期刊文献+
共找到7,354篇文章
< 1 2 250 >
每页显示 20 50 100
Geogenic Pollution of Groundwater Quality in Gampaha District, Sri Lanka: A Case Study of Groundwater Acidification from Rathupaswala
1
作者 Ishara Pathirage Anushka Upamali Rajapaksha +1 位作者 S. P. Sucharitha Bandara G. W. A. Rohan Fernando 《International Journal of Geosciences》 CAS 2024年第8期590-604,共15页
Over recent decades, Gampaha district, Sri Lanka, has experienced significant urbanisation and industrial growth, increasing groundwater demand due to limited and polluted surface water resources. In 2013, a community... Over recent decades, Gampaha district, Sri Lanka, has experienced significant urbanisation and industrial growth, increasing groundwater demand due to limited and polluted surface water resources. In 2013, a community uprising in Rathupaswala, a village in Gampaha district, accused a latex glove manufacturing factory of causing groundwater acidity (pH < 4). This study evaluates the spatial and temporal changes in geochemical parameters across three transects in the southern part of Gampaha district to 1) assess the impact of geological formations on groundwater;2) compare temporal variations in groundwater;and 3) explain acidification via a geochemical model. Seventy-two sample locations were tested for pH, electrical conductivity (EC), and anion concentrations (sulphate, nitrate, chloride and fluoride). Depth to the water table and distance from the sea were measured to study variations across sandy, peaty, lateritic, and crystalline aquifers. Results showed pH readings around 7 for sandy and crystalline aquifers, below 7 for peaty aquifers, and below 5 for lateritic aquifers, with significant water table fluctuations near Rathupaswala area. Principal component analysis revealed three principal components (PCs) explaining 86.0% of the variance. PC1 (40.6%) correlated with pH, EC, and sulphate (saltwater intrusion), while PC2 (32.0%) correlated with nitrates and depth to the water table (anthropogenic nutrient pollution). A geochemical transport model indicated a cone of depression recharged by acidic groundwater from peat-soil aquifers, leading to acidic groundwater in Rathupaswala area. Previous attributions of acidic pH to the over-exploitation of groundwater by the latex factory have been reevaluated;the results suggest natural acidification from prolonged water-rock interactions with iron-rich lateritic aquifers. Groundwater pH is influenced by local climate, geology, topography, and drainage systems. It is recommended that similar water-rock interaction conditions may be present throughout the wet zone of Sri Lanka, warranting detailed studies to confirm this hypothesis. 展开更多
关键词 Groundwater Acidification Acid Sulphate Soils (AAS) ion chromatography Groundwater Quality
下载PDF
Volatile Compounds Fingerprints for White Duck down and White Goose down Determined by Gas Chromatography-Ion Mobility Spectrometry
2
作者 Fei Wang Qihui Zhang +6 位作者 Yiwen Lin Wenjian Chen Hui Wang Kuntai Li Jihua Li Yuliang Chen Leiyu Wang 《Agricultural Sciences》 CAS 2023年第3期432-445,共14页
This work first describes a simple approach for the untargeted profiling of volatile compounds for distinguishing between white duck down (WDD) and white goose down (WGD) based on resolution-optimized GC-IMS combined ... This work first describes a simple approach for the untargeted profiling of volatile compounds for distinguishing between white duck down (WDD) and white goose down (WGD) based on resolution-optimized GC-IMS combined with optimized chemometric techniques, namely PCA. The detection method for down samples was established by using GC-IMS. Meanwhile, the reason of unpleasant odors caused by WDD was explained on the basis of the characteristic volatile compounds identification. GC-IMS fingerprinting can be considered a revolutionary approach for a truly fully automatable, cost-efficient, and in particular highly sensitive method. A total of 22 compounds were successfully separated and identified through GC-IMS method, and the significant differences in volatile compounds were observed in three parts of WDD and WGD samples. The most characteristic volatile compounds of WGD belong to aldehydes, whereas carboxylic acids from WDD were detected generated by autoxidation reaction. Meanwhile, the main reason of unpleasant odor generation was possibly attributed to the high concentration of volatile carboxylic acids of WDD. Therefore, the constructed model presents a simple and efficient method of analysis and serves as a basis for down processing and quality control. 展开更多
