Thermal Equilibration in the Cavity Volume of a Farmer Ion Chamber for Routine Dosimetry
1
作者 Yuichi Kato Hiraku Fuse +2 位作者 Kazuya Shinoda Katsumi Miyamoto Tatsuya Fujisaki 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2015年第4期268-272,共5页
A Farmer ion chamber with an air cavity volume is the most widely used dosimeter for accurate dose determinations in radiotherapy. The quantity of ionization in the cavity volume occurred a given radiation dose has to... A Farmer ion chamber with an air cavity volume is the most widely used dosimeter for accurate dose determinations in radiotherapy. The quantity of ionization in the cavity volume occurred a given radiation dose has to be corrected to the cavity air temperature according to a dosimetry protocol because the mass of air in the cavity volume is subject to atmospheric variations. In the present study, we aim to measure the thermal equilibration time in the cavity volume of a Farmer ion chamber for the routine dosimetry. The Farmer ion chamber’s electrode was replaced by a thin thermocouple and coated by the PMMA for a waterproofing so that the measurement of the temperature in the cavity performed in water. As a result of the measurement, A Farmer ion chamber in thermal equilibrium with waterproofing equilibrates rapidly, followed by an exponential fall-off. In water, equilibration to less than 10% of the initial temperature difference required only a few minutes. Thermal equilibrium time is hardly affected by the room temperature change. 展开更多
关键词 FARMER ion chamber THERMAL Equilibrium Time Temperature Characteristic ROUTINE DOSIMETRY
下载PDF
An online monitor ionization chamber used in particle therapy
2
作者 TANG Bin HU Zhengguo +13 位作者 MAO Ruishi XU Zhiguo WANG Jiansong YUE Ke TU Xiaolin WU Dapeng CHEN Jinda ZHANG Jie WANG Meng SUN Zhiyu ZHANG Xueheng LI Qiang XU Hushan XIOA Guoqing 《Nuclear Science and Techniques》 SCIE CAS CSCD 2009年第3期177-180,共4页
The clinical trials of tumor therapy using heavy ions beam 12C are now in progress at Institute of Modern Physics in Lanzhou. In order to achieve the precise radiotherapy with the high energy 12C beam in active pencil... The clinical trials of tumor therapy using heavy ions beam 12C are now in progress at Institute of Modern Physics in Lanzhou. In order to achieve the precise radiotherapy with the high energy 12C beam in active pencil beam scanning mode, we have developed an ionization chamber(IC) as an online monitor for beam intensity and