期刊文献+
共找到83,993篇文章
< 1 2 250 >
每页显示 20 50 100
Determination of Organic Acids in Root Exudates by High Performance Liquid Chromatography: I. Development and Assessment of Chromatographic Conditions *1 被引量:4
1
作者 SHENJIANBO ZHANGFUSUO 《Pedosphere》 SCIE CAS CSCD 1998年第2期97-104,共8页
Methods for determining nine low molecular weight organic acids in root exudates were developed by using reversed phase high performance liquid chromatography with UV (ultraviolet) detection at 214 nm. The mobile ph... Methods for determining nine low molecular weight organic acids in root exudates were developed by using reversed phase high performance liquid chromatography with UV (ultraviolet) detection at 214 nm. The mobile phase was 18 mmol L -1 kH 2PO 4 adjusted to pH 2.25 with phosphoric acid and the flow rate was 0.3 mL min -1 . The analytical column was a reversed phase silica based C 18 column (Shim pack CLC ODS). The root exudates were collected through submerging the whole root system into aerated deionized water for 2 hours. The filtered exudate solutions were concentrated to dryness by rotary evaporation at 40 °C, dissolved in 10 mL mobile phase. The chromatographic conditions of organic acid determination were analyzed. The results showed that there was a high selectivity and sensitivity in the organic acid determination by reversed phase high performance liquid chromatography. Coefficients of variation for organic acid determination were lower than 10% except lactic acid. The recoveries were consistently between 80.1% to 108.3%. Detection limits were approximately 0.05 to 4.5 mg L -1 for organic acids except succinic acid with the detection limit of 7.0 mg L -1 . Phosphorus deficiency may contribute to the release of organic acids in soybean root exudates especially malic, lactic and citric acids. 展开更多
关键词 high performance liquid chromatography organic acids root exudates SOYBEAN
下载PDF
MODELLING OF MECHANICAL MECHANISM OF CHROMATOGRAPHIC SYSTEM AND THEORETICAL EQUATIONS SHOWING DYNAMICAL CHARACTERISTICS OF CHROMATOGRAPHY
2
作者 Wei Qun DENG, Jin Fa YANG Fujian Geological Analysis and Testing Research Center,Fuzhou,350002 Yun DENG Department of Chemical Engineering, University of Waterloo, Canada N2L 3GI 《Chinese Chemical Letters》 SCIE CAS CSCD 1992年第7期547-550,共4页
A simple model of chromatographic mechanical mechanism is present, and then a scrics of theoretical chromatographic equations and fundamental Formulae are derived. These theoretical equations and formulae not only res... A simple model of chromatographic mechanical mechanism is present, and then a scrics of theoretical chromatographic equations and fundamental Formulae are derived. These theoretical equations and formulae not only reserve thermodynamic characteristics in the current fundamental chromatographic formulae, but also introduce one or more kinetic parameter, so it is possible to make the macroscopic-control on the effect of kinetic characteristics on chromatographic system. 展开更多
关键词 MODELLING OF MECHANICAL MECHANISM OF CHROMATOGRAPHIC SYSTEM AND THEORETICAL EQUATIONS SHOWING DYNAMICAL CHARACTERISTICS OF chromatography 月山
下载PDF
Gas Chromatographic Method for Identification and Quantification of Commonly Used Residual Solvents in Pharmaceuticals Products
3
作者 Sreekanta Nath Dalal Pranab Kumar Das 《American Journal of Analytical Chemistry》 CAS 2024年第8期241-252,共12页
Background: Impurities are not expected in the final pharmaceutical products. All impurities should be regulated in both drug substances and drug products in accordance with pharmacopeias and ICH guidelines. Three dif... Background: Impurities are not expected in the final pharmaceutical products. All impurities should be regulated in both drug substances and drug products in accordance with pharmacopeias and ICH guidelines. Three different types of impurities are generally available in the pharmaceutical’s product specification: organic impurities, inorganic impurities, and residual solvents. Residual solvents are organic volatile chemicals used or generated