关键词 Gas chromatography-ion Mobility Spectrometry (GC-IMS) Principal Components Analysis (PCA) DOWN Characteristic Volatiles Fingerprints Carboxylic Acids
下载PDF
Analysis of Sugar Components of Fermented Rice Wine by Ion Chromatography 被引量:2
3
作者 蔡柳 苏小军 熊兴耀 《Agricultural Science & Technology》 CAS 2013年第10期1500-1502,共3页
[Objective] The aim was to analyze sugar components in fermented rice wine by ion chromatography. [Method] The optimal condition for chromatography system of sugar analysis was selected by measuring sugars in fermente... [Objective] The aim was to analyze sugar components in fermented rice wine by ion chromatography. [Method] The optimal condition for chromatography system of sugar analysis was selected by measuring sugars in fermented rice wine with ion chromatography and pulsed amperometric detection. [Result] The optimal measurement conditions were as follows: Leacheate (Leachate), consisting of NaOH and CH3COONa, was eluted by gradient concentrations, with column temperature at 35 ℃ and flow rate at 0.4 ml/min. In the condition, sugars in rice wine were ana- lyzed and the results showed that the method is featured by low detection limit, good repetition and high recovery rate. [Conclusion] The research establishes and determines the approaches and optimum conditions for sugar analysis in rice wine by ion chromatography and pulsed amperometric detection, providing references for advancement of research on quality improvement of fermented rice wine. 展开更多
关键词 Rice wine ion chromatography FERMENTATion
下载PDF
Determination of Chlorine and Bromine in Plant Materials by Ion Chromatography 被引量:1
4
作者 胡兰 陈波 《Agricultural Science & Technology》 CAS 2016年第10期2403-2405,共3页
A method was developed for determination of chlorine and bromine in plant materials by ion chromatography using temperature programing-semi molten for sample preparation. Values of detection limits of the method found... A method was developed for determination of chlorine and bromine in plant materials by ion chromatography using temperature programing-semi molten for sample preparation. Values of detection limits of the method found were 1.0×10^-5 for CI and 1.3×10^-6 for Br. The measuring range of the method found were 0.3-20.0 mg/L for CI and 4,0-120,0 μg/L for Br. The results obtained agreed quite well with those reference values. 展开更多
关键词 ion chromatography Temperature programing-semi molten PLANT CHLORINE BROMINE
下载PDF
Application of ion chromatography to the determination of water-soluble inorganic and organic ions in atmospheric aerosols 被引量:5
5
作者 YUXue-chun HEKe-bin +4 位作者 MAYong-liang YANGFu-mo DUANFeng-kui ZHENGAi-hua ZHAOCheng-yi 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2004年第5期813-815,共3页
A simple, sensitive and convenient ion chromatography(IC) method was established for the simultaneous determination of twelve water-soluble inorganic anions(F -, Cl -, NO - 2, NO - 3, SO 2- 3, SO 2- ... A simple, sensitive and convenient ion chromatography(IC) method was established for the simultaneous determination of twelve water-soluble inorganic anions(F -, Cl -, NO - 2, NO - 3, SO 2- 3, SO 2- 4, PO 3- 4), and fifteen water-soluble organic ions(formate, acetate, MSA, oxalate, malonate, succinate, phthalates, etc.) in atmospheric aerosols. The linear concentrations ranged from 0.005 μg/m 3 to 500 μg/m 3(r = 0.999—0.9999). The relative standard deviation(RSD) were 0.43%—2.00% and the detection limits were from 2.7 ng/m 3 to 88 ng/m 3. The proposed method was successfully applied to the simultaneous determination of those inorganic ions and organic ions in PM 2.5 of Beijing. 展开更多
关键词 ion chromatography water-soluble ions AEROSOLS BEIJING
下载PDF
Implications from protein uptake kinetics onto dextran-grafted Sepharose FF coupled with ion exchange and affinity ligands 被引量:10