also a dosimeter after calibration. Through the choosing of working gas and voltage, optimizing of the electrics and the read-out system, calibrating the linearity, the detector system provide us one of the simple and highly reliable way to monitoring the beam during the active pencil beam scanning treatments. The measurement results of this detector system show that it could work well under the condition of high energy 12C beam in active pencil beam scanning mode. 展开更多
关键词 肿瘤 治疗 临床 离子化 粒子
下载PDF
Comparison of different plasma chambers in microwave ion source for the intense neutron tube 被引量:1
3
作者 JING Shi-Wei, LIU Lin-Mao (Physics Department, Northeast Normal University, Changchun 130024) 《Nuclear Science and Techniques》 SCIE CAS CSCD 2003年第1期83-85,共3页
The microwave absorption efficiency, which is relevant to magnet field and its distribution, is a major parameter of the microwave ion source (MWIS) for the intense neutron tube. Based on previous work, the relations ... The microwave absorption efficiency, which is relevant to magnet field and its distribution, is a major parameter of the microwave ion source (MWIS) for the intense neutron tube. Based on previous work, the relations between microwave absorption efficiency and plasma chamber structure and thickness of the microwave introduction window are studied. The microwave absorption efficiency reaches to 100% when plasma chamber is 100mm long and the window thickness is 30mm. The microwave absorption efficiency as a function of pressure is also presented. 展开更多
关键词 等离子体 微波离子谱 微波吸收功率 MWIS 高密度中子管
下载PDF
一种具有射程鉴别能力的气体探测器研制
4
作者 修诚利 张文慧 +6 位作者 赵庆章 何明 包轶文 李康宁 李建良 郭巍 董鹏伟 《同位素》 CAS 2024年第4期341-346,共6页
在紧凑型加速器质谱系统(AMS)探测低能量离子时,具有相同磁刚度和电刚度的干扰离子会与被测核素一同进入探测器,对探测造成干扰。为解决这个问题,研制一种用于低能量小型AMS的可实现射程检测能力的气体探测器。通过被测核素与干扰离子... 在紧凑型加速器质谱系统(AMS)探测低能量离子时,具有相同磁刚度和电刚度的干扰离子会与被测核素一同进入探测器,对探测造成干扰。为解决这个问题,研制一种用于低能量小型AMS的可实现射程检测能力的气体探测器。通过被测核素与干扰离子射程不同,将干扰离子全部吸收在吸收室内,而被测核素可穿过吸收室并进入一个具有正比放大功能的放大室,从而实现被测核素的测定。为了验证气体探测器的性能,使用能量为5.8 MeV的α粒子进行一系列的调试实验。模拟和实验结果表明,吸收室可以有效地吸收不同能量的干扰离子,放大室一路信号的能量分辨率约30%。同时放大室的约化场强在5 V·mm^(−1)·hPa^(−1)时能够将信号放大约7倍,吸收室和放大室两路信号符合后的能量分辨率提高约20%,可为低能量小型AMS开展26Al、129I等核素的测量提供参考。 展开更多
关键词 加速器质谱 气体电离 干扰离子 吸收室 放大室
下载PDF
离子推力器溅射沉积物防剥离放电室的设计及激光选区熔化增材制造研究
5
作者 李建鹏 靳伍银 +3 位作者 赵以德 代鹏 张兴民 张文涛 《推进技术》 EI CAS CSCD 北大核心 2024年第5期259-266,共8页
