期刊文献+
共找到3,233篇文章
< 1 2 162 >
每页显示 20 50 100
Seismic response of a mid-story isolated structure considering SSI in mountainous areas under long-period earthquakes
1
作者 Wan Feng Qin Shengwu +7 位作者 Liu Dewen Zhao Tiange Zheng Yanping Shan Hang Li Zhiang Peng Fusong Xu Jingran Lei Min 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2024年第1期151-161,共11页
At present,there is not much research on mid-story isolated structures in mountainous areas.In this study,a model of a mid-story isolated structure considering soil-structure interaction(SSI)in mountainous areas is es... At present,there is not much research on mid-story isolated structures in mountainous areas.In this study,a model of a mid-story isolated structure considering soil-structure interaction(SSI)in mountainous areas is established along with a model that does not consider SSI.Eight long-period earthquake waves and two ordinary earthquake waves are selected as inputs for the dynamic time history analysis of the structure.The results show that the seismic response of a mid-story isolated structure considering SSI in mountainous areas can be amplified when compared with a structure that does not consider SSI.The structure response under long-period earthquakes is larger than that of ordinary earthquakes.The structure response under far-field harmonic-like earthquakes is larger than that of near-fault pulse-type earthquakes.The structure response under near-fault pulse-type earthquakes is larger than that of far-field non-harmonic earthquakes.When subjected to long-period earthquakes,the displacement of the isolated bearings exceeded the limit value,which led to instability and overturning of the structure.The structure with dampers in the isolated story could adequately control the nonlinear response of the structure,effectively reduce the displacement of the isolated bearings,and provide a convenient,efficient and economic method not only for new construction but also to retrofit existing structures. 展开更多
关键词 SSI in mountainous areas long-period earthquakes mid-story isolated structure structural dynamic analysis
下载PDF
Seismic Response of Adjacent Structure to Inter-Story Isolated Structure
2
作者 Bingxing Ma Dewen Liu +3 位作者 Zhuoxin Yang Jiayu Zhou Yong Ding Tao Ban 《World Journal of Engineering and Technology》 2024年第1期92-102,共11页
Currently, land resources are becoming more and more constrained and structures are getting closer to each other. To investigate the seismic response of inter-story isolated structure to adjacent structure, models con... Currently, land resources are becoming more and more constrained and structures are getting closer to each other. To investigate the seismic response of inter-story isolated structure to adjacent structure, models considering no soil-structure interaction (SSI), considering soil-structure interaction (SSI), and considering structure-soil-structure interaction (SSSI) were established. Nonlinear seismic response comparative analysis was conducted by varying the spacing between adjacent structure and inter-story isolated structure, as well as the weight of adjacent structure, under different earthquake inputs, in order to obtain the structural response characteristics. The results indicate that the inter-story drift and inter-story shear of the inter-story isolated structure without considering SSI are smaller than those considering SSI and SSSI. The inter-story drift and inter-story shear of the inter-story isolated structure considering SSSI are further affected compared to that of the inter-story isolated structure considering only SSI. As the spacing between adjacent structure and inter-story isolated structure increases, the influence of adjacent structure on inter-story isolated structure decreases. The variation in the spacing between the two structures has a negligible effect on the isolation layer of the inter-story isolated structure. With the increase in the weight of adjacent structure, the influence of adjacent structure on inter-story isolated structure becomes more significant. The increasing weight of adjacent structure has an increasing effect on the Isolation layer of the inter-story isolated structure. 展开更多
关键词 Soil-structure Interaction (SSI) structure-Soil-structure Interaction (SSSI) In-ter-Story isolation Adjacent structure
下载PDF
Seismic Response Analysis of Steel Structure Isolation System Under Long-Period Seismic Motion
3
作者 Long Yu Mei Sheng +1 位作者 Huan Feng Jianan Hu 《Journal of Architectural Research and Development》 2024年第3期147-155,共9页
