期刊文献+
共找到290篇文章
< 1 2 15 >
每页显示 20 50 100
Dislocation,fold and striae of comeal flap with laser assisted in situ keratomileusis after ocular trauma:a case report
1
作者 Liu Xin Zhong Ming Zhao Chunyan 《Journal of Medical Colleges of PLA(China)》 CAS 2008年第1期52-54,共3页
Objective: To report the occurrence, management and outcome ot late-onset traumauc aemscence ana dislocation of laser assisted in situ keratomileusis (LASIK) flaps. Treatment and Results: One patient occurred late... Objective: To report the occurrence, management and outcome ot late-onset traumauc aemscence ana dislocation of laser assisted in situ keratomileusis (LASIK) flaps. Treatment and Results: One patient occurred late-onset LASIK corneal flap dislocation after ocular trauma 7days after surgery. The flap was lifted, stretched, and repositioned after irrigation and scraping of the stromal bed and the underside of the flap. A bandage contact lens was placed, and topical antibiotic and corticosteroids were given postoperatively. The dislocated corneal flap was successfully repositioned in the case. The dislocated flap was repositioned 7 days after the trauma, and the patient recovered his uncorrected visual acuity (UCVA) of 10/20, 20/20 day 1 and day 20 after the procedure, of 20/20 20 days later and had a well-positioned flap with a clear interface. Diffuse lamellar keratitis developed in the patients that resolved with the use of topical corticosteroids. Conclusion: Laser in situ keratomileusis corneal flaps are vulnerable to traumatic dehiscence and dislocation, which should be pay more attention to it for us. 展开更多
关键词 laser assisted in situ keratomileusis (LASIK) Ocular trauma Corneal flap DISLOCATION Treatment
下载PDF
Evaluation of laser in situ keratomileusis for myopic correction performed under thin flaps
2
作者 Asaad A Ghanem Ehab H Nematallah 《World Journal of Ophthalmology》 2011年第1期11-16,共6页
AIM: To evaluate the efficacy and safety of laser-assisted subepithelial keratectomy (LASIK) for myopic correction done under thin flaps(120μm) and compare with results obtained under thick flaps(150μm).METH... AIM: To evaluate the efficacy and safety of laser-assisted subepithelial keratectomy (LASIK) for myopic correction done under thin flaps(120μm) and compare with results obtained under thick flaps(150μm).METHODS: The study included 150 myopic eyes of 75 patients without previous refractive surgery who underwent LASIK prospectively. Two microkeratome heads (90 and 130) were used to created a flap with thickness of 120μm and 150μm,respectively. Thin flap group(120μm) included 75 eyes while thick flap group included 75 eyes. Follow-up period was 12 mo. Efficacy,l safety, and stability were evaluated and compared between the two groups.RESULTS: In 150 eyes,the mean preoperative spherical equivalent refraction was -8.65±2.6D,mean sphere was -4.4±3.5D, and mean cylinder was -1.0±1.3D. THe amount of ablation was significantly larger in the thin flap (88.5±32.21μm) group than in the thick flap group (64±28.13μm).Percentage of safety was higher in the thin flap group(94.8%) than in the thick flap group(91.7%). There were no intraoperative complications, especially flap-related problems. Subjective symptoms of dry eye occurred in 20.7% and 33.3% of eyes in the thin and thick flap groups, respectively. CONCLUSION: Thin-flap LASIK is effective and safe in correcting myopic defects. It achivevs better visual results, rapid visual recovery, and stable postoperative refraction than LASIK with thick flaps. 展开更多
关键词 laser in situ keratomileusis MYOPIA Thin flap THick flap
下载PDF
Above-average defocus curves in photopic and mesopic vision with multifocal intraocular lenses after laser assisted in situ keratomileusis
3
作者 Joaquín Fernández Manuel Rodríguez-Vallejo +2 位作者 Javier Martínez Ana Tauste David P Pi?ero 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第10期1620-1623,共4页
I am Dr. David P Pifiero from the Department of Optics, Pharmacology and Anatomy of the University of Alicante and from the Department of Ophthalmology of Vithas Medimar (Oftalmar) and Vithas Virgen del Carmen (Qv... I am Dr. David P Pifiero from the Department of Optics, Pharmacology and Anatomy of the University of Alicante and from the Department of Ophthalmology of Vithas Medimar (Oftalmar) and Vithas Virgen del Carmen (Qvision) hospitals in Spain. 展开更多
关键词 Figure LASIK Above-average defocus curves in photopic and mesopic vision with multifocal intraocular lenses after laser assisted in situ keratomileusis IOL
