期刊文献+
共找到29,520篇文章
< 1 2 250 >
每页显示 20 50 100
Review of Fault-tolerant Control for Motor Inverter Failure with Operational Quality Considered
1
作者 Yuxuan Du Wenxiang Zhao +2 位作者 Yihua Hu Jinghua Ji Tao Tao 《CES Transactions on Electrical Machines and Systems》 EI CSCD 2024年第2期202-215,共14页
In recent years,motor drive systems have garnered increasing attention due to their high efficiency and superior control performance.This is especially apparent in aerospace,marine propulsion,and electric vehicles,whe... In recent years,motor drive systems have garnered increasing attention due to their high efficiency and superior control performance.This is especially apparent in aerospace,marine propulsion,and electric vehicles,where high performance,efficiency,and reliability are crucial.The ability of the drive system to maintain long-term fault-tolerant control(FTC)operation after a failure is essential.The likelihood of inverter failures surpasses that of other components in the drive system,highlighting its critical importance.Long-term FTC operation ensures the system retains its fundamental functions until safe repairs or replacements can be made.The focus of developing a FTC strategy has shifted from basic FTC operations to enhancing the post-fault quality to accommodate the realities of prolonged operation post-failure.This paper primarily investigates FTC strategies for inverter failures in various motor drive systems over the past decade.These strategies are categorized into three types based on post-fault operational quality:rescue,remedy,and reestablishment.The paper discusses each typical control strategy and its research focus,the strengths and weaknesses of various algorithms,and recent advancements in FTC.Finally,this review summarizes effective FTC techniques for inverter failures in motor drive systems and suggests directions for future research. 展开更多
关键词 FAULT-TOLERANT Motor drive Operation quality inverter failure
下载PDF
Review of Three-phase Soft Switching Inverters and Challenges for Motor Drives
2
作者 Haifeng Lu Qiao Wang +1 位作者 Jianyun Chai Yongdong Li 《CES Transactions on Electrical Machines and Systems》 EI CSCD 2024年第2期177-190,共14页
For electric vehicles (EVs),it is necessary to improve endurance mileage by improving the efficiency.There exists a trend towards increasing the system voltage and switching frequency,contributing to improve charging ... For electric vehicles (EVs),it is necessary to improve endurance mileage by improving the efficiency.There exists a trend towards increasing the system voltage and switching frequency,contributing to improve charging speed and power density.However,this trend poses significant challenges for high-voltage and high-frequency motor controllers,which are plagued by increased switching losses and pronounced switching oscillations as consequences of hard switching.The deployment of soft switching technology presents a viable solution to mitigate these issues.This paper reviews the applications of soft switching technologies for three-phase inverters and classifies them based on distinct characteristics.For each type of inverter,the advantages and disadvantages are evaluated.Then,the paper introduces the research progress and control methods of soft switching inverters (SSIs).Moreover,it presents a comparative analysis among the conventional hard switching inverters (HSIs),an active clamping resonant DC link inverter (ACRDCLI) and an auxiliary resonant commuted pole inverter (ARCPI).Finally,the problems and prospects of soft switching technology applied to motor controllers for EVs are put forward. 展开更多
关键词 Soft switching inverters Zero-voltage switching Electric vehicles Motor drives
下载PDF
Adaptive Predefined-Time Backstepping Control for Grid Connected Photovoltaic Inverter
3
作者 Jiarui Zhang Dan Liu +4 位作者 Kan Cao Ping Xiong Xiaotong Ji Yanze Xu Yunfei Mu 《Energy Engineering》 EI 2024年第8期2065-2083,共19页
The system performance of grid-connected photovoltaic(PV)has a serious impact on the grid stability.To improve the control performance and shorten the convergence time,a predefined-time controller based on backsteppin... The system performance of grid-connected photovoltaic(PV)has a serious impact on the grid stability.To improve the control performance and shorten the convergence time,a predefined-time controller based on backstepping technology and dynamic surface control is formulated for the inverter in the grid-connected photovoltaic.The time-varying tuning functions are introduced into state-tracking errors to realize the predefined-time control effect.To address the“computational explosion problem”in the design process of backstepping control,dynamic surface control is adopted to avoid the analytical calculations of virtual control.The disturbances of the PV system are estimated and compensated by adaptive laws.The control parameters are chosen and the global stability of the closed-loop is ensured by Lyapunov conditions.Simulation results confirm the effectiveness of the proposed controller and ensure the predefined time control in the photovoltaic inverter. 展开更多