6
作者 Aiying Xue Linling Yu Yan Sun 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2017年第7期906-910,共5页
Our previous studies have reported the presence of "chain delivery" effects of protein adsorption onto ion exchangers with polymer-grafted ion-exchange groups, such as dextran-grafted and poly(ethylenimine)-... Our previous studies have reported the presence of "chain delivery" effects of protein adsorption onto ion exchangers with polymer-grafted ion-exchange groups, such as dextran-grafted and poly(ethylenimine)-modified Sepharose gels. However, it is unclear if the "chain delivery" occurs on affinity adsorption with specific interactions. This work is designed to address this issue. A dextran-grafted Sepharose gel was prepared, and then the matrix was modified using diethylaminoethyl, a typical ion-exchange group, or octapeptide(FYCHWQDE), an affinity ligand for human immunoglobulin G(h Ig G) to prepare ion-exchange or affinity adsorbents, respectively.Results of h Ig G adsorption showed that the uptake rate represented by the effective diffusivity of h Ig G onto the dextran-grafted ion exchangers was obviously enhanced by the dextran grafting, indicating the presence of"chain delivery" of the bound proteins on the charged groups on the dextran chains. By contrast, the effective diffusivity of h Ig G changed little as ligand density increased on the dextran-grafted FYCHWQDE adsorbents.Their adsorption capacities decreased and effective diffusivities were not accelerated by the dextran grafting.Thus, this work clarified that grafted dextran could not accelerate h Ig G uptake rate on the affinity resins, or in other words, chain delivery did not occur on the specific interaction-based affinity adsorption. 展开更多
关键词 Dextran-grafted adsorbent ion exchange chromatography Affinity chromatography lmmunoglobulin G KINETics
下载PDF
Liquid chromatography coupled with time-of-flight and ion trap mass spectrometry for qualitative analysis of herbal medicines 被引量:11
7
作者 Xiao-Fei Chen Hai-Tang Wu +2 位作者 Guang-Guo Tan Zhen-Yu Zhu Yi-Feng Chai 《Journal of Pharmaceutical Analysis》 SCIE CAS 2011年第4期235-245,共11页
With the expansion of herbal medicine (HM) market, the issue on how to apply up-to- date analytical tools on qualitative analysis of HMs to assure their quality, safety and efficacy has been arousing great attention... With the expansion of herbal medicine (HM) market, the issue on how to apply up-to- date analytical tools on qualitative analysis of HMs to assure their quality, safety and efficacy has been arousing great attention. Due to its inherent characteristics of accurate mass measurements and multiple stages analysis, the integrated strategy of liquid chromatography (LC) coupled with time-of-flight mass spectrometry (TOF-MS) and ion trap mass spectrometry (IT-MS) is well-suited to be performed as qualitative analysis tool in this field. The purpose of this review is to provide an overview on the potential of this integrated strategy, including the review of general features of LC-IT-MS and LC-TOF-MS, the advantages of their combination, the common procedures for structure elucidation, the potential of LC-hybrid-IT-TOF/MS and also the summary and discussion of the applications of the integrated strategy for HM qualitative analysis (2006-2011). The advantages and future developments of LC coupled with IT and TOF-MS are highlighted. 展开更多
关键词 High-performanceliquid chromatography(HPLC) Time-of-flight massspectrometry(TOF-MS) ion trap massspectrometry (IT-MS) Herbal medicine (HM)
下载PDF
Simultaneous determination of fluorine and iodine in urine by ion chromatography with electrochemical pretreatment 被引量:4
8
作者 Kang Kang Hu Wei Xiong Huang Yu Hua Su Rong Zong Hu 《Chinese Chemical Letters》 SCIE CAS CSCD 2009年第12期1483-1486,共4页
