The probability-assessment analyses on the characteristic value of voltage dip by using Monte Carlo stochastic modeling method to stimulate the randomness of the short circuit fault are introduced. Using Matlab and Po...The probability-assessment analyses on the characteristic value of voltage dip by using Monte Carlo stochastic modeling method to stimulate the randomness of the short circuit fault are introduced. Using Matlab and Power Systems CAD(PSCAD), we design control interface which combines the electromagnetic transient simulation with the Monte Carlo method. Specifically, the designing of interface which is meant to employ the method of Matlab programming to control the electromagnetic transients including direct current(EMTDC)simulation is introduced. Furthermore, the influences of the protection devices on the voltage dip to ensure the authenticity and the referential reliability are simulated. A system with the inverse-time protection devices equipped on each line which can coordinate together is designed to cut off the short-circuit fault. The voltage dip of the designed system is assessed by the pre- and post-system average root mean square(RMS) variation frequency index, and the voltage dip index is compared with the Information Technology Industry Council(ITIC)curves. The simulation results demonstrate that the inverse-time relay protection equipments are well-coordinated,and the severity and the range of the voltage dip are influenced by the cooperation of the equipped inverse-time protection devices.展开更多
Symmetrical components method is employed in analysis of the characteristic motor faults.Motor protection method is put forward based on detecting positive sequence,negative sequence and zero sequence current.And prob...Symmetrical components method is employed in analysis of the characteristic motor faults.Motor protection method is put forward based on detecting positive sequence,negative sequence and zero sequence current.And problems of lack of motor overload capacity in existing mining motor protection system,impact of dynamic current on stage and definite-time delay operation and inaccuracy of criterion phase failure protection are analyzed.The unbalanced faults protection and inverse-time overload protection,which can make protection time change with the current movement,are proposed.The above problems can be solved,and the reliability and intelligent of coal shearer are improved.展开更多
基金the Henan Tackle Key Problem of Science and Technology(No.102102210454)the Foundation of Education Committee of Henan Province(No.2011B520028)
文摘The probability-assessment analyses on the characteristic value of voltage dip by using Monte Carlo stochastic modeling method to stimulate the randomness of the short circuit fault are introduced. Using Matlab and Power Systems CAD(PSCAD), we design control interface which combines the electromagnetic transient simulation with the Monte Carlo method. Specifically, the designing of interface which is meant to employ the method of Matlab programming to control the electromagnetic transients including direct current(EMTDC)simulation is introduced. Furthermore, the influences of the protection devices on the voltage dip to ensure the authenticity and the referential reliability are simulated. A system with the inverse-time protection devices equipped on each line which can coordinate together is designed to cut off the short-circuit fault. The voltage dip of the designed system is assessed by the pre- and post-system average root mean square(RMS) variation frequency index, and the voltage dip index is compared with the Information Technology Industry Council(ITIC)curves. The simulation results demonstrate that the inverse-time relay protection equipments are well-coordinated,and the severity and the range of the voltage dip are influenced by the cooperation of the equipped inverse-time protection devices.
文摘Symmetrical components method is employed in analysis of the characteristic motor faults.Motor protection method is put forward based on detecting positive sequence,negative sequence and zero sequence current.And problems of lack of motor overload capacity in existing mining motor protection system,impact of dynamic current on stage and definite-time delay operation and inaccuracy of criterion phase failure protection are analyzed.The unbalanced faults protection and inverse-time overload protection,which can make protection time change with the current movement,are proposed.The above problems can be solved,and the reliability and intelligent of coal shearer are improved.