during the manufacturing of drug substances or drug products. Purpose: The aim of this study is to develop a cost-effective gas chromatographic method for the identification and quantification of some commonly used solvents—methanol, acetone, isopropyl alcohol (IPA), methylene chloride, ethyl acetate, tetrahydrofuran (THF), benzene, toluene, and pyridine—in pharmaceutical product manufacturing. This method will be able to identify and quantify the multiple solvents within a single gas chromatographic procedure. Method: A gas chromatography (GC) equipped with a headspace sampler and a flame ionization detector, and a column DB 624, 30-meter-long × 0.32-millimeter internal diameter, 1,8 μm-thick, Brand-Agilent was used to develop this method. The initial GC oven temperature was 40°C and held for 5 minutes. It was then increase to 80˚C at a rate of 2˚C per minute, followed by a further increase to 225˚C at a rate of 30˚C per minute, with a final hold at 225˚C for 10 minutes. Nitrogen was used as a carrier gas at a flow rate of 1.20 mL per minute. Dimethyl sulfoxide (DMSO) was selected as sample solvent. Results: The developed method is precise and specific. The percent RSD for the areas of six replicate injections of this gas chromatographic method was within 10.0 and the recovery result found within 80.0% to 120.0%. 展开更多
关键词 Method Development Gas chromatography Compendial Method GDP SPECIFICITY RECOVERY
下载PDF
Simultaneous purification of minor components in natural products using twin-column recycling chromatography with a step solvent gradient
4
作者 Guangxia Jin Yuxue Wu Feng Wei 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2024年第5期212-219,共8页
The isolation of minor components from complex natural product matrices presents a significant challenge in the field of purification science due to their low concentrations and the presence of structurally similar co... The isolation of minor components from complex natural product matrices presents a significant challenge in the field of purification science due to their low concentrations and the presence of structurally similar compounds.This study introduces an optimized twin-column recycling chromatography method for the efficient and simultaneous purification of these elusive constituents.By introducing water at a small flowing rate between the twin columns,a step solvent gradient is created,by which the leading edge of concentration band would migrate at a slower rate than the trailing edge as it flowing from the upstream to downstream column.Hence,the band broadening is counterbalanced,resulting in an enrichment effect for those minor components in separation process.Herein,two target substances,which showed similar peak position in high performance liquid chromatography(HPLC)and did not exceed 1.8%in crude paclitaxel were selected as target compounds for separation.By using the twin-column recycling chromatography with a step solvent gradient,a successful purification was achieved in getting the two with the purity almost 100%.We suggest this method is suitable for the separation of most components in natural produces,which shows higher precision and recovery rate compared with the common lab-operated separation ways for natural products(thin-layer chromatography and prep-HPLC). 展开更多
关键词 Solvent gradient Twin-column recycling chromatography PURIFICATION Minor component Natural products
下载PDF
Determination of 14 Organophosphorus Pesticide Residues in Mutton by Gel Permeation Chromatography-Gas Chromatography-Mass Spectrometry(GPC-GC-MS)
5
作者 Junpeng ZHAO Richard Avoi +2 位作者 Azman Bin Atil@Azmi Jiao CHEN Ling YUN 《Agricultural Biotechnology》 2024年第3期28-30,33,共4页