下载PDF
Corneal flap morphological analysis using anterior segment optical coherence tomography in laser in situ keratomileusis with femtosecond lasers versus mechanical microkeratome 被引量:9
4
作者 Xiao-Xiao Zhang Xing-Wu Zhong +4 位作者 Jun-Shu Wu Zheng Wang Ke-Ming Yu Quan Liu and Bin Yang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2012年第1期69-73,共5页
AIM: To assess and compare the flap morphology using anterior segment optical coherence tomography (AS-OCT) in laser in situ keratomileusis (LASIK) with Femto LDV femtosecond lasers versus Hansatome mechanical Microke... AIM: To assess and compare the flap morphology using anterior segment optical coherence tomography (AS-OCT) in laser in situ keratomileusis (LASIK) with Femto LDV femtosecond lasers versus Hansatome mechanical Microkeratome. METHODS: AS-OCT (Visante) was used to compare 1 month postoperatively the morphology of the flaps created with Femto LDV femtosecond lasers or Hansatome Microkeratome. The intendedfiap thickness was 110 mu m and 160 mu m respectively. The thickness of twenty-five points across each flap, which were 0mm, 1.5mm, 2.5mm, and 3.5mm to the corneal vertex on the horizontal, vertical, 45 degrees and 135 degrees meridian respectively, was evaluated. RESULTS: One month postoperative, the central flap thickness in the Femto LDV group was 107.43 +/- 4.70 mu m, while 125.90 +/- 17.50 mu m in the Hansatome group. The difference between the actual and the expectedfiap thickness was 5.61 +/- 3.84 mu m and 31.52 +/- 12.27 mu m, respectively. The Hansatome group had presented a statistically significant result (P<0.001). Flap morphology showed a more regular planar shape in the Femto LDV group and a meniscus shape in the Hansatome group. CONCLUSION: AS-OCT is a direct and fast procedure to assess the flap morphology. The morphology by AS-OCT showed that the flaps created with Femto LDV femtosecond laser were more accurate and regular than the flaps created with Hansatome microkeratome. 展开更多
关键词 AS-OCT laser in situ keratomileusis flap femtosecond laser
下载PDF
Comparison of corneal flap thickness using a FS200femtosecond laser and a moria SBK microkeratome 被引量:5
5
作者 Jing Zhang Shi-Sheng Zhang +2 位作者 Qing Yu Jiang-Xiu Wu Jing-Cai Lian 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2014年第2期273-277,共5页
AIMTo evaluate differences in flap thickness resulting from use of an Alcon Wavelight FS200 femtosecond laser and a MORIA SBK microkeratome when making a 110-&#x000b5;m-thick corneal flap and to identify the poten... AIMTo evaluate differences in flap thickness resulting from use of an Alcon Wavelight FS200 femtosecond laser and a MORIA SBK microkeratome when making a 110-&#x000b5;m-thick corneal flap and to identify the potential factors that affect corneal flap thickness. 展开更多
关键词 corneal flap thickness femtosecond laser laser in situ keratomileusis MICROKERATOME
下载PDF
Comparison of corneal flaps created by Wavelight FS200 and Intralase FS60 femtosecond lasers 被引量:2
6
作者 Qian Liu Yue-Hua Zhou +3 位作者 Jing Zhang Yan Zheng Chang-Bin Zhai Jing Liu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2016年第7期1006-1010,共5页
AIM:To assess and compare the morphology of corneal flaps created by the Wavelight FS200 and Intralase FS60 femtosecond lasers in laser in situ keratomileusis(LASIK).METHODS:Four hundred eyes of 200 patients were ... AIM:To assess and compare the morphology of corneal flaps created by the Wavelight FS200 and Intralase FS60 femtosecond lasers in laser in situ keratomileusis(LASIK).METHODS:Four hundred eyes of 200 patients were enrolled in this study and divided into Wavelight FS200 groups(200 eyes) and Intralase FS60 groups(200 eyes).Fourier-domain optical coherence tomography(RTVue OCT) was used to measure the corneal flap thickness of 36 specified measurements on each flap one week after surgery.Results were used to analyze the regularity,uniformity and accuracy of the two types of LASIK flaps.RESULTS:The mean thickness of corneal flap and central flap was 105.71±4.72 μm and 105.39±4.50 μm in Wavelight FS200 group and 109.78±11.42 μm and 109.15±11.59 μm in Intralase FS60 group,respectively.The flaps made with the Wavelight FS200 femtosecond laser were thinner than those created by the Intralase FS60 femtosecond laser(P=0.000).Corneal flaps in the 2 groups were uniform and regular,showing an almost planar configuration.But the Wavelight FS200 group has more predictability and uniformity of flap creation.The mean deviation between achieved and attempted flap thickness was smaller in the Wavelight FS200 group than that in the Intralase FS60 group,which were 5.18±3.71 μm and 8.68±7.42 μm respectively.The deviation of more than 20 μm was 0.2% measurements in Wavelight FS200 group and 8.29% measurements in Intralase FS60 group.CONCLUSION:The morphologies of flaps created by Wavelight FS200 are more uniform and thinner than those created by Intralase FS60. 展开更多