关键词 Photovoltaic inverter system backstepping technology predefined-time control adaptive control
下载PDF
A novel cascaded H-bridge photovoltaic inverter with flexible arc suppression function
4
作者 Junyi Tang Wei Gao 《Global Energy Interconnection》 EI CSCD 2024年第4期513-527,共15页
This paper presents a novel approach that simultaneously enables photovoltaic(PV)inversion and flexible arc suppression during single-phase grounding faults.Inverters compensate for ground currents through an arc-elim... This paper presents a novel approach that simultaneously enables photovoltaic(PV)inversion and flexible arc suppression during single-phase grounding faults.Inverters compensate for ground currents through an arc-elimination function,while outputting a PV direct current(DC)power supply.This method effectively reduces the residual grounding current.To reduce the dependence of the arc-suppression performance on accurate compensation current-injection models,an adaptive fuzzy neural network imitating a sliding mode controller was designed.An online adaptive adjustment law for network parameters was developed,based on the Lyapunov stability theorem,to improve the robustness of the inverter to fault and connection locations.Furthermore,a new arc-suppression control exit strategy is proposed to allow a zerosequence voltage amplitude to quickly and smoothly track a target value by controlling the nonlinear decrease in current and reducing the regulation time.Simulation results showed that the proposed method can effectively achieve fast arc suppression and reduce the fault impact current in single-phase grounding faults.Compared to other methods,the proposed method can generate a lower residual grounding current and maintain good arc-suppression performance under different transition resistances and fault locations. 展开更多
关键词 Photovoltaic inverter Flexible arc suppression Adaptive control Fuzzy neural network Sliding mode control Exit strategy
下载PDF
Integration of a Fault-Tolerant H-Bridge Inverter into the Photovoltaic System for DC-AC Conversion of Electrical Energy
5
作者 Dobsoumna Emmanuel Djondiné Philippe +2 位作者 Issa Dieudonné Douniya Edouard Ronwé Djorwé Frédéric 《Journal of Energy and Power Engineering》 CAS 2024年第3期93-103,共11页
The photovoltaic system is experiencing great growth in the production of electrical energy these days.It plays a vital role in the production of electrical energy in isolated towns.It is generally either stand-alone ... The photovoltaic system is experiencing great growth in the production of electrical energy these days.It plays a vital role in the production of electrical energy in isolated towns.It is generally either stand-alone or connected to a network.The energy produced by the photovoltaic generator is in continuous form;the conversion from its continuous form to the alternating form requires a converter:the inverter.In order to improve the quality of the waveform,we moved from the classic solar inverter to multilevel inverters.These multilevel inverters are equipped with power switches which are required to withstand strong fluctuations in the voltage produced by the GPV(photovoltaic generator).It is obvious that the degradation of the inverter leads to a distortion of the wave quality.This article presents the simulation of the GPV-Chopper Boost-Inverter chain in fault-tolerant cascaded H-bridges in order to overcome the difficulties of voltage constraints experienced by power switches(IGBT:insulated gate bipolar transistor).The results of simulations carried out in Matlab/Simulink show good performance of the designed inverter model. 展开更多
关键词 Photovoltaic generator boost chopper FAULT-TOLERANT H-bridge inverter GPV-chopper
下载PDF
An Algorithm for Short-Circuit Current Interval in Distribution Networks with Inverter Type Distributed Generation Based on Affine Arithmetic
6
作者 Yan Zhang Bowen Du +3 位作者 Benren Pan GuannanWang Guoqiang Xie Tong Jiang 《Energy Engineering》 EI 2024年第7期1903-1920,共18页