[Objectives]This study was conducted to purify mutton samples by gel permeation chromatography(GPC).[Methods]Fourteen organophosphorus pesticide residues in samples were qualitatively and quantitatively analyzed by ga... [Objectives]This study was conducted to purify mutton samples by gel permeation chromatography(GPC).[Methods]Fourteen organophosphorus pesticide residues in samples were qualitatively and quantitatively analyzed by gas chromatography-mass spectrometry(GC-MS)in selective ion scanning mode(SIM).[Results]The organophosphorus pesticide standard solutions showed good linearity in the mass concentration range of 0.1-10.0μg/ml with correlation coefficients(r)not lower than 0.999,and the detection limits(S=3 N)ranged from 0.01 to 0.05 mg/kg.The average recovery values were in the range of 80.2%-99.7%,with relative standard deviations(RSDs,n=3)in the range of 1.8%-6.3%,at the addition levels of 0.5,1.0 and 2.0 mg/kg.[Conclusions]The method is simple,sensitive and accurate,and can be used for the determination of organophosphorus pesticide residues in mutton. 展开更多
关键词 MUTTON Gas chromatography-mass spectrometry Gel permeation chromatography ORGANOPHOSPHORUS Pesticide residue
下载PDF
Comprehensive analysis of phenolic composition and antioxidant mechanisms in Gymnema sylvestre extracts using LC-MS and column chromatography
6
作者 Shengjie Hao Yuxin Du +2 位作者 Jianglong He Qian Li Guilin Chen 《Asian Journal of Traditional Medicines》 2024年第4期211-222,共12页
Recent studies have highlighted the potential of plant extracts as therapeutic agents for managing oxidative stress and related disorders.This study aims to elucidate the phenolic composition and antioxidant propertie... Recent studies have highlighted the potential of plant extracts as therapeutic agents for managing oxidative stress and related disorders.This study aims to elucidate the phenolic composition and antioxidant properties of Gymnema sylvestre extracts.Ethanolic reflux extraction followed by column chromatography was employed to isolate phenolic compounds.The total phenolic and flavonoid contents were quantified using the Folin–Ciocalteu and aluminum chloride colorimetric methods,respectively.Antioxidant activities were assessed by DPPH,ABTS scavenging assays and the ferric reducing antioxidant power(FRAP)assay.High-Performance Liquid Chromatography(HPLC)with a C18 column and Thermo TSQ Quantum Access Max(LC-MS)were used to determine the levels of gymnemic acid and identify other potential phenolic compounds.The analysis revealed significant antioxidant activities in the fractions.Fraction A showed the highest DPPH and ABTS scavenging activities,and Fraction C demonstrated the highest ferric reducing power.LC-MS analysis identified several phenolic compounds,indicating that these are major contributors to the antioxidant efficacy of the extract.This study provides a detailed phenolic profile and confirms the strong antioxidant potential of Gymnema sylvestre leaf extract,supporting its therapeutic use and further investigation. 展开更多
关键词 Gymnema sylvestre ANTIOXIDANTS column chromatography phenolic compounds LC-MS
下载PDF
Determination of Benzo[a]pyrene in Edible Oil by High Performance Liquid Chromatography-Fluorescence Detector (HPLC-FL)
7
作者 Guixia YANG Jie LIU +3 位作者 Xiujuan WANG Fenglan ZHANG Kun XIN Chunli KONG 《Agricultural Biotechnology》 2024年第2期8-9,19,共3页
In this study, an optimized high performance liquid chromatography-fluorescence detector (HPLC-FL) method for the determination of benzo[a]pyrene in edible oil was established. HPLC was performed with Thermo Fisher Sc... In this study, an optimized high performance liquid chromatography-fluorescence detector (HPLC-FL) method for the determination of benzo[a]pyrene in edible oil was established. HPLC was performed with Thermo Fisher Scientific C18 column (250 mm×4.6 mm, 5 μm) as the chromatographic column and acetonitrile and water as the mobile phase, and the excitation wavelength and emission wavelength of fluorescence detector were 286 and 430 nm, respectively. The response was high, and the linear range was 0.5-10.0 ng/ml. The lowest limit of detection was 0.11 ng/ml, and the average recovery was 92.5%. This method is suitable for quantitative analysis of benzo[a]pyrene content in edible oil. 展开更多
关键词 BENZO[A]PYRENE High performance liquid chromatography Fluorescence detector
下载PDF
离子色谱技术研究进展
8
