The inner surface modification process by plasma-based low-energy ion implantation(PBLEII)with an electron cyclotron resonance(ECR)microwave plasma source located at the central axis of a cylindrical tube is model...The inner surface modification process by plasma-based low-energy ion implantation(PBLEII)with an electron cyclotron resonance(ECR)microwave plasma source located at the central axis of a cylindrical tube is modeled to optimize the low-energy ion implantation parameters for industrial applications.In this paper,a magnetized plasma diffusion fluid model has been established to describe the plasma nonuniformity caused by plasma diffusion under an axial magnetic field during the pulse-off time of low pulsed negative bias.Using this plasma density distribution as the initial condition,a sheath collisional fluid model is built up to describe the sheath evolution and ion implantation during the pulse-on time.The plasma nonuniformity at the end of the pulse-off time is more apparent along the radial direction compared with that in the axial direction due to the geometry of the linear plasma source in the center and the difference between perpendicular and parallel plasma diffusion coefficients with respect to the magnetic field.The normalized nitrogen plasma densities on the inner and outer surfaces of the tube are observed to be about 0.39 and 0.24,respectively,of which the value is 1 at the central plasma source.After a 5μs pulse-on time,in the area less than 2 cm from the end of the tube,the nitrogen ion implantation energy decreases from 1.5 keV to 1.3 keV and the ion implantation angle increases from several degrees to more than 40°;both variations reduce the nitrogen ion implantation depth.However,the nitrogen ion implantation dose peaks of about 2×10^(10)-7×10^(10)ions/cm^2 in this area are 2-4 times higher than that of 1.18×10^(10)ions/cm^2 and 1.63×10^(10)ions/cm^2 on the inner and outer surfaces of the tube.The sufficient ion implantation dose ensures an acceptable modification effect near the end of the tube under the low energy and large angle conditions for nitrogen ion implantation,because the modification effect is mainly determined by the ion implantation dose,just as the mass transfer process in PBLEII is dominated by low-energy ion implantation and thermal diffusion.Therefore,a comparatively uniform surface modification by the low-energy nitrogen ion implantation is achieved along the cylindrical tube on both the inner and outer surfaces.展开更多
This paper describes an orthogonal experiment on the effect of water/cement ratio,water consumption per cubic meter,curing time,and type of sand on the response"resistance to chloride ion penetration".A sea-sand con...This paper describes an orthogonal experiment on the effect of water/cement ratio,water consumption per cubic meter,curing time,and type of sand on the response"resistance to chloride ion penetration".A sea-sand containing concrete was used for the trials.An analysis of chloride ion diffusion coefficients at different factor levels was performed.A predictive model of chloride ion diffusion in concrete is developed through regression analysis.The experimental results show that when the water/cement ratio varies from 0.45 to 0.60,and the water consumption per cubic meter varies from 185 to 215 kg,and the curing time varies from 30 to 180 d then the size of the effects fall in the order(most significant first): curing time,type of sand,water consumption per cubic meter,and water/cement ratio.Chloride ion penetration is reduced,and better durability of the concrete is observed,with longer curing times,less water consumption per cubic meter,and a smaller water/cement ratio.展开更多
基金supported by National Natural Science Foundation of China(Nos.50725519,51271048,51321004)
文摘The inner surface modification process by plasma-based low-energy ion implantation(PBLEII)with an electron cyclotron resonance(ECR)microwave plasma source located at the central axis of a cylindrical tube is modeled to optimize the low-energy ion implantation parameters for industrial applications.In this paper,a magnetized plasma diffusion fluid model has been established to describe the plasma nonuniformity caused by plasma diffusion under an axial magnetic field during the pulse-off time of low pulsed negative bias.Using this plasma density distribution as the initial condition,a sheath collisional fluid model is built up to describe the sheath evolution and ion implantation during the pulse-on time.The plasma nonuniformity at the end of the pulse-off time is more apparent along the radial direction compared with that in the axial direction due to the geometry of the linear plasma source in the center and the difference between perpendicular and parallel plasma diffusion coefficients with respect to the magnetic field.The normalized nitrogen plasma densities on the inner and outer surfaces of the tube are observed to be about 0.39 and 0.24,respectively,of which the value is 1 at the central plasma source.After a 5μs pulse-on time,in the area less than 2 cm from the end of the tube,the nitrogen ion implantation energy decreases from 1.5 keV to 1.3 keV and the ion implantation angle increases from several degrees to more than 40°;both variations reduce the nitrogen ion implantation depth.However,the nitrogen ion implantation dose peaks of about 2×10^(10)-7×10^(10)ions/cm^2 in this area are 2-4 times higher than that of 1.18×10^(10)ions/cm^2 and 1.63×10^(10)ions/cm^2 on the inner and outer surfaces of the tube.The sufficient ion implantation dose ensures an acceptable modification effect near the end of the tube under the low energy and large angle conditions for nitrogen ion implantation,because the modification effect is mainly determined by the ion implantation dose,just as the mass transfer process in PBLEII is dominated by low-energy ion implantation and thermal diffusion.Therefore,a comparatively uniform surface modification by the low-energy nitrogen ion implantation is achieved along the cylindrical tube on both the inner and outer surfaces.
基金This project owes gratitude to the Science and Technology Project (No.2008-K4-27) of Ministry of Housing and Urban-Rural Developmentthe"Tralented Personnel Nurturing in Six Fundamental Fields"Project of Jiangsu Province and"Qing-Lan Project"+2 种基金the Science and Technology Project of Jiangsu Bureau of Construction and Supervision (No.JG2007-13)the Science and Technology Planning Project of Xuzhou City(No.XJ08077)the Scientific Research Project of Xuzhou Institute of Technology(No.XKY2008225).
文摘This paper describes an orthogonal experiment on the effect of water/cement ratio,water consumption per cubic meter,curing time,and type of sand on the response"resistance to chloride ion penetration".A sea-sand containing concrete was used for the trials.An analysis of chloride ion diffusion coefficients at different factor levels was performed.A predictive model of chloride ion diffusion in concrete is developed through regression analysis.The experimental results show that when the water/cement ratio varies from 0.45 to 0.60,and the water consumption per cubic meter varies from 185 to 215 kg,and the curing time varies from 30 to 180 d then the size of the effects fall in the order(most significant first): curing time,type of sand,water consumption per cubic meter,and water/cement ratio.Chloride ion penetration is reduced,and better durability of the concrete is observed,with longer curing times,less water consumption per cubic meter,and a smaller water/cement ratio.