To analyze the seismic response of steel structure isolation systems under long-period seismic motion,a 9-story steel frame building was selected as the subject.Five steel structure finite element models were establis... To analyze the seismic response of steel structure isolation systems under long-period seismic motion,a 9-story steel frame building was selected as the subject.Five steel structure finite element models were established using SAP2000.Response spectrum analysis was conducted on the seismic motion to determine if it adhered to the characteristics of long-period seismic motion.Modal analysis of each structural model revealed that the isolation structure significantly prolonged the structural natural vibration period and enhanced seismic performance.Base reactions and floor displacements of various structures notably increased under long-period seismic motion compared to regular seismic activity.Placing isolation bearings in the lower part of the structure proved more effective under long-period seismic motion.In seismic design engineering,it is essential to consider the impact of long-period seismic motion on structures and the potential failure of isolation bearings. 展开更多
关键词 Long-period seismic motion Steel structure Mid-story isolation structure isolation bearing Seismic performance
下载PDF
Influence of Vertical Irregularity on the Seismic Behavior of Base Isolated RC Structures with Lead Rubber Bearings under Pulse-Like Earthquakes
4
作者 Ali Mahamied Amjad AYasin +2 位作者 Yazan Alzubi Jamal Al Adwan Issa Mahamied 《Structural Durability & Health Monitoring》 EI 2023年第6期501-519,共19页
Nowadays,an extensive number of studies related to the performance of base isolation systems implemented in regular reinforced concrete structures subjected to various types of earthquakes can be found in the literatu... Nowadays,an extensive number of studies related to the performance of base isolation systems implemented in regular reinforced concrete structures subjected to various types of earthquakes can be found in the literature.On the other hand,investigations regarding the irregular base-isolated reinforced concrete structures’performance when subjected to pulse-like earthquakes are very scarce.The severity of pulse-like earthquakes emerges from their ability to destabilize the base-isolated structure by remarkably increasing the displacement demands.Thus,this study is intended to investigate the effects of pulse-like earthquake characteristics on the behavior of low-rise irregular base-isolated reinforced concrete structures.Within the study scope,investigations related to the impact of the pulse-like earthquake characteristics,irregularity type,and isolator properties will be conducted.To do so,different values of damping ratios of the base isolation system were selected to investigate the efficiency of the lead rubber-bearing isolator.In general,the outcomes of the study have shown the significance of vertical irregularity on the performance of base-isolated structures and the considerable effect of pulse-like ground motions on the buildings’behavior. 展开更多
关键词 Reinforced concrete low-rise structure vertical irregularity the influence of pulse-like earthquake characteristics lead rubber bearing isolators nonlinear response history analysis
下载PDF
A bio-inspired spider-like structure isolator for low-frequency vibration 被引量:1
5
作者 Guangdong SUI Shuai HOU +5 位作者 Xiaofan ZHANG Xiaobiao SHAN Chengwei HOU Henan SONG Weijie HOU Jianming LI 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI CSCD 2023年第8期1263-1286,共24页
This paper proposes a quasi-zero stiffness(QZS)isolator composed of a curved beam(as spider foot)and a linear spring(as spider muscle)inspired by the precise capturing ability of spiders in vibrating environments.The ... This paper proposes a quasi-zero stiffness(QZS)isolator composed of a curved beam(as spider foot)and a linear spring(as spider muscle)inspired by the precise capturing ability of spiders in vibrating environments.The curved beam is simplified as an inclined horizontal spring,and a static analysis is carried out to explore the effects of different structural parameters on the stiffness performance of the QZS isolator.The finite element simulation analysis verifies that the QZS isolator can significantly reduce the first-order natural frequency under the load in the QZS region.The harmonic balance method(HBM)is used to explore the effects of the excitation amplitude,damping ratio,and stiffness coefficient on the system’s amplitude-frequency response and transmissibility performance,and the accuracy of the analytical results is verified by the fourth-order Runge-Kutta integral method(RK-4).The experimental data of the QZS isolator prototype are fitted to a ninth-degree polynomial,and the RK-4 can theoretically predict the experimental results.The experimental results show that the QZS isolator has a lower initial isolation frequency and a wider isolation frequency bandwidth than the equivalent linear isolator.The frequency sweep test of prototypes with different harmonic excitation amplitudes shows that the initial isolation frequency of the QZS isolator is 3 Hz,and it can isolate 90%of the excitation signal at 7 Hz.The proposed biomimetic spider-like QZS isolator has high application prospects and can provide a reference for optimizing low-frequency or ultra-low-frequency isolators. 展开更多