作者 关宁昕 孔淮 王萍丽 《中国无机分析化学》 北大核心 2025年第2期210-217,共8页
离子色谱技术作为分析无机离子的首选方法,还可实现小分子极性化合物、氨基酸、糖类等生物样品的分析。近年来,离子色谱技术快速发展,广泛应用在环境监测、食品分析、生物医药、农业、地质等多个领域。针对离子色谱技术的综述多是探讨... 离子色谱技术作为分析无机离子的首选方法,还可实现小分子极性化合物、氨基酸、糖类等生物样品的分析。近年来,离子色谱技术快速发展,广泛应用在环境监测、食品分析、生物医药、农业、地质等多个领域。针对离子色谱技术的综述多是探讨离子色谱技术在环境、烟草、药品、食品等领域的应用进展,而关注离子色谱技术发展动态的研究报道相对较少。专利文献蕴含科技文献未曾报道的技术研发信息,对于归纳总结前沿技术走向具有重要意义。基于全球范围内离子色谱相关技术专利数据,从淋洗液发生装置、色谱柱固定相、离子色谱抑制器、检测器等方面综述离子色谱分析技术的研究进展,旨为国内离子色谱技术创新发展提供参考与依据。研究表明,全球离子色谱技术研究发展迅速,核心技术及基础研究主要分布在美国和日本,超高压淋洗液发生器、优化供电方式的自动再生电解抑制器及温控稳定的检测器是离子色谱领域新近研究方向,围绕固定相的研究侧重于提高离子交换容量,提高分析速度,改善离子色谱柱效、选择性与亲水性等方面性能。 展开更多
关键词 离子色谱 淋洗液发生装置 色谱柱固定相 抑制器 电导率检测器
下载PDF
Study on the Chromatographic Fingerprint of Volatile Constituents from Acacia Honey 被引量:19
9
作者 夏立娅 张晓宇 +1 位作者 王庭欣 马英松 《Agricultural Science & Technology》 CAS 2010年第6期42-44,共3页
[Objective] The experiment aimed to study chromatographic fingerprint in volatile components of acacia honey and provide scientific evaluation and effective control on quality of acacia honey.[Method] Using solid-phas... [Objective] The experiment aimed to study chromatographic fingerprint in volatile components of acacia honey and provide scientific evaluation and effective control on quality of acacia honey.[Method] Using solid-phase microextraction method to separate and detect volatile components and construct chromatographic fingerprint.[Result] The honey was preheated for 15 min in water bath at 40 ℃ and solid-phase microextraction 85 μmPA was used to extract in overhead air about 30 min,then put it into the injector and desorpted 3 min,which is in 230 ℃.The Supelco WaxTM10 30 m×0.25 mm×0.25 μm column and gradient heating program was the best method to separate volatile components from honey.83 fingerprint peaks were constructed,among which 17 common fingerprint peaks were comprised of chromatographic fingerprint of volatile components of acacia honey.[Conclusion] The chromatographic fingerprint could provide reference for quality control of acacia honey. 展开更多
关键词 HONEY Volatile components Solid-phase microextraction technology Gas chromatography Fingerprint.
下载PDF
Simultaneous Determination of Tetramethylpyrazine and Aspirin in a New Compound Formulation by Liquid Chromatography 被引量:2
10
作者 王鹏 齐美玲 +1 位作者 周莉 方林 《Journal of Chinese Pharmaceutical Sciences》 CAS 2004年第1期58-62,共5页
Aim To establish a reversed-phase liquid chromatographic (LC) method forsimultaneous determination of tetramethylpyrazine (TMP) and aspirin in a new compound formulation.Methods Chromatographic separation of the two d... Aim To establish a reversed-phase liquid chromatographic (LC) method forsimultaneous determination of tetramethylpyrazine (TMP) and aspirin in a new compound formulation.Methods Chromatographic separation of the two drugs was achieved on a Diamonsil C_(18) column, usinga binary mixture of methanol-1.5% acetic acid (35:65, V/V, pH = 3.1) as mobile phase at a flow rateof 1.0 mL·min^(-1). Results Separation was completed in less than 12 min. Benzoic acid was used asthe internal standard. Recoveries at levels corresponding to 80 % to 120 % of the label claim ofthe formulation ranged from 99.6 to 100.3 % for aspirin and from 99.9 to 101.3% for TMP. The linearrange was 12.6 - 150.9 μg·mL^(-1)(r= 0.9997, n = 5) for aspirin and 25.0- 300.0 μg·mL^(-1) (r =0.9999, n = 5) for TMP. Conclusion The method developed can be used for the simultaneousdetermination of TMP and aspirin in pharmaceutical preparations. 展开更多
关键词 liquid chromatography TETRAMETHYLPYRAZINE ASPIRIN ASSAY
下载PDF
Gel Filtration Chromatography Combined with Bradford Method for Determination of Total Residual Protein in Ferment Antibiotics 被引量:6
11
作者 许明哲 马仕洪 胡昌勤 《Journal of Chinese Pharmaceutical Sciences》 CAS 2004年第4期262-266,共5页
