期刊文献+
共找到4,700篇文章
< 1 2 235 >
每页显示 20 50 100
Assessment of Wet Season Precipitation in the Central United States by the Regional Climate Simulation of the WRFG Member in NARCCAP and Its Relationship with Large-Scale Circulation Biases 被引量:1
1
作者 Yating ZHAO Ming XUE +2 位作者 Jing JIANG Xiao-Ming HU Anning HUANG 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 2024年第4期619-638,共20页
Assessment of past-climate simulations of regional climate models(RCMs)is important for understanding the reliability of RCMs when used to project future regional climate.Here,we assess the performance and discuss pos... Assessment of past-climate simulations of regional climate models(RCMs)is important for understanding the reliability of RCMs when used to project future regional climate.Here,we assess the performance and discuss possible causes of biases in a WRF-based RCM with a grid spacing of 50 km,named WRFG,from the North American Regional Climate Change Assessment Program(NARCCAP)in simulating wet season precipitation over the Central United States for a period when observational data are available.The RCM reproduces key features of the precipitation distribution characteristics during late spring to early summer,although it tends to underestimate the magnitude of precipitation.This dry bias is partially due to the model’s lack of skill in simulating nocturnal precipitation related to the lack of eastward propagating convective systems in the simulation.Inaccuracy in reproducing large-scale circulation and environmental conditions is another contributing factor.The too weak simulated pressure gradient between the Rocky Mountains and the Gulf of Mexico results in weaker southerly winds in between,leading to a reduction of warm moist air transport from the Gulf to the Central Great Plains.The simulated low-level horizontal convergence fields are less favorable for upward motion than in the NARR and hence,for the development of moist convection as well.Therefore,a careful examination of an RCM’s deficiencies and the identification of the source of errors are important when using the RCM to project precipitation changes in future climate scenarios. 展开更多
关键词 NARCCAP Central united States PRECIPITATION low-level jet large-scale environment diurnal variation
下载PDF
Difference between grid connections of large-scale wind power and conventional synchronous generation 被引量:7
2
作者 Jie Li Chao Liu +2 位作者 Pengfei Zhang Yafeng Wang Jun Rong 《Global Energy Interconnection》 2020年第5期486-493,共8页
In China, regions with abundant wind energy resources are generally located at the end of power grids. The power grid architecture in these regions is typically not sufficiently strong, and the energy structure is rel... In China, regions with abundant wind energy resources are generally located at the end of power grids. The power grid architecture in these regions is typically not sufficiently strong, and the energy structure is relatively simple. Thus, connecting large-capacity wind power units complicates the peak load regulation and stable operation of the power grids in these regions. Most wind turbines use power electronic converter technology, which affects the safety and stability of the power grid differently compared with conventional synchronous generators. Furthermore, fluctuations in wind power cause fluctuations in the output of wind farms, making it difficult to create and implement suitable power generation plans for wind farms. The generation technology and grid connection scheme for wind power and conventional thermal power generation differ considerably. Moreover, the active and reactive power control abilities of wind turbines are weaker than those of thermal power units, necessitating additional equipment to control wind turbines. Hence, to address the aforementioned issues with large-scale wind power generation, this study analyzes the differences between the grid connection and collection strategies for wind power bases and thermal power plants. Based on this analysis, the differences in the power control modes of wind power and thermal power are further investigated. Finally, the stability of different control modes is analyzed through simulation. The findings can be beneficial for the planning and development of large-scale wind power generation farms. 展开更多
关键词 large-scale wind power generation Conventional synchronous generators Grid connection scheme Power control
下载PDF