关键词 bionic isolation structure curved beam nonlinear stiffness quasi-zero stiffness(QzS) low-frequency vibration isolator
下载PDF
High-Throughput Growth of Hexagonal Boron Nitride Film Using Porous-Structure Isolation Layer
6
作者 Ruitao Jia Fangzhu Qing Xuesong Li 《Journal of Materials Science and Chemical Engineering》 CAS 2023年第3期45-51,共7页
Chemical vapor deposition is considered as the most hopeful method for the synthesis of large-area high-quality hexagonal boron nitride on the substrate of catalytic metal. However, the size the hexagonal boron nitrid... Chemical vapor deposition is considered as the most hopeful method for the synthesis of large-area high-quality hexagonal boron nitride on the substrate of catalytic metal. However, the size the hexagonal boron nitride films are limited to the size of growth chamber, which indicates a lower production efficiency. In this paper, the utilization efficiency of growth chamber is highly improved by alternately stacking multiple pieces of Cu foils and carbon fiber surface felt with porous structure. Uniform and continuous hexagonal boron nitride films are prepared on Cu foils through chemical vapor deposition utilizing ammonia borane as the precursor. This work develops a simple and practicable method for high-throughput preparation of hexagonal boron nitride films, which could contribute to the industrial application of hexagonal boron nitride. . 展开更多
关键词 Hexagonal Boron Nitride Chemical Vapor Deposition Porous structure isolation Layer High Throughput
下载PDF
Shaking Table Model Test of Isolated Structure on Soft Site and Analysis on Its Isolation Efficiency 被引量:3
7
作者 Yu Xu Zhuang Haiyang Zhu Chao 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI CSCD 2017年第2期169-176,共8页
Adopting a soft site model built on soft interlayer soil foundation,a shaking table test for soft interlayer soil-isolated structure interaction is conducted to investigate the seismic response of isolated structure o... Adopting a soft site model built on soft interlayer soil foundation,a shaking table test for soft interlayer soil-isolated structure interaction is conducted to investigate the seismic response of isolated structure on soft site,and analyze its isolation effect.Test results show that the test can reflect the earthquake response characteristics of isolated structure on soft site.It is on soft site that the dynamic characteristics of isolated structure,acceleration magnification factor(AMF)of isolated structure and isolation efficiency of the isolation layer differ from those on rigid foundation with an soil-structure interaction(SSI)effect,represented by the reduction in fundamental vibration frequency of isolated structure and the increase of damping ratio with changes of the SSI effect.SSI can either increase or decrease AMF of isolated structure on soft site,depending on the characteristics of earthquake motion input.Furthermore,the isolation efficiency of isolation layer on soft site is decreased with the SSI effect,which is related to the peak ground acceleration(PGA)and the characteristics of earthquake motion input. 展开更多
关键词 isolated structure shaking table model test soil-structure interaction(SSI) seismic response isolation efficiency
下载PDF
Purification and Primary Structure Determination of a Novel Polypeptide Isolated from Mistletoe Viscum coloratum 被引量:2
8
作者 JingLinKONG XiuBaoDU ChongXuFAN YingCAO HuiJIANG JianFuXU XiaoJunZHENG 《Chinese Chemical Letters》 SCIE CAS CSCD 2004年第11期1311-1314,共4页
A novel polypeptide was isolated from mistletoe Viscum coloratum. The primary structure of the polypeptide named viscotoxin B2 was determined to be KSCCKNTTGRNIYNT CRFAGGSRERCAKLSGCKIISASTCPSDYPK by Edman degradation.... A novel polypeptide was isolated from mistletoe Viscum coloratum. The primary structure of the polypeptide named viscotoxin B2 was determined to be KSCCKNTTGRNIYNT CRFAGGSRERCAKLSGCKIISASTCPSDYPK by Edman degradation. Viscotoxin B2 shared high sequence homology with viscotoxins isolated from Viscum album. Pharmacological experiments showed that viscotoxin B2 had distinct cytotoxic activity on tumor cells. Viscotoxin B2 could be used as a leading compound in cancer therapy. 展开更多
关键词 Viscum coloratum isolATION primary structure viscotoxin.