A new method for the simultaneous determination of fluorine and iodine in urine by ion chromatography (IC) with electrochemical pretreatment has been developed. The pretreatment was performed in a novel electrochemi... A new method for the simultaneous determination of fluorine and iodine in urine by ion chromatography (IC) with electrochemical pretreatment has been developed. The pretreatment was performed in a novel electrochemical oxidationneutralization device (EOND), in which iodide of the sample was oxidized to iodate and the alkaline digestion sample solution was neutralized. Under the optimized conditions, the limits of detection (LOD, S/N = 3) were 2.5 μg/L for fluoride and 20 μg/L for iodate, respectively. The recoveries were in the range of 93-102% for fluoride and 86-98% for iodate. 展开更多
关键词 FLUORINE IODINE URINE Electrochemical pretreatment ion chromatography
下载PDF
Science Letters:Simultaneous determination of fluoride, chloride, sulfate, phosphate, monofluorophosphate, glycerophosphate, sorbate, and saccharin in gargles by ion chromatography 被引量:7
9
作者 ZHANG Yan-zhen ZHOU Yan-chun +1 位作者 LIU Li ZHU Yan 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE CAS CSCD 2007年第7期507-511,共5页
Simple, reliable and sensitive analytical methods to determine anticariogenic agents, preservatives, and artificial sweeteners contained in commercial gargles are necessary for evaluating their effectiveness, safety, ... Simple, reliable and sensitive analytical methods to determine anticariogenic agents, preservatives, and artificial sweeteners contained in commercial gargles are necessary for evaluating their effectiveness, safety, and quality. An ion chroma-tography (IC) method has been described to analyze simultaneously eight anions including fluoride, chloride, sulfate, phosphate, monofluorophosphate, glycerophosphate (anticariogenic agents), sorbate (a preservative), and saccharin (an artificial sweetener) in gargles. In this IC system, we applied a mobile phased gradient elution with KOH, separation by IonPac AS18 columns, and suppressed conductivity detection. Optimized analytical conditions were further evaluated for accuracy. The relative standard deviations (RSDs) of the inter-day's retention time and peak area of all species were less than 0.938% and 8.731%, respectively, while RSDs of 5-day retention time and peak area were less than 1.265% and 8.934%, respectively. The correlation coefficients for targeted analytes ranged from 0.999 7 to 1.000 0. The spiked recoveries for the anions were 90%~102.5%. We concluded that the method can be applied for comprehensive evaluation of commercial gargles. 展开更多
关键词 ion chromatography ANionS Gargles MONOFLUOROPHOSPHATE SORBATE SACCHARIN
下载PDF
A novel protein refolding method integrating ion exchange chromatography with artificial molecular chaperone 被引量:3
10
作者 Qin Ming Zhang Chao Zhan Wang Jiang Feng Liu Li Li Wang 《Chinese Chemical Letters》 SCIE CAS CSCD 2008年第5期595-598,共4页
Artificial molecular chaperone (AMC) and ion exchange chromatography (IEC) were integrated, thus a new refolding method, artificial molecular chaperone-ion exchange chromatography (AMC-IEC) was developed. Compar... Artificial molecular chaperone (AMC) and ion exchange chromatography (IEC) were integrated, thus a new refolding method, artificial molecular chaperone-ion exchange chromatography (AMC-IEC) was developed. Compared with AMC and IEC, the activity recovery of lysozyme obtained by AMC-IEC was much higher in the investigated range of initial protein concentrations, and the results show that AMC-IEC is very efficient for protein refolding at high concentrations. When the initial concentration of lysozyme is 180 mg/mL, its activity recovery obtained by AMC-IEC is still as high as 76.6%, while the activity recoveries obtained by AMC and IEC are 45.6% and 42.4%, respectively. 展开更多
关键词 Artificial molecular chaperone ion exchange chromatography Protein refolding LYSOZYME Protein folding liquid chromatography
下载PDF
Determination of haloacetic acids in hospital effuent after chlorination by ion chromatography 被引量:2
11
作者 SUN Ying-xue GU Ping 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2007年第7期885-891,共7页