Using Hybrid Penalty and Gated Linear Units to Improve Wasserstein Generative Adversarial Networks for Single-Channel Speech Enhancement
3
作者 Xiaojun Zhu Heming Huang 《Computer Modeling in Engineering & Sciences》 SCIE EI 2023年第6期2155-2172,共18页
Recently,speech enhancement methods based on Generative Adversarial Networks have achieved good performance in time-domain noisy signals.However,the training of Generative Adversarial Networks has such problems as con... Recently,speech enhancement methods based on Generative Adversarial Networks have achieved good performance in time-domain noisy signals.However,the training of Generative Adversarial Networks has such problems as convergence difficulty,model collapse,etc.In this work,an end-to-end speech enhancement model based on Wasserstein Generative Adversarial Networks is proposed,and some improvements have been made in order to get faster convergence speed and better generated speech quality.Specifically,in the generator coding part,each convolution layer adopts different convolution kernel sizes to conduct convolution operations for obtaining speech coding information from multiple scales;a gated linear unit is introduced to alleviate the vanishing gradient problem with the increase of network depth;the gradient penalty of the discriminator is replaced with spectral normalization to accelerate the convergence rate of themodel;a hybrid penalty termcomposed of L1 regularization and a scale-invariant signal-to-distortion ratio is introduced into the loss function of the generator to improve the quality of generated speech.The experimental results on both TIMIT corpus and Tibetan corpus show that the proposed model improves the speech quality significantly and accelerates the convergence speed of the model. 展开更多
关键词 Speech enhancement generative adversarial networks hybrid penalty gated linear units multi-scale convolution
下载PDF
Designing a Protection Scheme in Micro-Grid Systems with DG Using Central Protection Unite and Multiple Setting Group Protection Relays
4
作者 Mostafa I. Saleh Gaber El-Saady +1 位作者 Ali M. Yousef El-Noby A. Ibrahim 《Journal of Power and Energy Engineering》 2024年第9期37-49,共13页
Distributed generators now is widely used in electrical power networks, in some cases it works seasonally, and some types works at special weather conditions like photo voltaic systems and wind energy, and due to this... Distributed generators now is widely used in electrical power networks, in some cases it works seasonally, and some types works at special weather conditions like photo voltaic systems and wind energy, and due to this continuous changes in generation condition, the fault current level in network will be affected, this changes in fault current level will affect in the coordination between protection relays and to keep the coordination at right way, an adaptive protection system is required that can adaptive its setting according to generation changes, the fault current level in each case is evaluated using ETAP software, and the required relay setting in each case is also evaluated using Grey Wolf Optimizer (GWO) algorithm, and to select suitable setting which required in each condition, to select the active setting group of protection relay according to generation capacity, central protection unite can be used, and to improve protection stability and minimizing relays tripping time, a proposed method for selecting suitable backup relay is used, which leads to decrease relays tripping time and increase system stability, output settings for relays in all cases achieved our constrains. 展开更多
关键词 Directional Overcurrent Relay Protection Coordination Distributed generators Central Protection unite Multiple Setting Group Protection Relay
下载PDF
ZIZ-2 Vibration monitoring and diagnosing system for turbine generator units
5
《Electricity》 1996年第1期53-53,共1页
ZJZ-2 system has the following functions: (1) Real-time on-line sampling and FFT analysis (32 channel); (2) Data aquisition, analysis and storage during start-up and shut-down; (3) Alarming, emergency recognition and ... ZJZ-2 system has the following functions: (1) Real-time on-line sampling and FFT analysis (32 channel); (2) Data aquisition, analysis and storage during start-up and shut-down; (3) Alarming, emergency recognition and fault retrieval; (4) Data aquisition, analysis and storage during daily operation; (5) Recall of historic data; (6) Output of routine reports and tables; (7) Analysis of vibration behaviour: Bode plot, polar plot, spectrum, cascade, waveform, shaft orbit, trend, etc; 展开更多