During faults in a distribution network,the output power of a distributed generation(DG)may be uncertain.Moreover,the output currents of distributed power sources are also affected by the output power,resulting in unc... During faults in a distribution network,the output power of a distributed generation(DG)may be uncertain.Moreover,the output currents of distributed power sources are also affected by the output power,resulting in uncertainties in the calculation of the short-circuit current at the time of a fault.Additionally,the impacts of such uncertainties around short-circuit currents will increase with the increase of distributed power sources.Thus,it is very important to develop a method for calculating the short-circuit current while considering the uncertainties in a distribution network.In this study,an affine arithmetic algorithm for calculating short-circuit current intervals in distribution networks with distributed power sources while considering power fluctuations is presented.The proposed algorithm includes two stages.In the first stage,normal operations are considered to establish a conservative interval affine optimization model of injection currents in distributed power sources.Constrained by the fluctuation range of distributed generation power at the moment of fault occurrence,the model can then be used to solve for the fluctuation range of injected current amplitudes in distributed power sources.The second stage is implemented after a malfunction occurs.In this stage,an affine optimization model is first established.This model is developed to characterizes the short-circuit current interval of a transmission line,and is constrained by the fluctuation range of the injected current amplitude of DG during normal operations.Finally,the range of the short-circuit current amplitudes of distribution network lines after a short-circuit fault occurs is predicted.The algorithm proposed in this article obtains an interval range containing accurate results through interval operation.Compared with traditional point value calculation methods,interval calculation methods can provide more reliable analysis and calculation results.The range of short-circuit current amplitude obtained by this algorithm is slightly larger than those obtained using the Monte Carlo algorithm and the Latin hypercube sampling algorithm.Therefore,the proposed algorithm has good suitability and does not require iterative calculations,resulting in a significant improvement in computational speed compared to the Monte Carlo algorithm and the Latin hypercube sampling algorithm.Furthermore,the proposed algorithm can provide more reliable analysis and calculation results,improving the safety and stability of power systems. 展开更多
关键词 Short circuit calculation inverter type distributed power supplies affine arithmetic distribution network
下载PDF
Reducing Condensation Inside the Photovoltaic(PV)Inverter according to the Effect of Diffusion as a Process of Vapor Transport
7
作者 Amal El Berry Marwa M.Ibrahim +1 位作者 A.A.Elfeky Mohamed F.Nasr 《Frontiers in Heat and Mass Transfer》 EI 2024年第4期1189-1207,共19页
A photovoltaic(PV)inverter is a vital component of a photovoltaic(PV)solar system.Photovoltaic(PV)inverter failure can mean a solar system that is no longer functioning.When electronic devices such as photovoltaic(PV)... A photovoltaic(PV)inverter is a vital component of a photovoltaic(PV)solar system.Photovoltaic(PV)inverter failure can mean a solar system that is no longer functioning.When electronic devices such as photovoltaic(PV)inverter devices are subjected to vapor condensation,a risk could occur.Given the amount of moisture in the air,saturation occurswhen the temperature drops to the dewpoint,and condensationmay formon surfaces.Numerical simulation with“COMSOL Software”is important for obtaining knowledge relevant to preventing condensation by using two steps.At first,the assumption was that the device’s water vapor concentration was homogeneous to evaluate the amount of liquid water accumulated on the internal walls of the photovoltaic(PV)inverter box.Second,by considering the effect of external wind velocity onmoisture transport at the air interface to evaluate water vapor transport outdoors and reduce condensation.General factorial designs are utilized for analyzing the nature of the relationship between the vapor condensation response and the variables.Reducing vapor condensation inside the solar inverter by the effect of external wind speed on diffusion as a process of transporting moister air outside the inverter box is the main solution for this problem.During the movement and assessment of the flow of water vapor,the impact of vapor condensation is reduced.The saturation period was determined by using a Boolean saturation indicator.The saturation indicator was set to 1 when saturation was detected(relative humidity greater than or equal to 1)and 0 otherwise.Calculating the flow and dispersion of moist air as a function of wind speed helped solve the problem. 展开更多