下载PDF
Synthesis,Structure and Fluorescent Property of a New Isolated Zn6Co9 Heteronuclear Cluster Constructed by Four Kinds of Ligands 被引量:3
9
作者 张光辉 卢久富 《Chinese Journal of Structural Chemistry》 SCIE CAS CSCD 2016年第11期1666-1672,共7页
A novel zero-dimensional heteronuclear cluster based on N-(phosphonomethyl)imi- no-diacetic acid (H4PMIDA) and Phen (1,10-phenanthroline), [Zn6Co9(PMIDA)6(Phen)6(NO3)4(H2O)6]·2NO3·16H2O, has be... A novel zero-dimensional heteronuclear cluster based on N-(phosphonomethyl)imi- no-diacetic acid (H4PMIDA) and Phen (1,10-phenanthroline), [Zn6Co9(PMIDA)6(Phen)6(NO3)4(H2O)6]·2NO3·16H2O, has been synthesized under hydrothermal conditions and characterized by elemental analysis, IR spectrum, thermal analysis, and single-crystal X-ray diffraction. The isolated 15- nuclearity cluster [Zn6Co9(PMIDA)6(Phen)6(NO3)4(H2O)6]^2+ was constructed by four kinds of ligands, and its charges are balanced by NO3^–. Each isolated cluster is further extended into a 3D supramolecular network through π???π interaction and C–H…O hydrogen bonds. Moreover, the solid-state fluorescent property of this complex has also been investigated at room temperature. 展开更多
关键词 isolated heteronuclear cluster mixed ligands crystal structure fluorescent property
下载PDF
Optimal design and effectiveness evaluation for inerter-based devices on mitigating seismic responses of base isolated structures 被引量:3
10
作者 Li Yafeng Li Shouying Chen Zhengqing 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2021年第4期1021-1032,共12页
The optimal design and effectiveness of three control systems,tuned viscous mass damper(TVMD),tuned inerter damper(TID)and tuned mass damper(TMD),on mitigating the seismic responses of base isolated structures,were sy... The optimal design and effectiveness of three control systems,tuned viscous mass damper(TVMD),tuned inerter damper(TID)and tuned mass damper(TMD),on mitigating the seismic responses of base isolated structures,were systematically studied.First,the seismic responses of the base isolated structure with each control system under white noise excitation were obtained.Then,the structural parameter optimizations of the TVMD,TID and TMD were conducted by using three different objectives.The results show that the three control systems were all effective in minimizing the root mean square value of seismic responses,including the base shear of the BIS,the absolute acceleration of structural SDOF,and the relative displacement between the base isolation floor and the foundation.Finally,considering the superstructure as a structural MDOF,a series of time history analyses were performed to investigate the effectiveness and activation sensitivity of the three control systems under far field and near fault seismic excitations.The results show that the effectiveness of TID and TMD with optimized parameters on mitigating the seismic responses of base isolated structures increased as the mass ratio increases,and the effectiveness of TID was always better than TMD with the same mass ratio.The TVMD with a lower mass ratio was more efficient in reducing the seismic response than the TID and TMD.Furthermore,the TVMD,when compared with TMD and TID,had better activation sensitivity and a smaller stroke. 展开更多
关键词 base isolated structure inerter optimal design seismic response vibration control
下载PDF
Dynamic Analysis for Structures Isolated with Dampers 被引量:1
11
作者 Gu Peiying and Gao Ming M. Sc, Engineer, Material and Structure Department, Nanjing Hydraulic Research Institute, Nanjing 210024 Professor, Material and Structure Department, Nanjing Hydraulic Research Institute, Nanjing 210024 《China Ocean Engineering》 SCIE EI 1996年第3期269-280,共12页
In this paper, mathematical models and dynamic analyses for both SDOF and MDOF structures isolated with dampers are established and performed, and a comprehensive computation method is provided. The shock absorbing ef... In this paper, mathematical models and dynamic analyses for both SDOF and MDOF structures isolated with dampers are established and performed, and a comprehensive computation method is provided. The shock absorbing effect is illustrated through an example of a two DOF damper-isolated system excited by sinusoidal waves and actual ground acceleration input recorded in earthquakes. It is shown that most of the responses of the structure with dampers reduce greatly near the resonant zone, but acceleration is enlarged in the lower or higher frequency zone; among various parameters, the influence of frictional coefficient n is the most significant, that of damping ratio of the dampers , is the second, and that of stiffness coefficient of the dampers k, is the slightest. 展开更多
关键词 shock absorbing structure isolated with dampers shock absorbing effect dynamic analysis parametric analysis
下载PDF
INFLUENCE OF DAMPING MODELS ON DYNAMIC ANALYSES OF A BASE-ISOLATED COMPOSITE STRUCTURE UNDER EARTHQUAKES AND ENVIRONMENTAL VIBRATIONS 被引量:1
12
作者 费一凡 田源 +1 位作者 黄羽立 陆新征 《工程力学》 EI CSCD 北大核心 2022年第3期201-211,共11页