关键词 LINE ZIZ-2 Vibration monitoring and diagnosing system for turbine generator units
下载PDF
Improved Units of Measure in Rotational Mechanics
6
作者 Richard James Petti 《World Journal of Mechanics》 2024年第1期1-7,共7页
The SI system of units in rotational mechanics yields correct numerical results, but it produces physically incorrect units of measure in many cases. SI units also violate the principle of general covariance—the gene... The SI system of units in rotational mechanics yields correct numerical results, but it produces physically incorrect units of measure in many cases. SI units also violate the principle of general covariance—the general rule for defining continuous coordinates and units in mathematics and mathematical physics. After 30+ years of wrestling with these problems, the ultimate authority on units of measure has declared that Newton–meter and Joule are not equivalent in rotational mechanics, as they are in the rest of physics. This article proposes a simple modification to SI units called “Nonstandard International units” (“NI units”) until a better name is agreed upon. NI units yield correct numerical results and physically correct units of measure, and they satisfy the principle of general covariance. The main obstacle to the adoption of NI units is the consensus among users that the radius of rotation should have the unit meter because the radius can be measured with a ruler. NI units assigned to radius should have units meter/radian because the radius is a conversion factor between angular size and circumferential length, as in arclength = rθ. To manage the social consensus behind SI units, the author recommends retaining SI units as they are, and informing users who want correct units that NI units solve the technical problems of SI units. 展开更多
关键词 Rotational Mechanics Angular unit TORQUE Moment of Inertia Angular Momentum general Covariance
下载PDF
Transitional Revenue Scheme for High-cost Generator Unit in Guangdong Electricity Market Based on Government Authorized Contracts 被引量:1
7
作者 Jisong Zhu Baike Chen +1 位作者 Tianyao Ji Zhaoxia Jing 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2024年第1期208-221,共14页
High-cost generator units are at a cost disadvantage in electricity spot markets.This study focuses on revenue mechanisms of gas-fired units affected by power market reform in Guangdong province,China.For the first ti... High-cost generator units are at a cost disadvantage in electricity spot markets.This study focuses on revenue mechanisms of gas-fired units affected by power market reform in Guangdong province,China.For the first time,we compare impacts on market indicators of five settlement mechanisms:feed-in tariff(FiT),location marginal price(LMP),contract for difference(CFD),direct subsidy(DS),and estimated revenue method(ERM).In particular,we design key parameters,including authorized CFD and ERM of two kinds of government authorized contracts based on traditional dispatching patterns to avoid significant profit fluctuations brought by market reforms.We also analyze impact of factors such as climbing performance,seasonal load,and subsidy amount on the overall market and its players.Results of a case study show to directly subsidize gasfired units will lead higher-cost units to generate more electricity,with a resulting loss of social welfare.Disruption of market prices and provision of unreasonable incentives are fatal disadvantages of this subsidy method.The government and policymakers should consider financial means to adjust benefits to reduce production costs and increase social welfare.Also,by case analysis,the ERM shows its stable performance in revenue of high-cost units,while we find that authorized CFD is not applicable for gas-fired units whose output is unstable as a marginal unit frequently.Therefore,we suggest government agencies adopt ERM to sign contracts with gas-fired units,to attain a balance between fairness and efficiency. 展开更多
关键词 Guangdong electricity market high-cost generator unit settlement mechanism SUBSIDY
原文传递
Analysis on the Problems in Start-up and Debugging of Two 600 MW Generating Units in Yangzhou No.2 Thermal Power Plant
8
作者 蒯狄正 《Electricity》 2001年第2期11-15,共5页
