Complex dynamical phenomenon was studied in the single phase H-bridge inverter which was controlled by either a peak current or a valley current. The state functions and the discrete iterative map equations were estab...Complex dynamical phenomenon was studied in the single phase H-bridge inverter which was controlled by either a peak current or a valley current. The state functions and the discrete iterative map equations were established to analyze the dynamical phenomenon in the single phase H-bridge inverter. The dynamical characteristics of the single phase H- bridge inverter, such as time domain waveform diagram, bifurcation diagram, and folding map, were obtained by using the numerical calculation when the circuit parameters varied in specific range. Moreover, the simulation results were obtained by using the OrCAD-PSpice software to validate the numerical calculation. Both the numerical calculation and the circuit simulation show that the symmetrical dynamical phenomenon occurs in the single phase H-bridge inverter controlled by the peak current or the valley current.展开更多
The new 6-switch single-phase 5-level current-source inverter proposed in this paper was developed by properly simplifying the traditional 8-switch single-phase 5-level current-source inverter, and its operational pri...The new 6-switch single-phase 5-level current-source inverter proposed in this paper was developed by properly simplifying the traditional 8-switch single-phase 5-level current-source inverter, and its operational principle was analyzed. Just like the problem of voltage-unbalance between different levels existing in voltage-source multilevel inverters, a similar problem of current-unbalance between different levels whether for the 8-switch single-phase 5-level current-source inverter, or for the new 6-switch 5-level current-source inverter also exists. A simple current-balance control method via DC current feedback is presented here to implement the current-balance control between different levels. And to reduce the output current harmonics, PWM control technique was used. Simulation and experimental results showed that this new 6-switch topology operates correctly and that the balance-inductor can almost equally distribute the total DC current.展开更多
On the basis of analyzing and testing of common inverting circuits, a new type inverter, which has a special inverting circuit called complex isolated, has been put forward. In turn, an applicable air plasma cutting ...On the basis of analyzing and testing of common inverting circuits, a new type inverter, which has a special inverting circuit called complex isolated, has been put forward. In turn, an applicable air plasma cutting machine has also been put into use. Testing results show that this kind inverter has lots of properties as high reliability, high efficiency, good EMC(electromagnetic compatibility) and easy operating. The complex isolated inverting circuit can be considered as a quite valuable reference for the research of high power welding inverter.展开更多
A vector control based on the extended equivalent circuit and virtual circuits is proposed for the single-phase inverter.By the extended circuit,the other two phase voltages can be extended by the output voltage of th...A vector control based on the extended equivalent circuit and virtual circuits is proposed for the single-phase inverter.By the extended circuit,the other two phase voltages can be extended by the output voltage of the single-phase inverter so as to construct the voltage vector.The voltage outer-loop is to control the voltage vector in dq coordinate system,and the output voltage can track the target value without deviation in steady state.By designing the virtual circuit,the voltage inner-loop can achieve approximate decoupling and improve the dynamic response under the changeable load.Compared with the traditional dual closed-loop control,the proposed dual closed-loop control scheme only needs to detect and control the voltage without the current.It not only can achieve good control effect,but also reduce the complexity of the hardware.Finally,the simulation and experimental results show that the single-phase inverter has good static and dynamic characteristics regardless of stable load or changeable load.展开更多
Objective\ To understand the transcription of BamHI L DNA fragment from genome of strong virulent GA strain of Marek′s disease herpesvirus (MDV) in lymphoblastoid tumor tissue induced by oncogenic strain Beijing 1 ...Objective\ To understand the transcription of BamHI L DNA fragment from genome of strong virulent GA strain of Marek′s disease herpesvirus (MDV) in lymphoblastoid tumor tissue induced by oncogenic strain Beijing 1 (a specific local strain in China) of MDV. Methods\ Two oligonucleotide primers were synthesized according to the reported sequence of \%meq\% gene an ideal oncogenic candidate and our previously determined sequence of BamHI L fragment of Marek′s disease herpesvirus (MDV), respectively. Reverse transcriptase PCR(RT PCR) assay was performed by using these primers and the mRNA as a template which was isolated from visceral lymphoblastoid tumors obtained from chickens artificially infected with strain Beijing 1 of oncogenic MDV. Southern blot molecular hybridization was further carried out to detect the product of RT PCR with digoxigenin labeled nucleotide probe from BamHI I2 and L fragment in the gene library of MDV strain GA, respectively. Results\ Two probes could simultaneously hybridize this cDNA amplified by RT PCR with a length of about 730 bp. Conclusion\ It is suggested that \%meq\% transcription could extend from the right hand end of BamHI I2 to the adjacent BamHI L, and the BamHI L region was likely to be transcribed in MDV induced lymphoblastoid tumors.展开更多
