An online method using continuous flow isotope ratio mass spectrometry (CF-IRMS) interfaced with a Gasbench Ⅱ was presented to determine chlorine stable isotope composition. Silver chloride (AgCl) was quantitatively ...An online method using continuous flow isotope ratio mass spectrometry (CF-IRMS) interfaced with a Gasbench Ⅱ was presented to determine chlorine stable isotope composition. Silver chloride (AgCl) was quantitatively derived from chloride by using silver nitrate (AgNO3), and then was reacted with iodomethane (CH3I) to produce methyl chloride (CH3Cl). A GasBench Ⅱ equipped with a PoraPlot Q column was used to separate CH3Cl from any other gas species. Finally, chlorine stable isotope analysis was carried out on CH3Cl introduced to the IRMS in a helium stream via an active open split. The minimum amount of Cl used in this method is of the order of 1.4μmol. Inter-laboratory and inter-technique comparisons show that the total uncertainty incorporating both the precision and accuracy of this method is better than 0.007%. Furthermore, ten seawaters sampled from different locations have a narrow δ 37 Cl value range from -0.008% to 0.010%, with a mean value of (0.000±0.006)%. This supports the assumption that any seawater can be representative of standard mean ocean chloride (SMOC) and used as an international reference material.展开更多
A new, simple and fast separation method for Fe using an extraction chromatographic resin, Aliquat 336 (commercially available as TEVA resin) has been developed. A one milliliter column containing 0.33 mL TEVA resin o...A new, simple and fast separation method for Fe using an extraction chromatographic resin, Aliquat 336 (commercially available as TEVA resin) has been developed. A one milliliter column containing 0.33 mL TEVA resin on 0.67 mL CG-71C was used.Iron was adsorbed with 6mol·L-1 HCl + H2O2 on TEVA resin, and recovered with 2 mol·L-1HNO3. The recovery yield and total blank were 93.5 ± 6.5% and 6 ng, respectively. Theseparation method is simple, and takes < 2 hours. For evaluation of the Fe separation, Fe isotope ratios were measured by a double-spike method employing multicollector inductively coupled plasma source mass spectrometry (MC-ICP-MS) with repeatability of 0.06‰ (SD) for the standard solution and ~0.05‰ for the silicate samples. Therefore, the column chemistry developed in this study is a viable option for Fe isotope ratio measurement by MC-ICP-MS.展开更多
该文建立液相色谱-稳定同位素比值质谱联用(liquid chromatography-stable isotope ratio mass spectrometry,LC-IRMS)检测抗坏血酸δ^(13)C值的分析方法,用于鉴别针叶樱桃粉中抗坏血酸天然来源的真实性。样品中抗坏血酸经液相色谱在线...该文建立液相色谱-稳定同位素比值质谱联用(liquid chromatography-stable isotope ratio mass spectrometry,LC-IRMS)检测抗坏血酸δ^(13)C值的分析方法,用于鉴别针叶樱桃粉中抗坏血酸天然来源的真实性。样品中抗坏血酸经液相色谱在线分离纯化,优化后色谱条件为:Syncronis C18(250 mm×4.6 mm,5μm)色谱柱,流动相为水-pH 2的硫酸溶液(90∶10,体积比),流速0.250 mL/min,色谱柱温度30℃,进样量10μL,通过LC-IsoLink实现目标物全部氧化为CO_(2)气体,最终以气态形式进入稳定同位素质谱仪,直接检测样品中抗坏血酸的δ^(13)C,该方法结果稳定、准确。分别测定了7个合成来源的维生素C片和19个针叶樱桃粉,结果表明,天然来源抗坏血酸δ^(13)C值为-25.00‰~-22.01‰,合成来源抗坏血酸δ^(13)C值为-11.74‰~-10.28‰,两者分布显著性差异,该方法可用于抗坏血酸产品标识的真实性鉴别研究。展开更多
基金Projects(40772156, 41072179) supported by the National Natural Science Foundation of China
文摘An online method using continuous flow isotope ratio mass spectrometry (CF-IRMS) interfaced with a Gasbench Ⅱ was presented to determine chlorine stable isotope composition. Silver chloride (AgCl) was quantitatively derived from chloride by using silver nitrate (AgNO3), and then was reacted with iodomethane (CH3I) to produce methyl chloride (CH3Cl). A GasBench Ⅱ equipped with a PoraPlot Q column was used to separate CH3Cl from any other gas species. Finally, chlorine stable isotope analysis was carried out on CH3Cl introduced to the IRMS in a helium stream via an active open split. The minimum amount of Cl used in this method is of the order of 1.4μmol. Inter-laboratory and inter-technique comparisons show that the total uncertainty incorporating both the precision and accuracy of this method is better than 0.007%. Furthermore, ten seawaters sampled from different locations have a narrow δ 37 Cl value range from -0.008% to 0.010%, with a mean value of (0.000±0.006)%. This supports the assumption that any seawater can be representative of standard mean ocean chloride (SMOC) and used as an international reference material.
文摘A new, simple and fast separation method for Fe using an extraction chromatographic resin, Aliquat 336 (commercially available as TEVA resin) has been developed. A one milliliter column containing 0.33 mL TEVA resin on 0.67 mL CG-71C was used.Iron was adsorbed with 6mol·L-1 HCl + H2O2 on TEVA resin, and recovered with 2 mol·L-1HNO3. The recovery yield and total blank were 93.5 ± 6.5% and 6 ng, respectively. Theseparation method is simple, and takes < 2 hours. For evaluation of the Fe separation, Fe isotope ratios were measured by a double-spike method employing multicollector inductively coupled plasma source mass spectrometry (MC-ICP-MS) with repeatability of 0.06‰ (SD) for the standard solution and ~0.05‰ for the silicate samples. Therefore, the column chemistry developed in this study is a viable option for Fe isotope ratio measurement by MC-ICP-MS.