Structural design simultaneously governed by earthquakes and environmental vibrations has received a lot of attention in recent years.Base-isolated composite structures are typically used in the above-mentioned struct... Structural design simultaneously governed by earthquakes and environmental vibrations has received a lot of attention in recent years.Base-isolated composite structures are typically used in the above-mentioned structural design.The corresponding analysis involves validating structural safety under earthquakes and human comfort under environmental vibrations through a time-history analysis.Thus,a reasonable damping model is essential.In this work,the representatives of viscous damping model and rate-independent damping model,namely the Rayleigh damping model and uniform damping model,were adopted to investigate the influence of damping models on the time-history analysis of such structural designs.The energy dissipation characteristics of the above-mentioned damping models were illustrated via a dynamic test of recycled aggregate concrete specimens.A case study was performed on a base-isolated steelconcrete composite structure.The dynamic responses under the excitation of earthquakes and environmental vibrations were compared using different damping models.The uniform damping model was found to be more flexible than the Rayleigh damping model in dealing with excitations with different frequency components.The uniform damping model is both theoretically advantageous and easy to use,demonstrating its potential in dynamic analysis of structures designed simultaneously governed by earthquakes and environmental vibrations. 展开更多
关键词 seismic and environmental vibration analysis Rayleigh damping model uniform damping model seismic isolation composite structure
下载PDF
A modified Kelvin impact model for pounding simulation of base-isolated building with adjacent structures 被引量:13
13
作者 Ye Kun Li Li Zhu Hongping 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2009年第3期433-446,共14页
Base isolation can effectively reduce the seismic forces on a superstructure, particularly in lowto medium-rise buildings. However, under strong near-fault ground motions, pounding may occur at the isolation level bet... Base isolation can effectively reduce the seismic forces on a superstructure, particularly in lowto medium-rise buildings. However, under strong near-fault ground motions, pounding may occur at the isolation level between the baseisolated building (BIB) and its surrounding retaining walls. To effectively investigate the behavior of the BIB pounding with adjacent structures, after assessing some commonly used impact models, a modified Kelvin impact model is proposed in this paper. Relevant parameters in the modified Kelvin model are theoretically derived and numerically verified through a simple pounding case. At the same time, inelasticity of the isolated superstructure is introduced in order to accurately evaluate the potential damage to the superstructure caused by the pounding of the BIB with adjacent structures. The reliability of the modified Kelvin impact model is validated through numerical comparisons with other impact models. However, the difference between the numerical results from the various impact analytical models is not significant. Many numerical simulations of BIBs are conducted to investigate the influence of various design parameters and conditions on the peak inter-story drifts and floor accelerations during pounding. It is shown that pounding can substantially increase floor accelerations, especially at the ground floor where impacts occur. Higher modes of vibration are excited during poundings, increasing the inter-story drifts instead of keeping a nearly rigid-body motion of the superstructure. Furthermore, higher ductility demands can be imposed on lower floors of the superstructure. Moreover, impact stiffness seems to play a significant role in the acceleration response at the isolation level and the inter-story drifts of lower floors of the superstructure. Finally, the numerical results show that excessive flexibility of the isolation system used to minimize the floor accelerations may cause the BIB to be more susceptible to pounding under a limited seismic gap. 展开更多
关键词 structural pounding BASE-isolATION near-fault ground motions Kelvin impact model nonlinear damping
下载PDF
The height-width ratio limited value for rubber bearing isolated structure computed by uniform design method 被引量:7
14
作者 王铁英 王焕定 +1 位作者 张永山 刘文光 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2007年第1期36-40,共5页
Rubber isolation is the most mature control technology in practical application, and is widely used by short rigid buildings. However, many high isolation buildings have been built around the world in recent years, wh... Rubber isolation is the most mature control technology in practical application, and is widely used by short rigid buildings. However, many high isolation buildings have been built around the world in recent years, which do not follow the existing criterions and codes. Many researchers began to research the special problems caused by larger height-width ratio isolation structures. The overturning effect of high height-width ratio structures with rubber bearing is firstly studied. Considering the main factors, such as the height-width ratio of structures, type of site, the designed basic acceleration of ground motion and the decouple factor in horizon, computing experiment