关键词 PHOTOVOLTAIC inverter failure vapor condensation wind velocity diffusion transport and general factorial
下载PDF
Estimating the Input Power of a Power Plant Using the Efficiency of the Inverter
8
作者 Toussaint Tilado Guingane Sosthène Tassembedo +3 位作者 Eric Korsaga Dominique Bonkoungou Zacharie Koalaga François Zougmore 《Smart Grid and Renewable Energy》 2024年第3期99-106,共8页
The study focuses on estimating the input power of a power plant from available data, using the theoretical inverter efficiency as the key parameter. The paper addresses the problem of missing data in power generation... The study focuses on estimating the input power of a power plant from available data, using the theoretical inverter efficiency as the key parameter. The paper addresses the problem of missing data in power generation systems and proposes an approach based on the efficiency formula widely documented in the literature. In the absence of input data, this method makes it possible to estimate the plant’s input power using data extracted from the site, in particular that provided by the Ministry of the Environment. The importance of this study lies in the need to accurately determine the input power in order to assess the overall performance of the energy system. 展开更多
关键词 Estimation Data MISSING INPUT POWER EFFICIENCY inverter
下载PDF
Coordinated Capacitor Voltage Balancing Method for Cascaded H-bridge Inverter with Supercapacitor and DC-DC Stage
9
作者 Ye Zhang Zixin Li +2 位作者 Fanqiang Gao Cong Zhao Yaohua Li 《CES Transactions on Electrical Machines and Systems》 EI CSCD 2024年第2期191-201,共11页
Cascaded H-bridge inverter(CHBI) with supercapacitors(SCs) and dc-dc stage shows significant promise for medium to high voltage energy storage applications. This paper investigates the voltage balance of capacitors wi... Cascaded H-bridge inverter(CHBI) with supercapacitors(SCs) and dc-dc stage shows significant promise for medium to high voltage energy storage applications. This paper investigates the voltage balance of capacitors within the CHBI, including both the dc-link capacitors and SCs. Balance control over the dc-link capacitor voltages is realized by the dcdc stage in each submodule(SM), while a hybrid modulation strategy(HMS) is implemented in the H-bridge to balance the SC voltages among the SMs. Meanwhile, the dc-link voltage fluctuations are analyzed under the HMS. A virtual voltage variable is introduced to coordinate the balancing of dc-link capacitor voltages and SC voltages. Compared to the balancing method that solely considers the SC voltages, the presented method reduces the dc-link voltage fluctuations without affecting the voltage balance of SCs. Finally, both simulation and experimental results verify the effectiveness of the presented method. 展开更多
关键词 Cascaded H-bridge inverter(CHBI) Hybrid modulation strategy(HMS) Capacitor voltage balancing DClink voltage fluctuation Supercapacitor(SC)
下载PDF
Model Predictive Control for Cascaded H-Bridge PV Inverter with Capacitor Voltage Balance
10
作者 Xinwei Wei Wanyu Tao +4 位作者 Xunbo Fu Xiufeng Hua Zhi Zhang Xiaodan Zhao Chen Qin 《Journal of Electronic Research and Application》 2024年第2期79-85,共7页
We designed an improved direct-current capacitor voltage balancing control model predictive control(MPC)for single-phase cascaded H-bridge multilevel photovoltaic(PV)inverters.Compared with conventional voltage balanc... We designed an improved direct-current capacitor voltage balancing control model predictive control(MPC)for single-phase cascaded H-bridge multilevel photovoltaic(PV)inverters.Compared with conventional voltage balanc-ing control methods,the method proposed could make the PV strings of each submodule operate at their maximum power point by independent capacitor voltage control.Besides,the predicted and reference value of the grid-connected current was obtained according to the maximum power output of the maximum power point tracking.A cost function was con-structed to achieve the high-precision grid-connected control of the CHB inverter.Finally,the effectiveness of the proposed control method was verified through a semi-physical simulation platform with three submodules. 展开更多
关键词 Model predictive control(MPC) Photovoltaic system Cascaded H-bridge(CHB)inverter Capacitor voltage balance
下载PDF