关键词 Fourier-domain optical coherence tomography laser in situ keratomileusis flap femtosecond laser Wavelight FS200 intralase FS60
下载PDF
Comparison of the femtosecond Laser and mechanical microkeratome for flap cutting in LASIK 被引量:3
7
作者 Li-Kun Xia Jie Yu +2 位作者 Guang-Rui Chai Dang Wang Yang Li 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2015年第4期784-790,共7页
· AIM: To compare refractive results, higher-order aberrations(HOAs), contrast sensitivity and dry eye after laser in situ keratomileusis(LASIK) performed with a femtosecond laser versus a mechanical microkeratom... · AIM: To compare refractive results, higher-order aberrations(HOAs), contrast sensitivity and dry eye after laser in situ keratomileusis(LASIK) performed with a femtosecond laser versus a mechanical microkeratome for myopia and astigmatism.·METHODS: In this prospective, non-randomized study,120 eyes with myopia received a LASIK surgery with the Visu Max femtosecond laser for flap cutting, and 120 eyes received a conventional LASIK surgery with a mechanical microkeratome. Flap thickness, visual acuity, manifest refraction, contrast sensitivity function(CSF) curves,HOAs and dry-eye were measured at 1wk; 1, 3, 6mo after surgery.·RESULTS: At 6mo postoperatively, the mean central flap thickness in femtosecond laser procedure was113.05 ±5.89 μm(attempted thickness 110 μm), and148.36 ±21.24 μm(attempted thickness 140 μm) in mechanical microkeratome procedure. An uncorrected distance visual acuity(UDVA) of 4.9 or better was obtained in more than 98% of eyes treated by both methods, a gain in log MAR lines of corrected distance visual acuity(CDVA) occurred in more than 70% of eyes treated by both methods, and no eye lost ≥1 lines of CDVA in both groups. The difference of the mean UDVA and CDVA between two groups at any time post-surgery were not statistically significant(P 】0.05). The postoperative changes of spherical equivalent occurred markedly during the first month in both groups. The total root mean square values of HOAs and spherical aberrations in the femtosecond treated eyes were markedly less than those in the microkeratome treated eyes during 6mo visit after surgery(P 【0.01). The CSF values of the femtosecond treated eyes were also higherthan those of the microkeratome treated eyes at all space frequency(P 【0.01). The mean ocular surface disease index scores in both groups were increased at 1wk, and recovered to preoperative level at 1mo after surgery. The mean tear breakup time(TBUT) of the femtosecond treated eyes were markedly longer than those of the microkeratome treated eyes at postoperative 1, 3mo(P 【0.01).·CONCLUSION: Both the femtosecond laser and the mechanical microkeratome for LASIK flap cutting are safe and effective to correct myopia, with no statistically significant difference in the UDVA, CDVA during 6mo follow-up. Refractive results remained stable after 1mo post-operation for both groups. The femtosecond laser may have advantages over the microkeratome in the flap thickness predictability, fewer induced HOAs, better CSF,and longer TBUT. 展开更多
关键词 laser in situ keratomileusis femtosecond laser flap visual acuity higher-order aberrations contrast sensitivity dry eye
下载PDF
Comparison of Ziemer FEMTO LDV "Classic" and " Crystal Line" femtosecond laser flap quality by Fourierdomain optical coherence tomography
8
作者 Jing Zhang Yue-Hua Zhou +1 位作者 Lei Tian Chang-Bin Zhai 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2013年第5期611-617,共7页
