期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Shaking Table Model Test of Isolated Structure on Soft Site and Analysis on Its Isolation Efficiency 被引量:3
1
作者 Yu Xu Zhuang Haiyang Zhu Chao 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI CSCD 2017年第2期169-176,共8页
Adopting a soft site model built on soft interlayer soil foundation,a shaking table test for soft interlayer soil-isolated structure interaction is conducted to investigate the seismic response of isolated structure o... Adopting a soft site model built on soft interlayer soil foundation,a shaking table test for soft interlayer soil-isolated structure interaction is conducted to investigate the seismic response of isolated structure on soft site,and analyze its isolation effect.Test results show that the test can reflect the earthquake response characteristics of isolated structure on soft site.It is on soft site that the dynamic characteristics of isolated structure,acceleration magnification factor(AMF)of isolated structure and isolation efficiency of the isolation layer differ from those on rigid foundation with an soil-structure interaction(SSI)effect,represented by the reduction in fundamental vibration frequency of isolated structure and the increase of damping ratio with changes of the SSI effect.SSI can either increase or decrease AMF of isolated structure on soft site,depending on the characteristics of earthquake motion input.Furthermore,the isolation efficiency of isolation layer on soft site is decreased with the SSI effect,which is related to the peak ground acceleration(PGA)and the characteristics of earthquake motion input. 展开更多
关键词 isolated structure shaking table model test soil-structure interaction(SSI) seismic response isolation efficiency
下载PDF
Prediction of vibrations induced by trains on line 8 of Beijing metro 被引量:4
2
作者 De-yun DING Shashank GUPTA +2 位作者 Wei-ning LIU Geert LOMBAERT Geert DEGRANDE 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2010年第4期280-293,共14页
This paper mainly discusses the problem of ground-borne vibrations due to the planned line 8 of Beijing metro which passes under the National Measurement Laboratory.A lot of vibration sensitive equipments are placed i... This paper mainly discusses the problem of ground-borne vibrations due to the planned line 8 of Beijing metro which passes under the National Measurement Laboratory.A lot of vibration sensitive equipments are placed in the laboratory.It is therefore necessary to study the impact of vibrations induced by metro trains on sensitive equipments and important to propound a feasible vibration mitigation measure.Based on the coupled periodic finite element-boundary element (FE-BE) method,a 3D dynamic track-tunnel-soil interaction model for metro line 8 has been used to predict vibrations in the free field induced by trains running at variable speeds between 30 km/h and 80 km/h.Four types of track structures commonly used on the Beijing metro network have been considered:(1) high resilience direct fixation fasteners,(2) Vanguard fasteners,(3) a floating slab track and (4) a floating ladder track.For each of these track types,the vibration isolation efficiency has been compared.The results of the numerical study can be used to predict vibrations in nearby buildings and to decide upon effective vibration countermeasures. 展开更多
关键词 Ground-borne vibrations Coupled periodic finite element-boundary element (FE-BE) method Track structure Vibration isolation efficiency
原文传递
Low frequency vibration tests on a floating slab track in an underground laboratory 被引量:2
3
作者 De-yun DING Wei-ning LIU +2 位作者 Ke-fei LI Xiao-jing SUN Wei-feng LIU 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2011年第5期345-359,共15页
Low frequency vibrations induced by underground railways have attracted increasing attention in recent years. To obtain the characteristics of low frequency vibrations and the low frequency performance of a floating s... Low frequency vibrations induced by underground railways have attracted increasing attention in recent years. To obtain the characteristics of low frequency vibrations and the low frequency performance of a floating slab track (FST), low frequency vibration tests on an FST in an underground laboratory at Beijing Jiaotong University were carried out. The FST and an unbalanced shaker SBZ30 for dynamic simulation were designed for use in low frequency vibration experiments. Vibration measurements were performed on the bogie of the unbalanced shaker, the rail, the slab, the tunnel invert, the tunnel wall, the tunnel apex, and on the ground surface at distances varying from 0 to 80 m from the track. Measurements were also made on several floors of an adjacent building. Detailed results of low frequency vibration tests were reported. The attenuation of low frequency vibrations with the distance from the track was presented, as well as the responses of different floors of the building. The experimental results could be regarded as a reference for developing methods to control low frequency vibrations and for adopting countermeasures. 展开更多
关键词 Low frequency vibrations Laboratory tests Floating slab track (FST) Vibration isolation efficiency
原文传递
Rapid and efficient method for isolating plant high molecular weight(HMW)DNA with high purity 被引量:4
4
作者 Fang Qiu Jianmin Fu +2 位作者 Weiwu Xie Chuanyou Li Bin Wang 《Chinese Science Bulletin》 SCIE EI CAS 1999年第4期378-380,共3页
PREPARATION of HMW DNA (Megabase-size) is the basis for construction of genomic library with large DNA inserts such as bacterial artificial chromosome (BAC) and yeast artificial chromosome (YAC), and for long-range ph... PREPARATION of HMW DNA (Megabase-size) is the basis for construction of genomic library with large DNA inserts such as bacterial artificial chromosome (BAC) and yeast artificial chromosome (YAC), and for long-range physical mapping. It can also be used for the macro-study of repeat sequences. Since HMW DNA during preparation is inclined to be sheared physically and digested by internal nucleases, it is very difficult to prepare the HMW DNA. Initially, plant HMW DNA was prepared by embedding protoplasts in the low melting-point (LMP) agarose; however, it had several disadvantages: (ⅰ) Culture of protoplasts was time-consuming, costly and tedious. ( ⅱ ) It was only used successfully for limited 展开更多
关键词 DNA Rapid and efficient method for isolating plant high molecular weight HIGH
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部