The problems including excessive flow of attemperating water for boiler, failure of butterfly valve at the outlet of circulating water pump, burnt-out of thyristor for excitation regulator, load variation rate of CCS ... The problems including excessive flow of attemperating water for boiler, failure of butterfly valve at the outlet of circulating water pump, burnt-out of thyristor for excitation regulator, load variation rate of CCS not complying with the contract target, etc. occurred during start-up and debugging of two 600 MW generating units in Yangzhou No.2 Thermal Power Plant. Through analysis on these problems. the remedial measures were put forward, to which can be referred for similar units. 展开更多
关键词 start-up and debugging problems analysis remedial measures 600 MW generating unit
下载PDF
Coordinated control strategy for a PV-storage grid-connected system based on a virtual synchronous generator 被引量:4
9
作者 Xing Zhang Qian Gao +3 位作者 Zixuan Guo Haizheng Zhang Ming Li Fei Li 《Global Energy Interconnection》 2020年第1期52-60,共9页
Due to the characteristics of intermittent photovoltaic power generation and power fluctuations in distributed photovoltaic power generation,photovoltaic grid-connected systems are usually equipped with energy storage... Due to the characteristics of intermittent photovoltaic power generation and power fluctuations in distributed photovoltaic power generation,photovoltaic grid-connected systems are usually equipped with energy storage units.Most of the structures combined with energy storage are used as the DC side.At the same time,virtual synchronous generators have been widely used in distributed power generation due to their inertial damping and frequency and voltage regulation.For the PV-storage grid-connected system based on virtual synchronous generators,the existing control strategy has unclear function allocation,fluctuations in photovoltaic inverter output power,and high requirements for coordinated control of PV arrays,energy storage units,and photovoltaic inverters,which make the control strategy more complicated.In order to solve the above problems,a control strategy for PV-storage grid-connected system based on a virtual synchronous generator is proposed.In this strategy,the energy storage unit implements maximum power point tracking,and the photovoltaic inverter implements a virtual synchronous generator algorithm,so that the functions implemented by each part of the system are clear,which reduces the requirements for coordinated control.At the same time,the smooth power command is used to suppress the fluctuation of the output power of the photovoltaic inverter.The simulation validates the effectiveness of the proposed method from three aspects:grid-connected operating conditions,frequency-modulated operating conditions,and illumination sudden-drop operating condition.Compared with the existing control strategies,the proposed method simplifies the control strategies and stabilizes the photovoltaic inverter fluctuation in the output power of the inverter. 展开更多
关键词 Photovoltaic power generation Energy STORAGE unit Virtual SYNCHRONOUS generator SMOOTH FLUCTUATION COORDINATED control
下载PDF
Study on Generation Cost Prediction Based on Coal Quality and Generating Unit Performance 被引量:6
10
作者 ZHONG Wei LIU Chenggang ZHOU Yonggang WU Yanling ZHOU Yi LI Pei 《中国电机工程学报》 EI CSCD 北大核心 2013年第11期I0004-I0004,6,共1页
燃料变化条件下发电成本的预测是火电厂普遍关心的重要课题。分析了影响机组性能及发电电量成本的各种煤质指标,重点研究了基于结构参数及燃烧传热机理的锅炉稳态热力性能分析计算方法,讨论了制粉系统、风机、脱硫和脱硝装置性能随燃... 燃料变化条件下发电成本的预测是火电厂普遍关心的重要课题。分析了影响机组性能及发电电量成本的各种煤质指标,重点研究了基于结构参数及燃烧传热机理的锅炉稳态热力性能分析计算方法,讨论了制粉系统、风机、脱硫和脱硝装置性能随燃料等运行条件的变化关系,最终提出了基于煤质和机组性能分析计算的发电电量成本预测模型并研发了“煤炭选配与机组发电成本预测系统”。该系统在我国某600MW火电厂的实际应用经验表明:提出的电量成本分析预测模型合理,研发的软件系统有助于辅助火电厂的选煤和购煤决策,优化动力配煤方案,从而提高火电厂的运行经济性。 展开更多
关键词 成本预测 发电成本 机组性能 市场化改革 煤质 火电厂 电力 燃料
下载PDF
Construction Schedule of Generating Units Actually Realized in 1996 (as of Aug. 8,1996) 被引量:2
11
《Electricity》 1996年第4期53-53,共1页
关键词 as of Aug Construction Schedule of generating units Actually Realized in 1996
下载PDF
An Analysis of the Designed Performance and Structural Characteristics of the Turbine Generating Units of TGP 被引量:1
12
作者 Huang Yuanfang (China Yangtze Three Gorges Project Development Corporation, Yichang, Hubei\ 443002) 《工程科学(英文版)》 2003年第1期47-52,共6页
The main technical requirement of the turbine generating units for the Three Gorges Project (TGP) has a basic conclusion through a long term study and research as well as demonstration.Along with the TGP construction ... The main technical requirement of the turbine generating units for the Three Gorges Project (TGP) has a basic conclusion through a long term study and research as well as demonstration.Along with the TGP construction and successful execution of the contract of turbine generating units,the technical difficulties concerning the performance and structure of turbine generating units have been further recognized.In this paper some issues are discussed and analyzed in connection with a deep going cognition of turbine generating units for TGP during the period of design, manufacture and installation. 展开更多