AIM:To compare the regularity and accuracy of laser in situ keratomileusis(LASIK) flaps created by the Ziemer FEMTO LDV 'Classic'(Ziemer 'Classic') and Ziemer FEMTO LDV Crystal Line femtosecond laser(Z... AIM:To compare the regularity and accuracy of laser in situ keratomileusis(LASIK) flaps created by the Ziemer FEMTO LDV 'Classic'(Ziemer 'Classic') and Ziemer FEMTO LDV Crystal Line femtosecond laser(Ziemer Crystal Line). METHODS:Fourier-domain optical coherence tomography(RTVue OCT) was used to measure the morphology of 200 LASIK flaps of 100 consecutive patients created with the Ziemer Classic(100 flaps) or the Ziemer Crystal Line(100 flaps) at one week postoperatively.Flap thickness was evaluated at 36 specified measurement points on each flap.For all procedures with both lasers,the nominal flap thickness was 110μm.RESULTS:The mean flap thickness of the Ziemer Crystal Line group(102.49±2.68μm) was thinner than that of the Ziemer Classic group(107.65±5.09μm)(P【0.01).Average thickness of all flaps was uniform within 4μm at all measurement points.The flaps in the Ziemer Crystal Line group were more regular than those in the Ziemer Classic group when measured from the center to the periphery.The maximum deviation from the nominal 110μm of 36 measurements was 8μm in the Ziemer Classic group,while in the Ziemer Crystal Line group it was 9μm.Within the 3 600 measurements on the 100 eyes,differences greater than 20μm were observed 0.14% in the Ziemer Classic group,and 0.04% in the Ziemer Crystal Line group. CONCLUSION:The flaps created with the Ziemer FEMTO LDV Crystal Line femtosecond laser are more uniform and thinner than those created by the Ziemer FEMTO LDV Classic femtosecond laser. 展开更多
关键词 laser in situ keratomileusis flap thickness femtosecond laser fourier-domain optical coherence tomography
下载PDF
Comparative study of visual acuity and aberrations after intralase femtosecond LASIK:small corneal flap versus big corneal flap 被引量:4
9
作者 Ya-Li Zhang Lei Liu +5 位作者 Chang-Xia Cui Ming Hu Zhao-Na Li Li-Jun Cao Xiu-Hua Jing Guo-Ying Mu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2013年第5期641-645,共5页
AIM:To study the effects of different flap sizes on visual acuity,refractive outcomes,and aberrations after femtosecond laser for laser in situ keratomileusis(LASIK).METHODS:In each of the forty patients enrolled,1 ey... AIM:To study the effects of different flap sizes on visual acuity,refractive outcomes,and aberrations after femtosecond laser for laser in situ keratomileusis(LASIK).METHODS:In each of the forty patients enrolled,1 eye was randomly assigned to receive treatment with a 8.1mm diameter corneal flap,defined as the small flap,while the other eye was treated with a 8.6mm diameter corneal flap,defined as the big flap.Refractive errors,visual acuity,and higher-order aberrations were compared between the two groups at week 1,month 1 and 3 postoperatively. RESULTS:The postoperative refractive errors and visual acuity all conformed to the intended goal.Postoperative higher-order aberrations were increased,especially in spherical aberration(Z12) and vertical coma(Z7).There were no statistically significant differences between the two groups in terms of postoperative refractive errors,visual acuity,root mean square of total HOAs(HO-RMS),trefoil 30°(Z6),vertical coma(Z7),horizontal coma(Z8),trefoil 0°(Z9),and spherical aberration(Z12) at any point during the postoperative follow-up.CONCLUSION:Both the small and big flaps are safe and effective procedures to correct myopia,provided the exposure stroma meets the excimer laser ablations.The personalized size corneal flap is feasible,as we can design the size of corneal flap based on the principle that the corneal flap diameter should be equal to or greater than the sum of the maximum ablation diameter and apparatus error. 展开更多
关键词 femtosecond laser laser in situ keratomileusis refractive surgery flap visual acuity ABERRATION
下载PDF
Three-year results of small incision lenticule extraction and wavefront-guided femtosecond laser-assisted laser in situ keratomileusis for correction of high myopia and myopic astigmatism 被引量:20
10
作者 Li-Kun Xia Jing Ma +2 位作者 He-Nan Liu Ce Shi Qing Huang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第3期470-477,共8页
