期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Modeling of Inner Surface Modification of a Cylindrical Tube by Plasma-Based Low-Energy Ion Implantation
1
作者 郑博聪 王克胜 雷明凯 《Plasma Science and Technology》 SCIE EI CAS CSCD 2015年第4期309-316,共8页
The inner surface modification process by plasma-based low-energy ion implantation(PBLEII)with an electron cyclotron resonance(ECR)microwave plasma source located at the central axis of a cylindrical tube is model... The inner surface modification process by plasma-based low-energy ion implantation(PBLEII)with an electron cyclotron resonance(ECR)microwave plasma source located at the central axis of a cylindrical tube is modeled to optimize the low-energy ion implantation parameters for industrial applications.In this paper,a magnetized plasma diffusion fluid model has been established to describe the plasma nonuniformity caused by plasma diffusion under an axial magnetic field during the pulse-off time of low pulsed negative bias.Using this plasma density distribution as the initial condition,a sheath collisional fluid model is built up to describe the sheath evolution and ion implantation during the pulse-on time.The plasma nonuniformity at the end of the pulse-off time is more apparent along the radial direction compared with that in the axial direction due to the geometry of the linear plasma source in the center and the difference between perpendicular and parallel plasma diffusion coefficients with respect to the magnetic field.The normalized nitrogen plasma densities on the inner and outer surfaces of the tube are observed to be about 0.39 and 0.24,respectively,of which the value is 1 at the central plasma source.After a 5μs pulse-on time,in the area less than 2 cm from the end of the tube,the nitrogen ion implantation energy decreases from 1.5 keV to 1.3 keV and the ion implantation angle increases from several degrees to more than 40°;both variations reduce the nitrogen ion implantation depth.However,the nitrogen ion implantation dose peaks of about 2×10^(10)-7×10^(10)ions/cm^2 in this area are 2-4 times higher than that of 1.18×10^(10)ions/cm^2 and 1.63×10^(10)ions/cm^2 on the inner and outer surfaces of the tube.The sufficient ion implantation dose ensures an acceptable modification effect near the end of the tube under the low energy and large angle conditions for nitrogen ion implantation,because the modification effect is mainly determined by the ion implantation dose,just as the mass transfer process in PBLEII is dominated by low-energy ion implantation and thermal diffusion.Therefore,a comparatively uniform surface modification by the low-energy nitrogen ion implantation is achieved along the cylindrical tube on both the inner and outer surfaces. 展开更多
关键词 plasma-based low-energy ion implantation inner surface modification magnetized plasma diffusion fluid model sheath collisional fluid model
下载PDF
Durability of sea-sand containing concrete:Effects of chloride ion penetration 被引量:12
2
作者 Yin Huiguang Li Yan +1 位作者 Lv Henglin Gao Quan 《Mining Science and Technology》 EI CAS 2011年第1期123-127,共5页
This paper describes an orthogonal experiment on the effect of water/cement ratio,water consumption per cubic meter,curing time,and type of sand on the response"resistance to chloride ion penetration".A sea-sand con... This paper describes an orthogonal experiment on the effect of water/cement ratio,water consumption per cubic meter,curing time,and type of sand on the response"resistance to chloride ion penetration".A sea-sand containing concrete was used for the trials.An analysis of chloride ion diffusion coefficients at different factor levels was performed.A predictive model of chloride ion diffusion in concrete is developed through regression analysis.The experimental results show that when the water/cement ratio varies from 0.45 to 0.60,and the water consumption per cubic meter varies from 185 to 215 kg,and the curing time varies from 30 to 180 d then the size of the effects fall in the order(most significant first): curing time,type of sand,water consumption per cubic meter,and water/cement ratio.Chloride ion penetration is reduced,and better durability of the concrete is observed,with longer curing times,less water consumption per cubic meter,and a smaller water/cement ratio. 展开更多
关键词 Sea-sand concrete Durability Chloride ion diffusion coefficient Predictive model
下载PDF
空心纳米柱状电极力-扩散耦合行为研究
3
作者 李广明 詹春晓 李孝宝 《合肥工业大学学报(自然科学版)》 CAS 北大核心 2023年第7期950-956,共7页
文章以纳米尺度离子电池的电极结构为研究对象,建立可考虑表面效应的力-扩散双向耦合理论模型,对其在表面效应和外部载荷作用下的力学响应行为进行系统研究。借助建立的理论模型,研究尺寸效应、表面效应等对恒电压充电条件下空心纳米柱... 文章以纳米尺度离子电池的电极结构为研究对象,建立可考虑表面效应的力-扩散双向耦合理论模型,对其在表面效应和外部载荷作用下的力学响应行为进行系统研究。借助建立的理论模型,研究尺寸效应、表面效应等对恒电压充电条件下空心纳米柱状电极中浓度场、应力场分布规律的影响并分析其内在机制。研究发现在该文条件下,表面效应对电极中环向和轴向应力场有压应力作用,且尺寸越小压应力作用越明显,而对径向应力场的作用则与位置有关。该研究为优化空心纳米柱状电极中的力-扩散耦合行为性能及应用拓展提供了一定的理论基础和参考依据。 展开更多
关键词 锂离子 纳米电极 力-扩散耦合模型 表面效应 恒电压充电
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部