Due to the components at twice the fundamental frequency of output voltage in the instantaneous output power of a two-stage single-phase inverter(TSI),the second harmonic current(SHC)is generated in the frontend dc-dc...Due to the components at twice the fundamental frequency of output voltage in the instantaneous output power of a two-stage single-phase inverter(TSI),the second harmonic current(SHC)is generated in the frontend dc-dc converter(FDC).To reduce the SHC,optimizing the control strategy of the FDC is an effective and costless approach.Fromthe view of visual impedance,this paper conducts an intensive study on the SHC reduction strategies.Origin of the SHC is illustrated first.Then,the equivalent circuit models of the FDC under different control strategies are proposed to analyse the SHC propagation characteristic.The derived model can offer a better insight into how the inductor SHC is affected by the control parameters.According to the derived models,a synthesis of different control strategies is presented and the relevant parameters are listed for control design to achieve better suppression effect.The benefits and limitations of these control strategies are also discussed.Based on the proposed equivalent circuit models,several optimization methods are proposed to enhance the effect.A 1500 VA TSI prototype is built and simulated on MATLAB/Simulink,verifying the effectiveness of the proposed optimization methods.This paper is aimed to provide a guideline for the control design and control optimization of the TSIs.展开更多
为了满足光伏微型逆变器高功率密度、高性能、低总谐波畸变率(total harmonic distortion,THD)的要求,文中基于临界电流模式提出一种多包络线谐振软开关逆变器控制策略,通过进行开关管的分时控制达到平衡电感电流上升下降时间的目的,从...为了满足光伏微型逆变器高功率密度、高性能、低总谐波畸变率(total harmonic distortion,THD)的要求,文中基于临界电流模式提出一种多包络线谐振软开关逆变器控制策略,通过进行开关管的分时控制达到平衡电感电流上升下降时间的目的,从而缓解过零点畸变。随后,详细介绍多包络线谐振软开关逆变器控制策略的工作模态,并从软开关、开关频率、开关管损耗与逆变效率、过零点畸变程度等方面与传统临界电流模式进行对比分析。为验证控制策略的有效性,文中基于PSIM搭建了500 W谐振软开关单相全桥逆变器进行开环仿真验证。仿真结果表明,与传统的单极性临界电流模式相比,多包络线临界电流模式可以有效优化过零点问题,能够滤除谐波、降低THD,并且实现零电流开关(zero current switch,ZCS)和全部开关管的零电压开关(zero voltage switch,ZVS)。展开更多
基金This work was supported in part by the Natural Science Foundation of Jiangsu Province under Grant BK20200969(L.Z.,http://std.jiangsu.gov.cn/).
文摘Due to the components at twice the fundamental frequency of output voltage in the instantaneous output power of a two-stage single-phase inverter(TSI),the second harmonic current(SHC)is generated in the frontend dc-dc converter(FDC).To reduce the SHC,optimizing the control strategy of the FDC is an effective and costless approach.Fromthe view of visual impedance,this paper conducts an intensive study on the SHC reduction strategies.Origin of the SHC is illustrated first.Then,the equivalent circuit models of the FDC under different control strategies are proposed to analyse the SHC propagation characteristic.The derived model can offer a better insight into how the inductor SHC is affected by the control parameters.According to the derived models,a synthesis of different control strategies is presented and the relevant parameters are listed for control design to achieve better suppression effect.The benefits and limitations of these control strategies are also discussed.Based on the proposed equivalent circuit models,several optimization methods are proposed to enhance the effect.A 1500 VA TSI prototype is built and simulated on MATLAB/Simulink,verifying the effectiveness of the proposed optimization methods.This paper is aimed to provide a guideline for the control design and control optimization of the TSIs.
文摘为了满足光伏微型逆变器高功率密度、高性能、低总谐波畸变率(total harmonic distortion,THD)的要求,文中基于临界电流模式提出一种多包络线谐振软开关逆变器控制策略,通过进行开关管的分时控制达到平衡电感电流上升下降时间的目的,从而缓解过零点畸变。随后,详细介绍多包络线谐振软开关逆变器控制策略的工作模态,并从软开关、开关频率、开关管损耗与逆变效率、过零点畸变程度等方面与传统临界电流模式进行对比分析。为验证控制策略的有效性,文中基于PSIM搭建了500 W谐振软开关单相全桥逆变器进行开环仿真验证。仿真结果表明,与传统的单极性临界电流模式相比,多包络线临界电流模式可以有效优化过零点问题,能够滤除谐波、降低THD,并且实现零电流开关(zero current switch,ZCS)和全部开关管的零电压开关(zero voltage switch,ZVS)。