The ion chromatography combined solid phase extraction (SPE) method was developed for the analysis of low concentration haloacetic acids (HAAs), a class of disinfection by-products formed from chlorination of hosp... The ion chromatography combined solid phase extraction (SPE) method was developed for the analysis of low concentration haloacetic acids (HAAs), a class of disinfection by-products formed from chlorination of hospital wastewater. The monitored HAAs included monochloroacetic acid, monobromoacetic acid, dichloroacetic acid, dibromoacetic acid and trichloroacetic acid. The method employed a sodium hydroxide eluent at a flow rate of 0.8 ml/min, electrolytically generated gradients, and suppressed conductivity detection. To analyze the HAAs in real hospital wastewater samples, C18 pretreatment cartridge was utilized to reduce samples' turbidity. Preconcentration with SPE and matrix elimination with treatment cartridges were investigated and found to be able to obtain acceptable detection limits. Linearity, repeatability and detection limits of the above method were evaluated. The detection limits of monobromoacetic acid and dibromoacetic acid were 2.61 μg/L and 1.30 μg/L, respectively, and the other three acids are ranging from 0.48 to 0.82μg/L under 25-fold preconcentration. When the above optimization procedure was applied to three hospital wastewater samples with different treatment processes in Tianjin, it was found that the dichloroacetic acid was the major compound, and the growth ratios of the HAAs after disinfection by sodium hypochlorite were 91.28%, 63.61% and 79.50%, respectively. 展开更多
关键词 hospital wastewater analysis ion chromatography (IC) sample pretreatment solid phase extraction (SPE) CHLORINATion haloacetic acids (HAAs)
下载PDF
Offline two-dimensional liquid chromatography coupled with ion mobility-quadrupole time-of-flight mass spectrometry enabling fourdimensional separation and characterization of the multicomponents from white ginseng and red ginseng 被引量:9
12
作者 Tiantian Zuo Chunxia Zhang +7 位作者 Weiwei Li Hongda Wang Ying Hu Wenzhi Yang Li Jia Xiaoyan Wang Xiumei Gao Dean Guo 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2020年第6期597-609,共13页
Inherent complexity of plant metabolites necessitates the use of multi-dimensional information to accomplish comprehensive profiling and confirmative identification.A dimension-enhanced strategy,by offline two-dimensi... Inherent complexity of plant metabolites necessitates the use of multi-dimensional information to accomplish comprehensive profiling and confirmative identification.A dimension-enhanced strategy,by offline two-dimensional liquid chromatography/ion mobility-quadrupole time-of-flight mass spectrometry(2 D-LC/IM-QTOF-MS)enabling four-dimensional separations(2 D-LC,IM,and MS),is proposed.In combination with in-house database-driven automated peak annotation,this strategy was utilized to characterize ginsenosides simultaneously from white ginseng(WG)and red ginseng(RG).An offline 2 DLC system configuring an Xbridge Amide column and an HSS T3 column showed orthogonality 0.76 in the resolution of ginsenosides.Ginsenoside analysis was performed by data-independent high-definition MSE(HDMSE)in the negative ESI mode on a Vion?IMS-QTOF hybrid high-resolution mass spectrometer,which could better resolve ginsenosides than MSEand directly give the CCS information.An in-house ginsenoside database recording 504 known ginsenosides and 58 reference compounds,was established to assist the identification of ginsenosides.Streamlined workflows,by applying UNIFI?to automatedly annotate the HDMSEdata,were proposed.We could separate and characterize 323 ginsenosides(including 286 from WG and 306 from RG),and 125 thereof may have not been isolated from the Panax genus.The established 2 D-LC/IM-QTOF-HDMSEapproach could also act as a magnifier to probe differentiated components between WG and RG.Compared with conventional approaches,this dimensionenhanced strategy could better resolve coeluting herbal components and more efficiently,more reliably identify the multicomponents,which,we believe,offers more possibilities for the systematic exposure and confirmative identification of plant metabolites. 展开更多
关键词 Dimension-enhanced strategy Multicomponent characterization GINSENOSIDE Offline two-dimensional liquid chromatography ion mobility-quadrupole time-of-flight mass spectrometry In-house database
下载PDF