Effect of temperature on heavy ion-induced single event transient on 16-nm FinFET inverter chains
11
作者 蔡莉 池雅庆 +10 位作者 叶兵 刘郁竹 贺泽 王海滨 孙乾 孙瑞琪 高帅 胡培培 闫晓宇 李宗臻 刘杰 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第4期504-510,共7页
The variations of single event transient(SET)pulse width of high-LET heavy ion irradiation in 16-nm-thick bulk silicon fin field-effect transistor(Fin FET)inverter chains with different driven strengths are measured a... The variations of single event transient(SET)pulse width of high-LET heavy ion irradiation in 16-nm-thick bulk silicon fin field-effect transistor(Fin FET)inverter chains with different driven strengths are measured at different temperatures.Three-dimensional(3D)technology computer-aided design simulations are carried out to study the SET pulse width and saturation current varying with temperature.Experimental and simulation results indicate that the increase in temperature will enhance the parasitic bipolar effect of bulk Fin FET technology,resulting in the increase of SET pulse width.On the other hand,the increase of inverter driven strength will change the layout topology,which has a complex influence on the SET temperature effects of Fin FET inverter chains.The experimental and simulation results show that the device with the strongest driven strength has the least dependence on temperature. 展开更多
关键词 heavy ion single event effect single event transient Fin FET inverter chain
下载PDF
Improved Control in Single Phase Inverter Grid-Tied PV System Using Modified PQ Theory
12
作者 Nur Fairuz Mohamed Yusof Dahaman Ishak +3 位作者 Muhammad Ammirrul Atiqi Mohd Zainuri Muhammad Najwan Hamidi Zuhair Muhammed Alaas Mohamed Mostafa Ramadan Ahmed 《Intelligent Automation & Soft Computing》 SCIE 2023年第8期2441-2457,共17页
Grid-connected reactive-load compensation and harmonic control are becoming a central topic as photovoltaic(PV)grid-connected systems diversified.This research aims to produce a high-performance inverter with a fast d... Grid-connected reactive-load compensation and harmonic control are becoming a central topic as photovoltaic(PV)grid-connected systems diversified.This research aims to produce a high-performance inverter with a fast dynamic response for accurate reference tracking and a low total har-monic distortion(THD)even under nonlinear load applications by improving its control scheme.The proposed system is expected to operate in both stand-alone mode and grid-connected mode.In stand-alone mode,the proposed controller supplies power to critical loads,alternatively during grid-connected mode provide excess energy to the utility.A modified variable step incremental conductance(VS-InCond)algorithm is designed to extract maximum power from PV.Whereas the proposed inverter controller is achieved by using a modified PQ theory with double-band hysteresis current controller(PQ-DBHCC)to produce a reference current based on a decomposition of a single-phase load current.The nonlinear rectifier loads often create significant distortion in the output voltage of single-phase inverters,due to excessive current harmonics in the grid.Therefore,the proposed method generates a close-loop reference current for the switching scheme,hence,minimizing the inverter voltage distortion caused by the excessive grid current harmonics.The simulation findings suggest the proposed control technique can effectively yield more than 97%of power conversion efficiency while suppressing the grid current THD by less than 2%and maintaining the unity power factor at the grid side.The efficacy of the proposed controller is simulated using MATLAB/Simulink. 展开更多
关键词 Hysteresis current controller incremental conductance nonlinear load PQ theory single-phase inverter
下载PDF
Parameter Design of Current Double Closed Loop for T-Type Three-Level Grid-Connected Inverter
13
作者 Tiankui Sun Mingming Shi +3 位作者 Xiaolong Xiao Ping He Yu Ji Zhiyuan Yuan 《Energy Engineering》 EI 2023年第7期1621-1636,共16页
To reduce current harmonics caused by switching frequency,T-type grid-connected inverter topology with LCL filter is adopted.In view of the disadvantages of the slow response speed of the traditional current control a... To reduce current harmonics caused by switching frequency,T-type grid-connected inverter topology with LCL filter is adopted.In view of the disadvantages of the slow response speed of the traditional current control and the failure to eliminate the influence of the LCL filter on the grid-connected current by using current PI control alone,a current double closed loop PI current tracking control is proposed.Through the theoretical analysis of the grid-connected inverter control principle,the grid-connected inverter control model is designed,and the transfer functionmodel of each control link is deduced,and the current loop PI regulator is designed at last.The simulation results show that the control strategy is feasible. 展开更多