Grid-connected reactive-load compensation and harmonic control are becoming a central topic as photovoltaic(PV)grid-connected systems diversified.This research aims to produce a high-performance inverter with a fast d...Grid-connected reactive-load compensation and harmonic control are becoming a central topic as photovoltaic(PV)grid-connected systems diversified.This research aims to produce a high-performance inverter with a fast dynamic response for accurate reference tracking and a low total har-monic distortion(THD)even under nonlinear load applications by improving its control scheme.The proposed system is expected to operate in both stand-alone mode and grid-connected mode.In stand-alone mode,the proposed controller supplies power to critical loads,alternatively during grid-connected mode provide excess energy to the utility.A modified variable step incremental conductance(VS-InCond)algorithm is designed to extract maximum power from PV.Whereas the proposed inverter controller is achieved by using a modified PQ theory with double-band hysteresis current controller(PQ-DBHCC)to produce a reference current based on a decomposition of a single-phase load current.The nonlinear rectifier loads often create significant distortion in the output voltage of single-phase inverters,due to excessive current harmonics in the grid.Therefore,the proposed method generates a close-loop reference current for the switching scheme,hence,minimizing the inverter voltage distortion caused by the excessive grid current harmonics.The simulation findings suggest the proposed control technique can effectively yield more than 97%of power conversion efficiency while suppressing the grid current THD by less than 2%and maintaining the unity power factor at the grid side.The efficacy of the proposed controller is simulated using MATLAB/Simulink.展开更多
A comprehensive proton-exchange membrane fuel cell stack model was developed and integrated with a two-stage DC/DC boost converter.It was directly coupled to a single-phase(two levels-four pulses)inverter without a tr...A comprehensive proton-exchange membrane fuel cell stack model was developed and integrated with a two-stage DC/DC boost converter.It was directly coupled to a single-phase(two levels-four pulses)inverter without a transformer.The pulse-width modu-lation signal was used to independently regulate every converter phase.The converter was modelled using a MATLAB®/Simulink®environment and an appropriate voltage control method.The analysis features of the suggested circuit were created and,through established experiments,the simulation results were verified.A single-phase(two levels-four pulses)inverter control circuit was tested and it produced a pure sinusoidal waveform with voltage control.It matches the voltage of the network in terms of amplitude and frequency.A sinusoidal pulse-width modulation approach was performed using a single-phase(two levels-four pulses)pulse-width modulation inverter.The results demonstrated an enhancement in the standard of the output wave and tuned the dead time with a reduction of 63μs compared with 180μs in conventional techniques.展开更多
基金Project supported by the National Natural Science Foundation of China(Grant No.51107016)the National Basic Research Program of China(Grant No.2013CB035605)the Postdoctoral Science Research Developmental Foundation of Heilongjiang Province,China(Grant No.LHB-Q12086)
文摘Complex dynamical phenomenon was studied in the single phase H-bridge inverter which was controlled by either a peak current or a valley current. The state functions and the discrete iterative map equations were established to analyze the dynamical phenomenon in the single phase H-bridge inverter. The dynamical characteristics of the single phase H- bridge inverter, such as time domain waveform diagram, bifurcation diagram, and folding map, were obtained by using the numerical calculation when the circuit parameters varied in specific range. Moreover, the simulation results were obtained by using the OrCAD-PSpice software to validate the numerical calculation. Both the numerical calculation and the circuit simulation show that the symmetrical dynamical phenomenon occurs in the single phase H-bridge inverter controlled by the peak current or the valley current.
基金Project (No. 50477033) supported by the National Natural ScienceFoundation of China
文摘The new 6-switch single-phase 5-level current-source inverter proposed in this paper was developed by properly simplifying the traditional 8-switch single-phase 5-level current-source inverter, and its operational principle was analyzed. Just like the problem of voltage-unbalance between different levels existing in voltage-source multilevel inverters, a similar problem of current-unbalance between different levels whether for the 8-switch single-phase 5-level current-source inverter, or for the new 6-switch 5-level current-source inverter also exists. A simple current-balance control method via DC current feedback is presented here to implement the current-balance control between different levels. And to reduce the output current harmonics, PWM control technique was used. Simulation and experimental results showed that this new 6-switch topology operates correctly and that the balance-inductor can almost equally distribute the total DC current.
