The thermal environmental characteristics are experim-entally studied in terms of different air supply volumes and outdoor meteorological parameters in a large-space building which is air conditioned with a low sidewa...The thermal environmental characteristics are experim-entally studied in terms of different air supply volumes and outdoor meteorological parameters in a large-space building which is air conditioned with a low sidewall air supply.The experimental results show that the indoor vertical temperature distributions under different condition are similar.The maximum vertical temperature difference(MVTD)is up to about 20 ℃,and it linearly changes with the sol-air temperature.The indoor vertical temperature gradients(VTGs)in the upper,central and lower zones are different.The influence of the sol-air temperature on the VTGs in the upper and the lower zones is greater than that in the central zone.The characteristics of the VTGs in the three zones affected by the air supply volume are the same as those affected by the sol-air temperature.Besides,because of the small air velocity,the predicted mean vote(PMV)on comfort in the occupied zone is slightly high and the air temperature difference between the head and the ankle is usually more than 3 ℃.展开更多
The importance and necessity of energy saving in the world have been discussed for many years,but achieving a logical and transparent solution is still one of the main challenges and problems of the world’s eco...The importance and necessity of energy saving in the world have been discussed for many years,but achieving a logical and transparent solution is still one of the main challenges and problems of the world’s economy.The rapid growth of energy consumption in the last two decades has caused the security of the domestic energy supply of buildings to face serious problems.In this research,first by entering parameters such as the type of materials,doors and windows,and the type of soil on the floor connected to the ground,etc.in the heat and cold load calculation software(HAP Carrier)as the design calculations and then in the second step entering the specifications inferred from the Iran’s national building code as a reference for energy saving calculations,calculations are performed and compared as the first criterion,and finally these two outputs are compared.The actual energy consumption and determination of the building energy consumption index are determined as another criterion,as well as the degree of deviation from the actual consumption.The results showed that the theoretical method and the thermal and refrigeration load calculations of the Zanjan Gas Company building have 6%difference in cooling load but the heating load is about 34%different,which means for cooling loads,the theoretical model can be used with high accuracy but for heating loads,the national building code needs fundamental changes.展开更多
Based on the structural characteristics of existing buildings and the disadvantages of current mixed ventilation mode in the application to large space buildings,an original column attachment ventilation(CAV)has been ...Based on the structural characteristics of existing buildings and the disadvantages of current mixed ventilation mode in the application to large space buildings,an original column attachment ventilation(CAV)has been proposed.In this study,the experiment utilized a room space with four columns uniformly distributed in the space to visualize the movement of attached airflow along the cylinder surface and the floor,the numerical technique was employed to study the effects of the column layout(i.e.,uniform,centralized,dispersed,and crossed distribution)on the air distribution of CAV mode in a standard four-column full scale model of a shopping mall.Seven indices,including airflow pattern,air diffusion performance index(ADPI),air temperature distribution,heat removal effectiveness,draught rate(DR),predicted mean vote(PMV),and carbon dioxide(CO2)concentration,were used to assess the ventilation performance.In the CAV mode with a uniform column layout scheme,the experimental results indicated that the air supply flows downward along the wall surface,forming a secondary attachment with the ground and spreading along the floor in a fan radiation flow mode.Further,an“air lake”-like speed and temperature distribution similar to displacement ventilation(DV)was formed in the occupied zone.In all simulation cases,it was found that the average air velocity was less than 0.25 m/s in occupied zone,the effectiveness for heat removal was more significant than 1.0,DR value was less than 20%,the PMV level can also satisfy most people.The average CO2 concentration was around 470 ppm in the occupied breathing zone.These results indicated that the CAV mode could be an efficient air distribution method.They demonstrated the technical feasibility of applying the CAV in the space under different column layout schemes.展开更多
With the development of information technology, the fire safety assessment of whole structure or region based on the computer simulation has become a hot topic. However, traditionally, the concerned studies are perfor...With the development of information technology, the fire safety assessment of whole structure or region based on the computer simulation has become a hot topic. However, traditionally, the concerned studies are performed separately for different objectives and difficult to perform an overall evaluation. A new multi-dimensional integration model and methodology for fire safety assessment were presented and two newly developed integrated systems were introduced to demonstrate the function of integration simulation technology in this paper. The first one is the analysis on the fire-resistant behaviors of whole structure under real fire loads. The second one is the study on fire evaluation and emergency rescue of campus based on geography information technology (GIS). Some practical examples are presented to illuminate the advantages of computer integration technology on fire safety assessment and emphasize some problems in the simulation. The results show that the multi-dimensional integration model offers a new way and platform for the integrating fire safety assessment of whole structure or region, and the integrated software developed is the useful engineering tools for cost-saving and safe design.展开更多
基金The National Natural Science Foundation of China(No.50478113)the Leading Academic Discipline Project of Shanghai Municipal Education Commission(No.J50502)
文摘The thermal environmental characteristics are experim-entally studied in terms of different air supply volumes and outdoor meteorological parameters in a large-space building which is air conditioned with a low sidewall air supply.The experimental results show that the indoor vertical temperature distributions under different condition are similar.The maximum vertical temperature difference(MVTD)is up to about 20 ℃,and it linearly changes with the sol-air temperature.The indoor vertical temperature gradients(VTGs)in the upper,central and lower zones are different.The influence of the sol-air temperature on the VTGs in the upper and the lower zones is greater than that in the central zone.The characteristics of the VTGs in the three zones affected by the air supply volume are the same as those affected by the sol-air temperature.Besides,because of the small air velocity,the predicted mean vote(PMV)on comfort in the occupied zone is slightly high and the air temperature difference between the head and the ankle is usually more than 3 ℃.