Aim A novel method has been developed for evaluation of the levels of total residual protein in antibiotics produced by fermentation using gel filtration chromatography (GFC) combined with Bradford assay based on dete... Aim A novel method has been developed for evaluation of the levels of total residual protein in antibiotics produced by fermentation using gel filtration chromatography (GFC) combined with Bradford assay based on determination of residual protein in lincomycin hydrochloride. Methods The chromatographic conditions were SuperdexTM peptide column, 0.01 mol*L-1 phosphate buffer solution as mobile phase, and flow rate of 1 mL·min-1. Five hundred microliters of lincomycin hydrochloride solution (3 g of lincomycin hydrochloride dissolved in 10 mL of mobile phase) was injected into the chromatograph and the eluted solution was collected between 6 min and 14.5 min (protein eluted from column within this period), and the residual content of total protein in the eluted solution was assayed using Bradford assay method. Results The average recovery was more than 90% for bovine serum albumin, the calibration equation for the range of 0-12 μg·mL-1 of protein was y=-0.002 4x2+0.064 2x+0.002 9, r2=0.999 9, RSD=0.1%-0.9%, and the LOD and LOQ were 3 and 10 ng·mL-1 of protein, respectively. Conclusion The novel method for determining the residual protein in ferment antibio-tics is simple, rapid, and precise. 展开更多
关键词 Gel filtration chromatography bradford assay residual protein ferment antibiotics lincomycin hydrochloride
下载PDF
Analysis of Sugar Components of Fermented Rice Wine by Ion Chromatography 被引量:2
12
作者 蔡柳 苏小军 熊兴耀 《Agricultural Science & Technology》 CAS 2013年第10期1500-1502,共3页
[Objective] The aim was to analyze sugar components in fermented rice wine by ion chromatography. [Method] The optimal condition for chromatography system of sugar analysis was selected by measuring sugars in fermente... [Objective] The aim was to analyze sugar components in fermented rice wine by ion chromatography. [Method] The optimal condition for chromatography system of sugar analysis was selected by measuring sugars in fermented rice wine with ion chromatography and pulsed amperometric detection. [Result] The optimal measurement conditions were as follows: Leacheate (Leachate), consisting of NaOH and CH3COONa, was eluted by gradient concentrations, with column temperature at 35 ℃ and flow rate at 0.4 ml/min. In the condition, sugars in rice wine were ana- lyzed and the results showed that the method is featured by low detection limit, good repetition and high recovery rate. [Conclusion] The research establishes and determines the approaches and optimum conditions for sugar analysis in rice wine by ion chromatography and pulsed amperometric detection, providing references for advancement of research on quality improvement of fermented rice wine. 展开更多
关键词 Rice wine Ion chromatography FERMENTATION
下载PDF
Determination of Dichlofluanid Residue in Soybean by Capillary Collumns Gas Chromatography 被引量:20
13
作者 邵栋梁 《Agricultural Science & Technology》 CAS 2010年第3期7-8,64,共3页
A method for the determination of dichlofluanid residue by Capillary Collumns Gas Chromatography was established in this study.Samples were extracted with acetone and subjected to through liquid-liquid extraction with... A method for the determination of dichlofluanid residue by Capillary Collumns Gas Chromatography was established in this study.Samples were extracted with acetone and subjected to through liquid-liquid extraction with N-hexane,and then they were cleanup with column that filled with florisil,subsequently separated by Capillary Column Gas Chromatography,and the electron capture detector (ECD) was used for detection.The detection limit of this method was 0.005 mg/kg (S/N=3),and this method was rapid,sensitive and accurate,and was applied in the determination of dichlofluanid residue in soybean. 展开更多
关键词 Dichlofluanid Capillary Collumns Gas chromatography SOYBEAN
下载PDF
Classification of Chinese Traditional Drug-"Beimu" (Bulbus Fritillariae) by Pyrolysis High Resolution Gas Chromatography-Pattern Recognition 被引量:2
14
作者 房杏春 李萍 +1 位作者 田琳 安登魁 《Journal of Chinese Pharmaceutical Sciences》 CAS 1992年第2期65-72,共8页