为了抑制离子推力器寿命末期由溅射沉积导致的放电室膜层剥落物脱落,首先采用理论研究和试验的方法开展了剥落物抑制放电室的设计,基于零件结构和增材制造特点开展了零件工艺性分析并提出解决方案,实现了放电室增材制造,开展了离子推力... 为了抑制离子推力器寿命末期由溅射沉积导致的放电室膜层剥落物脱落,首先采用理论研究和试验的方法开展了剥落物抑制放电室的设计,基于零件结构和增材制造特点开展了零件工艺性分析并提出解决方案,实现了放电室增材制造,开展了离子推力器放电室溅射物防脱落性能测试。结果表明:放电室内表面设计纹理化结构排布形式为正六边形,凸起部分外接圆直径0.5 mm,间距0.25 mm,高度0.5 mm时可降低溅射沉积物脱落概率及碎屑尺寸,通过分层旋转扫描,选择激光功率425 W,扫描速度1200 mm/s工艺参数可实现大尺寸薄壁、具有复杂微小特征钛合金回转体制造,通过结构拓扑,镂空点阵结构、工艺参数和空间摆放位置优化,成型零件壁厚一致性偏差小于0.10 mm。放电室优化前后推力器性能稳定,各工作点关键参数相对误差小于4%。本文的研究为离子推力器放电室溅射沉积物脱落抑制方法和复杂结构的激光选区熔化增材制造成型提供了工程应用方案。 展开更多
关键词 离子推力器 放电室 溅射沉积物 选区激光熔化 抑制
下载PDF
Reformatted method for two-dimensional detector arrays measurement data in proton pencil beam scanning 被引量:2
6
作者 Meng-Ya Guo Xiu-Fang Li +6 位作者 Jie Wang Qi Liu Xiu-Zhen Deng Man-Zhou Zhang Li-Ren Shen Yue-Hu Pu Zhi-Ling Chen 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2021年第6期83-93,共11页
The spatial resolution of a commercial two-dimensional(2D)ionization chamber(IC)array is limited by the size of the individual detector and the center-to-center distance between sensors.For dose distributions with are... The spatial resolution of a commercial two-dimensional(2D)ionization chamber(IC)array is limited by the size of the individual detector and the center-to-center distance between sensors.For dose distributions with areas of steep dose gradients,inter-detector dose values are derived by the interpolation of nearby detector readings in the conventional mathematical interpolation of 2D IC array measurements.This may introduce significant errors,particularly in proton spot scanning radiotherapy.In this study,by combining logfile-based reconstructed dose values and detector measurements with the Laplacian pyramid image blending method,a novel method is proposed to obtain a reformatted dose distribution that provides an improved estimation of the delivered dose distribution with high spatial resolution.Meanwhile,the similarity between the measured original data and the downsampled logfilebased reconstructed dose is regarded as the confidence of the reformatted dose distribution.Furthermore,we quantify the performance benefits of this new approach by directly comparing the reformatted dose distributions with 2D IC array detector mathematically interpolated measurements and original low-resolution measurements.The result shows that this new method is better than the mathematical interpolation and achieves gamma pass rates similar to those of the original low-resolution measurements.The reformatted dose distributions generally yield a confidence exceeding 95%. 展开更多
关键词 2D ion chamber array detectors Laplacian pyramid image blending High-resolution reformatted methods Pencil beam scanning Proton therapy