Determination of fluorinated quinolone antibacterials by ion chromatography with fluorescence detection 被引量:4
13
作者 ZHANG Yan-zhen ZHANG Zheng-yi +2 位作者 ZHOU Yan-chun LIU Li ZHU Yan 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE CAS CSCD 2007年第5期302-306,共5页
For preparing fluorinated quinolone antibiotic medicine locally used in stomatology, simultaneous determination of norfloxacin, ciprofloxacin, and enoxacin was carried out by multiphase ion chromatography with fluores... For preparing fluorinated quinolone antibiotic medicine locally used in stomatology, simultaneous determination of norfloxacin, ciprofloxacin, and enoxacin was carried out by multiphase ion chromatography with fluorescence detection. Quinolone antibiotics were separated by Dionex OmniPac PAX-500 column with an eluent of 15 mmol/L H2SO4 and 35% methanol (v/v) at a flow-rate of 1.0 ml/min and detected with fluorescence with excitation and emission wave lengths of 347 ran and 420 ran respectively. The detection limits (S/N=3) of norfloxacin, ciprofloxacin and enoxacin were 50, 105 and 80 ng/ml respectively. The relative standard deviations of retention time, peak area and peak height were less than 1.1% and good linear relationship resulted. The developed method was applied to pharmaceutical formulations and biological fluids. 展开更多
关键词 Fluorinated quinolone ion chromatography Fluorescence detection
下载PDF
Determination of sulfur anions by ion chromatography-postcolumn derivation and UV detection 被引量:2
14
作者 Mei Lan Chen Ming Li Ye +2 位作者 Xue Ling Zeng Yun Chang Fan Zhu Yan 《Chinese Chemical Letters》 SCIE CAS CSCD 2009年第10期1241-1244,共4页
A novel method for determination of formaldehyde sulfoxylate, sulfite, thiocyanate, and thiosulfate in foodstuffs by ion chromatography separation with postcolumn derivation and UV detection has been developed. All sp... A novel method for determination of formaldehyde sulfoxylate, sulfite, thiocyanate, and thiosulfate in foodstuffs by ion chromatography separation with postcolumn derivation and UV detection has been developed. All species are separated at Dionex IonPac AG22A and AS22A with mobile phase of a mixture of 4.5 mmol/L sodium carbonate and 0.8 mmol/L sodium bicarbonate at a flow-rate of 1.0 mL/min. The postcolunm derivation solution was 0.24% iodine in 0.2% phosphate acid and the detection wavelength was set at 288 nm. The detection limits (LOD, signal-to-noise ratio of 3) of formaldehyde sulfoxylate, sulfite, thiocyanate, and thiosulfate were 0.004, 0.006, 0.006, and 0.007 mg/L, respectively. Within-day relative standard deviations (RSD, n = 10) of formaldehyde sulfoxylate, sulflte, thiocyanate, and thiosulfate were 3.24%, 3.76%, 2.68%, and 2.07%, respectively. The recoveries of the four anions were in the range of 67.2-116.5%. 展开更多
关键词 Postcolumn derivation ion chromatography Sulfur-containing inorganic compounds
下载PDF
Measurement of trace nitrate concentrations in seawater by ion chromatography with valve switching 被引量:2
15
作者 杜娟 法芸 +3 位作者 郑岳 李学兵 杜芳林 杨海燕 《Chinese Journal of Oceanology and Limnology》 SCIE CAS CSCD 2014年第3期732-736,共5页
An ion chromatographic method with a valve switching facility was developed to determine trace nitrate concentrations in seawater using two pumps, two different suppressors, and two columns. A carbohydrate membrane de... An ion chromatographic method with a valve switching facility was developed to determine trace nitrate concentrations in seawater using two pumps, two different suppressors, and two columns. A carbohydrate membrane desalter was used to reduce the high concentrations of sodium salts in samples. In this method, trace nitrate was eluted from the concentrator column to the analytical columns, while the matrix fl owed to waste. Neither chemical pre-treatment nor sample dilution was required. In the optimized separation conditions, the method showed good linearity( R >0.99) in the 0.05 and 50 mg/L concentration range, and satisfactory repeatability(RSD<5%, n =6). The limit of detection for nitrate was 0.02 mg/L. Results showed that the valve switching system was suitable and practical for the determination of trace nitrate in seawater. 展开更多
关键词 ion chromatography valve switching seawater nitrate ion