文摘On the basis of analyzing and testing of common inverting circuits, a new type inverter, which has a special inverting circuit called complex isolated, has been put forward. In turn, an applicable air plasma cutting machine has also been put into use. Testing results show that this kind inverter has lots of properties as high reliability, high efficiency, good EMC(electromagnetic compatibility) and easy operating. The complex isolated inverting circuit can be considered as a quite valuable reference for the research of high power welding inverter.
基金This work was supported in part by the National Natural Science Foundation of China under Grant 61773006.
文摘A vector control based on the extended equivalent circuit and virtual circuits is proposed for the single-phase inverter.By the extended circuit,the other two phase voltages can be extended by the output voltage of the single-phase inverter so as to construct the voltage vector.The voltage outer-loop is to control the voltage vector in dq coordinate system,and the output voltage can track the target value without deviation in steady state.By designing the virtual circuit,the voltage inner-loop can achieve approximate decoupling and improve the dynamic response under the changeable load.Compared with the traditional dual closed-loop control,the proposed dual closed-loop control scheme only needs to detect and control the voltage without the current.It not only can achieve good control effect,but also reduce the complexity of the hardware.Finally,the simulation and experimental results show that the single-phase inverter has good static and dynamic characteristics regardless of stable load or changeable load.
文摘Objective\ To understand the transcription of BamHI L DNA fragment from genome of strong virulent GA strain of Marek′s disease herpesvirus (MDV) in lymphoblastoid tumor tissue induced by oncogenic strain Beijing 1 (a specific local strain in China) of MDV. Methods\ Two oligonucleotide primers were synthesized according to the reported sequence of \%meq\% gene an ideal oncogenic candidate and our previously determined sequence of BamHI L fragment of Marek′s disease herpesvirus (MDV), respectively. Reverse transcriptase PCR(RT PCR) assay was performed by using these primers and the mRNA as a template which was isolated from visceral lymphoblastoid tumors obtained from chickens artificially infected with strain Beijing 1 of oncogenic MDV. Southern blot molecular hybridization was further carried out to detect the product of RT PCR with digoxigenin labeled nucleotide probe from BamHI I2 and L fragment in the gene library of MDV strain GA, respectively. Results\ Two probes could simultaneously hybridize this cDNA amplified by RT PCR with a length of about 730 bp. Conclusion\ It is suggested that \%meq\% transcription could extend from the right hand end of BamHI I2 to the adjacent BamHI L, and the BamHI L region was likely to be transcribed in MDV induced lymphoblastoid tumors.
基金funded by Geran Galakan Penyelidik Muda GGPM-2020-004 Universiti Kebangsaan Malaysia.
文摘Grid-connected reactive-load compensation and harmonic control are becoming a central topic as photovoltaic(PV)grid-connected systems diversified.This research aims to produce a high-performance inverter with a fast dynamic response for accurate reference tracking and a low total har-monic distortion(THD)even under nonlinear load applications by improving its control scheme.The proposed system is expected to operate in both stand-alone mode and grid-connected mode.In stand-alone mode,the proposed controller supplies power to critical loads,alternatively during grid-connected mode provide excess energy to the utility.A modified variable step incremental conductance(VS-InCond)algorithm is designed to extract maximum power from PV.Whereas the proposed inverter controller is achieved by using a modified PQ theory with double-band hysteresis current controller(PQ-DBHCC)to produce a reference current based on a decomposition of a single-phase load current.The nonlinear rectifier loads often create significant distortion in the output voltage of single-phase inverters,due to excessive current harmonics in the grid.Therefore,the proposed method generates a close-loop reference current for the switching scheme,hence,minimizing the inverter voltage distortion caused by the excessive grid current harmonics.The simulation findings suggest the proposed control technique can effectively yield more than 97%of power conversion efficiency while suppressing the grid current THD by less than 2%and maintaining the unity power factor at the grid side.The efficacy of the proposed controller is simulated using MATLAB/Simulink.
文摘A comprehensive proton-exchange membrane fuel cell stack model was developed and integrated with a two-stage DC/DC boost converter.It was directly coupled to a single-phase(two levels-four pulses)inverter without a transformer.The pulse-width modu-lation signal was used to independently regulate every converter phase.The converter was modelled using a MATLAB®/Simulink®environment and an appropriate voltage control method.The analysis features of the suggested circuit were created and,through established experiments,the simulation results were verified.A single-phase(two levels-four pulses)inverter control circuit was tested and it produced a pure sinusoidal waveform with voltage control.It matches the voltage of the network in terms of amplitude and frequency.A sinusoidal pulse-width modulation approach was performed using a single-phase(two levels-four pulses)pulse-width modulation inverter.The results demonstrated an enhancement in the standard of the output wave and tuned the dead time with a reduction of 63μs compared with 180μs in conventional techniques.