is defined with the Uniform Design Method, which is also known as designing isolation structure. The forces of the bearing under edge of structures based on the position of the rubber bearing are calculated. The result indicates that the rubber bearings will lose its functionality under very high tension and compressing force of earthquake motion in horizon and vertical, when the height-width ratio is over a certain value. Thus, based on the calculation result of isolation structures defined in the uniform design method, regression analysis is conducted, and also the rubber edge force regression formula are gotten, which has higher correlation and smaller standard deviation. This formula can be used to roughly calculate whether the pull force occurs at the edge of the building. By the edge bearings of isolation structure minimum force formula, the height-width ratio limited value of the isolation structure is deducted when rubber bearing has minimum force of zero. 展开更多
关键词 隔离结构 建筑结构 工程设计 非线性动力分析
下载PDF
Roles of soil-structure interaction and damping in base-isolated structures built on numerous soil layers overlying a half-space 被引量:1
15
作者 C.S.Tsai C.I.Hsueh H.C.Su 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2016年第2期387-400,共14页
This study examines the roles of soil-structure interaction (SSI), higher modes, and damping in a base-isolated structure built on multiple layers of soil overlying a half space. Closed-form solutions for the entire... This study examines the roles of soil-structure interaction (SSI), higher modes, and damping in a base-isolated structure built on multiple layers of soil overlying a half space. Closed-form solutions for the entire system, including a superstructure, seismic isolator, and numerous soil layers overlying a half-space, were obtained. The formulations obtained in this study simply in terms of well-known frequencies and mechanical impedance ratios can explicitly interpret the dynamic behavior of a base-isolated structure interacting with multiple soil layers overlying a half-space. The key factors influencing the performance of the isolation system are the damping ratio of the isolator and the ratio of the natural frequency of the fixed-base structure to that of the isolated structure by assuming that the superstructure moves as a rigid body. This study reveals that higher damping in the base isolator is unfavorable to higher mode responses that usually dominate the responses of the superstructure and that the damping mechanism plays an important role in transmitting energy in addition to absorbing energy. It is also concluded that it is possible to design a soft soil layer as an isolation system for isolating vibration energy. 展开更多
关键词 base isolation seismic isolation soil-structure interaction closed- form solution higher-mode effects soilstratum passive control damping effects
下载PDF
Simple Method for Dynamic Responses of Soil-Pile-Isolated Structure Interaction System 被引量:1
16
作者 Yu Xu Zhuang Haiyang Liu Shuai 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI CSCD 2017年第4期426-437,共12页
To investigate the effect of soil-pile-structure interaction(SPSI effect)on the dynamic response of a baseisolated structure with buried footings on a pile foundation,certain shake table tests are previously conducted... To investigate the effect of soil-pile-structure interaction(SPSI effect)on the dynamic response of a baseisolated structure with buried footings on a pile foundation,certain shake table tests are previously conducted.Based on the test results and the existing related studies,an efficient simplified model and a corresponding calculation method are verified for estimating the dynamic characteristics of a base-isolated structure with buried footings on a pile foundation with the SSI effect.In this method,the solutions by Veletsos and co-workers for a non-isolated structure with the SSI effect are verified and advanced for a base-isolated structure,and the solutions by Maravas and co-workers for a non-isolated structure on a pile foundation are introduced to consider the effect of the piles.By comparison with the shake table test,this work proves that the simplified method can efficiently estimate the dynamic responses of a base-isolated structure with buried footings on a pile foundation.Using parameter analysis,this work also shows that the dynamic characteristics of a non-isolated structure are quite similar to those of the base-isolated structure when the soil foundation is sufficiently soft,which means that the isolation layer gradually loses its isolation function as the soil foundation softens. 展开更多
关键词 soil-structure interaction(SSI) base-isolated structure seismic response shake table test simplified method
下载PDF
STRUCTURE OF NERVOSIN D ISOLATED FROM ISODOM NERVOSUS
17
作者 Mei Juan XU Xin En HUANG Pei Yuan CHENG Jin XIANG Mai TANG a Nanjing Institute of Materia Medica,Nanjing 210009 b Jiangsu Institute of Cancer Research,Nanjing 210009 c Sanitary School of Fujian Province,Fujian 350000 《Chinese Chemical Letters》 SCIE CAS CSCD 1993年第9期783-784,共2页
On the basis of spectral analysis combined with preparation of derivatives,nervosin D was identified as ent-12,6β,7β,112,15β-pentahydro- xy-72,20-epoxykaur-16-ene.