关键词 Three Gorges Project TURBINE generATING unitS TECHNICAL problems DISCUSSION and ANALYSIS
下载PDF
Acute Generalized Peritonitis in Intensive Care Unit at University Hospital of Brazzaville, Republic of Congo: Etiological, Therapeutic Aspects and Issues
13
作者 Christ Mayick Mpoy Emy Monkessa Peggy Dahlia Gallou Leyono-Mawandza +4 位作者 Marie Elombila Gilles Niengo Outsouta Marina Aurole Bokoba-Nde Ngala Giresse Bienvenu Tsouassa Wa Ngono Gilbert Fabrice Otiobanda 《Open Journal of Emergency Medicine》 2020年第4期86-94,共9页
<b><span style="font-family:Verdana;">Aim: </span></b><span style="font-family:""><span style="font-family:Verdana;">To determine etiological, the... <b><span style="font-family:Verdana;">Aim: </span></b><span style="font-family:""><span style="font-family:Verdana;">To determine etiological, therapeutic aspects and issues of AGP in intensive care unit (ICU) at University Hospital of Brazzaville (UHB). </span><b><span style="font-family:Verdana;">Materials and Methods: </span></b><span style="font-family:Verdana;">It was a retrospective and descriptive study carried out from January to December 2016 in ICU at UHB. We collected completed medical records of patients admitted and operated for AGP regardless of age or sex. The parameters studied were age, sex, admission’s reasons, etiologies, management, post-operative complications, length of hospital and mortality. Data were treated in Excel 2010 and Epi info 2007. </span><b><span style="font-family:Verdana;">Results: </span></b><span style="font-family:Verdana;">Thirty-one complete medical records were identified (mean age: 40.6 ± 22.0 years). The sex ratio was 2.4. Shock was the most common reason for admission with 67.7% of the cases. The etiologies of AGP w</span></span><span style="font-family:Verdana;">ere</span><span style="font-family:Verdana;"> dominated by gastroduodenal perforating ulcer (41.9%) followed </span><span style="font-family:Verdana;">by </span><span style="font-family:""><span style="font-family:Verdana;">complicated appendicitis (19.4%). The management of all patients was medico-surgical. The bi antibiotic ceftriaxone-metronidazole was administered in 29 patients (93.6%). 18 patients (59.1%) received vasopressor therapy. The complications had occurred among 9 patients </span><i><span style="font-family:Verdana;">i.e.</span></i><span style="font-family:Verdana;"> 29% of the cases;parietal suppurations represented 44.5% of the complications. The average length of hospitalization was 5.2 ± 4.6 days. The overall mortality was 41.9%. </span><b><span style="font-family:Verdana;">Conclusion: </span></b><span style="font-family:Verdana;">In our study, the most frequent etiologies were gastroduodenal perforating ulcer and complicated appendicitis. They affected young patients. The complications were dominated by parietal suppurations. The mortality rate was high. 展开更多
关键词 Acute generalized Peritonitis BRAZZAVILLE ETIOLOGIES Intensive Care unit ISSUES
下载PDF
The design and practice of giant hydro turbine generating units of Three Gorges Project
14
作者 Shao Jianxiong Liu Jingwang Yuan Dafu 《Engineering Sciences》 EI 2011年第3期88-95,共8页
The main technical problems that should be considered in the design of hydro-turbine generating units of Three Gorges Project (TGP) are analyzed;the key technical researches performed are summarized,and the parameters... The main technical problems that should be considered in the design of hydro-turbine generating units of Three Gorges Project (TGP) are analyzed;the key technical researches performed are summarized,and the parameters of hydro-turbine generating units are optimized through the study on key technical problems.The unit operation indicates that the performance of the hydro-turbine generating units is excellent,and the units can operate in a safe,stable and highly efficient mode for a long term.Therefore,it is verified effectively that the general technical design of units is scientific and rational. 展开更多
关键词 Three Gorges Project (TGP) 700 MW hydro-turbine generating unit unit capacity design and research operation stability practice
