A simple, fast and reliable method, using high performance anion chromatography with pulsed amperometric detection, had been developed for the analysis of neomycin in water samples. The elution and separation were car...A simple, fast and reliable method, using high performance anion chromatography with pulsed amperometric detection, had been developed for the analysis of neomycin in water samples. The elution and separation were carried out with an isocratic mobile phase, containing 10 mmol/L NaOH. The influence of the concentration and pH of the mobile phase on the separation and detection was investigated. A quadruple-potential waveform used for the detection was optimized. The detection limit of neomycin was down to 0.027 μg/mL. The linearity of neomycin calibration curve ranged from 0.050 to 0.505 μg/mL with correlation coefficient of 0.9997. R.S.D. (n = 11) was 4.0%.展开更多
In this research, a glassy carbon electrode modified with the functionalized multi-wall carbon nanotubes(MWNT-COOHs) film was used as an amperometric sensor for the determination of S_2O^(2-)_3, SO^(2-)_3, I^- and SCN...In this research, a glassy carbon electrode modified with the functionalized multi-wall carbon nanotubes(MWNT-COOHs) film was used as an amperometric sensor for the determination of S_2O^(2-)_3, SO^(2-)_3, I^- and SCN^-. The electrochemical behavior of those oxidizable inorganic anions at this modified electrode was studied by means of cyclic voltammetry(CV). The experimental results indicate that the modified electrode exhibits a high electrocatalytic activity towards the oxidation of those anions with a relatively high sensitivity, a good stability and a long-life. Separated by ion chromatography(IC) with 1.25 mmol/L H_2SO_4 as an eluent, those oxidizable anions can be determined by the MWNT-COOHs modified electrode successfully. Under the optimal chromatographic conditions, the detection limits are 1.5×10^(-7) mol/L for S_2O^(2-)_3, 2.5×10^(-7) mol/L for SO^(2-)_3, 1.2×10^(-7) mol/L for I^- and 2.0×10^(-7) mol/L for SCN^-, respectively. The method was applied successfully to the determination of those anions in environmental water展开更多
In this paper, a quadruple-potential waveform was investigated and optimized for the determination of gentamicin by reversed phase ion-pair chromatography. Instead of a relatively high positive potential, a negative p...In this paper, a quadruple-potential waveform was investigated and optimized for the determination of gentamicin by reversed phase ion-pair chromatography. Instead of a relatively high positive potential, a negative potential was adopted as a potential for the cleaning of gold working electrode. By this way, the formation of gold oxide resulting from the application of high positive potential during the analyte detection and electrode cleaning was greatly reduced, and therefore, the dissolution and recession of gold working electrode was also reduced. The good condition of gold working electrode achieved by this quadruple-potential waveform can help us to obtain a good reproducibility. In order to acquire signal-to-noise ratio as high as possible, several waveform parameters affecting the detection of gentamicin were carefully selected. The analytical method has been applied to the determination of two real gentamicin samples, and good results with low relative standard deviation not more than 4% were obtained.展开更多
文摘A simple, fast and reliable method, using high performance anion chromatography with pulsed amperometric detection, had been developed for the analysis of neomycin in water samples. The elution and separation were carried out with an isocratic mobile phase, containing 10 mmol/L NaOH. The influence of the concentration and pH of the mobile phase on the separation and detection was investigated. A quadruple-potential waveform used for the detection was optimized. The detection limit of neomycin was down to 0.027 μg/mL. The linearity of neomycin calibration curve ranged from 0.050 to 0.505 μg/mL with correlation coefficient of 0.9997. R.S.D. (n = 11) was 4.0%.
基金supported by the National Natural Science Foundation of China(No.2 0 175 0 0 6 ) and Nano Projects from Shanghai Sci-ence and Technology Com mittee(No.0 2 14 nm0 78and0 35 9nm0 0 2 )
文摘In this research, a glassy carbon electrode modified with the functionalized multi-wall carbon nanotubes(MWNT-COOHs) film was used as an amperometric sensor for the determination of S_2O^(2-)_3, SO^(2-)_3, I^- and SCN^-. The electrochemical behavior of those oxidizable inorganic anions at this modified electrode was studied by means of cyclic voltammetry(CV). The experimental results indicate that the modified electrode exhibits a high electrocatalytic activity towards the oxidation of those anions with a relatively high sensitivity, a good stability and a long-life. Separated by ion chromatography(IC) with 1.25 mmol/L H_2SO_4 as an eluent, those oxidizable anions can be determined by the MWNT-COOHs modified electrode successfully. Under the optimal chromatographic conditions, the detection limits are 1.5×10^(-7) mol/L for S_2O^(2-)_3, 2.5×10^(-7) mol/L for SO^(2-)_3, 1.2×10^(-7) mol/L for I^- and 2.0×10^(-7) mol/L for SCN^-, respectively. The method was applied successfully to the determination of those anions in environmental water
基金Project supported by the Major State Basic Research Development Program (No. 2003CB415001) of China and the National Natural Science Foundation of China (No. 20475060).
文摘In this paper, a quadruple-potential waveform was investigated and optimized for the determination of gentamicin by reversed phase ion-pair chromatography. Instead of a relatively high positive potential, a negative potential was adopted as a potential for the cleaning of gold working electrode. By this way, the formation of gold oxide resulting from the application of high positive potential during the analyte detection and electrode cleaning was greatly reduced, and therefore, the dissolution and recession of gold working electrode was also reduced. The good condition of gold working electrode achieved by this quadruple-potential waveform can help us to obtain a good reproducibility. In order to acquire signal-to-noise ratio as high as possible, several waveform parameters affecting the detection of gentamicin were carefully selected. The analytical method has been applied to the determination of two real gentamicin samples, and good results with low relative standard deviation not more than 4% were obtained.