AIM: To compare and calculate the 3-year refractive results, higher-order aberrations (HOAs), contrast sensitivity (CS) and dry eye parameters after small incision lenticule extraction (SMILE) and wavefront-gui... AIM: To compare and calculate the 3-year refractive results, higher-order aberrations (HOAs), contrast sensitivity (CS) and dry eye parameters after small incision lenticule extraction (SMILE) and wavefront-guided femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) for correction of high myopia and myopic astigmatism. METHODS: In this prospective, non-randomized comparative study, 78 eyes with spherical equivalent (SE) of -8.11±1.09 diopters (D) received a SMILE surgery, and 65 eyes with SE of -8.05±1.12 D received a wavefront-guided FS-LASIK surgery with the VisuMax femtosecond laser (Carl Zeiss Meditec, Jena, Germany) for flap cutting. Visual acuity, manifest refraction, CS, HOAs, ocular surface disease index (OSDI) and tear break-up time (TBUT) were evaluated during a 3-year follow-up. RESULTS: The difference of uncorrected distance visual acuity (UDVA) postoperatively was achieved at lmo and at 3mo, whereas the difference of the mean UDVA between two groups at 3y were not statistically significant (t=-1.59, P=-0.13). The postoperative change of SE was 0.89 D in the FS-LASIK group (t=5.76, P=0.00), and 0.14 D in the SMILE group (t=-0.54, P=0.59) from lmo to 3y after surgery. At 3-year postoperatively, both HOAs and spherical aberrations in the SMILE group were obviously less than those in the FS-LASIK group (P=0.00), but the coma root mean square (RMS) was higher in the SMILE group (0.59±0.26) than in the FS-LASIK group (0.29±0.14, P=0.00). The mesopic CS values between two groups were not statistically significant at 3y postoperatively. Compared with the FS-LASIK group, lower OSDI scores and longer TBUT values were found in the SMILE group at Imo and 3mo postoperatively. With regard to safety, no eye lost any line of CDVA in both groups at 3y after surgery. CONCLUSION: Both SMILE and wavefront-guided FS- LASIK procedures provide good visual outcomes. Both procedures are effective and safe, but SMILE surgery achieve more stable long-term refractive outcome and better control of early postoperative dry eye as compared to FS-LASIK. 展开更多
关键词 small incision lenticule extraction wavefront-guided femtosecond laser-assisted laser in situ keratomileusis femtosecond laser refractive surgery visual outcome
下载PDF
Dry eye and corneal sensitivity after small incision lenticule extraction and femtosecond laser-assisted in situ keratomileusis:a Meta-analysis 被引量:10
11
作者 Wen-Ting Cai Qing-Yu Liu +6 位作者 Cheng-Da Ren Qing-Quan Wei Jun-Ling Liu Qian-Yi Wang Ya-Ru Du Meng-Mei He Jing Yu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第4期632-638,共7页
AIM:To assess the corneal sensitivity and the incidences of dry eye after small incision lenticule extraction(SMILE) and femtosecond laser-assisted in situ keratomileusis(FSLASIK).METHODS:The Meta-analysis was p... AIM:To assess the corneal sensitivity and the incidences of dry eye after small incision lenticule extraction(SMILE) and femtosecond laser-assisted in situ keratomileusis(FSLASIK).METHODS:The Meta-analysis was performed using Rev Man 5.3.We searched on Pub Med from inception to March 2016.Summary weighted mean difference(WMD) and 95% confidence intervals(CIs) were used to analyze the datum.Random-effects or fixed-effects models were chosen up to between-study heterogeneity.The main outcomes were composed of the Ocular Surface Disease Index(OSDI) scores,tear film break-up time(TBUT),Schirmer Test and corneal sensitivity.RESULTS:Eight eligible studies including 772 eyes(386 in SMILE group and 386 in FS-LASIK group) were identified.The parameters have no significiant difference heterogeneity between SMILE and FS-LASIK group preoperatively.There were significant differences between the two groups in OSDI scores at one and three months postoperatively,in TBUT at one and three months postoperatively,in corneal sensitivity at one week,about one month and three months postoperatively.However,there was no significant difference observed in Schirmer Test at the follow-up periods.CONCLUSION:Compare to FS-LASIK,dry eye and the corneal sensitivity recover better in the SMILE group,in first three months after the surgery. 展开更多
关键词 dry eye corneal sensation small incision lenticule extraction femtosecond laser-assisted in situ keratomileusis META-ANALYSIS
下载PDF
Optical and visual quality comparison of implantable collamer lens and femtosecond laser assisted laser in situ keratomileusis for high myopia correction 被引量:2
12
作者 Zheng Jiang Hua Wang +1 位作者 Dong-Qiang Luo Jiao Chen 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2021年第5期737-743,共7页