下载PDF
Detection of Cyanide in Pollution-free Livestock Product Breeding Water by Ion Chromatography 被引量:3
16
作者 Dongya HUANG Youkai PENG Jinting YAN 《Asian Agricultural Research》 2018年第1期34-36,共3页
In order to verify the accuracy of ion chromatography for cyanide detection,optimization conditions were studied,and comparison was made for the detection results of cyanide between titration and isonicotinic acid pyr... In order to verify the accuracy of ion chromatography for cyanide detection,optimization conditions were studied,and comparison was made for the detection results of cyanide between titration and isonicotinic acid pyrazolone spectrophotometry. The results showed that ion chromatography has good linearity and reproducibility,with the recovery rate of 95%-105% and the limit of detection of 0. 001 mg/L. This method is simple,rapid,safe,selective,and suitable for the determination of cyanide in pollution-free livestock product breeding water. 展开更多
关键词 ion chromatography TITRATion SPECTROPHOTOMETRY Pollution-free livestock product breeding water CYANIDE
下载PDF
Arsenic Speciation Analysis by Ion Chromatography - A Critical Review of Principles and Applications 被引量:3
17
作者 Adrian A. Ammann 《American Journal of Analytical Chemistry》 2011年第1期27-45,共19页
Multiple acute and chronic toxicity of arsenic species and its mobilisation from geological deposits into ground and drinking water resources is one of the greatest threats to human health. Arsenic speciation analy-si... Multiple acute and chronic toxicity of arsenic species and its mobilisation from geological deposits into ground and drinking water resources is one of the greatest threats to human health. Arsenic speciation analy-sis, mostly done by liquid chromatography, is a challenging task which requires an intense high quality work with respect to extraction, preservation, separation, detection and validation. A growing number of As-spe-cies and low regulatory limits (10 μg/L) may require more than one speciation method preferably performed by species specific procedures and detectors. Beside As-fractionation for special application there are many selective speciation methods based on high performance separation techniques like capillary electrophoreses, gas and liquid chromatography. Both, fractionation and speciation methods are reviewed. However, the focus is on scopes and limits of ion chromatographic separations, the most frequently used methods. Based on IC-principles the methods applied are critically discussed and recommendations given which should result in more robust and reliable As-speciation. 展开更多
关键词 Review ARSENIC SPECIATion ion chromatography
下载PDF
Separation Behavior of U(VI) and Th(IV) on a Mixed Ion Exchange Column Using 2,6-Pyridine Dicarboxylic Acid as a Complexing Agent and Determination of Trace Level Thorium in Uranium Matrix Employing High Performance Ion Chromatography 被引量:2
18
作者 Vaibhavi V. Raut S. P. Roy +2 位作者 M. K. Das S. Jeyakumar K. L. Ramakumar 《International Journal of Analytical Mass Spectrometry and Chromatography》 2013年第1期61-71,共11页
Retention behavior of U(VI) and Th(IV) as their 2, 6-pyridine dicarboxylic acid (PDCA) complexes on reversed phase and ion exchange (cation, anion and mixed ion exchange) columns was studied and based on the results, ... Retention behavior of U(VI) and Th(IV) as their 2, 6-pyridine dicarboxylic acid (PDCA) complexes on reversed phase and ion exchange (cation, anion and mixed ion exchange) columns was studied and based on the results, a simple ion chromatography method for the determination of trace level thorium in uranium oxide using 0.075mM 2, 6-pyridine dicarboxylic acid (PDCA) and 1M KNO3 in 1.2M HNO3 as eluent (flow rate 1 mL/min)was proposed. The advantage of the developed method is that the separation of uranium matrix is not required prior to the ion chromatographic determination of trace Th. Separation was carried out on a mixed ion exchange stationary phase and a 10?4 M arsenazo (III) solution was used as post column reagent for detecting the separated metal ions. The separation of Th from uranium using PDCA in the present investigation is