The combination of pyrolysis high resolution gas chromatography and pat- tern recognition techniques is a powerful tool for the classification of traditional Chinese drug.A study has been completed on 55 Beimu samples... The combination of pyrolysis high resolution gas chromatography and pat- tern recognition techniques is a powerful tool for the classification of traditional Chinese drug.A study has been completed on 55 Beimu samples of five different geographic origins: Eastern China.Central China.South-western China,North-western China and North-eastern China.Principal component analysis and SIMCA are applied to effectively classifying the samples according to the origin of the plants.The chemical information contained in the high resolution gas chromatographic data is sufficient to characterize the geographic origin of sam- pies. 展开更多
关键词 Beimu FRITILLARIA Pyrolysis High Resolution Gas chromatography Pattern Recognition
下载PDF
Determination of phthalate esters in fat-containing foods by packed nanofiber solid-phase extraction column and gas chromatography 被引量:2
15
作者 邱金丽 王羽 +1 位作者 周小玲 康学军 《Journal of Southeast University(English Edition)》 EI CAS 2016年第3期322-326,共5页
A new method for simultaneous determination of four phthalate esters ( PAEs) in commercial fat-containing foods was developed by the combination of a packed nanofibers column based on solid-phase extraction with gas... A new method for simultaneous determination of four phthalate esters ( PAEs) in commercial fat-containing foods was developed by the combination of a packed nanofibers column based on solid-phase extraction with gas chromatography-flame ionization detector ( GC-FID ). Conditions for obtaining optimum extraction efficiency such as extraction solvents, morphologies of adsorbent, ion strength and pH were investigated and optimized in detail. Under the optimized conditions, the limits of detection (LODs) found for dibutyl phthalate (DBP) , butyl benzyl phthalate (BBP), diethyl hexyl phthalate (DEHP) and di-n-octyl phthalate (DNOP) were 50, 25, 50 and 25 ng/g, respectively. Good linearity of four PAEs was achieved in the range of 50 to 4 000 ng/g. The proposed method was applied for analyzing different kinds of fat-containing samples. PAEs in commercial fat-containing samples can be highly extracted by a packed solid-phase extraction column of 5 mg polystyrene ( PS) nanofibers. The satisfactory average recoveries were obtained in the range of 96. 7% to 102. 3% , and the relative standard deviations (RSDs) below 5% were achieved. The proposed method reduces the organic solvent consumption, the complex and tedious procedures for sample pretreatment, and achieves high sensitivity and reproducibility for the investigated PAEs. 展开更多
关键词 phthalate esters (PAEs nanofibers solid-phase extraction gas chromatography fat-containing foods
下载PDF
High Performance Liquid Chromatography-Electrospray Ionization-Mass Spectrometric Analysis of Bilobalide and Ginkgolides in Ginkgo biloba L. Leaves 被引量:1
16
作者 卢定强 韦萍 +1 位作者 欧阳平凯 陈钧 《Journal of Chinese Pharmaceutical Sciences》 CAS 2002年第2期26-30,共5页
The ginkgo terpenoids including bilobalide and ginkgolides are the main pharmaceutical components in the leaves or extracts of Ginkgo biloba L. In this paper, the analysis of bilobalide and ginkgolides in leaves of Gi... The ginkgo terpenoids including bilobalide and ginkgolides are the main pharmaceutical components in the leaves or extracts of Ginkgo biloba L. In this paper, the analysis of bilobalide and ginkgolides in leaves of Ginkgo biloba L. by high performance liquid chromatography (HPLC)-electrospray ionization (ESI)-mass spectrometry (MS) was carried out. The separation was performed on Inertsil ODS3 column with methanol-water (36:64) as mobile phase, with 1 mL·min -1 of flow rate at 35℃. Then the mass spectrum analysis was conducted by ZMD micromass electrospray ionization (ESI)-mass spectrometer (MS). The HPLC total ion chromatogram and selected ion chromatogram (with 325, 407, 423, 439 of m/z) of the sample and ESI-/MS mass spectra of the peaks in the chromatograms were obtained. So bilobalide, ginkgolide A, B, C and J in Ginkgo biloba L. leaves were identified. The method is easy and rapid, with a good accuracy. 展开更多