AIM:To compare clinical outcomes and refractive stability of implantable collamer lens(ICL)implantation and femtosecond laser assisted laser in situ keratomileusis(FSLASIK)for high myopia correction.METHODS:The Optica... AIM:To compare clinical outcomes and refractive stability of implantable collamer lens(ICL)implantation and femtosecond laser assisted laser in situ keratomileusis(FSLASIK)for high myopia correction.METHODS:The Optical Quality Analysis System(OQAS)was used to evaluate clinical outcomes objectively after operation for high myopia correction.We compared the two procedures in terms of 1-year changes in uncorrected distance visual acuity(UDVA),corrected distance visual acuity(CDVA),safety index,efficacy index,spherical equivalent,modulation transfer function(MTF)cutoff frequency,strehl ratio(SR)and objective scatter index(OSI).RESULTS:At 1 y postoperatively,the safety indices were 1.33±0.27 in ICL group,and 1.17±0.24 in FS-LASIK group.39.58%in the ICL group and 27.59%in the FS-LASIK group gained CDVA in 2 lines or better than that in preoperative CDVA.The efficacy indices were 1.28±0.22 in ICL group,and 1.13±0.26 in FS-LASIK group.The changes of spherical equivalent from 1 wk to 1 y postoperatively was-0.12±0.37 D in ICL group,and-0.79±0.58 D in FS-LASIK group(P<0.05).Spherical equivalent within±0.50 D was achieved in 97.92%in ICL group and 68.97%in FS-LASIK group.MTF cutoff frequency were higher with ICL as compared to FSLASIK(P<0.05)at each postoperative follow-up stage;for postoperative 1 mo later,SR was statistically significant difference between two groups(P<0.05);with no statistically significant difference in OSI between two groups(P>0.05)in postoperative 3 mo later.CONCLUSION:ICL implantation and FS-LASIK procedures both provide good safety and predictability in high myopia correction.ICL implantation provides better clinical outcomes and refractive stability than FS-LASIK. 展开更多
关键词 implantable collamer lens implantation femtosecond laser assisted laser in situ keratomileusis refractive stability high myopia
下载PDF
Satisfactory clinical outcome following delayed repositioning of a traumatic post-LASIK flap with dislocation and shrinkage managed by irrigation,stretching,and debridement
13
作者 Ye-sheng XU Wen-jia XIE Yu-feng YAO 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE CAS CSCD 2017年第6期539-543,共5页
Objective:To report surgical management and favorable outcome in a case with delayed repair of traumatic laser in situ keratomileusis(LASIK)flap dislocation with shrinkage and folds.Methods:A 30-year-old man with ... Objective:To report surgical management and favorable outcome in a case with delayed repair of traumatic laser in situ keratomileusis(LASIK)flap dislocation with shrinkage and folds.Methods:A 30-year-old man with a five-year history of bilateral LASIK experienced blunt trauma to his right eye followed by decreased vision for 5 weeks.The surgical management included initially softening the flap by irrigation with balanced salt solution(BSS).The shrinkage folds were carefully and gently stretched by scraping with a 26-gauge cannula accompanied by BSS irrigation.All of the epithelial ingrowth on the flap inner surface and on the bed was thoroughly debrided by scraping and irrigation.After the flap was repositioned to match its original margin,a soft bandage contact lens was placed.Results:At his initial visit,slit-lamp microscopy and optical coherence tomography(OCT)showed shrinkage of the LASIK flap with an elevated margin approximately 3 mm above the original position.The flap covered half of the pupil and had multiple horizontal folds.Two months after surgery,the flap remained well positioned with only faint streaks in the anterior stroma.The uncorrected visual acuity of the right eye was 20/20 with a manifest refraction of Plano.Conclusions:For delayed repair of traumatically dislocated LASIK flaps,sufficient softening by BSS,stretching the shrinkage folds,and thorough debridement of ingrowth epithelium enable resetting the flap and provide satisfactory results. 展开更多
关键词 Delayed repositioning laser in situ keratomileusis(LASIK) Traumatic flap dislocation
原文传递
Femtosecond laser corneal refractive surgery for the correction of high myopic anisometropic amblyopia in juveniles 被引量:4
14
作者 Jing Zhang Ke-Ming Yu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第11期1678-1685,共8页
