectopic IUD in the bladder is rare.It occurs insidiously,has a long course,is associated with a high risk for injury,and is difficult to treat.CASE SUMMARY A 44-year-old woman was admitted for repeated episodes of urinary frequency,urgency,and dysuria over three months.Laboratory tests revealed significantly elevated urine leukocytes and bacteria.Urine culture suggested colonization with Enterococcus faecalis.Abdominal computed tomography images suggested an abnormally positioned IUD that was protruding into the bladder.Cystoscopy revealed a metallic foreign body with multiple stones on its surface in the left posterior bladder wall.The foreign body measured approximately 1 cm.Hysteroscopy revealed the arm of a V-type metal IUD embedded in the middle and upper sections of the anterior wall of the cervical canal.The majority of the IUD was located in the uterine cavity.Cystoscopy was performed,and a holmium laser was utilized to break the stones attached to the portion of the IUD in the bladder.The IUD was then removed through hysteroscopy.CONCLUSION Ectopic IUDs in the bladder can be diagnosed with thorough imaging and safely removed through cystoscopy or hysteroscopy.
文摘Effect of domestically-made levonorgestrel-releasing intrauterine device (LNG, release rate: 6 μg/day) on the endocrine system and menstruation in mondeys was investigated. The results showed that the Estradiol (E2) and progesterone (P) levels were significantly decreased 2 ovulatory cycles after iusertion of the devices as compared with those before insertion in 3 monkeys (P>0. 001) ,suggesting an evident ovulation-suppressing effect. In 1 monkey, the E2 and P levels were the same before and after insertion,and expulsion of device was found in the monkey later. The plasma LNG concentration in 3 animals was 493. 69-454. 60 pg/ml and plasma LNG was not detected in 1 monkey. The hormone level returned to normal level after removal of the devices.
文摘Objectives: This study aimed to assess clinical, microbial changes in IUD users and other contraceptive methods in referent to urban health centers in Hamadan city, Iran. Methods: Detailed history and gynecological examination were conducted on women (IUD users, n = 100) or other contraceptive methods (controls, n = 160) in the health centers. Results: Frequencies of the different vaginal pathogens, high indices of infection by bacterial vaginosis (12.0%) candida albicance (7.0%) and low indices of trichomoniasis (5.0%) were found in present study, but none of them in both groups was significant. Menorrhagia was more frequent among women with IUD than that among women without IUD (P < 0.05). A trend of erosion cervix and dysmenorrhea being more frequent among women with IUD was also found (P < 0.05). Conclusions: IUD is the safety in general;however, an increase occurred in the frequency of vaginitis.
文摘Uterine perforation is one of the serious complications associated with use of the intrauterine contraceptive device (IUD). Uterine perforaUon by IUD can involve several neighboring organs. A case of acute appendicitis was caused by a Multiload Cu 375 TUD inserted previously. This is a rare complication and only fourteen previous cases were recorded in the literature.
文摘Objective: The purpose of this study was to determine the barriers to intrauterine device (IUD) use at a University-Based Women’s Clinic. Methods: This study is a cross-sectional survey of a convenience sample of subjects receiving obstetrical care at a University-Based Women’s Clinic. Eligible women who consented to participate self-administered a 16-question survey during a routine prenatal visit. Descriptive statistics were used to report participants’ demographics and history of contraception use. Additionally, subjects were asked if they would consider IUD use in the future. Results: A total of 160 women participated in this study. The average age of this sample was 24.9 (SD = 6.3). The majority were in low income and low education categories. Only 5% of women reported previous IUD use. 27% of women surveyed desired more information regarding IUD contraception. 19% of participants would consider using an IUD in the future and 25% would consider?IUD in the future if they knew more about them. Insurance and financial constraints were cited as barriers to IUD use. 4% of the sample reported that they had used an IUD previously and were unhappy with it due to pain and discomfort. 18% would not consider an IUD because they had heard about side effects. 68%?of the surveyed sample reported unintended pregnancies. Conclusion: The two most common barriers to IUD use in this patient population was lack of knowledge?and concern about side effects. Increasing patients’ knowledge of IUDs has the potential to increase IUD utilization in this clinic population which reported a 68% rate of unintended pregnancy.