下载PDF
Comparison of two methods for assessing leakage radiation dose around the head of the medical linear accelerators 被引量:1
7
作者 Ehab M. Attalla 《The Chinese-German Journal of Clinical Oncology》 CAS 2013年第9期435-438,共4页
Objective:The aim of this study was to measure the leakage by two methods with ion chamber and ready packs film,and to investigate the feasibility and the advantages of using two dosimetry methods for assessing leakag... Objective:The aim of this study was to measure the leakage by two methods with ion chamber and ready packs film,and to investigate the feasibility and the advantages of using two dosimetry methods for assessing leakage radiation around the head of the linear accelerators.Methods:Measurements were performed using a 30 cm3ion chamber;the gantry at 0°,the X-ray head at 0°,the field size at between the central axis and a plane surface at a FSD of 100 as a reference,a series of concentric circles having radii of 50,75,and 100 cm with their common centre at the reference point.The absorbed dose was measured at the reference point,and this would be used as the reference dose.With the diaphragm closed,the measurements were taken along the circumference of the three circles and at 45°intervals.Results:Leakage radiations while the treatment head was in the vertical position varied between 0.016%–0.04%.With the head lying horizontally,leakage radiation was the same order magnitude and varied between 0.02%–0.07%.In the second method,the verification was accomplished by closing the collimator jaws and covering the head of the treatment unit with the ready pack films.The films were marked to permit the determination of their positions on the machine after exposed and processed.With the diaphragm closed,and the ready packs films around the linear accelerator the beam turned on for 2500 cGy(2500 MU).The optical density of these films was measured and compared with this of the reference dose.Leakage radiation varied according to the film positions and the magnitude of leakage was between 0.005%–0.075%.Conclusion:The differences between the values of the leakage radiation levels observed at different measurement points do not only reflect differences in the effective shielding thickness of the head wall,but are also related to differences in the distances between the target and the measurement points.The experimental errors involved in dosimetric measurement also contribute to such differences. 展开更多