下载PDF
Optimal Generator Portfolio in Day-Ahead Market under Uncertain Carbon Tax Policy
15
作者 Shengyuan Chen Ming Zhao 《American Journal of Operations Research》 2011年第4期268-276,共9页
The global liberalization of energy market and the evolving carbon policy have profound implication on a producer’s optimal generator portfolio problem. On one hand, the daily operational flexibility from a well- com... The global liberalization of energy market and the evolving carbon policy have profound implication on a producer’s optimal generator portfolio problem. On one hand, the daily operational flexibility from a well- composed generator portfolio enables the producer to implement a more aggressive bidding strategy in the liberalized day-ahead market on a daily basis;on the other hand, the evolving carbon policy demands the long term robustness of a generator portfolio: it should be able to generate stable cash flow under different stages of the evolving carbon tax policy. It is computationally very challenging to incorporate the daily bidding strategy into such a long term generator portfolio study. We overcome the difficulty by a powerful vertical decomposition. The long term uncertainty of carbon tax policy is simulated by scenarios;while the daily electricity price fluctuation with jumps is modeled by a more complicated Markov Regime Switching model. The proposed model provides the senior executives an efficient quantitative tool to select an optimal generator portfolio in the deregulated market under evolving carbon tax policy. 展开更多
关键词 Carbon TAX generator PORTFOLIO MARKOV REGIME Switching Model Stochastic Programming unit COMMITMENT Simulation
下载PDF
α-Input and α-Unit Resolution Methods for Generalized Horn Clause Set in L_(V(n×2))F(X) 被引量:1
16
作者 何星星 徐扬 +1 位作者 李莹芳 刘军 《Journal of Donghua University(English Edition)》 EI CAS 2012年第1期66-70,共5页
a-Input resolution and a-unit resolution for generalized Horn clause set are discussed in linguistic truth-valued lattice-valued first-order logic ( Lv( n × 2) F(X) ), which can represent and handle uncerta... a-Input resolution and a-unit resolution for generalized Horn clause set are discussed in linguistic truth-valued lattice-valued first-order logic ( Lv( n × 2) F(X) ), which can represent and handle uncertain linguistic values-based information. Firstly the concepts of a-input resolution and a.unit resolution are presented, and the equivalence of them is shown. Then α-input (a-unit) resolution is equivalently transformed from Lv( n × 2) F(X) into that of LnP(X), and their soundness and completeness are also established. Finally an algorithm for a-unit resolution is contrived in LnP( X). 展开更多
关键词 linguistic truth-valued lattice-valued logic a-input resolution α-unit resolution generalized Horn clause set
下载PDF
Analysis on Operation Reliability of Generating Units in 2009
17
作者 Zhou Hong Power Reliability Management Center Li Shixue 《Electricity》 2010年第3期26-31,共6页
This paper presents the data on operation reliability indices and relevant analyses toward China's conventional power generating units in 2009.The units brought into the statistical analysis include 100-MW or abov... This paper presents the data on operation reliability indices and relevant analyses toward China's conventional power generating units in 2009.The units brought into the statistical analysis include 100-MW or above thermal generating units,40-MW or above hydro generating units,and all nuclear generating units.The reliability indices embodied include utilization hours,times and hours of scheduled outages,times and hours of unscheduled outages,equivalent forced outage rate and equivalent availability factor. 展开更多
关键词 power plant generating unit operation reliability statistical data
下载PDF
Construction Schedule of Generating Units to be Commissioned in 1998 (as of Dec 11, 1998)
18
《Electricity》 1999年第2期50-50,共1页
关键词 as of Dec 11 Construction Schedule of generating units to be Commissioned in 1998
下载PDF
8 large coal-fired generating units planned to be commissioned in Shandong Power Grid in 1997
19
《Electricity》 1997年第2期51-52,共2页
关键词 GRID large coal-fired generating units planned to be commissioned in Shandong Power Grid in 1997
下载PDF
An Analysis of Zhabei Cas Turbine Project and the Development of Cas Turbine Generating Unit
20
《Electricity》 1997年第4期21-23,共3页
关键词 PROJECT An Analysis of Zhabei Cas Turbine Project and the Development of Cas Turbine generating unit
下载PDF
上一页 1 2 235 下一页 到第
使用帮助 返回顶部