Since the room-temperature detector CdZnTe(CZT) has advantages in terms of detection efficiency,energy resolution, and size, it has been extensively used to detect X-rays and gamma-rays. So far, nuclear radiation dete...Since the room-temperature detector CdZnTe(CZT) has advantages in terms of detection efficiency,energy resolution, and size, it has been extensively used to detect X-rays and gamma-rays. So far, nuclear radiation detectors such as cerium chloride doped with lanthanum bromide(LaBr_3(Ce)), thallium doped with cesium iodide(sI(Tl)), thallium doped with sodium iodide(NaI(Tl)),and high-purity germanium(HPGe) primarily use the spectroscopy-dose rate function(G(E)) to achieve the accurate measurement of air kerma rate(K_a) and ambient dose equivalent rate(H*(10)). However, the spectroscopy-dose rate function has been rarely measured for a CZT detector. In this study, we performed spectrum measurement using a hemispherical CZT detector in a radiation protection standards laboratory. The spectroscopy-dose rate function G(E) of the CZT detector was calculated using the least-squares method combined with the standard dose rate at the measurement position. The results showed that the hemispherical CZT detector could complete the measurement of air kerma rate(K_a) and ambient dose equivalent rate(H*(10)) by using the G(E) function at energies between 48 keV and 1.25 MeV, and the relative intrinsic errors were, respectively, controlled within ± 2. 3 and ± 2. 1%.展开更多
The air-kerma is one of the most important physical quantities in ionizing radiation dosimetry. The measurement of airkerma rate in narrow-spectrum series is the basis to determine the radiation dose at protection lev...The air-kerma is one of the most important physical quantities in ionizing radiation dosimetry. The measurement of airkerma rate in narrow-spectrum series is the basis to determine the radiation dose at protection level. In this article, the absolute measurement method is used to derive the standard air-kerma rate of the ISO 4037 narrow-spectrum series that ranges from 60 kV to 150 kV by a primary standard ionization chamber,it is used in direct comparison for air kerma. The indirect method is used to obtain the air-kerma rate by a secondary standard transfer ionization chamber named A5 chamber with calibration factors of the corresponding reference qualities. The results are very similar comparing between absolute and indirect methods for air-kerma rate, all the differences are within ±3.3%.展开更多
针对《X射线探伤机》检定规程(JJG 40-2001)的要求,研制了一套X射线探伤机的检定装置。该系统主要基于空腔电离理论测量X射线辐射剂量,研制了0.6cc、600cc电离室和监测用特殊探测器(Monitor Special Detector,MSD),主要用于X射线探伤机...针对《X射线探伤机》检定规程(JJG 40-2001)的要求,研制了一套X射线探伤机的检定装置。该系统主要基于空腔电离理论测量X射线辐射剂量,研制了0.6cc、600cc电离室和监测用特殊探测器(Monitor Special Detector,MSD),主要用于X射线探伤机空气比释动能率、辐射角、重复性等参数的检定。展开更多
基金supported by the National Key Scientific Instruments to Develop Dedicated(Nos.2013YQ090811 and 2016YFF0103800)
文摘Since the room-temperature detector CdZnTe(CZT) has advantages in terms of detection efficiency,energy resolution, and size, it has been extensively used to detect X-rays and gamma-rays. So far, nuclear radiation detectors such as cerium chloride doped with lanthanum bromide(LaBr_3(Ce)), thallium doped with cesium iodide(sI(Tl)), thallium doped with sodium iodide(NaI(Tl)),and high-purity germanium(HPGe) primarily use the spectroscopy-dose rate function(G(E)) to achieve the accurate measurement of air kerma rate(K_a) and ambient dose equivalent rate(H*(10)). However, the spectroscopy-dose rate function has been rarely measured for a CZT detector. In this study, we performed spectrum measurement using a hemispherical CZT detector in a radiation protection standards laboratory. The spectroscopy-dose rate function G(E) of the CZT detector was calculated using the least-squares method combined with the standard dose rate at the measurement position. The results showed that the hemispherical CZT detector could complete the measurement of air kerma rate(K_a) and ambient dose equivalent rate(H*(10)) by using the G(E) function at energies between 48 keV and 1.25 MeV, and the relative intrinsic errors were, respectively, controlled within ± 2. 3 and ± 2. 1%.
文摘The air-kerma is one of the most important physical quantities in ionizing radiation dosimetry. The measurement of airkerma rate in narrow-spectrum series is the basis to determine the radiation dose at protection level. In this article, the absolute measurement method is used to derive the standard air-kerma rate of the ISO 4037 narrow-spectrum series that ranges from 60 kV to 150 kV by a primary standard ionization chamber,it is used in direct comparison for air kerma. The indirect method is used to obtain the air-kerma rate by a secondary standard transfer ionization chamber named A5 chamber with calibration factors of the corresponding reference qualities. The results are very similar comparing between absolute and indirect methods for air-kerma rate, all the differences are within ±3.3%.
文摘针对《X射线探伤机》检定规程(JJG 40-2001)的要求,研制了一套X射线探伤机的检定装置。该系统主要基于空腔电离理论测量X射线辐射剂量,研制了0.6cc、600cc电离室和监测用特殊探测器(Monitor Special Detector,MSD),主要用于X射线探伤机空气比释动能率、辐射角、重复性等参数的检定。