关键词 T-type inverter active damping current double closed loop
下载PDF
Genetic Algorithm Based 7-Level Step-Up Inverter with Reduced Harmonics and Switching Devices
14
作者 T.Anand Kumar M.Kaliamoorthy I.Gerald Christopher Raj 《Intelligent Automation & Soft Computing》 SCIE 2023年第3期3081-3097,共17页
This paper presents a unique voltage-raising topology for a single-phase seven-level inverter with triple output voltage gain using single input source and two switched capacitors.The output voltage has been boosted u... This paper presents a unique voltage-raising topology for a single-phase seven-level inverter with triple output voltage gain using single input source and two switched capacitors.The output voltage has been boosted up to three times the value of input voltage by configuring the switched capacitors in series and parallel combinations which eliminates the use of additional step-up converters and transformers.The selective harmonic elimination(SHE)approach is used to remove the lower-order harmonics.The optimal switching angles for SHE is determined using the genetic algorithm.These switching angles are com-bined with a level-shifted pulse width modulation(PWM)technique for pulse generation,resulting in reduced total harmonic distortion(THD).A detailed com-parison has been made against other relevant seven-level inverter topologies in terms of the number of switches,drivers,diodes,capacitors,and boosting facil-ities to emphasize the benefits of the proposed model.The proposed topology is simulated using MATLAB/SIMULINK and an experimental prototype has been developed to validate the results.The Digital Signal Processing(DSP)TMS320F2812 board is used to generate the switching pulses for the proposed technique and the experimental results concur with the simulated model outputs. 展开更多
关键词 Genetic algorithm multilevel inverter pulse width modulation selective harmonic elimination switched capacitor
下载PDF
Research on Mixed Logic Dynamic Modeling and Finite Control Set Model Predictive Control of Multi-Inverter Parallel System
15
作者 Xiaojuan Lu Mengqiao Chen Qingbo Zhang 《Energy Engineering》 EI 2023年第3期649-664,共16页
Parallel connection of multiple inverters is an important means to solve the expansion,reserve and protection of distributed power generation,such as photovoltaics.In view of the shortcomings of traditional droop cont... Parallel connection of multiple inverters is an important means to solve the expansion,reserve and protection of distributed power generation,such as photovoltaics.In view of the shortcomings of traditional droop control methods such as weak anti-interference ability,low tracking accuracy of inverter output voltage and serious circulation phenomenon,a finite control set model predictive control(FCS-MPC)strategy of microgrid multiinverter parallel system based on Mixed Logical Dynamical(MLD)modeling is proposed.Firstly,the MLD modeling method is introduced logical variables,combining discrete events and continuous events to form an overall differential equation,which makes the modeling more accurate.Then a predictive controller is designed based on the model,and constraints are added to the objective function,which can not only solve the real-time changes of the control system by online optimization,but also effectively obtain a higher tracking accuracy of the inverter output voltage and lower total harmonic distortion rate(Total Harmonics Distortion,THD);and suppress the circulating current between the inverters,to obtain a good dynamic response.Finally,the simulation is carried out onMATLAB/Simulink to verify the correctness of the model and the rationality of the proposed strategy.This paper aims to provide guidance for the design and optimal control of multi-inverter parallel systems. 展开更多
关键词 Multiple inverters in parallel microgrid mixed logic dynamic model finite control set model predictive control circulation
下载PDF
A Sensor-less Surface Mounted PMSM for Electronic Speed Control in Multilevel Inverter
16
作者 S.Dinesh Kumar A.Jagadeeshwaran 《Intelligent Automation & Soft Computing》 SCIE 2023年第5期2201-2215,共15页