attributed through cation exchange mechanism. A calibration plot was constructed by following the standard addition method over the concentration range of 0.25 to 10 ppm of Th in the presence of uranium matrix, which resulted in a linear regression coefficient of 0.9978. The precision of the method was better than 5% and the LOD for Th was found to be 0.1ppm (S/N=3). The method has been validated by comparing the results with the results obtained from ICP-MS analysis where the This separated from the uranium matrix. The proposed method is simple, rapid, accurate and cost effective compared to techniques like ICP-MS or ICP-AES and is suitable for the routine kind of analysis. 展开更多
关键词 ion chromatography URANIUM THORIUM 2 6-Pyridine Dicarboxylic Acid
下载PDF
Determination of toluene diisocyanate in synthetic-rubber track by ion chromatography with ultraviolet detection after alkaline suppressor 被引量:1
19
作者 Mei Lan Chen Yun Chang Fan +2 位作者 Chang An Li Dong Fei Yan Zhu 《Chinese Chemical Letters》 SCIE CAS CSCD 2009年第2期207-209,共3页
In the present work, a novel analytical method was proposed for the determination of toluene diisocyanate (TDI) in syntheticrubber track by ion chromatography (IC) coupled with an ultraviolet detector setting at 2... In the present work, a novel analytical method was proposed for the determination of toluene diisocyanate (TDI) in syntheticrubber track by ion chromatography (IC) coupled with an ultraviolet detector setting at 212 nm. TDI can be hydrolyzed to toluene diamine (TDA) which can be separated by cation-exchange IC easily. The optimum IC separation was performed on an IonPac CS12A column (150 mm ×4.0 mm) using 20 mmol L^-1 sodium sulfate, 10 mmol L^-1 sulfuric acid and 10% acetonitrile as eluent. It was found that a higher signal response of TDA could be obtained under alkaline condition. A suppressor was used to change the acidic eluent into alkaline one. 0.8 mol L^-1 potassium hydroxide was chosen as the optimum regeneration eluent. With the added suppressor and regenerant, signal response was magnified by about 16 times and lower limit of detection (LOD, 0.13 μg L^-1) was obtained. Within-day relative standard deviation (R.S.D.) was less than 3.6%. The recoveries of TDI spiked in synthetic-rubber track samoles were 96.4-110.6%. 展开更多
关键词 ion chromatography (IC) Ultraviolet detection Toluene diisocyanate (TDI)
下载PDF
Organic acids and inorganic anions in Bayer liquors by ion chromatography after solid-phase extraction 被引量:3
20
作者 钟付金 陈晓青 +1 位作者 张树朝 李跃平 《Journal of Central South University of Technology》 EI 2007年第2期191-195,共5页
A method for the simultaneous separation and determination of organic acids and inorganic anions in Bayer liquors was developed by gradient ion chromatography with suppressed conductivity detection. Formate, acetate, ... A method for the simultaneous separation and determination of organic acids and inorganic anions in Bayer liquors was developed by gradient ion chromatography with suppressed conductivity detection. Formate, acetate, propionate, oxalate, succinate, glutarate, fluoride, chloride and sulfate were separated and determined in 33 min. The samples were pretreated with solid-phase extraction, which has high selectivity for removing a large number of metallic ions in the Bayer liquors, and filtered with a 0.45 μm filter membrane before being injected into the ion chromatographic system. The separation of six organic acids and three inorganic anions was achieved on an IonPac AS11-HC column with KOH as the eluent, and the detection was performed by a conductivity detection mode. No interference is found in the presence of fluorate, chlorate and sulphate when organic acids are determined. The calibration graphs of peak area for all the analytes are linear over a wide range. The relative standard derivation of the peak area of analytes is less than 2.14%. Under optimum conditions the detection ranges from 0.2 to 100.0 mg/L. The average recoveries of the added standards are between 94.3% and 102.8%. 展开更多
关键词 Bayer liquors organic acid inorganic anion ion chromatography solid-phase extraction
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部