关键词 leakage radiation acceptance testing linear accelerator ion chamber ready packs film
下载PDF
基于热平衡的废旧锂离子电池回收系统二燃室简化用气量预测
8
作者 王振宇 郑俊超 《电源技术》 CAS 北大核心 2024年第8期1648-1652,共5页
基于锂离子电池回收过程中的质热平衡计算,依靠Matlab平台,针对物理破碎预处理过程(破碎-热处理-二燃-急冷),根据电池种类、单位时间投料量,以及二燃室相关结构参数计算过程中所需天然气与助燃空气量,为生产过程中工艺参数调节提供理论... 基于锂离子电池回收过程中的质热平衡计算,依靠Matlab平台,针对物理破碎预处理过程(破碎-热处理-二燃-急冷),根据电池种类、单位时间投料量,以及二燃室相关结构参数计算过程中所需天然气与助燃空气量,为生产过程中工艺参数调节提供理论支持;或根据所提供预计回收量推演二燃室尺寸,为回收过程精准化控制提供基础。 展开更多
关键词 锂离子电池回收 二燃室 焚烧 MATLAB polyfit函数
下载PDF
用于钙离子全光囚禁的离子囚禁装置研究
9
作者 陈正 王淼 +2 位作者 黄垚 管桦 高克林 《仪器仪表学报》 EI CAS CSCD 北大核心 2024年第2期102-111,共10页
随着离子光钟技术的飞速发展,由离子光钟中用来囚禁离子的射频场带来的微运动效应对其性能的影响也越来越不可忽略。为彻底消除这一效应,提出了全光囚禁离子光钟的实验方案。针对这一实验方案,设计并搭建了用于钙离子全光囚禁的离子囚... 随着离子光钟技术的飞速发展,由离子光钟中用来囚禁离子的射频场带来的微运动效应对其性能的影响也越来越不可忽略。为彻底消除这一效应,提出了全光囚禁离子光钟的实验方案。针对这一实验方案,设计并搭建了用于钙离子全光囚禁的离子囚禁装置。该装置是采用刀片型离子阱设计,能够实现剩余力仅有10^(-20) N量级的高精度的杂散电场补偿;具备6 mm的通关孔径,很好满足了全光囚禁实验中偶极囚禁激光的通过需求;基于改良的螺旋谐振器设计搭建的射频系统能够实现在9.33(1)MHz较低射频频率下的稳定耦合;结合高达10^(-9) Pa的真空制备和装配导电玻窗的真空腔体,可以实现长时间的离子囚禁。为全光囚禁钙离子提供了实验基础,对光学囚禁离子光钟的实现具有重大意义。 展开更多
关键词 离子光钟 全光囚禁 离子阱 射频 真空腔
下载PDF
连续变推力离子推力器双荷离子特性分析与诊断
10
作者 胡竟 耿海 +3 位作者 王东升 郭德洲 赵勇 杨福全 《北京航空航天大学学报》 EI CAS CSCD 北大核心 2023年第12期3303-3310,共8页
离子推力器束流离子中的双荷离子在制约栅极组件工作寿命的同时也影响到推力器实际推力的大小,其在总束流中的占比直接决定了推力器寿命、推力等关键性能指标的符合性。为准确、快速研判10 cm氙离子推力器在宽范围推力调节过程中的双荷... 离子推力器束流离子中的双荷离子在制约栅极组件工作寿命的同时也影响到推力器实际推力的大小,其在总束流中的占比直接决定了推力器寿命、推力等关键性能指标的符合性。为准确、快速研判10 cm氙离子推力器在宽范围推力调节过程中的双荷离子占比,利用放电室经验模型,分析了推力器变推力调节过程中双荷离子的变化特性及其影响因素,结合实际工作参数计算得到了不同推力工况点下双荷离子的理论占比。在此基础上,采用E×B探针诊断系统测试获得了相应推力工况点下双荷离子的实验占比,并将理论计算结果与实验测试结果进行了对比。研究结果表明:离子推力器放电室内双荷离子的占比是关于推力器工质利用率等性能参数及原初电子与麦氏电子间的密度比、电子温度等相关等离子体参数的函数;在变推力调节过程中,随着放电室内阳极功率的增加,束流中的双荷离子比例不断上升,且其引出束流中双荷离子比例分布呈现出强烈的非线性分布,整体表现为伴随增长的趋势。研究为离子推力器在轨控制策略的优化设计及性能评估提供了技术支持。 展开更多
关键词 离子推力器 连续变推力 放电室 双荷离子 诊断
下载PDF
10 cm考夫曼型离子推力器放电室关键参数优化
11
作者 胡竟 耿海 +3 位作者 杨福全 郭德洲 王东升 李建鹏 《北京航空航天大学学报》 EI CAS CSCD 北大核心 2023年第8期1974-1981,共8页
放电室构型设计是离子推力器结构设计的基础与核心,直接影响到放电室工作能效及整机工作寿命。针对新型航天器在轨飞行任务对大推力、长寿命连续变推力离子推力器的应用需求,探究了影响10 cm离子推力器整机效能的放电室关键参数因子,揭... 放电室构型设计是离子推力器结构设计的基础与核心,直接影响到放电室工作能效及整机工作寿命。针对新型航天器在轨飞行任务对大推力、长寿命连续变推力离子推力器的应用需求,探究了影响10 cm离子推力器整机效能的放电室关键参数因子,揭示了发散场放电室的磁场发散度、电子通道面积及阴极位置等敏感参数对放电室性能的影响作用关系。开展了10 cm离子推力器放电室参数构型的优化与验证。结果表明:在不改变整机结构的情况下,通过优化放电室关键参数,10 cm离子推力器最大输出推力由20 mN提升至25 mN,提升近25%,推力调节范围由1~20 mN扩展至1~25 mN,全范围内推力分辨率均优于50μN,且推力器在20 mN最佳工作点的阳极电压由43.5 V降至38.4 V,放电损耗由345 W/A降至308 W/A,预估整机寿命将由15000 h提升至17500 h。研究为推动10 cm离子推力器的在轨扩展应用提供了一定的技术支撑。 展开更多
关键词 无拖曳飞行 连续变推力 离子推力器 宽范围 放电室
下载PDF
放电室长度对电子回旋共振离子推力器性能的影响机理 被引量:2