文摘The importance and necessity of energy saving in the world have been discussed for many years,but achieving a logical and transparent solution is still one of the main challenges and problems of the world’s economy.The rapid growth of energy consumption in the last two decades has caused the security of the domestic energy supply of buildings to face serious problems.In this research,first by entering parameters such as the type of materials,doors and windows,and the type of soil on the floor connected to the ground,etc.in the heat and cold load calculation software(HAP Carrier)as the design calculations and then in the second step entering the specifications inferred from the Iran’s national building code as a reference for energy saving calculations,calculations are performed and compared as the first criterion,and finally these two outputs are compared.The actual energy consumption and determination of the building energy consumption index are determined as another criterion,as well as the degree of deviation from the actual consumption.The results showed that the theoretical method and the thermal and refrigeration load calculations of the Zanjan Gas Company building have 6%difference in cooling load but the heating load is about 34%different,which means for cooling loads,the theoretical model can be used with high accuracy but for heating loads,the national building code needs fundamental changes.
基金This study was jointly funded by the National Natural Science Foundation of China(No.51408477)the Innovative Talent Promotion Plan of Shaanxi Province(No.2018KJXX-087)and the Youth Talent Support Project of Xi’an Association for Science and Technology.
文摘Based on the structural characteristics of existing buildings and the disadvantages of current mixed ventilation mode in the application to large space buildings,an original column attachment ventilation(CAV)has been proposed.In this study,the experiment utilized a room space with four columns uniformly distributed in the space to visualize the movement of attached airflow along the cylinder surface and the floor,the numerical technique was employed to study the effects of the column layout(i.e.,uniform,centralized,dispersed,and crossed distribution)on the air distribution of CAV mode in a standard four-column full scale model of a shopping mall.Seven indices,including airflow pattern,air diffusion performance index(ADPI),air temperature distribution,heat removal effectiveness,draught rate(DR),predicted mean vote(PMV),and carbon dioxide(CO2)concentration,were used to assess the ventilation performance.In the CAV mode with a uniform column layout scheme,the experimental results indicated that the air supply flows downward along the wall surface,forming a secondary attachment with the ground and spreading along the floor in a fan radiation flow mode.Further,an“air lake”-like speed and temperature distribution similar to displacement ventilation(DV)was formed in the occupied zone.In all simulation cases,it was found that the average air velocity was less than 0.25 m/s in occupied zone,the effectiveness for heat removal was more significant than 1.0,DR value was less than 20%,the PMV level can also satisfy most people.The average CO2 concentration was around 470 ppm in the occupied breathing zone.These results indicated that the CAV mode could be an efficient air distribution method.They demonstrated the technical feasibility of applying the CAV in the space under different column layout schemes.
基金the National Natural Science Foundation of China (No. 50348028)
文摘With the development of information technology, the fire safety assessment of whole structure or region based on the computer simulation has become a hot topic. However, traditionally, the concerned studies are performed separately for different objectives and difficult to perform an overall evaluation. A new multi-dimensional integration model and methodology for fire safety assessment were presented and two newly developed integrated systems were introduced to demonstrate the function of integration simulation technology in this paper. The first one is the analysis on the fire-resistant behaviors of whole structure under real fire loads. The second one is the study on fire evaluation and emergency rescue of campus based on geography information technology (GIS). Some practical examples are presented to illuminate the advantages of computer integration technology on fire safety assessment and emphasize some problems in the simulation. The results show that the multi-dimensional integration model offers a new way and platform for the integrating fire safety assessment of whole structure or region, and the integrated software developed is the useful engineering tools for cost-saving and safe design.