AIM: To evaluate the effects of femtosecond laser-assisted in situ keratomileusis(FS-LASIK) and small-incision lenticule extraction(SMILE) to correct high myopic anisometropic amblyopia in juvenile patients. METH... AIM: To evaluate the effects of femtosecond laser-assisted in situ keratomileusis(FS-LASIK) and small-incision lenticule extraction(SMILE) to correct high myopic anisometropic amblyopia in juvenile patients. METHODS: From November 2013 to January 2015, 33 amblyopic patients with high myopic anisometropic amblyopia were studied. FS-LASIK(30 eyes) or SMILE(3 eyes) was performed in the amblyopic eyes. Visual acuity, refraction, contrast sensitivity, stereoacuity and complications were evaluated. Patients completed followup examinations at 3 d, 1 mo, 3 mo and the last follow-up time(mean 8.17±3.23 mo) after surgery. RESULTS: The mean age at surgery was 9.04±3.04 y(range 6-16 y). The mean spherical equivalent in the amblyopic eyes was significantly decreased from-10.00±2.39 D preoperatively to-0.06±1.06 D at 1 mo,-0.19±1.33 D at 3 mo and-0.60±1.43 D at approximately 8 mo postoperatively(P〈0.05 for all). The mean myopic anisometropia was significantly decreased from-9.45±2.33 D preoperatively to +0.37±1.48 D at 1 mo,-0.46±1.47 D at 3 mo and-0.09±1.83 D at approximately 8 mo(P〈0.05 for all). The logarithm of the minimum angle of resolution(log MAR) for uncorrected and corrected distance visual acuity(UDVA and CDVA, respectively) of the amblyopic eye improved from 1.74±0.35 and 0.98±0.63 preoperatively to 0.45±0.31 and 0.41±0.33 at approximately 8 mo after surgery, respectively. The logM AR CDVA at 3 d, 1, 3 and 8 mo postoperatively improved by means of 1.42, 2.22, 2.96, and 4.39 lines, and a gain of more than two lines accounted for 45%, 50%, 74% and 86% of all patients, respectively. The contrast sensitivity of both amblyopic eyes and dominant eyes at 0.5, 2, 8 cycles perdegree was significantly improved postoperatively(P〈0.05 for all). Of the 33 pediatric patients, no patients had near stereopsis preoperatively and seven patients(21.2%) recovered near stereopsis(400″ to 60″) at approximately 8 mo after surgery. No intraoperative or postoperative complications occurred in any patient.CONCLUSION: FS-LASIK or SMILE can be promising alternative methods to correct high myopic anisometropic amblyopia in juvenile patients who have failed with traditional approaches. 展开更多
关键词 refractive surgery myopic anisometropic amblyopia pediatric patients small-incision lenticule extraction femtosecond laser-assisted in situ keratomileusis
下载PDF
Effect of open ultraviolet germicidal irradiation lamps on functionality of excimer lasers used in cornea surgery
15
作者 Jaroslavas Belovickis Aliaksei Kurylenka Vadim Murashko 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第9期1474-1476,共3页
We report on the impact of direct ultraviolet germicidal irradiation(UVGI)on reflective optics,used in the excimer laser system Allegretto Eye-Q.The aim of our work was to confirm our hypothesis based on long-rate o... We report on the impact of direct ultraviolet germicidal irradiation(UVGI)on reflective optics,used in the excimer laser system Allegretto Eye-Q.The aim of our work was to confirm our hypothesis based on long-rate observations of obtained anomalies in post-operative results that are attributed to degradation of reflective optics upon ultraviolet radiation.The presence of direct UVGI coupled with humidity in the operating environment caused merging anomalies and unwanted post-operative correction values.Ultraviolet-A radiation caused a similar effect on the reflective cover of the mirrors. 展开更多
关键词 ultraviolet radiation excimer lasers post-operative anomalies laser-assisted in situ keratomileusis mirror degradation
下载PDF
LASEK和TransPRK及FS-LASIK术后角膜屈光力及视觉质量比较
16
作者 方薇 孙冉 +1 位作者 张伟 陈旭 《国际眼科杂志》 CAS 2024年第6期870-875,共6页
目的:比较准分子激光上皮下角膜磨镶术(LASEK)、经上皮准分子激光角膜切削术(TransPRK)、飞秒激光制瓣的准分子激光原位角膜磨镶术(FS-LASIK)三种角膜屈光手术术后角膜屈光力及视觉质量。方法:回顾性研究。选取2021-01/2022-12在我院择... 目的:比较准分子激光上皮下角膜磨镶术(LASEK)、经上皮准分子激光角膜切削术(TransPRK)、飞秒激光制瓣的准分子激光原位角膜磨镶术(FS-LASIK)三种角膜屈光手术术后角膜屈光力及视觉质量。方法:回顾性研究。选取2021-01/2022-12在我院择期行角膜屈光手术的232例464眼患者作为研究对象,根据患者选择手术方式不同分为LASEK组70例140眼、TransPRK组76例152眼、FS-LASIK组86例172眼。比较三组患者术前,术后1、3 mo时裸眼视力(UCVA)、视觉质量、生物力学稳定性、泪膜破裂时间(BUT)、泪液分泌试验(SⅠt)及生活质量变化情况。结果:术后1、3 mo三组患者裸眼视力较术前均改善,全角膜总高阶像差、球差、水平彗差、垂直彗差均升高,生物学稳定性均降低(均P<0.05)。术后3 mo, TransPRK组、LASEK组生物学稳定性均高于FS-LASIK组(均P<0.05),TransPRK组生活质量评分较LASEK组及FS-LASIK组高(P<0.05)。手术前后三组患者BUT、SⅠt比较均无差异(均P>0.05)。结论:LASEK、TransPRK、FS-LASIK三种角膜屈光手术治疗屈光不正疗效确切,在改善裸眼视力和提高视觉质量方面结果相似,但TransPRK、LASEK较FS-LASIK具有更稳定的生物力学性能,且TransPRK组在改善患者生活质量方面具有更好的效果。 展开更多
关键词 准分子激光上皮下角膜磨镶术(LASEK) 经上皮准分子激光角膜切削术(TransPRK) 飞秒激光制瓣的准分子激光原位角膜磨镶术(FS-LASIK) 角膜屈光手术 角膜屈光力 视觉质量
下载PDF
FS-LASIK Xtra治疗中高度近视患者术后2a的矫正效果 被引量:2
17
作者 李金孝 申笛 +3 位作者 周堃 孙西宇 王亚妮 韦伟 《国际眼科杂志》 2024年第2期295-300,共6页