12
作者 付瑜亮 杨涓 +1 位作者 夏旭 孙安邦 《物理学报》 SCIE EI CAS CSCD 北大核心 2023年第17期261-267,共7页
在电子回旋共振离子推力器的结构优化中,放电室长度调节的是栅极与主等离子体区的相对位置,以此影响栅极上游等离子体密度,进而改变推力器离子束流大小及聚焦状态,达到性能优化目的.然而,在一体化仿真研究中发现,施加栅极电压后,Child-L... 在电子回旋共振离子推力器的结构优化中,放电室长度调节的是栅极与主等离子体区的相对位置,以此影响栅极上游等离子体密度,进而改变推力器离子束流大小及聚焦状态,达到性能优化目的.然而,在一体化仿真研究中发现,施加栅极电压后,Child-Langmuir鞘层前存在高能电子分布,这与传统的放电室仿真存在明显差异.本文认为施加栅极电压后,Child-Langmuir鞘层会排斥电子,使流向栅极的电子返回磁镜区参与加热,最终在磁镜和Child-Langmuir鞘层之间形成了高能电子分布区域.这意味着放电室长度对推力器性能的影响不再局限于相对位置的调节,还能通过调控Child-Langmuir鞘层前的高能电子分布影响等离子体生成.因此,本文采用一体化仿真方法,系统研究了放电室长度对推力器放电和引出性能的影响机理,并讨论了Child-Langmuir鞘层前高能电子分布对电离体系的影响.本文研究将为电子回旋共振离子推力器的结构优化设计提供新思路. 展开更多
关键词 电子回旋共振 离子推力器 放电室长度
下载PDF
基于Geant4的碳离子治疗三维电离室阵列仿真设计 被引量:1
13
作者 廖峰 贺三军 +3 位作者 张双 罗万 刘丽艳 赵修良 《原子能科学技术》 EI CAS CSCD 北大核心 2023年第2期372-378,共7页
为快速准确地实现碳离子治疗计划的三维剂量验证,采用有机玻璃PMMA(聚甲基丙烯酸甲酯)为电离室室壁和水等效模体,设计了一种三维电离室阵列,并通过Geant4软件对三维电离室阵列的结构设计进行了深入研究与验证。首先通过模拟不同能量碳... 为快速准确地实现碳离子治疗计划的三维剂量验证,采用有机玻璃PMMA(聚甲基丙烯酸甲酯)为电离室室壁和水等效模体,设计了一种三维电离室阵列,并通过Geant4软件对三维电离室阵列的结构设计进行了深入研究与验证。首先通过模拟不同能量碳离子束在水和PMMA模体中沉积的剂量分布,计算了PMMA模体的水等效厚度系数;然后研究了三维电离室阵列中电离腔室间的距离及信号导线对其剂量测量准确度的影响;最后模拟并验证了碳离子束在三维电离室阵列中沉积的剂量分布。结果表明:PMMA模体的水等效厚度系数为1.151;相邻电离腔室间的信号串扰主要来源于前侧的电离腔室,且串扰程度与电离腔室间距呈反比,间距为1 mm时串扰程度占电离腔室内剂量的3%,间距为30 mm时串扰影响可完全消除;信号导线对后侧电离腔室内剂量的干扰影响约为1%。将碳离子束在三维电离室阵列中沉积的剂量分布与PMMA模体中的剂量分布进行对比,碳离子束的射程具有良好的一致性,偏差为0.5 mm。 展开更多
关键词 碳离子治疗 三维电离室阵列 GEANT4 三维剂量验证
下载PDF
用于锂电池测试的环境试验箱技术研究
14
作者 蒋剑炜 《环境技术》 2023年第7期138-141,共4页
本文对用于锂离子电池系统测试的环境试验箱进行了技术研究,通过分析锂离子电池系统的热失控原理,提出了用于锂离子电池系统测试的环境试验箱的安全防护和监测结构改进方法,使得环境试验箱在测试锂离子电池系统性能的同时具有良好的安... 本文对用于锂离子电池系统测试的环境试验箱进行了技术研究,通过分析锂离子电池系统的热失控原理,提出了用于锂离子电池系统测试的环境试验箱的安全防护和监测结构改进方法,使得环境试验箱在测试锂离子电池系统性能的同时具有良好的安全防护能力,为锂离子电池系统测试设备的研制提供参考。 展开更多
关键词 环境试验箱 锂离子电池系统 安全防护和监测
下载PDF
基于ICP-RIE工艺和共晶键合技术的微引擎
15
作者 周鑫 赖丽燕 李以贵 《微纳电子技术》 CAS 北大核心 2023年第9期1481-1487,共7页
针对便携式设备的电源存在能量密度不够、电池寿命短、回收利用困难以及难以实现小型化等问题,设计了一种氢气作为燃料的微型往复式引擎来替代小型电源,其整体设计尺寸为52 mm×43 mm×4 mm。利用绝缘体上硅(SOI)基板制作了微... 针对便携式设备的电源存在能量密度不够、电池寿命短、回收利用困难以及难以实现小型化等问题,设计了一种氢气作为燃料的微型往复式引擎来替代小型电源,其整体设计尺寸为52 mm×43 mm×4 mm。利用绝缘体上硅(SOI)基板制作了微型往复式引擎的零部件,包括上下盖板、燃烧室、活塞、弹簧和点火装置等;利用电感耦合等离子体-反应离子刻蚀(ICPRIE)得到垂直度接近90°的硅燃烧室、活塞等部件;利用Au-Si共晶键合等关键工艺,保证了上、下盖板与燃烧室等部件之间的气密性。为了验证微引擎的的可行性,搭建了一套测量燃烧压及活塞往复运动的实验装置,测得最大燃烧压约为50 kPa,活塞最大行程长度为1.6 mm,因此其具有广阔的应用前景。 展开更多
关键词 微型往复式引擎 燃烧室 电感耦合等离子体-反应离子刻蚀(ICP-RIE) 共晶键合 燃烧压 活塞
下载PDF
20cm氙离子推力器放电室性能优化 被引量:19
16
作者 陈娟娟 张天平 +1 位作者 贾艳辉 李小平 《强激光与粒子束》 EI CAS CSCD 北大核心 2012年第10期2469-2473,共5页