Recent advancements in power electronics technology evolves inverter fed electric motors.Speed signals and rotor position are essential for controlling an electric motor accurately.In this paper,the sensorless speed c... Recent advancements in power electronics technology evolves inverter fed electric motors.Speed signals and rotor position are essential for controlling an electric motor accurately.In this paper,the sensorless speed control of surface-mounted permanent magnet synchronous motor(SPMSM)has been attempted.SPMSM wants a digital inverter for its precise working.Hence,this study incor-poratesfifteen level inverter to the SPMSM.A sliding mode observer(SMO)based sensorless speed control scheme is projected to determine rotor spot and speed of the multilevel inverter(MLI)fed SPMSM.MLI has been operated using a multi carrier pulse width modulation(MCPWM)strategy for generation offif-teen level voltages.The simulation works are executed with MATLAB/SIMU-LINK software.The steadiness and the heftiness of the projected model have been investigated under no loaded and loaded situations of SPMSM.Furthermore,the projected method can be adapted for electric vehicles. 展开更多
关键词 Surface-mounted permanent magnet synchronous motor sensorless speed control multilevel inverter torque estimation multi carrier pulse width modulation
下载PDF
Simulation Study of the Control Strategy of a DC Inverter Heat Pump Using a DC Distribution Network
17
作者 Siwei Han Xianglong Li +3 位作者 Wei Zhao Linyu Wang Anqi Liang Shuang Zeng 《Energy Engineering》 EI 2023年第6期1421-1444,共24页
Photovoltaics,energy storage,direct current and flexibility(PEDF)are important pillars of achievement on the path to manufacturing nearly zero energy buildings(NZEBs).HVAC systems,which are an important part of public... Photovoltaics,energy storage,direct current and flexibility(PEDF)are important pillars of achievement on the path to manufacturing nearly zero energy buildings(NZEBs).HVAC systems,which are an important part of public buildings,play a key role in adapting to PDEF systems.This research studied the basic principles and operational control strategies of a DC inverter heat pump using a DC distribution network with the aim of contributing to the development and application of small DC distribution systems.Along with the characteristics of a DC distribution network and different operating conditions,a DC inverter heat pump has the ability to adapt to changes in the DC bus voltage and adds flexibility to the system.Theoretical models of the DC inverter heat pump integrated with an ice storage unit were developed.The control strategies of the DC inverter heat pump system considered the influence of both room temperature and varied bus voltage.A simulation study was conducted using MATLAB&Simulink software with simulation results validated by experimental data.The results showed that:(1)The bus fluctuation under the rated working voltage had little effect on the operation of the unit;(2)When the bus voltage was fluctuating from 80%-90%or 105%-107%,the heat pump could still operate normally by reducing the frequency;(3)When the bus voltage was less than 80%or more than 107%,the unit needed to be shut down for the sake of equipment safety,so that the energy storage device could adjust to the sharp decrease or rise of voltage. 展开更多
关键词 Photovoltaics energy storage direct current and flexibility DC inverter heat pump MATLAB&Simulink control strategy
下载PDF
Comparative analyses of mitogenomes in the social bees with insights into evolution of long inverted repeats in the Meliponini
18
作者 Yu-Ran Li Zheng-Wei Wang +1 位作者 Richard T.Corlett Wen-Bin Yu 《Zoological Research》 SCIE CSCD 2024年第1期160-175,共16页
The insect mitogenome is typically a compact circular molecule with highly conserved gene contents.Nonetheless,mitogenome structural variations have been reported in specific taxa,and gene rearrangements,usually the t... The insect mitogenome is typically a compact circular molecule with highly conserved gene contents.Nonetheless,mitogenome structural variations have been reported in specific taxa,and gene rearrangements,usually the tRNAs,occur in different lineages.Because synapomorphies of mitogenome organizations can provide information for phylogenetic inferences,comparative analyses of mitogenomes have been given increasing attention.However,most studies use a very few species to represent the whole genus,tribe,family,or even order,overlooking potential variations at lower taxonomic levels,which might lead to some incorrect inferences.To provide new insights into mitogenome organizations and their implications for phylogenetic inference,this study conducted comparative analyses for mitogenomes of three social bee tribes(Meliponini,Bombini,and Apini)based on the phylogenetic framework with denser taxonomic sampling at the species