关键词 PPM structure OF NERVOSIN D isolated FROM ISODOM NERVOSUS
下载PDF
Modelling and Analysis of Base Isolated Structures with Friction Pendulum System Considering near Fault Events
18
作者 Luigi Petti Fabrizio Polichetti +1 位作者 Alessio Lodato Bruno Palazzo 《Open Journal of Civil Engineering》 2013年第2期86-93,共8页
The seismic behavior of base isolated structures with friction pendulum slide bearings devices subjected to near fault events characterized by significant vertical ground motion components is investigated. In particul... The seismic behavior of base isolated structures with friction pendulum slide bearings devices subjected to near fault events characterized by significant vertical ground motion components is investigated. In particular, in order to evaluate the effects of vertical components on seismic response, non-linear dynamic analysis, carried out by using several numerical models, have been performed by considering two near-fault seismic events, L’Aquila 2009 and Emilia Romagna 2012. The obtained results show that increasing vertical seismic motion base shear significantly increases while relative displacements increase very little. 展开更多
关键词 Base isolated structures FRICTION PENDULUM SLIDE Bearings Spatial SEISMIC DEMAND
下载PDF
Seismic response reduction analysis of large chassis base-isolated structure under long-period ground motions
19
作者 Feiyan Li Linjian Wang Yingxiong Wu 《Earthquake Research Advances》 CSCD 2021年第2期49-56,共8页
Long-period structures(e.g.Isolated structures)tend to produce pseudo-resonance with low frequency compo-nents of long-period ground motions,resulting in the increase in damage.Stiffness mutation occurs due to the set... Long-period structures(e.g.Isolated structures)tend to produce pseudo-resonance with low frequency compo-nents of long-period ground motions,resulting in the increase in damage.Stiffness mutation occurs due to the set-back in the upper body of the large chassis structure.In the parts with stiffness mutation,the torsion effect caused by the tower is far greater than that of the chassis itself.In this study,a total of 273 ground motions are collected and then filtered into four types,including the near-field ordinary,near-field pulse,far-field ordinary,and far-field harmonic.An 8-degree(0.2 g)fortified large chassis base-isolated structure is established.Furthermore,ETABS program software is used to conduct nonlinear time history analysis on the isolation and seismic model under bi-directional earthquake ground motions.The comparison results show that the seismic isolation effect of the base-isolated structure under long-period ground motions is worse than that associated with ordinary ground motions when the seismic response reduction rate of the large base floor significantly decreases compared with that of the tower.When the inter-story displacement angle and the displacement of isolation layer of the chassis exceeds the limit of Code for Seismic Design of Buildings(GB 50011-2010),it is recommended to adopt composite seismic isolation technology or add limit devices.Under the condition of long-period ground motions,the base-isolated structure reduces the lateral-torsional coupling effect of the large chassis structure,while the torsion response of large chassis’top layer increases.Under long-period ground motions with the same acceleration peak,the response of the base-isolated structure increases much more than that of the seismic structure and the consideration of this impact is suggested to be added to the Code. 展开更多
关键词 Long-period ground motions Large chassis structure Base isolation Seismic response reduction analysis
下载PDF
Seismic Responses of Asymmetric Base-Isolated Structures under Near-Fault Ground Motion 被引量:1
20
作者 叶昆 李黎 方秦汉 《Journal of Southwest Jiaotong University(English Edition)》 2008年第4期335-345,共11页
An inter-story shear model of asymmetric base-isolated structures incorporating deformation of each isolation bearing was built, and a method to simultaneously simulate bi-directional near-fault and far-field ground m... An inter-story shear model of asymmetric base-isolated structures incorporating deformation of each isolation bearing was built, and a method to simultaneously simulate bi-directional near-fault and far-field ground motions was proposed. A comparative study on the dynamic responses of asymmetric base-isolated structures under near-fault and far-field ground motions were conducted to investigate the effects of eccentricity in the isolation system and in the superstructures, the ratio of the uncoupled torsional to lateral frequency of the superstructure and the pulse period of near-fault ground motions on the nonlinear seismic response of asymmetric base-isolated structures. Numerical results show that eccentricity in the isolation system makes asymmetric base-isolated structure more sensitive to near-fault ground motions, and the pulse period of near-fault ground motions plays an import role in governing the seismic responses of asymmetric base-isolated structures. 展开更多
关键词 Asymmetric base-isolated structure Near-fault ground motion Far-field ground motion Nonlinear seismic response
下载PDF
上一页 1 2 162 下一页 到第
使用帮助 返回顶部