束流离子生产成本和推进剂利用率是表征离子推力器放电室性能的重要参数。在考虑不改变放电室几何结构、磁场分布并保持离子推力器比冲和效率的前提下,利用一维经验分析模型对兰州空间技术物理研究所研制的LIPS-200离子推力器放电室性... 束流离子生产成本和推进剂利用率是表征离子推力器放电室性能的重要参数。在考虑不改变放电室几何结构、磁场分布并保持离子推力器比冲和效率的前提下,利用一维经验分析模型对兰州空间技术物理研究所研制的LIPS-200离子推力器放电室性能进行了优化分析,以实现推力器的推力从40mN提高到60mN的目标要求。分析结果表明,提高放电室推进剂流率至2.06mg/s,放电室内放电电流维持在6.9A,放电室内平均氙离子密度达到2.167×1017 m-3时,可以保证引出1.2A的束流,推力器达到60mN的推力。与之对应的推进剂利用率为92%,束流离子生产成本约为188.515 W/A,相比推力40mN时,推进剂利用率为88%、束流离子生产成本为188.29W/A的情况,放电室性能有所提高。另外,放电室性能优化过程中其鞘层电位始终保持在3.80~6.65eV范围内。 展开更多
关键词 离子推力器 放电室 束流离子生产成本 推进剂利用率
下载PDF
二维电离室矩阵在加速器日常质量保证中的应用与研究 被引量:12
17
作者 于得全 高宏 +2 位作者 邵秋菊 梁军 张昕 《中国医学物理学杂志》 CSCD 2010年第4期1973-1975,2062,共4页
目的:探讨应用二维电离室矩阵在加速器日常质量保证中的可行性。方法:使用二维电离室矩阵分别测量加速器的照射野与灯光野的重合性、等中心、照射野的对称性及平坦度、楔形板角度等。结果:加速器的照射野与灯光野的重合性、等中心、照... 目的:探讨应用二维电离室矩阵在加速器日常质量保证中的可行性。方法:使用二维电离室矩阵分别测量加速器的照射野与灯光野的重合性、等中心、照射野的对称性及平坦度、楔形板角度等。结果:加速器的照射野与灯光野的重合性、等中心、照射野的对称性及平坦度、楔形板角度等测量结果均在允许范围内,符合临床要求。结论:二维电离室矩阵可用于加速器日常质量保证的测量,是放疗设备日常质量控制的理想工具。 展开更多
关键词 二维电离室矩阵 加速器 质量保证
下载PDF
10cm离子推力器放电室性能优化研究 被引量:14
18
作者 杨福全 王蒙 +3 位作者 郑茂繁 杨威 江豪成 张天平 《推进技术》 EI CAS CSCD 北大核心 2017年第1期235-240,共6页
要实现离子推力器较高的效率和比冲等综合性能指标,优化的放电室性能是其首要的前提条件。为了获得10cm离子推力器优化的放电室性能,在放电室初始设计方案基础上,通过对工作参数和结构参数的不同组合试验,开展了性能优化研究,采用的主... 要实现离子推力器较高的效率和比冲等综合性能指标,优化的放电室性能是其首要的前提条件。为了获得10cm离子推力器优化的放电室性能,在放电室初始设计方案基础上,通过对工作参数和结构参数的不同组合试验,开展了性能优化研究,采用的主要手段是关键特征尺寸调节、流率调节和磁场参数的调节。试验获得了不同参数组合的性能变化趋势,得出了优化的放电室结构参数和工作参数。优化后的离子推力器综合性能试验结果表明,在推力15.6m N、比冲3100s的设计工况下放电损耗约为227W/A,放电室工质利用率为91%。 展开更多
关键词 离子推力器 放电室 性能 优化
下载PDF
调强适形放射治疗的剂量学验证 被引量:5
19
作者 沈文同 涂彧 +1 位作者 王建华 方明明 《辐射防护》 CAS CSCD 北大核心 2007年第5期257-263,共7页
调强适形放射治疗(IMRT)是近年来发展的一项崭新的放疗技术,有关它的质量保证和质量控制是一个急需解决和必须重视的问题,而其中剂量学验证是极其重要的一方面。本研究的目的就是要探讨调强适形放射治疗过程中的剂量学验证方法,保证IMR... 调强适形放射治疗(IMRT)是近年来发展的一项崭新的放疗技术,有关它的质量保证和质量控制是一个急需解决和必须重视的问题,而其中剂量学验证是极其重要的一方面。本研究的目的就是要探讨调强适形放射治疗过程中的剂量学验证方法,保证IMRT治疗计划临床实施的正确性。研究过程为选取10例需要实施IMRT的病人,利用CMS公司的Xio三维治疗计划系统设计出IMRT计划,用Cirs调强胸段体模作为验证体模,将病人的IMRT计划移植至体模生成QA计划,计算出选定验证点的绝对剂量和选定验证平面的相对剂量分布。在加速器上按QA计划条件摆位并实施照射,得到用0.6cc电离室实测的验证点绝对剂量和用GafChromicEBT免洗胶片拍摄的平面剂量片,用RIT113胶片剂量分析软件分析实测的和计划的平面相对剂量分布。10例病人的剂量学验证结果表明,绝对剂量误差在5%以内,相对剂量分布在高剂量区很接近,低剂量区有一定差别。 展开更多
关键词 调强适形放射治疗 体模 电离室 胶片 剂量学验证
下载PDF
真空紫外-软X射线波段(5~105nm)探测器校准装置的研制 被引量:3
20
作者 刘金元 薛凤仪 +4 位作者 李平 崔明启 赵屹东 周洪军 霍同林 《计量学报》 EI CSCD 北大核心 2008年第3期275-279,共5页
介绍了中国计量科学研究院在真空紫外-软X射线波段(5~105 nm)探测器标准研究的新进展。介绍了建立在中国科学技术大学国家同步辐射实验室的以稀有气体电离室为标准探测器的探测器校准装置,以及利用该电离室作为基准探测器对作为传递... 介绍了中国计量科学研究院在真空紫外-软X射线波段(5~105 nm)探测器标准研究的新进展。介绍了建立在中国科学技术大学国家同步辐射实验室的以稀有气体电离室为标准探测器的探测器校准装置,以及利用该电离室作为基准探测器对作为传递标准探测器的硅光电二极管的量子效率测量的结果,在5~35 nm范围内,相对标准不确定度为18%~20%。与NIST的结果相比,有较好的符合。 展开更多
关键词 计量学 真空紫外 软X射线 电离室 标准探测器
下载PDF