目的:评估FS-LASIK Xtra治疗中高度近视患者术后2 a的矫正效果及角膜形态的稳定性。方法:回顾性病例对照研究。纳入2019-08/2020-08在我院拟行屈光手术的中高度近视合并散光患者30例58眼,根据术前角膜地形图中圆锥角膜筛查相关指数行不... 目的:评估FS-LASIK Xtra治疗中高度近视患者术后2 a的矫正效果及角膜形态的稳定性。方法:回顾性病例对照研究。纳入2019-08/2020-08在我院拟行屈光手术的中高度近视合并散光患者30例58眼,根据术前角膜地形图中圆锥角膜筛查相关指数行不同手术方式,分为FS-LASIK Xtra组15例29眼,FS-LASIK组15例29眼。术前,术后3 mo,1、2 a观察裸眼视力(UCVA)、最佳矫正视力(BCVA)、等效球镜度(SE)及Sirius三维角膜地形图仪测量的不同直径区域(3、5、7 mm)前后表面角膜曲率。结果:两组患者术后不同时间点UCVA均较术前明显提高(均P<0.01),两组间UCVA和SE比较均无差异(P>0.05)。术后2 a,FS-LASIK Xtra组25眼(86%),FS-LASIK组24眼(83%)残余散光为-0.25-0 D。两组实际矫正SE与预矫正SE均呈正相关(均P<0.05)。两组患者术后3 mo,1、2 a不同直径区域(3、5、7 mm)前后表面角膜曲率均较术前有差异(均P<0.05),术后1、2 a FS-LASIK Xtra组角膜直径3、5 mm后表面曲率均高于FS-LASIK组(P<0.05)。结论:FS-LASIK Xtra治疗中高度近视患者有良好的安全性、有效性及可预测性。 展开更多
关键词 飞秒激光辅助准分子激光原位角膜磨镶术(FS-LASIK) 快速角膜交联(Xtra) 近视 角膜曲率
下载PDF
基于Corvis ST分析飞秒LASIK联合快速交联矫正高度近视术后角膜生物力学变化
18
作者 王庆宝 毕宏生 +3 位作者 范华 祖培培 李莉 季鹏 《眼科新进展》 CAS 北大核心 2024年第8期632-636,共5页
目的应用Corvis ST评估飞秒激光辅助准分子激光原位角膜磨镶术(LASIK)联合快速角膜交联术(FS-LASIK Xtra)矫正高度近视术后角膜生物力学的变化。方法前瞻性病例对照研究。选取2020年7月至2022年7月在山东中医药大学附属眼科医院行手术... 目的应用Corvis ST评估飞秒激光辅助准分子激光原位角膜磨镶术(LASIK)联合快速角膜交联术(FS-LASIK Xtra)矫正高度近视术后角膜生物力学的变化。方法前瞻性病例对照研究。选取2020年7月至2022年7月在山东中医药大学附属眼科医院行手术矫正高度近视的患者185例(185眼)为研究对象,所有患者均将右眼纳入研究,其中行FS-LASIK Xtra者93例为FS-LASIK Xtra组,行FS-LASIK者92例为FS-LASIK组,术后随访6个月,记录患者的裸眼视力、等效球镜度、平均角膜曲率(Km)、最薄点角膜厚度(TCT)、角膜生物力学参数[2 mm处变形幅度比(DAR 2 mm)、综合半径(IR)、第一次压平刚度系数(SP-A1)、应力应变指数(SSI)]和手术前后角膜生物力学参数变化量(术后6个月与术前的差值,即ΔDAR 2 mm、ΔIR、ΔSP-A1、ΔSSI)。采用独立样本t检验和Mann-Whitney U检验对组间数据进行比较。结果术后3个月等效球镜度FS-LASIK组和FS-LASIK Xtra组患者分别为(-0.21±0.31)D和(-0.04±0.36)D,差异有统计学意义(t=3.49,P=0.001);术后6个月两组分别为(-0.33±0.31)D、(-0.14±0.37)D,差异均有统计学意义(t=4.00,P<0.001)。术后6个月时FS-LASIK组与FS-LASIK Xtra组患者手术的有效性指数和安全性指数差异均无统计学意义(均为P>0.05)。术前两组患者DAR 2 mm、IR、SP-A1、SSI等角膜生物力学参数比较差异均无统计学意义(均为P>0.05);术后6个月,FS-LASIK组与FS-LASIK Xtra组患者角膜生物力学参数变化量ΔIR分别为3.03±0.78、2.67±0.80,ΔSP-A1为-35.93±12.04、-30.43±12.44,ΔSSI为-0.09±0.10、-0.03±0.06,两组相比差异均有统计学意义(均为P<0.05)。结论FS-LASIK Xtra矫正高度近视术后患者视力、等效球镜度稳定,具有良好的安全性和有效性,角膜生物力学稳定性较术前降低,但优于常规FS-LASIK,长期效果需要进一步观察。 展开更多
关键词 高度近视 快速角膜交联 准分子激光原位角膜磨镶术 角膜生物力学 屈光手术
下载PDF
近视患者准分子激光原位角膜磨镶术围术期综合干预的效果分析
19
作者 何艳婷 杨新燕 +2 位作者 林小兰 王文娟 倪连红 《中国现代药物应用》 2024年第18期156-159,共4页
目的探究近视患者准分子激光原位角膜磨镶术(LASIK)的围术期综合干预效果。方法选择200例近视患者为研究对象,随机分为对照组和研究组,每组100例(200眼)。所有患者均进行准分子激光原位角膜磨镶术治疗,对照组给予围术期常规干预,研究组... 目的探究近视患者准分子激光原位角膜磨镶术(LASIK)的围术期综合干预效果。方法选择200例近视患者为研究对象,随机分为对照组和研究组,每组100例(200眼)。所有患者均进行准分子激光原位角膜磨镶术治疗,对照组给予围术期常规干预,研究组给予围术期综合干预。比较两组患者视觉质量[斯特列尔比(SR)、调制传递函数截止频率(MTF cutoff)及100%对比敏感度的视觉质量分析系统(OQAS)分值(OV100%)、20%对比敏感度的OQAS分值(OV20%)、9%对比敏感度的OQAS分值(OV9%)、客观散射指数(OSI)]、对干预方式的满意度、术后并发症发生率。结果研究组SR(0.27±0.09)、MTF cutoff(33.05±5.18)c/deg及OV100%(1.36±0.41)、OV20%(1.37±0.43)、OV9%(1.50±0.47)均大于对照组的(0.23±0.02)、(30.20±4.26)c/deg、(1.15±0.11)、(1.18±0.14)、(1.26±0.21),OSI(0.39±0.08)小于对照组的(0.46±0.12),差异有统计学意义(P<0.05)。研究组术后并发症发生率0.50%低于对照组的12.50%,差异有统计学意义(P<0.05)。研究组总满意率99.00%高于对照组的75.00%,差异有统计学意义(P<0.05)。结论给予近视患者准分子激光原位角膜磨镶术手术围术期综合干预能够减少术后并发症的发生,提高患者满意度,改善视觉质量。 展开更多
关键词 近视 准分子激光原位角膜磨镶术 综合干预 视觉质量 并发症 围术期
下载PDF
DIAGNOSIS AND TREATMENT FOR DEGENERATIVE RETINOSCHISIS OF MEDIUM TO HIGH MYOPIA IN YOUNG ADULTS PRIOR TO LASER-ASSISTED IN SITU KERATOMILEUSIS SURGERY
20
作者 孙昕 冯佩丽 闫焱 《Medical Bulletin of Shanghai Jiaotong University》 CAS 2013年第1期38-40,共3页
Objective To discuss the characteristics of degenerative retinoschisis in young adults with medium to high myopia prior to laser-assisted in situ keratomileusis(LASIX) surgery and the significance of preventive photoc... Objective To discuss the characteristics of degenerative retinoschisis in young adults with medium to high myopia prior to laser-assisted in situ keratomileusis(LASIX) surgery and the significance of preventive photocoagulation.Methods A total of 32 eyes in 19 patients suffering from myopia combined with degenerative retinoschisis were included.The mean best-corrected visual acuity was 0.82±0.13 and the mean spherical equivalent of the subjective refraction was -(6.50±3.98) Diopter. The patients underwent preventive photocoagulation 1 month before the laser surgery for myopia.Results All the eyes that received preventive photocoagulation for retinoschisis had no further progression or retinal detachment during 4-year period of follow-up.Conclusion The degenerative retinoschisis in young adults should be recognized and treated with preventive photocoagulation.This may prevent further damage of visual field and other complications of slowly progressive retinoschisis after LASIK surgery. 展开更多
关键词 RETinOSCHISIS PHOTOCOAGULATION myopia laser-assisted in situ keratomileusis
原文传递
上一页 1 2 15 下一页 到第
使用帮助 返回顶部