and population levels.Comparative analyses revealed that mitogenomes of Apini and Bombini are the typical type,while those of Meliponini show diverse variations in mitogenome sizes and organizations.Large inverted repeats(IRs)cause significant gene rearrangements of protein coding genes(PCGs)and rRNAs in Indo-Malay/Australian stingless bee species.Molecular evolution analyses showed that the lineage with IRs have lower dN/dS ratios for PCGs than lineages without IRs,indicating potential effects of IRs on the evolution of mitochondrial genes.The finding of IRs and different patterns of gene rearrangements suggested that Meliponini is a hotspot in mitogenome evolution.Unlike conserved PCGs and rRNAs whose rearrangements were found only in the mentioned lineages within Meliponini,tRNA rearrangements are common across all three tribes of social bees,and are significant even at the species level,indicating that comprehensive sampling is needed to fully understand the patterns of tRNA rearrangements,and their implications for phylogenetic inference. 展开更多
关键词 Social bees PHYLOGENY Mitogenome structure Gene rearrangement inverted repeats
下载PDF
Analysis of Progressively Type-Ⅱ Inverted Generalized Gamma Censored Data and Its Engineering Application
19
作者 Refah Alotaibi Sanku Dey Ahmed Elshahhat 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第10期459-489,共31页
A novel inverted generalized gamma(IGG)distribution,proposed for data modelling with an upside-down bathtub hazard rate,is considered.In many real-world practical situations,when a researcher wants to conduct a compar... A novel inverted generalized gamma(IGG)distribution,proposed for data modelling with an upside-down bathtub hazard rate,is considered.In many real-world practical situations,when a researcher wants to conduct a comparative study of the life testing of items based on cost and duration of testing,censoring strategies are frequently used.From this point of view,in the presence of censored data compiled from the most well-known progressively Type-Ⅱ censoring technique,this study examines different parameters of the IGG distribution.From a classical point of view,the likelihood and product of spacing estimation methods are considered.Observed Fisher information and the deltamethod are used to obtain the approximate confidence intervals for any unknown parametric function of the suggestedmodel.In the Bayesian paradigm,the same traditional inferential approaches are used to estimate all unknown subjects.Markov-Chain with Monte-Carlo steps are considered to approximate all Bayes’findings.Extensive numerical comparisons are presented to examine the performance of the proposed methodologies using various criteria of accuracy.Further,using several optimality criteria,the optimumprogressive censoring design is suggested.To highlight how the proposed estimators can be used in practice and to verify the flexibility of the proposed model,we analyze the failure times of twenty mechanical components of a diesel engine. 展开更多
关键词 inverted generalized gamma CENSORING spacing function LIKELIHOOD Bayesian optimal plan
下载PDF
Control of GaN inverted pyramids growth on c-plane patterned sapphire substrates
20
作者 Luming Yu Xun Wang +8 位作者 Zhibiao Hao Yi Luo Changzheng Sun Bing Xiong Yanjun Han Jian Wang Hongtao Li Lin Gan Lai Wang 《Journal of Semiconductors》 EI CAS CSCD 2024年第6期92-96,共5页
Growth of gallium nitride(GaN)inverted pyramids on c-plane sapphire substrates is benefit for fabricating novel devices as it forms the semipolar facets.In this work,GaN inverted pyramids are directly grown on c-plane... Growth of gallium nitride(GaN)inverted pyramids on c-plane sapphire substrates is benefit for fabricating novel devices as it forms the semipolar facets.In this work,GaN inverted pyramids are directly grown on c-plane patterned sapphire substrates(PSS)by metal organic vapor phase epitaxy(MOVPE).The influences of growth conditions on the surface morphol-ogy are experimentally studied and explained by Wulff constructions.The competition of growth rate among{0001},{1011},and{1122}facets results in the various surface morphologies of GaN.A higher growth temperature of 985 ℃ and a lowerⅤ/Ⅲratio of 25 can expand the area of{}facets in GaN inverted pyramids.On the other hand,GaN inverted pyramids with almost pure{}facets are obtained by using a lower growth temperature of 930℃,a higherⅤ/Ⅲratio of 100,and PSS with pattern arrangement perpendicular to the substrate primary flat. 展开更多
关键词 inverted pyramids GAN MOVPE crystal growth competition model
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部