关键词 High performance liquid chromatography Electrospray ionization Mass spectrometry Ginkgo terpene lactones
下载PDF
Determination of Chlorine and Bromine in Plant Materials by Ion Chromatography 被引量:1
17
作者 胡兰 陈波 《Agricultural Science & Technology》 CAS 2016年第10期2403-2405,共3页
A method was developed for determination of chlorine and bromine in plant materials by ion chromatography using temperature programing-semi molten for sample preparation. Values of detection limits of the method found... A method was developed for determination of chlorine and bromine in plant materials by ion chromatography using temperature programing-semi molten for sample preparation. Values of detection limits of the method found were 1.0×10^-5 for CI and 1.3×10^-6 for Br. The measuring range of the method found were 0.3-20.0 mg/L for CI and 4,0-120,0 μg/L for Br. The results obtained agreed quite well with those reference values. 展开更多
关键词 Ion chromatography Temperature programing-semi molten PLANT CHLORINE BROMINE
下载PDF
Separation Properties of a New Polysiloxane-Anchored β-Cyclodextrin Derivative as Gas Chromatography Stationary Phase 被引量:1
18
作者 史雪岩 傅若农 顾峻岭 《Journal of Beijing Institute of Technology》 EI CAS 2002年第3期285-289,共5页
A new capillary gas chromatography stationary phase, monokis (2,6 di O benzyl 3 O propyl (3’)) hexakis(2,6 di O benzyl 3 O methyl) β CD bonded polysiloxane, was synthesized. It ex... A new capillary gas chromatography stationary phase, monokis (2,6 di O benzyl 3 O propyl (3’)) hexakis(2,6 di O benzyl 3 O methyl) β CD bonded polysiloxane, was synthesized. It exhibited separation abilities to disubstituted benzene isomers and some chiral solutes. It was also found that the polarity of CD derivatives can be lowered both by chemically bonding it to polysiloxane and by diluting it in polysiloxane. The separation abilities of the polysiloxane anchored CDs (SP CD) are higher than that of the unbonded CDs (S CD) and the diluted S CD at lower column temperature. Hydrosilylation reaction is one of the best methods to lower the operating temperature of CDs. 展开更多
关键词 capillary gas chromatography stationary phase polysiloxane anchored β cyclodextrin derivative di substituted benzene isomers separation enantiomers separation
下载PDF
乙酸乙酯、乳酸乙酯和己酸乙酯的两种定量方法在老白干白酒中的应用研究
19
作者 霍丽娜 《酿酒》 2025年第1期125-127,共3页
老白干香型白酒中乙酸乙酯与乳酸乙酯为主体香气,己酸乙酯含量极低,在GB/T10345-2022《白酒分析方法》的应用中,作者降低了己酸乙酯标准溶液的浓度,使标准曲线浓度范围更多覆盖样品浓度。进行了老白干原酒样品试验,对乙酸乙酯,乳酸乙酯... 老白干香型白酒中乙酸乙酯与乳酸乙酯为主体香气,己酸乙酯含量极低,在GB/T10345-2022《白酒分析方法》的应用中,作者降低了己酸乙酯标准溶液的浓度,使标准曲线浓度范围更多覆盖样品浓度。进行了老白干原酒样品试验,对乙酸乙酯,乳酸乙酯和己酸乙酯的含量运用标准曲线法和校正因子法进行分析。在实验过程中,校正因子定量法操作简单快捷,缺点是在远离单点校正点时或含量较小时,相对误差较大,方法要根据混标来确定校正因子,既要根据仪器状态及时调整校正因子,又要保证混标各成分含量的准确性。而标准曲线法是在试验所有浓度范围都有较好的准确度,缺点是乙酸乙酯、己酸乙酯、乳酸乙酯都极易挥发,称取容易有误差,标准原液配制时环境温度和操作有严格要求。在老白干酒的检测中,试验获得标准曲线定量法准确度更高。 展开更多
关键词 气相色谱 乙酸乙酯 乳酸乙酯 己酸乙酯 标准曲线法 校正因子法 准确度
下载PDF
Microcomputer Simulation of Elution Behaviour for Dicarboxylic Acids in Ion-Exclusion Chromatography
20
作者 Zhao Guo-liang ZHAO Yu-ming and Liu Li-na (Deaprtment of Chemistry Dalian University of Technology, Dalian, 116011 ) 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 1994年第2期79-84,共6页
he present paper covers a model involving Donnan memhrane equilibrium andadsorption eluilibrium to describe the retention process for diprotic organic acids inion-exclusion chromatography. On this basis the microcompu... he present paper covers a model involving Donnan memhrane equilibrium andadsorption eluilibrium to describe the retention process for diprotic organic acids inion-exclusion chromatography. On this basis the microcomputer simulation of elu-tion behaviour for dicarboxylic acids was investigated. Influences of eluent acidityand sample concentration on the retention value were studied. The theoreticallypredicted results are in reasonable agreement with the experimental data. 展开更多
关键词 ion-exclusion chromatography Elution behaviour Microcomputer simulation Dicarboxylic acids
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部